System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during a NG shortage offer one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73- bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dis- patch is proposed to allow representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

duel-fuel generator performance↗

Summary of DM1200 WESP History and Performance

The principal objective of this report was to summarize the testing experience on the DM1200 WESP. Further objectives were to provide descriptions of the history of all modifications and maintenance, methods of operation, problems and unit failures, and performance while processing a variety of feeds, and while employing a variety of operating methods, and to provide comparisons to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) high level waste (HLW) and low activity waste (LAW) WESP designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of DM1200 SBS history and performance

The principal objective of this report is to summarize the testing experience on the DM1200 SBS. Further objectives are to provide descriptions of the history of all modifications and maintenance, methods of operation, problems and unit failures, and performance while processing a variety of feeds, and while employing a variety of operating methods, and to provide comparisons to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) High Level Waste (HLW) and Low Activity Waste (LAW) Submerged Bed Scrubber (SBS) designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during an NG shortage over one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73-bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dispatch is proposed to allow the representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

dual-fuel capable generator↗

Performance Comparisons for Artificially Propagated and Wild Pacific Lamprey Juveniles and Larvae

ABSTRACT Artificially propagated Pacific lamprey ( Entosphenus tridentatus ) are produced for restoration and for use in dam passage studies to reduce the demand for wild fish. Such uses require that animals are representative of their wild counterparts. Previous work indicated that this is true for Pacific lamprey larvae and juveniles reared in the hatchery with respect to the length of sustained swimming. However, more subtle differences in behaviour and performance that lamprey need to survive have not been assessed. In this study, artificially propagated and wild fish were compared in laboratory tests under no‐flow conditions to examine light avoidance, burrowing speed, burst swim speed, volitional routine swim speed and time to come to rest. Most larvae burrowed in less than a minute, and we found highly significant differences ( p < 0.001) between artificially propagated and wild larvae burrowing times, a critical escape behaviour. This could have implications for studies of larval entrainment at irrigation diversion canals or in turbine boils at dams. Interestingly, all of the wild juveniles tested came to rest quickly after introduction to the chamber (1.5 min), while artificially propagated lamprey swam robotically near the surface and 48% did not come to rest in the first 10 min (median time to rest = 9.5 min). In contrast, wild juveniles quickly (median = 1.47 min) sought areas near the tank bottom and attached strongly with their oral disc. Such behavioural differences could have important survival consequences for artificially propagated lamprey as they approach turbine intakes, bypass screens and irrigation diversion headgates. This study highlights the need to conduct behavioural assays that examine subtleties of fish behaviour that can be missed with traditional swim tunnel comparisons.

Frick, Kinsey [Fish Ecology Division, Northwest Fi↗

Experimental Verification of An Electro-Hydraulic Actuation System Driven by An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and a novel-designed electro-hydraulic unit (EHU) consisting of a fixed-displacement hydraulic gear machine and a variable-speed electric machine. The novel EHU design integrates an electric machine and a hydraulic machine in a single housing, targeting optimal compactness, power density, and component reduction. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. Here, the efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The efficiency of the EHA system based on the measurements on the test rig can reach 54% with up to 20 kN load and 6 kW power level. Furthermore, the EHU is implemented on the reference machine to drive the boom function. Preliminary results on the performance of the EHU show an efficiency of up to 68% under different loading conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

Design of high deflection foils for MHK applications - CFD files

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. OpenFOAM V1912 files for straight foil model scale turbines in the University of New Hampshire tow tank. Strut Locations = (0.13, 0.225, 0.450, 0.675, 0.900) [m] Tip speed ratio = 2.40

16 TIDAL AND WAVE POWER↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Estimation of Respirable Aerosol Release Fractions through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the significant backfill pressurization of the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the carrier gas flow rates and aerosol transmission properties were evaluated for an engineered microchannel with characteristic dimensions similar to those of an SCC. The microchannel was formed by mating two gage blocks with a slot orifice measuring 28.9 μm (0.0011 in.) tall by 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, Ce0 2 , were seeded and mixed inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Separate modeling efforts are also underway that will be validated using these data. The test apparatus and procedures developed in this study can be easily modified for the evaluation of more complex SCC-like geometries including laboratory-grown SCC samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flowable Cementitious Grouts for False Bottoms in Hanford Waste Tanks – 26085

Cementitious grouts with epoxy coatings are being evaluated as an approach to refurbish the bottom of waste tanks at the Hanford Site. This work studies four grout concept materials for this application, two grouts being from commercial vendors and two grouts based off formulations used to close reactors and tanks at the Savannah River Site. All the candidate grouts demonstrate flowability and pumpability at the 0.5 cu ft scale. The commercial vendor products demonstrate the best flow and have lower water/premix ratio and are less likely to have bleed, which would impact epoxy bonding to the grout. The commercial products also demonstrate increased compression strengths compared to the reactor closure grouts. Additional fresh and cured properties for all the grout formulations were similar. The grouts in the tank waste simulant without epoxy coating do not crack but show visual changes to the grout and the surrounding simulant solution, and simulant absorption into the grout. The grout/epoxy bond in ambient conditions has strengths of over 7 MPa and needs to be evaluated for simulant chemical durability. Overall, the results to date justify testing the flowability, pumpability, and placement of the grouts at larger, engineering scale and for further studies of the interactions between the grout and epoxy.

Valdes, Nicholas [Savannah River National Laborato↗

Conceptual Model Testing Related to SDU 6 Drainwell Observations

From its inception in the early 1950s through the end of the Cold War in the early 1990s, the Savannah River Site (SRS) produced nuclear materials for national defense in five reactors. Additionally, irradiated reactor fuel and target tubes were dissolved in nitric acid to recover plutonium and uranium using the PUREX (Plutonium Uranium Reduction EXtraction) process. Liquid waste from these chemical separations processes was then stored onsite in 51 underground tanks. Eight waste storage tanks have been operationally closed (i.e. cleaned and grouted) and the remaining tanks hold a mixture of liquids, insoluble solids, and precipitated salts (SRMC-LWP-2022-00001), the latter generated by evaporating water from the liquid waste. Waste is currently being retrieved from tanks and separated into 1) high-radioactivity, low-volume, and 2) low-radioactivity, high-volume components, principally through the Salt Waste Processing Facility (SWPF) (SRMC-LWP-2023-00001). The former waste stream is vitrified in the Defense Waste Processing Facility (DWPF), stored onsite, and destined for offsite disposal in a deep geologic repository. The latter stream is mixed with dry cementitious materials in the Saltstone Production Facility (SPF) and the wet slurry placed in onsite Saltstone Disposal Units (SDUs) within the Saltstone Disposal Facility (SDF), where it hardens into a cement waste form termed saltstone. A low-infiltration surface cover system will be placed over the SDF at closure, where SDUs will then be in the subsurface post-closure (SRR-CWDA-2019-00001).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Fluorine Limits and Impacts in High-Level Waste Glass Compositions

The impact of elevated fluorine (F) content on Hanford high-level waste (HLW) glasses has not previously been studied in detail. This effort represents the first systematic study to determine what F concentration limits should be used for the design of alkali-borosilicate-based Hanford Waste Treatment and Immobilization Plant (WTP) HLW glasses, and to document the technical basis for that limit. If alkali borosilicate glass made from Hanford HLW can accommodate a large amount of F, the large capital costs for complex sludge washing facilities may be avoided, as would much of the operational costs and negative schedule impacts associated with handling the large volumes of water required to dissolve these salts. In order to determine a limit for F in likely HLW glass compositions, an evaluation was conducted on glasses with F ≤ 0.90 mass% from previous nuclear waste glass studies. The collected dataset contains 239 glasses (232 HLW glasses and 7 LAW glasses) including 109 glasses with 0.9 ≤ F mass% ≤ 2.5, 116 with 2.5 < F mass% ≤ 8.0, and 14 with F mass% ≥ 8 (max. F mass% = 17.42). The collected composition and property data were analyzed to determine the basis for the F tolerance, i.e. the maximum F concentration that can be processed without potential issues. Fluorine volatility, product consistency test (PCT) response, liquidus temperature (T L ), glass melt viscosity, and crystallinity have been investigated. No limits for F concentration can be made based on F volatility, T L , or glass melt viscosity, because the data show that high F in glasses do not indicate, with high probability, being restricted by those property constrains. However, crystallinity and PCT response were used to estimate the F tolerance. The results show that glasses with high F (≥ 0.90 mass%) are more likely to form large fractions of F-containing crystal phases which may increase PCT responses, i.e. decrease the glass durability. Based on the results of crystallinity and PCT data, the F tolerance of 4.5 mass% is estimated. There is no evidence of other glass components, such as calcium oxides and alkali metal oxides have combined impacts with F on the glass properties. Overall, the available high-F glass data is limited, especially in the designed HLW glass composition regions. Future work on formulation and testing of HLW glasses with F ≥ 0.9 mass% will close the data gaps and expand operational flexibility with respect to the fluoride tolerances. Volatility of F from melters and corrosion of materials in contact with glass melts are important for processing of high-F wastes; yet no test data are currently available. It is recommended tests be conducted to address these two potential issues.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Potential Routes for Titanium and Mercury Concentrations within Salt Waste Processing Facility

Savannah River National Laboratory (SRNL) has been requested by Savannah River Mission Completion (SRMC)/ Salt Waste Processing Facility (SWPF) personnel to investigate the potential routes for titanium and mercury accumulations within the SWPF Flowsheet. The first part of this work examined how various forms of mercury can migrate through the solvent extraction system. This entailed single stage distribution tests, a multi-stage Extraction-Scrub-Strip (ESS) test, and a detailed speciation analysis of several salt batch feed samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Screening Evaluation of Sovereign NOH2O

Southwest Research Institute (SwRI) was contracted by Sovereign Hydroseal Energy, Inc to provide evaluation of the NOH2O polymer grout technology as a feasible tank bottom repair in support of Washington River Protection Solutions, LLC (WRPS) Solicitation #358012 Statement of Work (SOW) “Screening Evaluation of Sovereign NOH2O”, which a copy is located in Appendix A. The evaluation focused on screening the mechanical properties of NOH2O under normal, chemical and radiological conditions, which was identified as Task 2 of the SOW. Testing was performed in accordance with the SwRI Test Plan located in Appendix B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗