Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Rocket Lab Venus - Enabling Low-Cost Interplanetary Missions

Rocket Lab’s mission to Venus [1], launching in January 2025, aims to demonstrate that small launch vehicles, such as Electron, and high-energy small spacecraft, such as Photon, can enable a new paradigm of regular, low-cost interplanetary missions. The Electron launch vehicle will deliver the Photon spacecraft carrying the entry probe into low earth orbit, at which point Photon will take over and put both itself and the attached probe on an Earth-Venus transfer trajectory, with assistance from a Lunar flyby. The primary science objective of the mission is to sample the Venusian cloud layers between atitudes of 45 and 60 km above the surface with an autofluorescing nephelometer. The ~1kg scientific instrument will be carried by a small ~17 kg direct entry probe which will separate from the Photon spacecraft approximately 30 minutes prior to atmospheric entry. The probe outer mould line is a scaled down version of the Deep Space 2 probes [2]. NASA’s newly developed 3D Woven Carbon Phenolic, a derivative of the Heatshield for Extreme Entry Environment Technology (HEEET) material [3], is an enabling technology for this mission, and it will comprise the probe forebody heat shield.The probe will communicate directly back to the Earth during its descent via a small on-board radio frequency (RF) antenna. The hyperbolic Venus encounter will see the probe enter the Venusia atmosphere at approximately 11 km/s with an entry flight path angle (EFPA) of about 10°. This relatively low entry angle was selected to increase the duration of the descent phase, reduce the peak deceleration, and reduce the sensitivity of the nominal entry environments to navigational errors. For reference, the Pioneer Venus probes entered at EFPAs varying from about 25° to 70°, resulting in peak decelerations between around 220 and 450 g’s and peak stagnation point heat fluxes ranging from about 40 to 75 MW/m2 [4]. In comparison, the Rocket Lab Venus probe will experience a lower preak deceleration of around 60 g’s and a lower peak stagnation point heat flux of about 15 MW/m2, at the cost of a greater total heat load and correspondingly higher thermal protection system (TPS) mass fraction. This paper recounts the development history of the TPS for the Rocket Lab Venus probe, with a focus on the unique requirements of the mission. In particular, the effect on the TPS design of the mission’s tight budget, short development timeline, slim mass and RF link margins, and mild but long duration entry heating. Rocket Lab’s initial investigations into a ‘hybrid’ TPS [5] based on a scaled version of the Pioneer Venus full-density carbon phenolic forebody shield, and the abandonment of this approach in favour of NASA’s 3D Woven Carbon Phenolic is presented. Additionally, the leveraging of previous testing under the HEEET project at higher conditions and the associated TPS margining strategy that was adopted to avoid the need for extensive mission-specific arc jet testing is discussed. Finally, this paper concludes with a brief consideration of the feasibility of a future low-cost aerocapture technology demonstrator mission based on the 2025 Rocket Lab Venus mission and entry probe.

Lyle Campbell↗

Parametric Analysis of Entry Vehicles for Giant Planet Missions

Summarize concept designs for entry vehicles for giant planet destinations identified as high priority in the latest decadal survey. Identify viable entry states, aerothermal environments, and heatshield thermal protection systems (TPS) for various vehicle dimensions. Viable TPS options and sizing focus on low-g (< 50g) entry conditions to avoid costly instrumentation requalification. TPS manufacturing capabilities are also taken into consideration while adhering to the manufacturing capabilities of the TPS options. Margined mass estimates for heatshield TPS options are provided for Uranus and Saturn test cases.

Giant Planet↗

Thermal Protection System P50 Cork Environments and Response due to Radiative Heating

Space Launch System (SLS) experienced deflagration of the acreage of the Core Stage base heat shield during the Green Run hot-fire test campaigns and Artemis I flight. The burning products from the base heat shield during Green Run hot-fire test operation led to concerns in aerothermal environments and thermal protection system (TPS) performance prior to Artemis I flight. This work documents a highly controlled ground test within the NASA Marshall Space Flight Center’s Nonmetallic Materials Branch thermal vacuum chamber (TVC) and investigates the P50 cork heat transfer environments and thermal protection system (TPS) response due to sensitivity changes in radiative heat rates, ambient pressure, air entrainment mass flow rates, test gas and TPS sample types. An SLS ascent ambient pressure profile was also simulated within the TVC facility. This test data enabled the efforts toward the Artemis I SLS post-flight reconstruction and initial assessment of flight TPS performance. A ground test program was developed to gain an in-depth understanding of the cork combustion dynamics and TPS response due to the SLS launch vehicle flight ascent environments.

thermal protection system↗

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗

Physics-based Entry, Descent and Landing Risk Model

A physics-based risk model was developed to assess the risk associated with thermal protection system failures during the entry, descent and landing phase of a manned spacecraft mission. In the model, entry trajectories were computed using a three-degree-of-freedom trajectory tool, the aerothermodynamic heating environment was computed using an engineering-level computational tool and the thermal response of the TPS material was modeled using a one-dimensional thermal response tool. The model was capable of modeling the effect of micrometeoroid and orbital debris impact damage on the TPS thermal response. A Monte Carlo analysis was used to determine the effects of uncertainties in the vehicle state at Entry Interface, aerothermodynamic heating and material properties on the performance of the TPS design. The failure criterion was set as a temperature limit at the bondline between the TPS and the underlying structure. Both direct computation and response surface approaches were used to compute the risk. The model was applied to a generic manned space capsule design. The effect of material property uncertainty and MMOD damage on risk of failure were analyzed. A comparison of the direct computation and response surface approach was undertaken.

descent and landing↗

Segmentation of Lightweight Ablator Micro-Tomography Using Deep Learning

Ablative thermal protection systems (TPS) are essential for high speed entry of planetary atmospheres, such as those of Earth and Mars. Upon entry the kinetic energy of the spacecraft is converted into thermal energy, leading to high heat fluxes at the wall of the craft. Because of this extreme heating, a robust ablative TPS material must be selected. A common material selection today is phenolic-impregnated carbon ablator (PICA), which is a low-density carbon material known for producing dust that is not suitable to a cleanroom environment. To mitigate dust created by a PICA heatshield, a silicone-based spray called NuSil is applied to the surface of the TPS, creating PICA-NuSil (PICA-N). PICA-N has been observed to have a different material response from regular PICA during high enthalpy flow testing, producing surface temperatures up to 200K less than those seen for PICA [1]. To better understand this phenomenon, it is critical that robust methods of PICA-N material characterization are developed. The purpose of this project is to investigate Object Research Systems’ (ORS) Dragonfly deep learning tools as a means of accurately segmenting and characterizing PICA-N. Systematic testing of this software has shown that Dragonfly deep learning tools have strong potential for accurate segmentation/ characterization of PICA-N and other TPS materials.

Micro-tomography↗

Morphologically-Directed Raman Spectroscopy as an Analytical Method for Subvisible Particle Characterization in Therapeutic Protein Product Quality

Abstract Subvisible particles (SVPs) are a critical quality attribute of injectable therapeutic proteins (TPs) that needs to be controlled due to potential risks associated with drug product quality. The current compendial methods routinely used to analyze SVPs for lot release provide information on particle size and count. However, chemical identification of individual particles is also important to address root-cause analysis. Herein, we introduce Morphologically-Directed Raman Spectroscopy (MDRS) for SVP characterization of TPs. The following particles were used for method development: (1) polystyrene microspheres, a traditional standard used in industry; (2) photolithographic (SU-8); and (3) ethylene tetrafluoroethylene (ETFE) particles, candidate reference materials developed by NIST. In our study, MDRS rendered high-resolution images for the ETFE particles (> 90%) ranging from 19 to 100 μm in size, covering most of SVP range, and generated comparable morphology data to flow imaging microscopy. Our method was applied to characterize particles formed in stressed TPs and was able to chemically identify individual particles using Raman spectroscopy. MDRS was able to compare morphology and transparency properties of proteinaceous particles with reference materials. The data suggests MDRS may complement the current TPs SVP analysis system and product quality characterization workflow throughout development and commercial lifecycle.

Science & Technology - Other Topics↗

Data for Expression of a Bacterial Trehalose 6-Phosphate Synthase Gene otsA in Camelina sativa Seeds Promotes the Channelling of Carbon Towards Oil Accumulation

Improving seed oil yield is essential for developing Camelina sativa as a sustainable biofuel crop. Fatty acid synthesis depends on the production of acetyl-CoA from photosynthetically derived sugars. Trehalose 6-phosphate (T6P), a proxy for sucrose availability, can link sugar status to plant growth and development. Synthesised by trehalose 6-phosphate synthase (TPS) from UDP-glucose and glucose-6-phosphate, T6P plays a regulatory role in metabolism. Our previous studies on Arabidopsis transgenic lines constitutively expressing the E. coli otsA (encoding TPS) showed increased T6P levels and seed triacylglycerol, along with stunted growth. In the present study we express otsA in camelina under the control of a seed-specific Phaseolin promoter. Seeds of the resulting transgenic lines accumulated high levels of T6P, and a 15%–20% increase in total fatty acids and triacylglycerol compared to wild-type. Molecular analysis showed the transgenic seeds had reduced SnRK1 activity, elevated WRI1 protein levels, and increased the levels of WRI1 and its target genes, along with enhanced rates of fatty acid synthesis that increased seed weights relative to wild type. Notably, the increase in oil did not affect seed protein levels but did reduce the soluble metabolite fraction. Crucially, seed-specific expression of otsA mitigated the growth defects associated with constitutive otsA expression, and the transgenic lines showed normal seed development and germination. These findings demonstrate that targeted T6P modulation via seed-specific otsA expression is an effective metabolic engineering strategy to boost oil production in camelina and potentially in other oilseed crops and bioenergy crops such as energycane, sorghum and miscanthus.

Lipids↗

Refurbishment cost study of the thermal protection system of a space shuttle vehicle, phase 2

Labor costs and techniques associated with the refurbishment of representative TPS and their attach concepts suitable for space shuttle application have been identified on the basis of experimental tests. Ablative and reusable surface insulation TPS configurations were designed, fabricated, and tested on a full-scale mockup. The TPS attachment methods investigated included pi-strap, multiple mechanical fasteners, key/keyway, and direct bond concepts. Techniques for performing installation, inspection, repair and replacement of TPS components were studied by examining a variety of shop procedures. Major problem areas associated with these procedures and the designs to which they were applied were analyzed for several significant parameters such as handling, gaskets between joints, repair techniques, ablator plugs, etc. Results of time and motion studies of specific maintenance tasks, simulating operational procedures, were obtained. Using these data, refurbishment labor cost projections were generated for a representative Space Shuttle orbiter.

Haas, D. W.↗

Thermal-Structural Evaluation of TD Ni-20Cr Thermal Protection System Panels

The results of a thermal-structural test program to verify the performance of a metallic/radiative Thermal Protection System (TPS) under reentry conditions are presented. This TPS panel is suitable for multiple reentry, high L/D space vehicles, such as the NASA space shuttle, having surface temperatures up to 1200 C (2200 F). The TPS panel tested consists of a corrugation-stiffened, beaded-skin TD Ni-20Cr metallic heat shield backed by a flexible fibrous quartz and radiative shield insulative system. Test conditions simulated the critical heating and aerodynamic pressure environments expected during 100 repeated missions of a reentry vehicle. Temperatures were measured during each reentry cycle; heat-shield flatness surveys to measure permanent set of the metallic components were made every 10 cycles. The TPS panel, in spite of localized surface failures, performed its designated function.

Eidinoff, H. L.↗

Evaluation of coated columbium for thermal protection systems application

Coated columbium alloys were evaluated for thermal protection system (TPS) application in the maximum operating temperature range from 1370 to 1590 K. Evaluation of materials combinations, subsize panels, and single panel TPS led to the development of a full-size nine-panel TPS array. This array was subjected to simulated shuttle missions of both thermal and acoustic loading. Results are presented which illustrate the structural and thermal adequacy under uniform heating and manufacturability of a full-size coated columbium-alloy TPS which is lightweight, reliable, and reusable.

Rummler, D. R.↗

Thermal performance of a customized multilayer insulation (MLI)

The thermal performance of a LH2 tank on a shroudless vehicle was investigated. The 1.52 m (60 in) tank was insulated with 2 MLI blankets consisting of 18 double aluminized Mylar radiation shields and 19 silk net spacers. The temperature of outer space was simulated by using a cryoshroud which was maintained at near liquid hydrogen temperature. The heating effects of a payload were simulated by utilizing a thermal payload simulator (TPS) viewing the tank. The test program consisted of three major test categories: (1) null testing, (2) thermal performance testing of the tank installed MLI system, and (3) thermal testing of a customized MLI configuration. TPS surface temperatures during the null test were maintained at near hydrogen temperature and during test categories 2 and 3 at 289 K (520R). The heat flow rate through the tank installed MLI at a tank/TPS spacing of 0.457 m was 1.204 watts with no MLI on the TPS and 0.059 watts through the customized MLI with three blankets on the TPS. Reducing the tank/TPS spacing from 0.457 m to 0.152 m the heat flow through the customized MLI increased by 10 percent.

Leonhard, K. E.↗

Aerothermal and structural performance of a cobalt-base superalloy thermal protection system at Mach 6.6

A flightweight, metallic thermal protection system (TPS) applicable to reentry and hypersonic vehicles was subjected to multiple cycles of both radiant and aerothermal heating in order to evaluate its aerothermal performance and structural integrity. Good structural integrity and thermal performance were demonstrated by the TPS under both a radiant and aerothermal heating environment typical of a shuttle entry. The shingle-slip joints effectively allowed for thermal expansion of the panel without allowing any appreciable hot gas flow into the TPS cavity. The TPS also demonstrated good structural ruggedness.

Sawyer, J. W.↗

Study of heat sink thermal protection systems for hypersonic research aircraft

The feasibility of using a single metallic heat sink thermal protection system (TPS) over a projected flight test program for a hypersonic research vehicle was studied using transient thermal analyses and mission performance calculations. Four materials, aluminum, titanium, Lockalloy, and beryllium, as well as several combinations, were evaluated. Influence of trajectory parameters were considered on TPS and mission performance for both the clean vehicle configuration as well as with an experimental scramjet mounted. From this study it was concluded that a metallic heat sink TPS can be effectively employed for a hypersonic research airplane flight envelope which includes dash missions in excess of Mach 8 and 60 seconds of cruise at Mach numbers greater than 6. For best heat sink TPS match over the flight envelope, Lockalloy and titanium appear to be the most promising candidates

Vahl, W. A.↗

Performance of a Haynes 188 metallic standoff thermal protection system at Mach 7

A flight weight, metallic thermal protection system (TPS) model applicable to reentry and hypersonic vehicles was subjected to multiple cycles of both radiant and aerothermal heating to evaluate its aerothermal performance and structural integrity. The TPS was designed for a maximum operating temperature of 1255 K and featured a shingled, corrugation stiffened corrugated skin heat shield of Haynes 188, a cobalt base alloy. The model was subjected to 3 radiant preheat/aerothermal tests for a total of 67 seconds and to 15 radiant heating tests for a total of 85.9 minutes at 1255 K. The TPS limited the primary structure to temperatures below 430 K in all tests. No catastrophic failures occurred in the heat shields, supports, or insulation system. The TPS continued to function even after exposure to a differential temperature 4 times the design value produced thermal buckles in the outer skin. The shingled thermal expansion joint effectively allowed for thermal expansion of the heat shield without allowing any appreciable hot gas flow into the model cavity, even though the overlap gap between shields increased after several thermal cycles.

Avery, D. E.↗

The Shuttle tile story

The structural problems associated with the reusable thermal protection system (TPS) of the Space Shuttle Orbiter are assessed. The ceramic insulation was placed on the aluminum in the form of about 30,000 tiles over approximately 70% of the Orbiter's exterior. The tiles were bonded to felt pads, and then the tile-pad structure was attached to the aluminum skin. As Orbiter design progressed, it was discovered that the TPS would have to withstand loads greater than initially predicted. The group tensile strength was less than that of the individual components. This was the primary factor contributing to the delay of the first flight. Values are given for Orbiter isotherms during a normal flight as well as the corresponding TPS distribution. The complete TPS assemblage is shown schematically, noting the sequence of assembling the tile components into a testing specimen. It is noted that tensile loads are applied to the strain-isolation path at discrete regions along transverse fiber bundles, causing a 50% reduction in system tensile strength. Procedures for strengthening the interface between the insulation and strain-isolation path are discussed and flight-simulation tests are outlined.

Cooper, P. A.↗

A title-gap flow model for use in aerodynamic loads assessment of space shuttle thermal protection system: Parallel gap faces

The problem of predicting aerodynamic loads on the insulating tiles of the space shuttle thermal protection system (TPS) is discussed and seen to require a method for predicting pressure and mass flux in the gaps between tiles. A mathematical model of the tile-gap flow is developed, based upon a slow viscous (Stokes) flow analysis, and is verified against experimental data. The tile-gap pressure field is derived from a solution of the two-dimensional Laplace equation; the mass-flux vector is then calculated from the pressure gradient. The means for incorporating this model into a lumped-parameter network analogy for porous-media flow is given. The means for incorporating this model into a lumped-parameter network analogy for porous-media flow is given. The flow model shows tile-gap mass flux to be very sensitive to the gap width indicating a need for coupling the TPS flow and tile displacement calculation. Analytical and experimental work to improve TPS flow predictions and a possible shuttle TPS hardware modification are recommended.

Dwoyer, D. L.↗

Thermal design of the Space Shuttle External Tank

The history of the engineering and manufacturing requirements leading to the final Thermal Protection System (TPS) for the External Tank (ET) is presented. The thermal design for the ET must be optimized, based on considerations of cost, weight, and application of the TPS. The significant thermal requirements include the structural and component temperature limits, the propellant quality, the minimization of ice and frost, no air liquefaction, and no film boiling. The TPS materials selected to meet the requirements are a low density closed cell foam (CPR-488) and two light-weight ablators (SLA-56 and MA-25s). The first four flights of the Space Shuttle (1981) will measure and evaluate external environmental, structural, propulsion, electrical, and engine performance data. The ET will be instrumented to measure acoustics, pressures, heat transfer, vibration, temperatures, and structural strains. TPS weight reductions are planned for future ETs through the use of a comprehensive thermal instrumentation system.

Warmbrod, J. D.↗