Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRAJECTORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silica nanocluster binding rate coefficients from molecular dynamics trajectory calculations

Oxide nanoparticle growth from vapor phase precursors occurs in high temperature aerosol reactors first via the formation of nanoclusters, which are nanometer-scale condensed-phase species composed of 10 1 -10 2 atoms. The binding rate for nanoclusters, defined as the rate at which two nanoclusters collide with and stick to one another, is hence of interest in predicting nanoparticle size distribution functions in an aerosol. We have utilized molecular dynamics (MD) trajectory calculations to determine the homogeneous (equal-sized) and heterogeneous (disparate-sized) binding rate coefficients of SiO2 (silica) nanoclusters composed of 18, 144, and 333 atoms. MD trajectory calculations incorporated all-atom models of nanoclusters using a combined Born–Huggins–Mayer-Lennard-Jones potential model, which accounts for both short range interactions and electrostatic interactions. MD calculations were utilized to determine the binding probability as a function of both initial relative velocity and impact parameter; integration of the binding probability across impact parameter and relative velocity space yields the binding rate coefficient. MD trajectory calculations reveal that the most common type of encounters between nanoclusters leading to binding are grazing collisions, i.e. instances where collision would not occur without induced dipole potential influences. The resulting binding rate coefficients are found to be extremely weakly dependent on system temperature, which is in contrast to the use of rate coefficient models which are the product of a hard-sphere collision rate coefficient and a constant enhancement factor (leading to a rate coefficient proportional to the square root of temperature). Enhancement factors defined from MD trajectory calculations fall in the range of 3–9 as system temperature decreases from 1500 K to 300 K. Furthermore, such large values suggest that potential interactions need to be considered when modeling oxide nanocluster growth in the gas phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial dynamics of steady flames 1. Phase space structure and the dynamics of individual trajectories.

The spatial dynamics of steady, one-dimensional premixed H{sub 2}/O{sub 2} flames are studied. The emphasis in this Article is the geometry of the phase space of the dynamical system describing the steady flames. It is shown that steady flames are described by trajectories on the stable manifolds of saddle fixed points. The saddle fixed points correspond to equilibrium points of time-dependent chemical-kinetic systems that are adiabatic and isobaric and whose constant enthalpy matches the asymptotic enthalpy of the flames. The dimensions of the stable manifolds match the dimensions of the chemical-kinetic systems under most conditions, although the dynamics on them are different. It is further shown that the stable manifolds have low-dimensional attractive submanifolds near the saddlepoint. An algorithm for generating trajectories over the spatial domain of these flames is proposed, and it is used to study individual trajectories and trajectory ensembles, whose collective behavior suggests that there are low-dimensional submanifolds away from the saddlepoint.

08 HYDROGEN↗

CryoTRANS: predicting high-resolution maps of rare conformations from self-supervised trajectories in cryo-EM

Cryogenic electron microscopy (cryo-EM) has revolutionized structural biology, enabling efficient determination of structures at near-atomic resolutions. However, a common challenge arises from the severe imbalance among various conformations of vitrified particles, leading to low-resolution reconstructions in rare conformations due to a lack of particle images in these quasi-stable states. We introduce CryoTRANS, a method that predicts high-resolution maps of rare conformations by constructing a self-supervised pseudo-trajectory between density maps of varying resolutions. This trajectory is represented by an ordinary differential equation parameterized by a deep neural network, ensuring retention of detailed structures from high-resolution density maps. By leveraging a single high-resolution density map, CryoTRANS significantly improves the reconstruction of rare conformations and has been validated on four real-world datasets: alpha-2-macroglobulin, actin-binding protein complexes, SARS-CoV-2 spike glycoprotein, and the 70S ribosome. CryoTRANS can also predict high-resolution structures in cryogenic electron tomography maps using a high-resolution cryo-EM map.Cryogenic electron microscopy (cryo-EM) has revolutionized structural biology, enabling efficient determination of structures at near-atomic resolutions. However, a common challenge arises from the severe imbalance among various conformations of vitrified particles, leading to low-resolution reconstructions in rare conformations due to a lack of particle images in these quasi-stable states. We introduce CryoTRANS, a method that predicts high-resolution maps of rare conformations by constructing a self-supervised pseudo-trajectory between density maps of varying resolutions. This trajectory is represented by an ordinary differential equation parameterized by a deep neural network, ensuring retention of detailed structures from high-resolution density maps. By leveraging a single high-resolution density map, CryoTRANS significantly improves the reconstruction of rare conformations and has been validated on four real-world datasets: alpha-2-macroglobulin, actin-binding protein complexes, SARS-CoV-2 spike glycoprotein, and the 70S ribosome. CryoTRANS can also predict high-resolution structures in cryogenic electron tomography maps using a high-resolution cryo-EM map.

47 OTHER INSTRUMENTATION↗

Extended Hamiltonian molecular dynamics: semiclassical trajectories with improved maintenance of zero point energy

It is well known that classical trajectories, even if they are initiated with zero point energy (ZPE) in each mode (trajectories initiated this way are commonly called quasiclassical trajectories), do not maintain ZPE in the final states. The energy of high-frequency modes will typically leak into low-frequency modes or relative translation of subsystems during the time evolution. This can lead to severe problems such as unphysical dissociation of a molecule, production of energetically disallowed reaction products, and unphysical product energy distributions. Here a new molecular dynamics method called extended Hamiltonian molecular dynamics (EHMD) is developed to improve the ZPE problem in classical molecular dynamics. In EHMD, two images of a trajectory are connected by one or more springs. The EHMD method is tested with the Henon–Heiles Hamiltonian in reduced and real units and with a Hamiltonian with quartic anharmonicity in real units, and the method is found to improve zero-point maintenance as intended.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Material coherence from trajectories via Burau eigenanalysis of braids

In this paper, we provide a numerical tool to study a material’s coherence from a set of 2D Lagrangian trajectories sampling a dynamical system, i.e., from the motion of passive tracers. We show that eigenvectors of the Burau representation of a topological braid derived from the trajectories have levelsets corresponding to components of the Nielsen–Thurston decomposition of the dynamical system. One can thus detect and identify clusters of space–time trajectories corresponding to coherent regions of the dynamical system by solving an eigenvalue problem. Unlike previous methods, the scalable computational complexity of our braid-based approach allows the analysis of large amounts of trajectories.

36 MATERIALS SCIENCE↗

Analytic and numerical vibronic spectra from quasi-classical trajectory ensembles

The truncated Wigner approximation to quantum dynamics in phase space is explored in the context of computing vibronic line shapes for monomer linear optical spectra. We consider multiple model potential forms including a shifted harmonic oscillator with both equal and unequal frequencies on the ground and excited state potentials as well as a shifted Morse potential model. For the equal-frequency shifted harmonic oscillator model, we derive an analytic expression for the exact vibronic line shape that emphasizes the importance of using a quantum mechanical distribution of phase space initial conditions. For the unequal-frequency shifted harmonic oscillator model, we are no longer able to obtain an exact expression for the vibronic line shape in terms of independent deterministic classical trajectories. We show how one can rigorously account for corrections to the truncated Wigner approximation through nonlinear responses of the line shape function to momentum fluctuations along a classical trajectory and demonstrate the qualitative improvement in the resulting spectrum when the leading-order quantum correction is included. Finally, we numerically simulate absorption spectra of a highly anharmonic shifted Morse potential model. We find that, while finite quantization and the dissociation limit are captured with reasonable accuracy, there is a qualitative breakdown of the quasi-classical trajectory ensemble’s ability to describe the vibronic line shape when the relative shift in Morse potentials becomes large. The work presented here provides clarity on the origin of unphysical negative features known to contaminate absorption spectra computed with quasi-classical trajectory ensembles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An implicit solution for Asay foil trajectories generated by separable, sustained-production ejecta source models

We present a simple implicit solution for the time-dependent trajectory of a thin Asay foil ejecta diagnostic for the general case where the impinging ejecta cloud is generated by a source function characterized by an arbitrary (sustained) time dependence and a time-independent (stationary) particle velocity distribution. In the limit that the source function time dependence becomes a delta function, this solution—which is amenable to rapid numerical calculations of arbitrary accuracy—exactly recovers a previously published solution for the special case of instantaneous ejecta production. We also derive simple expressions for the free-surface arrival (catch-up) time as well as the true ejecta areal mass accumulation on the accelerating foil and place bounds on the level of error incurred when applying instant-production mass solutions to a sustained-production trajectory. We demonstrate these solutions with example calculations for hypothetical source functions spanning a wide range of ejecta production durations, velocity distributions, and temporal behaviors. These calculations demonstrate how the foil trajectory is often insensitive to the temporal dependence of the source function, instead being dominated by the velocity distribution. We quantify this insensitivity using a “compatibility score” metric. Under certain conditions, one may capitalize upon this insensitivity to obtain a good approximation of the second integral of the velocity distribution from the observed foil trajectory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Trajectories of S-matrix poles in a new finite-range potential

The trajectories of S-matrix poles are calculated in the finite-range phenomenological potential introduced recently by Salamon and Vertse [Phys. Rev. C 77, 037302 (2008)] (SV). The potential is similar to a Woods-Saxon (WS) interaction, but it is exactly zero beyond a radius, without any cutoff. The trajectories of the resonance poles in this SV potential are compared to the corresponding trajectories in a cutoff WS potential for l>0. The dependence on the cutoff radius is demonstrated. The starting points of the trajectories turn out to be related to the average ranges of the two terms in the SV potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Importance Sampling Model-Based Diffusion for Trajectory Optimization

Trajectory optimization for robotic systems remains a challenging problem. This is especially true for robotic systems featuring nonlinear dynamics and many degrees of freedom. Data-based or model-free diffusion has recently been popularized in the fields of artificial intelligence and trajectory optimization. Model-Based Diffusion provides a data-free method of trajectory optimization, trained at runtime on a system dynamics model, suitable for high-dimensional models. This paper examines how importance sampling can enhance the performance of Model-Based Diffusion for trajectory optimization. Here, we quantify the benefits of importance sampling across three long horizon planning tasks. These results show as much as a 13x improvement in sample efficiency depending on environment and optimization parameters.

Golembeski, Seth [Georgia Institute of Technology,↗

Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: An initial phantom study using patient tumor trajectory data

Purpose: In spot-scanning proton therapy, the interplay effect between tumor motion and beam delivery leads to deterioration of the dose distribution. To mitigate the impact of tumor motion, gating in combination with repainting is one of the most promising methods that have been proposed. This study focused on a synchrotron-based spot-scanning proton therapy system integrated with real-time tumor monitoring. The authors investigated the effectiveness of gating in terms of both the delivered dose distribution and irradiation time by conducting simulations with patients' motion data. The clinically acceptable range of adjustable irradiation control parameters was explored. Also, the relation between the dose error and the characteristics of tumor motion was investigated.Methods: A simulation study was performed using a water phantom. A gated proton beam was irradiated to a clinical target volume (CTV) of 5 Multiplication-Sign 5 Multiplication-Sign 5 cm{sup 3}, in synchronization with lung cancer patients' tumor trajectory data. With varying parameters of gate width, spot spacing, and delivered dose per spot at one time, both dose uniformity and irradiation time were calculated for 397 tumor trajectory data from 78 patients. In addition, the authors placed an energy absorber upstream of the phantom and varied the thickness to examine the effect of changing the size of the Bragg peak and the number of required energy layers. The parameters with which 95% of the tumor trajectory data fulfill our defined criteria were accepted. Next, correlation coefficients were calculated between the maximum dose error and the tumor motion characteristics that were extracted from the tumor trajectory data.Results: With the assumed CTV, the largest percentage of the data fulfilled the criteria when the gate width was {+-}2 mm. Larger spot spacing was preferred because it increased the number of paintings. With a prescribed dose of 2 Gy, it was difficult to fulfill the criteria for the target with a very small effective depth (the sum of an assumed energy absorber's thickness and the target depth in the phantom) because of the sharpness of the Bragg peak. However, even shallow targets could be successfully irradiated by employing an adequate number of paintings and by placing an energy absorber of sufficient thickness to make the effective target depth more than 12 cm. The authors also observed that motion in the beam direction was the main cause of dose distortion, followed by motion in the lateral plane perpendicular to the scan direction.Conclusions: The results suggested that by properly adjusting irradiation control parameters, gated proton spot-scanning beam therapy can be robust to target motion. This is an important first step toward establishing treatment plans in real patient geometry.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-09: Planning and Delivery of the Fully Dynamic Trajectory Modulated Arc Therapy: Application to Accelerated Partial Breast Irradiation

Purpose: A novel trajectory modulated arc therapy (TMAT) system was developed that uses source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement. MLC motion and dose rate were fully optimized for dynamic beam delivery. This work presents a platform for planning deliverable TMAT on a collision free coronal trajectory and evaluates its benefit for accelerated partial breast irradiation (APBI) in a prone position. Methods: The TMAT algorithm was built on VMAT with modifications (physical properties on couch movement were defined) and enhancements (pencil beam dose calculation engine to support extended SSDs) to make it feasible for TMAT delivery. A Matlab software environment for TMAT optimization and dose calculation was created to allow any user specified motion axis. TMAT delivery was implemented on Varian TrueBeamTM STx via XML scripts. 10 prone breast irradiation cases were evaluated in VMAT and compared with a 6- field non-coplanar IMRT plan. Patient selection/exclusion criteria and structure contouring followed the guidelines of NSABP B-39/RTOG 0413 protocol. Results: TMAT delivery time was ∼4.5 minutes. 251.5°±7.88° of non-isocentric couch arc was achieved by the optimized trajectory with 180– 210 control points at 1°–2° couch increments. The improved dose distribution by TMAT was most clearly observed by the marked reduction in the volume of irradiated normal breast tissue in the high dose region. The ratios of the normal breast tissue volume receiving more than 50%, 80% and 100% of the prescription dose for TMAT versus IMRT were: V50%(TMAT/IMRT) = 78.38%±13.03%, V80%(TMAT/IMRT) = 44.19%±9.04% and V100% (TMAT/IMRT) = 9.96%±7.55%, all p≤0.01. Conclusion: The study is the first demonstration of planning and delivery implementation of a fully dynamic APBI TMAT system with continuous couch motion. TMAT achieved significantly improved dosimetry over noncoplanar IMRT on dose volume parameters correlated with toxicity and cosmetic outcome of APBI. This project was supported by Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-T-436: Fluence-Based Trajectory Optimization for Non-Coplanar VMAT

Purpose: To investigate a fluence-based trajectory optimization technique for non-coplanar VMAT for brain cancer. Methods: Single-arc non-coplanar VMAT trajectories were determined using a heuristic technique for five patients. Organ at risk (OAR) volume intersected during raytracing was minimized for two cases: absolute volume and the sum of relative volumes weighted by OAR importance. These trajectories and coplanar VMAT formed starting points for the fluence-based optimization method. Iterative least squares optimization was performed on control points 24° apart in gantry rotation. Optimization minimized the root-mean-square (RMS) deviation of PTV dose from the prescription (relative importance 100), maximum dose to the brainstem (10), optic chiasm (5), globes (5) and optic nerves (5), plus mean dose to the lenses (5), hippocampi (3), temporal lobes (2), cochleae (1) and brain excluding other regions of interest (1). Control point couch rotations were varied in steps of up to 10° and accepted if the cost function improved. Final treatment plans were optimized with the same objectives in an in-house planning system and evaluated using a composite metric - the sum of optimization metrics weighted by importance. Results: The composite metric decreased with fluence-based optimization in 14 of the 15 plans. In the remaining case its overall value, and the PTV and OAR components, were unchanged but the balance of OAR sparing differed. PTV RMS deviation was improved in 13 cases and unchanged in two. The OAR component was reduced in 13 plans. In one case the OAR component increased but the composite metric decreased - a 4 Gy increase in OAR metrics was balanced by a reduction in PTV RMS deviation from 2.8% to 2.6%. Conclusion: Fluence-based trajectory optimization improved plan quality as defined by the composite metric. While dose differences were case specific, fluence-based optimization improved both PTV and OAR dosimetry in 80% of cases.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-02: Developing a Phenomenological Model of the Proton Trajectory Within a Heterogeneous Medium Required for Proton Imaging

Purpose: To develop an accurate phenomenological model of the cubic spline trajectory (CST) estimate of the proton path, accounting for the initial proton energy and water equivalent thickness (WET) traversed. Methods: Geant4 Monte Carlo (MC) simulations were used to calculate the path of protons crossing various slabs (5–30 cm WET) of different material (LN300, water and CB2–50% CaCO3) for a range of initial energies (150–330MeV). For each MC trajectory, CST was constructed based on the proton entrance and exit information and compared with the MC using the root mean square (RMS) metric. The CST path is dependent on the direction vector magnitudes (|P0,1|). First, |P0,1| is set to the proton path length. Then, a factor Λ is introduced to modify |P0,1|. The factor is varied to minimize the RMS with MC paths for every configuration. Finally, a set of Λopt factors that minimizes the RMS is presented. These are dependent on the ratio between WET and water equivalent path length (WEPL). The resolution along the path is investigated with a set of slabs. MTF analysis is performed on proton radiographs of a line-pair phantom reconstructed using the CST trajectories (Λopt and Λ1). Results: Λopt was fitted to the ratio of WET/WEPL using a power function (Y=1-AXB where A=0.36, B=4.07). The RMS deviation calculated along the path, between the CST and the MC path, increases with the WET. The increase is larger when using Λ1 than Λopt (difference of 5.0% with WET/WEPL=0.86). For 230(330) MeV protons, the MTF10% was found to increase by 40%(6%) respectively for a thick phantom (30cm) and by 25%(1%) for thinner phantom (25cm) when using the Λopt model compared to the Λ1 model. Conclusion: Based on these results, using CST with the Λopt factor reduces the RMS deviation and increases the spatial resolution when reconstructing proton trajectories.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically used in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging.

60 APPLIED LIFE SCIENCES↗

SU-F-R-12: Prediction of TrueBeam Hardware Issues Using Trajectory Log Analysis

Purpose: To predict potential failures of hardware within the Varian TrueBeam linear accelerator in order to proactively replace parts and decrease machine downtime. Methods: Machine downtime is a problem for all radiation oncology departments and vendors. Most often it is the result of unexpected equipment failure, and increased due to lack of in-house clinical engineering support. Preventative maintenance attempts to assuage downtime, but often is ineffective at preemptively preventing many failure modes such as MLC motor failures, the need to tighten a gantry chain, or the replacement of a jaw motor, among other things. To attempt to alleviate downtime, software was developed in house that determines the maximum value of each axis enumerated in the Truebeam trajectory log files. After patient treatments, this data is stored in a SQL database. Microsoft Power BI is used to plot the average maximum error of each day of each machine as a function of time. The results are then correlated with actual faults that occurred at the machine with the help of Varian service engineers. Results: Over the course of six months, 76,312 trajectory logs have been written into the database and plotted in Power BI. Throughout the course of analysis MLC motors have been replaced on three machines due to the early warning of the trajectory log analysis. The service engineers have also been alerted to possible gantry issues on one occasion due to the aforementioned analysis. Conclusion: Analyzing the trajectory log data is a viable and effective early warning system for potential failures of the TrueBeam linear accelerator. With further analysis and tightening of the tolerance values used to determine a possible imminent failure, it should be possible to pinpoint future issues more thoroughly and for more axes of motion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of implanted marker trajectories from cone-beam CT projection images using interdimensional correlation modeling

Purpose: Cone-beam CT (CBCT) is a widely used imaging modality for image-guided radiotherapy. Most vendors provide CBCT systems that are mounted on a linac gantry. Thus, CBCT can be used to estimate the actual 3-dimensional (3D) position of moving respiratory targets in the thoracic/abdominal region using 2D projection images. The authors have developed a method for estimating the 3D trajectory of respiratory-induced target motion from CBCT projection images using interdimensional correlation modeling. Methods: Because the superior–inferior (SI) motion of a target can be easily analyzed on projection images of a gantry-mounted CBCT system, the authors investigated the interdimensional correlation of the SI motion with left–right and anterior–posterior (AP) movements while the gantry is rotating. A simple linear model and a state-augmented model were implemented and applied to the interdimensional correlation analysis, and their performance was compared. The parameters of the interdimensional correlation models were determined by least-square estimation of the 2D error between the actual and estimated projected target position. The method was validated using 160 3D tumor trajectories from 46 thoracic/abdominal cancer patients obtained during CyberKnife treatment. The authors’ simulations assumed two application scenarios: (1) retrospective estimation for the purpose of moving tumor setup used just after volumetric matching with CBCT; and (2) on-the-fly estimation for the purpose of real-time target position estimation during gating or tracking delivery, either for full-rotation volumetric-modulated arc therapy (VMAT) in 60 s or a stationary six-field intensity-modulated radiation therapy (IMRT) with a beam delivery time of 20 s. Results: For the retrospective CBCT simulations, the mean 3D root-mean-square error (RMSE) for all 4893 trajectory segments was 0.41 mm (simple linear model) and 0.35 mm (state-augmented model). In the on-the-fly simulations, prior projections over more than 60° appear to be necessary for reliable estimations. The mean 3D RMSE during beam delivery after the simple linear model had established with a prior 90° projection data was 0.42 mm for VMAT and 0.45 mm for IMRT. Conclusions: The proposed method does not require any internal/external correlation or statistical modeling to estimate the target trajectory and can be used for both retrospective image-guided radiotherapy with CBCT projection images and real-time target position monitoring for respiratory gating or tracking.

60 APPLIED LIFE SCIENCES↗

Massive Trajectory Data Based on Patterns of Life

Individual human location trajectory and check-in data have been the driving force for human mobility research in recent years. However, existing human mobility datasets are very limited in size and representativeness. For example, one of the largest and most commonly used datasets of individual human location trajectories, GeoLife, captures fewer than two hundred individuals. To help fill this gap, this Data and Resources paper leverages an existing data generator based on fine-grained simulation of individual human patterns of life to produce large-scale trajectory, check-in, and social network data. In this simulation, individual human agents commute between their home and work locations, visit restaurants to eat, and visit recreational sites to meet friends. We provide large datasets of months of simulated trajectories for two example regions in the United States: San Francisco and New Orleans. In addition to making the datasets available, we also provide instructions on how the simulation can be used to re-generate data, thus allowing researchers to generate the data locally without downloading prohibitively large files.

Amiri, Hossein↗