Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Three-dimensional quantitative flow diagnostics

The principles, capabilities, and practical implementation of advanced measurement techniques for the quantitative characterization of three-dimensional flows are reviewed. Consideration is given to particle, Rayleigh, and Raman scattering; fluorescence; flow marking by H2 bubbles, photochromism, photodissociation, and vibrationally excited molecules; light-sheet volume imaging; and stereo imaging. Also discussed are stereo schlieren methods, holographic particle imaging, optical tomography, acoustic and magnetic-resonance imaging, and the display of space-filling data. Extensive diagrams, graphs, photographs, sample images, and tables of numerical data are provided.

Miles, Richard B.↗

Development and applications of nondestructive evaluation at Marshall Space Flight Center

A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.

Whitaker, Ann F.↗

Mechanical response tissue analyzer for estimating bone strength

One of the major concerns for extended space flight is weakness of the long bones of the legs, composed primarily of cortical bone, that functions to provide mechanical support. The strength of cortical bone is due to its complex structure, described simplistically as cylinders of parallel osteons composed of layers of mineralized collagen. The reduced mechanical stresses during space flight or immobilization of bone on Earth reduces the mineral content, and changes the components of its matrix and structure so that its strength is reduced. Currently, the established clinical measures of bone strength are indirect. The measures are based on determinations of mineral density by means of radiography, photon absorptiometry, and quantitative computer tomography. While the mineral content of bone is essential to its strength, there is growing awareness of the limitations of the measurement as the sole predictor of fracture risk in metabolic bone diseases, especially limitations of the measurement as the sole predictor of fracture risk in metabolic bone diseases, especially osteoporosis. Other experimental methods in clinical trials that more directly evaluate the physical properties of bone, and do not require exposure to radiation, include ultrasound, acoustic emission, and low-frequency mechanical vibration. The last method can be considered a direct measure of the functional capacity of a long bone since it quantifies the mechanical response to a stimulus delivered directly to the bone. A low frequency vibration induces a response (impedance) curve with a minimum at the resonant frequency, that a few investigators use for the evaluation of the bone. An alternative approach, the method under consideration, is to use the response curve as the basis for determination of the bone bending stiffness EI (E is the intrinsic material property and I is the cross-sectional moment of inertia) and mass, fundamental mechanical properties of bone.

Arnaud, Sara B.↗

NDE of thermal protection system for space shuttle solid rocket booster

Potential nondestructive test (NDE) methods were evaluated for detecting debonds and weak bonds in the thermal protection system (TPS) for the space shuttle solid rocket boosters. The primary thermal protection material is a sprayable, thick epoxy coating that is filled with lightweight and thermal insulating materials. Test panels were fabricated with a wide variety of hidden realistic defects, including contact debonds and weak bonds. Nondestructive test results were obtained. Candidate NDE methods evaluated for booster production applications include laser interferometry (e.g., electronic shearography), infrared thermography, radiography (e.g., computed tomography), acousto-ultrasonics, mechanical/acoustic impedance, ultrasonics, acoustic emission, and the tap test. Capabilities, advantages, disadvantages, and relative performances in defect detection of each test method for TPS bonding applications are reported. Electronic shearography NDE was technically the superior method for detecting debonds.

Myers, R. S.↗

Tomographic separation of composite spectra. The components of Plaskett's Star

The UV photospheric lines of Plaskett's Star (HD 47129), a 14.4 day period, double lined O-type spectroscopic binary were analyzed. Archival data from IUE (17 spectra well distributed in orbital phase) were analyzed with several techniques. A cross correlation analysis, which showed that the secondary produces significant lines in the UV, indicates that the mass ratio is q = 1.18 + or - 0.12 (secondary slightly more massive). A tomography algorithm was used to produce the separate spectra of the two stars in six spectral regions. The interpolated spectral classifications of the primary and secondary, 07.3 I and 06.2 I, respectively, were estimated through a comparison of UV line ratios with those in spectral standard stars. The intensity ratio of the stars in the UV is 0.53 + or - 0.05 (primary brighter). The secondary lines appear rotationally broadened, and the projected rotational velocity V sin i for this star is estimated to be 310 + or - 20 km/s. The possible evolutionary history of this system is discussed through a comparison of the positions of the components and evolutionary tracks in the H-R diagram.

Bagnuolo, William G., Jr.↗

Solution growth of Triglycine Sulfate (TGS) crystals on the International Microgravity Laboratory (IML-1)

An experiment was planned for the International Microgravity Laboratory (IML-1) to be launched around Feb. 1991. Crystals of triglycine sulfate (TGS) will be grown by low temperature solution crystal growth technique using a multiuser facility called Fluid Experiment System (FES). A special cooled sting technique of solution crystal growth will be used where heat is extracted from the seed crystal through a semi-insulating sting, thereby creating the desired supersaturation near the growing crystal. Also, a holocamera will be used to provide tomography of the three dimensional flow field and particle image displacement velocimetry to monitor the convective flows.

Lal, Ravi B.↗

Synchrotron radiation - Applications in the earth sciences

Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.

Bassett, W. A.↗

Doppler imaging of the dwarf nova U Geminorum

Doppler tomography is applied to time-resolved spectra of the dwarf nova U Geminorum, and it is found that emission from the bright-spot region has neither the velocity of the gas stream nor the velocity of the disk along the stream but lies roughly midway between. It is shown that earlier observations of U Gem were consistent with the present results, and it is concluded that the line emission arises immediately after the shock as the gas from the stream mixes with the disk. The data also show evidence for Balmer emission from the secondary star which, together with the bright spot's emission, produces a complicated S-wave in trailed spectra.

Marsh, Thomas R.↗

Comments on the analysis of returned comet samples

It is argued that returned comet samples should be distributed to individual laboratories for analysis much in the same way that lunar samples are. In the context of emerging technologies, certain developments in other fields which may prove beneficial to the study of comets are reviewed, including cryogenic and tomographic techniques. It is noted that the lack of expertise in the area of cryogenic examination of comet samples is a current weakness in the ability of the extraterrestrial material community to handle comet samples and thus requires further training and preparations. Computer tomography scan images of a 'dirty snowball' are presented to illustrate the importance of developing new methods for comet sample analysis. It is suggested that microanalytic measurements of extraterrestrial samples at the atom-counting limit appear promising for the future.

Walker, Robert M.↗

Using data with models - Ill-posed problems

An attempt is made to show that the combination of data with models leads to a sequence of conventionally ill-posed problems which can be treated in a systematic and practical way by control-theory techniques. The illustrative approach is to exploit the very great mathematical simplifications which result when the methods of finite dimensional vector spaces are used, thus reducing a lot of difficult mathematics to classical least squares. The immediate motivation for this study comes from ocean acoustic tomography.

Wunsch, C.↗

Experimental study of directional solidification of aqueous ammonium chloride solution

Directional solidification experiments have been carried out using the analog casting system of NH4Cl-H2O solution by cooling it from below with a constant-temperature surface ranging from -31.5 C to +11.9 C. The NH4Cl concentration was 26 percent in all solutions, with a liquidus temperature of 15 C. It was found that finger convection occurred in the fluid region just above the mushy layer in all experiments. Plume convection with associated chimneys in the mush occurred in experiments with bottom temperatures as high as +11.0 C. However, when the bottom temperature was raised to +11.9 C, no plume convection was observed, although finger convection continued as usual. A method has been devised to determine the porosity of the mush by computed tomography. Using the mean value of the porosity across the mush layer and the permeability calculated by the Kozeny-Carman relationship, the critical solute Rayleigh number across the mush layer for onset of plume convection was estimated to be between 200 and 250.

Chen, C. F.↗

Tomographic separation of composite spectra - The components of the O-star spectroscopic binary AO Cassiopeiae

The UV photospheric lines of the short-period, double-lined O-star spectroscopic binary AO Cas are analyzed. Archival data from IUE (16 spectra uniformly distributed in orbital phase) were analyzed with a tomography algorithm to produce the separate spectra of the two stars in six spectral regions. The spectral classifications of the primary and secondary, O9.5 III and O8 V, respectively, were estimated through a comparison of UV line ratios with those in spectral standard stars. An intensity ratio of 0.5-0.7 (primary brighter) at 1600 A is compatible with the data.

Bagnuolo, William G., Jr.↗

Ultrasonic nondestructive evaluation of graphite epoxy composite laminates

Quantitative ultrasonic techniques are summarized with applications to the measurement of frequency-dependent attenuation and backscatter and to the NDE of composite laminates. Results are listed for the ultrasonic NDE of graphite-epoxy composite laminates including impact and fatigue damage as well as porosity. The methods reviewed include transmission measurements of attenuation, reconstructive tomography based on attenuation, estimating attenuation from backscattered ultrasound, and backscatter approaches. Phase-sensitive and -insensitive detection techniques are mentioned such as phase cancellation at piezoelectric receiving transducers and acoustoelectric effects. The techniques permit the NDE of the parameters listed in inhomogeneous media and provide both images from the transmission mode and in the reflection mode.

Miller, James G.↗

Tomographic Measurement Of Laser-Bored Holes

Nondestructive technique detects internal variations in arrays of small holes. Inspection method checks laser-bored holes for accuracy. Combines computed tomography and digital laminography. Both types of views made at many parallel planes within plate. System prints out tables of measured and standard deviation of diameter at all planes for each hole.

Willenberg, James D.↗

Electrical impedance imaging in two-phase, gas-liquid flows: 1. Initial investigation

The determination of interfacial area density in two-phase, gas-liquid flows is one of the major elements impeding significant development of predictive tools based on the two-fluid model. Currently, these models require coupling of liquid and vapor at interfaces using constitutive equations which do not exist in any but the most rudimentary form. Work described herein represents the first step towards the development of Electrical Impedance Computed Tomography (EICT) for nonintrusive determination of interfacial structure and evolution in such flows.

Lin, J. T.↗

Comparison of four stable numerical methods for Abel's integral equation

The 3-D image reconstruction from cone-beam projections in computerized tomography leads naturally, in the case of radial symmetry, to the study of Abel-type integral equations. If the experimental information is obtained from measured data, on a discrete set of points, special methods are needed in order to restore continuity with respect to the data. A new combined Regularized-Adjoint-Conjugate Gradient algorithm, together with two different implementations of the Mollification Method (one based on a data filtering technique and the other on the mollification of the kernal function) and a regularization by truncation method (initially proposed for 2-D ray sample schemes and more recently extended to 3-D cone-beam image reconstruction) are extensively tested and compared for accuracy and numerical stability as functions of the level of noise in the data.

Murio, Diego A.↗

Applications of the Strategic Defense Initiative's compact accelerators

The Strategic Defense Initiative's (SDI) investment in particle accelerator technology for its directed energy weapons program has produced breakthroughs in the size and power of new accelerators. These accelerators, in turn, have produced spinoffs in several areas: the radio frequency quadrupole linear accelerator (RFQ linac) was recently incorporated into the design of a cancer therapy unit at the Loma Linda University Medical Center, an SDI-sponsored compact induction linear accelerator may replace Cobalt-60 radiation and hazardous ethylene-oxide as a method for sterilizing medical products, and other SDIO-funded accelerators may be used to produce the radioactive isotopes oxygen-15, nitrogen-13, carbon-11, and fluorine-18 for positron emission tomography (PET). Other applications of these accelerators include bomb detection, non-destructive inspection, decomposing toxic substances in contaminated ground water, and eliminating nuclear waste.

Montanarelli, Nick↗

Analysis, design, and experimental results for lightweight space heat receiver canisters, phase 1

Critical technology experiments have been performed on thermal energy storage modules in support of the Brayton Advanced Heat Receiver program. The modules are wedge-shaped canisters designed to minimize the mechanical stresses that occur during the phase change of the lithium fluoride phase change material. Nickel foam inserts were used in some of the canisters to provide thermal conductivity enhancement and to distribute the void volume. Two canisters, one with a nickel foam insert, and one without, were thermally cycled in various orientations in a fluidized bed furnace. The only measurable impact of the nickel foam was seen when the back and short sides of the canister were insulated to simulate operation in the advanced receiver design. In tests with insulation, the furnace to back side delta T was larger in the canister with the nickel foam insert, probably due to the radiant absorptivity of the nickel. However, the differences in the temperature profiles of the two canisters were small, and in many cases the profiles matched fairly well. Computed Tomography (CT) was successfully used to nondestructively demarcate void locations in the canisters. Finally, canister dimensional stability, which was measured throughout the thermal cycling test program with an inspection fixture was satisfactory with a maximum change of 0.635 mm (0.025 in.).

Schneider, Michael G.↗