10 K Ring Electrode Trap - Tandem Mass Spectrometer for Infrared Spectroscopy of Mass Selected Ions

A novel instrumental setup for measuring infrared photodissociation spectra of buffer gas cooled, mass-selected ions is described and tested. It combines a cryogenically cooled, linear radio frequency ion trap with a tandem mass spectrometer, optimally coupling continuous ion sources to pulsed laser experiments. The use of six independently adjustable DC potentials superimposed over the trapping radio frequency field provides control over the ion distribution within, as well as the kinetic energy distribution of the ions extracted from the ion trap. The scheme allows focusing the ions in space and time, such that they can be optimally irradiated by a pulsed, widely tunable infrared photodissociation laser. Ion intensities are monitored with a time-of-flight mass spectrometer mounted orthogonally to the ion trap axis.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mass- and energy-analyses of ions from plasma by means of a miniature Thomson spectrometer

The paper presents an improved version of a miniature mass-spectrometer of the Thomson-type, which has been adopted for ion analysis near the dense plasma region inside a vacuum chamber. Problems connected with the separation of ions from plasma streams are considered. Input diaphragms and pumping systems, needed to ensure good vacuum inside the analyzing region, are described. The application of the miniature Thomson-type analyzer is illustrated by ion parabolas recorded in plasma-focus facility and rod plasma injector experiment. A quantitative analysis of the recorded ion parabolas is presented. Factors influencing accuracy of the ion analysis are discussed and methods of the spectrometer calibration are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performances of a bent-crystal spectrometer adapted to resonant x-ray emission measurements on gas-phase samples

We describe a bent-crystal spectrometer adapted to measure x-ray emission resulting from core-level excitation of gas-phase molecules in the 0.8-8 keV energy range. The spectrometer is based on the Johann principle, and uses a microfocused photon beam to provide high-resolution (resolving power of {approx}7500). A gas cell was designed to hold a high-pressure (300 mbar) sample of gas while maintaining a high vacuum (10{sup -9} mbar) in the chamber. The cell was designed to optimize the counting rate (2000 cts/s at the maximum of the Cl K{alpha} emission line), while minimizing self-absorption. Example of the K{alpha} emission lines of CH{sub 3}Cl molecules is presented to illustrate the capabilities of this new instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory

The International X-Ray Observatory (IXO) is under formulation by NASA, ESA and JAXA for deployment in 2022. IXO emerged over the last 18 months as the NASA Constellation-X and ESA/JAXA X-Ray Evolving Universe Spectrometer (XEUS) missions were combined. The driving performance requirements for the X-Ray Microcalorimeter Spectrometer (XMS) are a spectral resolution of 2.5 eV over the central 2'x2' in the 0.3-7.0 keV band, and 10 eV to the edge of the 5'x5' field of view (FOV). The XMS is now based on a microcalorimeter array of Transition-Edge Sensor (TES) thermometers with Au/Bi absorbers and a SQUID MUX readout. One of the concepts studied as part of the mission formulation has a core 40x40 array corresponding to a 2'x2' FOV with 3'' pixels surrounded by an outer, annular 52x52 array of 6'' pixels that extends the field of view to 5.4'x5.4' with better than 10 eV resolution. There are several options for implementing the readout and cooling system of the XMS under study in the US, Europe and Japan. The ADR system will have from two to five stages depending on the performance of the cryocooler. Mechanical coolers with sufficient cooling power at 4K are available now, and {approx}2K coolers are under development. In this paper we give an overview of the XMS instrument, and some of the tradeoffs to be addressed for this observatory instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Astro-H Soft X-ray Spectrometer (SXS)

The Soft-X-ray Spectrometer (SXS) is a high spectral resolution, cryogenic x-ray spectrometer that will fly on the Japan/U.S. Astro-H observatory in 2014. The SXS is composed of a 36 pixel, imaging, x-ray calorimeter array that will operate at 0.05 K utilizing a 2-stage adiabatic demagnetization refrigerator and a redundant pre-cooler design using both a 40 liter liquid helium tank and a 1.7 K Joule-Thomson (JT) cryocooler. Additional redundant Stirling cycle coolers provide pre-cooling for the (JT) and cool the outer thermal shields for the JT and the helium tank. The detector system, while similar to that flown on Suzaku, is composed of larger 0.81x0.81mm pixels, but has significantly better performance, currently predicted to be better than 4 eV FWHM at 6 keV with 95% quantum efficiency. This instrument is the result of a close collaboration between many institutions in the U.S. and Japan over the last 25 years. Here we will present an overview of the SXS instrument, the SXS cooling system, and recent laboratory improvements to the detector system.0.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 {mu}s. Accordingly, the sample is under excitation in 10{sup -4} part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 10{sup 10} V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of multiwavelength-range fine-resolution spectrometer for hydrogen emissions and its application to large helical device periphery plasmas

We developed a spectrometer specialized for simultaneous observation of the hydrogen Balmer-{alpha}, -{beta}, -{gamma} lines and the Fulcher-{alpha} v'=v''=2 rovibronic transition band. The spectrometer was optimized for the light input coupled by nine optical fibers having 400 {mu}m core diameters. The spectral resolutions were 0.02-0.03 nm for these wavelength ranges at the entrance slit width of 20 {mu}m. The polarization resolved spectra of these emissions from the peripheral region of large helical device (LHD) plasmas were measured simultaneously and showed the polarization dependence coming from the magnetic field in the LHD plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elementary Ion Optics with Applications to Electromagnetic Spectrometers

This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

43 PARTICLE ACCELERATORS↗

A rotatable electron spectrometer for multicoincidence experiments

We have developed a rotatable hemispherical spectrometer with good energy and angular resolution, which can be positioned with the lens axis arbitrarily within a solid angle of 1 {pi}. The collection angle of the emitted electrons with respect to the polarization axis of the light is set by means of a three-axes goniometer, operating under vacuum. An important requirement for this setup was the possibility to perform coincidences between the electron analyzed by the spectrometer and one or several other particles, such as ions, electrons, or photons. The lens system and the hemispheres have been designed to accommodate such experimental demands, regarding parameters such as the resolving power, the acceptance angle, or the width of the kinetic energy window which can be recorded for a given pass energy. We have chosen to detect the impact position of the electron at the focal plane of the hemispherical analyzer with a delay line detector and a time-to-digital converter as acquisition card rather than using a conventional charge-coupled device camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new all-digital time differential {gamma}-{gamma} angular correlation spectrometer

A new digital time differential perturbed angular correlation spectrometer, designed to measure the energy of and coincidence time between correlated detector signals, here correlated {gamma} photons, is presented. The system overcomes limitations of earlier digital approaches and features improved performance and handling. By consequently separating the data recording and evaluation, it permits the simultaneous measurement of decays with several {gamma}-ray cascades at once and avoids the necessity of premeasurement configuration. Tests showed that the spectrometer reaches a time resolution of 460 ps [using a {sup 60}Co sample and Lu{sub 1.8}Y{sub 0.2}SiO{sub 5}:Ce (LYSO) scintillators, otherwise better than 100 ps], an energy resolution that is equivalent to the limit of the used scintillation material, and a processing capability of more than 200 000 {gamma} quanta per detector and second. Other possible applications of the presented methods include nuclear spectroscopy, positron emission tomography, time of flight studies, lidar, and radar.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transmission grating based extreme ultraviolet imaging spectrometer for time and space resolved impurity measurements

A free standing transmission grating based imaging spectrometer in the extreme ultraviolet range has been developed for the National Spherical Torus Experiment (NSTX). The spectrometer operates in a survey mode covering the approximate spectral range from 30 to 700 A and has a resolving capability of {delta}{lambda}/{lambda} on the order of 3%. Initial results from space resolved impurity measurements from NSTX are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection Efficiency of a ToF Spectrometer from Heavy-Ion Elastic Recoil Detection

The detection efficiency of a time-of-flight system based on two micro-channel plates (MCP) time zero detectors plus a conventional silicon surface barrier detector was obtained from heavy ion elastic recoil measurements (this ToF spectrometer is mainly devoted to measurements of total fusion cross section of weakly bound projectiles on different mass-targets systems). In this work we have used beams of {sup 7}Li, {sup 16}O, {sup 32}S and {sup 35}Cl to study the mass region of interest for its application to measurements fusion cross sections in the {sup 6,7}Li+{sup 27}Al systems at energies around and above the Coulomb barrier (0.8V{sub B{<=}}E{<=}2.0V{sub B}). As the efficiency of a ToF spectrometer is strongly dependent on the energy and mass of the detected particles, we have covered a wide range of the scattered particle energies with a high degree of accuracy at the lowest energies. The different experimental efficiency curves obtained in that way were compared with theoretical electronic stopping power curves on carbon foils and were applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of multi-channel electron spectrometer

In order to obtain the angular dependent electron energy distributions, we developed a multichannel electron spectrometer (MCESM) with high energy and angular resolutions. The MCESM consists of seven small electron spectrometers set in every 5 deg. on the basement, each of which detection range is up to 25 MeV. In the experiment, we successfully obtained electron spectra from imploded cone-shell target as well as gold plane target irradiated by ultraintense (300 J/5 ps) laser beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High accuracy wavelength calibration for a scanning visible spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies {<=}0.2 A. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of {approx}0.25 A has been demonstrated. With the addition of a high resolution (0.075 arc sec) optical encoder on the grating stage, greater precision ({approx}0.005 A) is possible, allowing absolute velocity measurements within {approx}0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device

A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar{sup 16+} and will provide ion temperature profiles with spatial and temporal resolutions of <2 cm and {>=}10 ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of the Johann error for spherically bent x-ray imaging crystal spectrometers

New x-ray imaging crystal spectrometers, currently operating on Alcator C-Mod, NSTX, EAST, and KSTAR, record spectral lines of highly charged ions, such as Ar{sup 16+}, from multiple sightlines to obtain profiles of ion temperature and of toroidal plasma rotation velocity from Doppler measurements. In the present work, we describe a new data analysis routine, which accounts for the specific geometry of the sightlines of a curved-crystal spectrometer and includes corrections for the Johann error to facilitate the tomographic inversion. Such corrections are important to distinguish velocity induced Doppler shifts from instrumental line shifts caused by the Johann error. The importance of this correction is demonstrated using data from Alcator C-Mod.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ITER core imaging x-ray spectrometer: X-ray calorimeter performance

We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗