Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stimulus responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Effects of rotation on the sleep state-dependent midlatency auditory evoked P50 potential in the human

Sopite syndrome, characterized by loss of initiative, sensitivity to normally innocuous sensory stimuli, and impaired concentration amounting to a sensory gating deficit, is commonly associated with Space Motion Sickness (SMS). The amplitude of the P50 potential is a measure of level of arousal, and a paired-stimulus paradigm can be used to measure sensory gating. We used the rotary chair to elicit the sensory mismatch that occurs with SMS by overstimulating the vestibular apparatus. The effects of rotation on the manifestation of the P50 midlatency auditory evoked response were then assessed as a measure of arousal and distractibility. Results showed that rotation-induced motion sickness produced no change in the level of arousal but did produce a significant deficit in sensory gating, indicating that some of the attentional and cognitive deficits observed with SMS may be due to distractibility induced by decreased habituation to repetitive stimuli.

Clinical Trial↗

The Effect of Information Feedback Upon Psychophysical Judgments

An analysis was made of the role of presentation schedules and information feedback on performance in a forced-choice signal detection task. The experimental results indicate that information feedback facilitates performance, but only for certain presentation schedules. The present study was designed to assess performance in a signal detection task under two conditions of information feedback. In the I-condition, S was told on each trial whether his detection response was correct or incorrect; in the !-condition S was given no feedback regarding the correctness of his response. The task involved a 2-response, forced-choice auditory detection problem. On each trial 2 temporal intervals were defined and S was required to report which interval he believed contained the signal; i. e., in one interval a tone burst in a background of white noise was presented, while the other interval contained only white noise. A trial will be denoted as s1 or s2, depending on whether the signal was embedded in the 1st or 2nd interval; the S's response will be denoted A1 or A2 to indicate which interval he reported contained the signal. The probability of an s1 trial will be denoted as y. In this study two values of y were used (.50 and.75) and, as indicated above, two conditions of information feedback. Thus there were 4 experimental conditions (501, · 50I, 751, 75I); each S was run under all 4 conditions. Method Gaussian noise was presented binaurally in S's headphones throughout a test session and the signal was a 1000-cps sinusoid tone; the tone was presented for 100 msec. including equal fall and rise times of 20 msec. The ratio of signal energy to noise power in a unit bandwidth was 2.9, and was constant throughout the study. The. S was seated before a stimulus display board. On each trial a red warning light was flashed for 100 msec. Two amber lights then came on successively each for 1 sec.; these lights defined the 2 observation intervals. The onset of the signal occurred 500 msec. after the onset of one of the observation intervals. After the second amber light went off, S indicated his response by pressing 1 of 2 wand switches under cards reading "1st interval" and "2nd interval." For the !-condition a green light flashed on above the correct response key after S's response; the green light was omitted in the !-condition. Each trial lasted 6 sec. The S's were 12 male college students with normal hearing. They were run for two practice sessions followed by 20 test sessions. Test sessions were run on consecutive days, 350 trials/day. Each day S ran on 1 of the 4 experimental conditions; in successive 4-day blocks S ran one day on each of the 4 experimental conditions in a random order. Thus, over 20 days each of the experimental conditions was repeated 5 times.

Atkinson, Richard C.↗

Ocular counterrolling measured during eight hours of sustained body tilt

Adaptation of otolith organ activity was investigated by monitoring the ocular counterrolling response of four normal individuals and three persons with severe bilateral loss of labyrinthine function. Several eye photographs were recorded every 30 minutes during a period of 8 hours in which the subject was held in a lateral tilt (60 deg) position. The recorded eye roll position varied to an expected small extent within each test session; this variation about a given mean roll position was similar among the test sessions for all subjects. The mean roll position, on the other hand, changed from session to session in substantial amounts, but these changes appeared to be random with respect to time and among subjects. Furthermore, the intersessional variation in the mean torsional eye position of the normal subjects was equivalent to that of the labyrinthine-defective subjects who displayed little or no counterrolling. These results suggest that the human counterrolling response is maintained either by essentially nonadapting macular receptors or by extremely fine movements of the head in the gravitational field, such as may have been allowed by the biteboard/headrest restraint system used in this study, which served as an everchanging accelerative stimulus.

Miller, E. F., II↗

Oculometric Detection and Characterization of Sub-Clinical Visual/Visuomotor Impairment

It has long been known that qualitative abnormalities in eye movements can be used to diagnose overt brain pathologies (Diefendorf & Dodge, 1908; Fox & Holmes, 1926; Leigh & Zee, 2015). Here, we will examine the use of a set of quantitative measures of the human behavioral response (oculometrics) in a 5-minute radial ocular tracking task (Krukowski & Stone, 2005) with sufficient temporal, spatial, and directional uncertainty to minimize the contribution of a priori prediction or anticipation, and to emphasize the use of a posteriori visual processing of the stimulus trajectory (Liston & Stone, 2014). The derived oculometrics provide a largely independent, reliable set of metrics that are sensitive enough to detect mild sub-clinical impairment across a range of possible neural loci (Stone et al., 2019) with the pattern of impairment across the set providing specificity as to its nature (Tyson et al., 2023). We will review our earlier findings where oculometrics have been used to detect mild impairment due to traumatic brain injury, sleep loss, and low-dose alcohol (Liston et al., 2017; Stone et al., 2019; Tyson et al., 2021). We will also report on a recent clinical study of asymptomatic patients at risk of retinal pathology (Leung et al., 2022) and show that oculometrics can detect and characterize substantive loss of visual function in the absence of clinical indicators of pathology. We conclude that oculometric testing could be used as a routine non-invasive ophthalmological or neurological tool to aid in the early detection and diagnosis of neural injury, toxicity, or disease.

eye movements↗

The Role of Nuclear Cytoskeleton in the Osteocytic Response to Simulated Weightlessness

While in space, astronauts exercise frequently to combat bone and muscle loss due to weightlessness. This loss in bone can lead to serious health problems, such as increased fracture risk. Osteocytes are known to play a vital role in bone resorption and formation. It is also theorized that osteocytes act as the mechanosensors of bone, detecting mechanical stimulus and relaying these signals to surrounding cells. Previous research suggests that, during space flight, osteocytes exhibit matrix remodeling and resorption capabilities (osteocytic osteolysis) leading to an enlargement of the lacunae and contributing to overall bone degradation. The intercellular causes of these changes has not yet been determined. LINC or Linker of Nucleoskeleton and Cytoskeleton is a protein complex that forms a connection between the nucleus and cytoskeleton. LINC serves as a way to transmit mechanical signals to the nucleus and is also involved in the regulation of Wnt signaling via KASH proteins (Nesprin -1 and Nesprin -2). Wnt signaling in osteocytes assists with bone homeostasis and perturbed Wnt signaling can lead to bone loss. This suggests that LINC may contribute to the bone diminishing effects of microgravity. Therefore, we hypothesize that the disruption of LINC or LINC components by simulated microgravity (using the hindlimb unloading model, HU) affects Wnt signaling in osteocytes affecting bone formation and leading to increased osteocyte lacunar size. To test these hypotheses, we plan to conduct an animal study using 16 week old male mice (n6group). The mice will undergo HU for up to 7 days. After the desired time point, we will utilize quantitative real-time PCR techniques to determine the changes in gene expression of seven LINC complex genes (Sun -1, Sun -2, Nesprin -1, Nesprin -2, Lamin AC, Lamin B, and Emerin) and genes related to bone formation and osteocyte signaling. To determine changes osteocytic remodeling activity we will immunostain for osteocyte markers (Dmp-1 and Sost) and osteolysis markers (TRAP, MMPs) and measure lacunar size.

Touchstone, Hallie↗

The auditory neural network in man

The principles of anatomy and physiology necessary for understanding brain wave recordings made from the scalp are briefly discussed. Brain waves evoked by sounds are then described and certain of their features are related to the physical aspects of the stimulus and the psychological state of the listener. It is proposed that data obtained through probes located outside the head can reveal a large amount of detail about brain activity. It is argued that analysis of such records enables one to detect the response of the nervous system to an acoustic message at the moment of its inception at the ear, and to follow the progress of the acoustic message up through the various brain levels as progressively more complex operations are performed upon it. Even those brain events responsible for the highest level of signal processing - distinguishing between similar signals and making decisions about them - seem to generate characteristic and identifiable electrical waves.

Galambos, R.↗

Touch and gravitropic set-point angle interact to modulate gravitropic growth in roots

Plant roots must sense and respond to a variety of environmental stimuli as they grow through the soil. Touch and gravity represent two of the mechanical signals that roots must integrate to elicit the appropriate root growth patterns and root system architecture. Obstacles such as rocks will impede the general downwardly directed gravitropic growth of the root system and so these soil features must be sensed and this information processed for an appropriate alteration in gravitropic growth to allow the root to avoid the obstruction. We show that primary and lateral roots of Arabidopsis do appear to sense and respond to mechanical barriers placed in their path of growth in a qualitatively similar fashion. Both types of roots exhibited a differential growth response upon contacting the obstacle that directed the main axis of elongation parallel to the barrier. This growth habit was maintained until the obstacle was circumvented, at which point normal gravitropic growth was resumed. Thus, the gravitational set-point angle of the primary and lateral roots prior to encountering the barrier were 95 degrees and 136 degrees respectively and after growing off the end of the obstacle identical set-point angles were reinstated. However, whilst tracking across the barrier, quantitative differences in response were observed between these two classes of roots. The root tip of the primary root maintained an angle of 136 degrees to the horizontal as it traversed the barrier whereas the lateral roots adopted an angle of 154 degrees. Thus, this root tip angle appeared dependent on the gravitropic set-point angle of the root type with the difference in tracking angle quantitatively reflecting differences in initial set-point angle. Concave and convex barriers were also used to analyze the response of the root to tracking along a continuously varying surface. The roots maintained the a fairly fixed angle to gravity on the curved surface implying a constant resetting of this tip angle/tracking response as the curve of the surface changed. We propose that the interaction of touch and gravity sensing/response systems combine to strictly control the tropic growth of the root. Such signal integration is likely a critical part of growth control in the stimulus-rich environment of the soil. c2003 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Discipline Plant Biology↗

Interocular velocity difference contributes to stereomotion speed perception

Two experiments are presented assessing the contributions of the rate of change of disparity (CD) and interocular velocity difference (IOVD) cues to stereomotion speed perception. Using a two-interval forced-choice paradigm, the perceived speed of directly approaching and receding stereomotion and of monocular lateral motion in random dot stereogram (RDS) targets was measured. Prior adaptation using dysjunctively moving random dot stimuli induced a velocity aftereffect (VAE). The degree of interocular correlation in the adapting images was manipulated to assess the effectiveness of each cue. While correlated adaptation involved a conventional RDS stimulus, containing both IOVD and CD cues, uncorrelated adaptation featured an independent dot array in each monocular half-image, and hence lacked a coherent disparity signal. Adaptation produced a larger VAE for stereomotion than for monocular lateral motion, implying effects at neural sites beyond that of binocular combination. For motion passing through the horopter, correlated and uncorrelated adaptation stimuli produced equivalent stereomotion VAEs. The possibility that these results were due to the adaptation of a CD mechanism through random matches in the uncorrelated stimulus was discounted in a control experiment. Here both simultaneous and sequential adaptation of left and right eyes produced similar stereomotion VAEs. Motion at uncrossed disparities was also affected by both correlated and uncorrelated adaptation stimuli, but showed a significantly greater VAE in response to the former. These results show that (1) there are two separate, specialised mechanisms for encoding stereomotion: one through IOVD, the other through CD; (2) the IOVD cue dominates the perception of stereomotion speed for stimuli passing through the horopter; and (3) at a disparity pedestal both the IOVD and the CD cues have a significant influence.

Vision, Binocular/physiology↗

Light regulation of the growth response in corn root gravitropism

Roots of Merit variety corn (Zea mays L.) require red light for orthogravitropic curvature. Experiments were undertaken to identify the step in the pathway from gravity perception to asymmetric growth on which light may act. Red light was effective in inducing gravitropism whether it was supplied concomitant with or as long as 30 minutes after the gravity stimulus (GS). The presentation time was the same whether the GS was supplied in red light or in darkness. Red light given before the GS slightly enhanced the rate of curvature but had little effect on the lag time or on the final curvature. This enhancement was expanded by a delay between the red light pulse and the GS. These results indicate that gravity perception and at least the initial transduction steps proceed in the dark. Light may regulate the final growth (motor) phase of gravitropism. The time required for full expression of the light enhancement of curvature is consistent with its involvement in some light-stimulated biosynthetic event.

NASA Discipline Number 40-50↗

Yaw sensory rearrangement alters pitch vestibulo-ocular reflex responses

Ten male subjects underwent two types of adaptation paradigm designed either to enhance or to attenuate the gain of the canal-ocular reflex (COR), before undergoing otolith-ocular reflex (OOR) testing with constant velocity, earth horizontal axis and pitch rotation. The adaptation paradigm paired a 0.2 Hz sinusoidal rotation about an earth vertical axis with a 0.2 Hz optokinetic stimulus that was deliberately mismatched in peak velocity or phase and was designed to produce short-term changes in the COR. Preadaptation and postadaptation OOR tests occurred at a constant velocity of 60 degrees/sec in the dark and produced a modulation component of the slow phase velocity with a frequency of 0.16 Hz due to otolithic stimulation by the sinusoidally changing gravity vector. Of the seven subjects who showed enhancement of the COR gain, six also showed enhancement of the OOR modulation component. Of the seven subjects who showed attenuation of the COR gain, five also showed attenuation of the OOR modulation component. The probability that these two cross-axis adaptation effects would occur by chance is less than 0.02. This suggests that visual-vestibular conditioning of the yaw axis COR also induced changes in the pitch axis OOR. We thus postulate that the central nervous system pathways that process horizontal canal yaw stimuli have elements in common with those processing otolithic stimuli about the pitch axis.

NASA Discipline Neuroscience↗

Orientation processing mechanisms revealed by the plaid tilt illusion

The tilt after-effect (TAE) and tilt illusion (TI) have revealed a great deal about the nature of orientation coding of 1-dimensional (1D) lines and gratings. Comparatively little research however has addressed the mechanisms responsible for encoding the orientation of 2-dimensional (2D) plaid stimuli. A multi-stage model of edge detection has recently been proposed [Georgeson, M. A. (1998) Image & Vision Computing, 16(6-7), 389-405] to account for the perceived structure of a plaid stimulus that incorporates extraction of the zero-crossings (ZCs) of the plaid. Data is presented showing that the ZCs of a plaid inducing stimulus can interact with vertical grating test stimulus to induce a standard tilt illusion. However, by considering the second-order structure of a plaid rather than ZCs, it was shown that the perceived orientation of the vertical test grating results from the combination of orientation illusions due to the first- and second-order components of an inducing plaid. The data suggest that the mechanisms encoding the orientation of second-order contours are similar to, and interact directly with, those that encode first-order contours.

Orientation/physiology↗

Translational Vestibulo-Ocular Reflexes During Off-Vertical Axis Rotation

The translational vestibulo-ocular reflex (tVOR) is an otolith-mediated response that stabilizes near vision during linear acceleration at higher frequencies where visually mediated reflexes are not adequate. The modulation of horizontal and vergence eye movements during Off-Vertical Axis Rotation (OVAR) are presumed to reflect the tVOR in response to the continuously varying linear acceleration in the interaural and nasooccipital axes, respectively. The purpose of this study was to examine the effect of frequency and fixation distance on the modulation of slow phase eye velocity (SPV) as further evidence that the tVOR is elicited during OVAR. Eighteen subjects were rotated about their longitudinal axis tilted by 30 deg off-vertical. Rotational velocities varied between 18 and 288 deg/sec corresponding to a frequency range of 0.05 to 0.8 Hz. Fixation distance was altered by asking subjects to imagine stationary targets that were briefly presented at 0.5, 1 and 2 m during some rotation cycles. The target flash was 40 msec in the nose-up position at eye level. Oculomotor responses were recorded in the dark using infrared binocular videography. Sinusoidal curve fits were used to derive amplitude, phase and bias velocity of the eye movements across multiple rotation cycles. Consistent with previous studies, the modulation of both horizontal and vergence SPV increased with stimulus frequency. The effect of fixation distance was negligible at lower frequencies. The modulation of horizontal and vergence SPV was; however, proportional to fixation distance during OVAR at 0.8 Hz. This increasing sensitivity and dependence on fixation distance of horizontal and vergence SPV during OVAR is consistent with tVOR characteristics measured during other types of linear motion. We conclude that the modulation of horizontal and vergence SPV will be diagnostically more useful at higher stimulus frequencies where the tVOR is more robust.

Wood, Scott J.↗

Integration of a Finite Element Model with the DAP Bone Remodeling Model to Characterize Bone Response to Skeletal Loading

NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.

Bone Remodeling↗

Refinement of a limit cycle oscillator model of the effects of light on the human circadian pacemaker

In 1990, Kronauer proposed a mathematical model of the effects of light on the human circadian pacemaker. Although this model predicted many general features of the response of the human circadian pacemaker to light exposure, additional data now available enable us to refine the original model. We first refined the original model by incorporating the results of a dose response curve to light into the model's predicted relationship between light intensity and the strength of the drive onto the pacemaker. Data from three bright light phase resetting experiments were then used to refine the amplitude recovery characteristics of the model. Finally, the model was tested and further refined using data from an extensive phase resetting experiment in which a 3-cycle bright light stimulus was presented against a background of dim light. In order to describe the results of the four resetting experiments, the following major refinements to the original model were necessary: (i) the relationship between light intensity (I) and drive onto the pacemaker was reduced from I1/3 to I0.23 for light levels between 150 and 10,000 lux; (ii) the van der Pol oscillator from the original model was replaced with a higher-order limit cycle oscillator so that amplitude recovery is slower near the singularity and faster near the limit cycle; (iii) a direct effect of light on circadian period (tau x) was incorporated into the model such that as I increases, tau x decreases, which is in accordance with "Aschoff's rule". This refined model generates the following testable predictions: it should be difficult to enhance normal circadian amplitude via bright light; near the critical point of a type 0 phase response curve (PRC) the slope should be steeper than it is in a type 1 PRC; and circadian period measured during forced desynchrony should be directly affected by ambient light intensity.

NASA Discipline Regulatory Physiology↗

Space flight and the skeleton: lessons for the earthbound

Loss of bone during extended space flight has long been a concern that could limit the ability of humans to explore the universe. Surprisingly, the available data do not support the concept that weightlessness leads inexorably to a depleted skeleton unable to withstand the stress of a return to a 1-g environment. Nevertheless, some bone loss does occur, especially in those bones most stressed by gravity prior to flight, which provides confirmation of the proposal formulated over a century ago by Julius Wolff that mechanical stress determines the form and function of bone. Although the phenomenon of bone loss with skeletal unloading, whether by space flight or immobilization or just taking a load off your feet (literally) is well established, the mechanisms by which bone senses load and adjusts to it are not so clear. What actually is the stimulus, and what are the sensors? What are the target cells? How do the sensors communicate the message into the cells, and by what pathways do the cells respond? What is the role of endocrine, factors vs. paracrine or autocrine factors in mediating or modulating the response? None of these questions has been answered with certainty, but, as will become apparent in this review, we have some clues directing us to the answers. Although the focus of this review concerns space flight, it seems highly likely that the mechanisms mediating the transmission of mechanical load to changes in bone formation and resorption apply equally well to all forms of disuse osteoporosis and are likely to be the same mechanisms affected by other etiologies of osteoporosis.

unmanned↗