Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THALLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Nuclear relaxation in an electric field enables the determination of isotropic magnetic shielding

It is shown that in contrast to the case of nuclear relaxation in a magnetic field B, simultaneous application of the magnetic field B and an additional electric field E causes transverse relaxation of a spin-1/2 nucleus with the rate proportional to the square of the isotropic part of the magnetic shielding tensor. This effect can contribute noticeably to the transverse relaxation rate of heavy nuclei in molecules that possess permanent electric dipole moments. Relativistic quantum mechanical computations indicate that for {sup 205}Tl nucleus in a Pt-Tl bonded complex, Pt(CN){sub 5}Tl, the transverse relaxation rate induced by the electric field is of the order of 1 s{sup −1} at E = 5 kV/mm and B = 10 T.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiopharmaceuticals for SPECT cancer detection

The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Density functional study of the over-doped iron chalcogenide: TlFe2Se2 with ThCr2Si2 structure

We report density functional calculations of electronic structure and magnetic properties of ternary iron chalcogenide TlFe{sub 2}Se{sub 2}, which occurs in the ThCr{sub 2}Si{sub 2} structure and discuss the results in relation to the iron-based superconductors. The ground state is antiferromagnetic with checkerboard order and Fe moment {approx}1.90{micro}{sub B}. There is strong magnetoelastic coupling similar to the Fe-based superconductors, reflected in a sensitivity of the Se position to magnetism. Tl is monovalent in this compound, providing heavy electron doping of 0.5 additional carriers per Fe relative to the parent compounds of the Fe-based superconductors. Other than the change in electron count, the electronic structure is rather similar to those materials. In particular, the Fermi surface is closely related to those of the Fe-based superconductors, except that the electron cylinders are larger, and the hole sections are suppressed. This removes the tendency toward a spin-density wave.

36 MATERIALS SCIENCE↗

Proton-irradiation-induced anomaly in the electrical conductivity of a hydrogen-bonded ferroelastic system

An anomalous abrupt drop in the electrical conductivity has been observed at the ferroelastic phase transition of a proton-irradiated system of hydrogen-bonded TlH{sub 2}PO{sub 4}. As a result of the high-resolution {sup 31}P NMR chemical-shift measurements, distinct changes in the atomic displacements due to the irradiation were identified in the ferroelastic and paraelastic phases. Besides, {sup 1}H NMR spin-spin relaxation measurements revealed a change due to the irradiation in the proton dynamics at the ferroelastic phase transition, apparently accounting for the much-reduced electrical conductivity in the paraelastic phase of the irradiated system.

36 MATERIALS SCIENCE↗

First-forbidden continuum- and bound-state {beta}{sup -}-decay rates of bare {sup 205}Hg{sup 80+} and {sup 207}Tl{sup 81+} ions

We analyze the decay rates {lambda}{sub {beta}{sub c}{sup -}} and {lambda}{sub {beta}{sub b}{sup -}} of the continuum- and bound-state {beta}{sup -}-decays for bare {sup 205}Hg{sup 80+} and {sup 207}Tl{sup 81+} ions. For the ratio of the decay rates R{sub b/c}={lambda}{sub {beta}{sub b}{sup -}}/{lambda}{sub {beta}{sub c}{sup -}} we obtain the values R{sub b/c}=0.161 and R{sub b/c}=0.190 for bare {sup 205}Hg{sup 80+} and {sup 207}Tl{sup 81+} ions, respectively. The theoretical value of the ratio R{sub b/c}=0.190 for the decays of {sup 207}Tl{sup 81+} agrees well with the experimental data R{sub b/c}{sup exp}=0.188(18), obtained at GSI. The theoretical ratio R{sub b/c}=0.161 for {sup 205}Hg{sup 80+} is about 20% smaller than the experimental value R{sub b/c}{sup exp}=0.20(2), measured recently at GSI. We give arguments that the nuclear structure of the nuclei in the {sup 205}Hg{sup 80+}{yields} {sup 205}Tl{sup 81+} transition cannot provide such an enhancement of the ratio. We estimate the values of the continuum- and bound-state {beta}{sup -}-decay rates of the bare {sup 205}Hg{sup 80+} ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculations of the neutron skin and its effect in atomic parity violation

We perform calculations for the neutron skin of nuclei and its contribution to atomic parity nonconservation (PNC) in many isotopes of Cs, Ba, Sm, Dy, Yb, Tl, Pb, Bi, Fr, and Ra. Three problems are addressed: (i) neutron-skin-induced errors to single-isotope PNC, (ii) the possibility of measuring neutron skin using atomic PNC, and (iii) neutron-skin-induced errors for ratios of PNC effects in different isotopes. In the latter case the correlations in the neutron skin values for different isotopes lead to cancellations of the errors; this makes the isotopic ratio method a competitive tool in a search for new physics beyond the standard model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decay of the 9/2{sup -} isomer in {sup 181}Tl and mass determination of low-lying states in {sup 181}Tl, {sup 177}Au, and {sup 173}Ir

A detailed spectroscopic study of the neutron-deficient isotope {sup 181}Tl and the daughter of its {alpha} decay, {sup 177}Au, has been performed in the complete fusion reaction {sup 40}Ca+{sup 144}Sm{yields}{sup 184}Pb* at the velocity filter SHIP (GSI). The mass excess, excitation energy, and decay scheme of the isomeric 1.40(3) ms, 9/2{sup -} intruder state in {sup 181}Tl have been established for the first time. These results solve a long-standing puzzle of the unrealistically large reduced {alpha}-decay width of this isomer. Based on this, the previously unknown masses of the long-lived isomeric states in {sup 177}Au and {sup 173}Ir have been derived. In turn, it now allows the excitation energies of previously identified bands in {sup 177}Au and {sup 173}Ir to be deduced and compared with theoretical predictions. First measurements of {alpha}-decay branching ratios for {sup 181}Tl{sup m} and {sup 177}Au{sup m,g} are also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron activation cross sections on lead isotopes

The cross sections for the reactions {sup 204}Pb(n,n{sup '}{gamma}){sup 204}Pb{sup m}, {sup 204}Pb(n,2n){sup 203}Pb, {sup 204}Pb(n,2n){sup 203}Pb{sup m1}, {sup 204}Pb(n,3n){sup 202}Pb{sup m}, {sup 206}Pb(n,3n){sup 204}Pb{sup m}, {sup 206}Pb(n,{alpha}){sup 203}Hg, and {sup 208}Pb(n,p){sup 208}Tl were determined at the IRMM van de Graaff laboratory in the neutron energy range from 14 to 21 MeV. Both natural and enriched samples were irradiated with neutrons produced via the {sup 3}H(d,n){sup 4}He reaction. The induced activities were determined by gamma-ray spectrometry using a HPGe detector in a low-background shield. Neutron fluences were determined with the well-known cross section of the {sup 27}Al(n,{alpha}){sup 24}Na reaction. Enriched samples were essential to determine the cross sections for the reactions with {sup 204}Pb{sup m} and {sup 206}Pb{sup m} isomers in the final state. Accurate results for reactions with {sup 204,206}Pb as target nuclei with natural lead samples were enabled through a precise measurement of the isotopic ratios. For a first investigation of the consequences of the present data for nuclear reaction models they were confronted with calculations based on global parameter systematics in a phenomenological and in a microscopic approach and with parameters selected to reproduce the available data. The TALYS code was used for the former two calculations involving parameter systematics while the STAPRE code was used for the latter calculation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear structure ''southeast'' of {sup 208}Pb: Isomeric states in {sup 208}Hg and {sup 209}Tl

The nuclear structure of neutron-rich N>126 nuclei has been investigated following their production via relativistic projectile fragmentation of a E/A=1 GeV {sup 238}U beam. Metastable states in the N=128 isotones {sup 208}Hg and {sup 209}Tl have been identified. Delayed {gamma}-ray transitions are interpreted as arising from the decay of I{sup {pi}}=(8{sup +}) and (17/2{sup +}) isomers, respectively. The data allow for the so far most comprehensive verification of the shell-model approach in the region determined by magic numbers Z<82 and N>126.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production of new neutron-rich isotopes of heavy elements in fragmentation reactions of {sup 238}U projectiles at 1A GeV

The production of heavy neutron-rich nuclei has been investigated using cold-fragmentation reactions of {sup 238}U projectiles at relativistic energies. The experiment performed at the high-resolving-power magnetic spectrometer Fragment Separator at GSI made it possible to identify 40 new heavy neutron-rich nuclei: {sup 205}Pt, {sup 207-210}Au, {sup 211-216}Hg, {sup 214-217}Tl, {sup 215-220}Pb, {sup 219-224}Bi, {sup 223-227}Po, {sup 225-229}At, {sup 230,231}Rn, and {sup 233}Fr. The production cross sections of these nuclei were also determined and used to benchmark reaction codes that predict the production of nuclei far from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal Growth, Optical and Scintillation Properties of Eu 2+ -doped TlSr 2 Br 5

Crystals of undoped and Eu 2+ -doped TlSr 2 Br 5 of up to 16 mm in diameter and 50 mm in length were grown by the Vertical Bridgman technique. TlSr 2 Br 5 has the monoclinic crystal structure with space group P21/c. Its density and Z eff are 5.03 g/cm 3 and 58.6, respectively. Radioluminescence spectra of undoped and Eu 2+ -doped TlSr 2 Br 5 feature a broad emission band peaking at about 440 nm for undoped and 520 nm for Eu 2+ -doped crystals. The light yield of undoped TlSr 2 Br 5 is 42,000 ph/MeV, which increases to 55,000 ph/MeV for Eu 2+ -doped crystals. The energy resolution at 662 keV ( 137 Cs) is about 5 – 6% (FWHM). As a result, the scintillation decay of undoped and Eu 2+ -doped TlSr 2 Br 5 is of the order of 100s of nanoseconds.

Bridgman technique↗

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 {mu}m thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water-equivalent path length calibration of a prototype proton CT scanner

Purpose: The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. Methods: A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the calorimeter response for protons of 200 and 100 MeV initial energies undergoing degradation in polystyrene plates of known thickness and relative stopping power (RSP) with respect to water. Calibration curves for the two proton energies were obtained by fitting a second-degree polynomial to the water-equivalent path length versus calorimeter response data. Using the 100 MeV calibration curve, the RSP values for a variety of tissue-equivalent materials were measured and compared to values obtained from a standard depth-dose range shift measurement using a water-tank. A cylindrical water phantom was scanned with 200 MeV protons and its RSP distribution was reconstructed using the 200 MeV calibration. Results: It is shown that this calibration method produces measured RSP values of various tissue-equivalent materials that agree to within 0.5% of values obtained using an established water-tank method. The mean RSP value of the water phantom reconstruction was found to be 0.995 {+-} 0.006. Conclusions: The method presented provides a simple and reliable procedure for calibration of a pCT scanner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.

60 APPLIED LIFE SCIENCES↗

Assessment of radiation dose in nuclear cardiovascular imaging using realistic computational models

Purpose: Nuclear cardiology plays an important role in clinical assessment and has enormous impact on the management of a variety of cardiovascular diseases. Pediatric patients at different age groups are exposed to a spectrum of radiation dose levels and associated cancer risks different from those of adults in diagnostic nuclear medicine procedures. Therefore, comprehensive radiation dosimetry evaluations for commonly used myocardial perfusion imaging (MPI) and viability radiotracers in target population (children and adults) at different age groups are highly desired. Methods: Using Monte Carlo calculations and biological effects of ionizing radiation VII model, we calculate the S-values for a number of radionuclides (Tl-201, Tc-99m, I-123, C-11, N-13, O-15, F-18, and Rb-82) and estimate the absorbed dose and effective dose for 12 MPI radiotracers in computational models including the newborn, 1-, 5-, 10-, 15-yr-old, and adult male and female computational phantoms. Results: For most organs, {sup 201}Tl produces the highest absorbed dose whereas {sup 82}Rb and {sup 15}O-water produce the lowest absorbed dose. For the newborn baby and adult patient, the effective dose of {sup 82}Rb is 48% and 77% lower than that of {sup 99m}Tc-tetrofosmin (rest), respectively. Conclusions: {sup 82}Rb results in lower effective dose in adults compared to {sup 99m}Tc-labeled tracers. However, this advantage is less apparent in children. The produced dosimetric databases for various radiotracers used in cardiovascular imaging, using new generation of computational models, can be used for risk-benefit assessment of a spectrum of patient population in clinical nuclear cardiology practice.

60 APPLIED LIFE SCIENCES↗

Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

60 APPLIED LIFE SCIENCES↗

Dielectric Properties and Electrical Conductivity of ({sub 1–x})TlGaSe{sub 2} · xTm Crystals

We have synthesized samples based on the layered compound TlGaSe{sub 2} and containing thulium: (1–x)TlGaSe{sub 2} · xTm with x = 0.001, 0.005, 0.01, and 0.02. The polycrystalline samples have been used as charges for growing crystals with the corresponding compositions by the Bridgman method. The phase composition of the (1–x)TlGaSe{sub 2} · xTm samples has been determined by X-ray diffraction analysis. Their dielectric properties have been studied in ac electric fields at frequencies in the range f = 5 × 10{sup 4} to 3.5 × 10{sup 7} Hz. We have identified the relaxation character of the dielectric permittivity, the nature of the dielectric loss, and the hopping mechanism of charge transport in the (1–x)TlGaSe{sub 2} · xTm crystals. Our results demonstrate that increasing the thulium concentration in the crystals reduces the mean hop distance and time of charge carriers and increases the ac conductivity and the density of localized states near the Fermi level in the crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗