Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

MPS dose reconstruction for internal emitters: some site-specific issues and approaches

Background: As part of the Million Person Study (MPS), dose reconstructions for internal emitters have been performed for several U.S. facilities where large quantities of radionuclides were handled. The main challenges and dominant sources of potential error in retrospective dose estimates for internally exposed workers have been found to vary from site to site. Here in this paper, we discuss some important issues encountered in dose reconstructions performed for selected MPS sites and the approaches used to address those issues. The focus is on some foundational components of retrospective dose assessments that have received little attention in the literature. Methods: The discussion is built around illustrative exposure data and dose reconstructions for workers at selected facilities addressed in the MPS. Related findings at some non-MPS sites are also discussed. Results: Each of the following items has been found to be a major source of potential error in reconstructed tissue doses for some MPS sites: identification of all dosimetrically important internal emitters; the time pattern of intake; the mode(s) of intake; reliability of bioassay measurements; application of surrogate (coworker) information in lieu of, or in conjunction with, worker-specific monitoring data; the chemical and physical forms of inhaled radionuclide; and the relation of air monitoring data to actual intake. Conclusions: (1) Much of the dose reconstruction effort for internal emitters should be devoted to development of best feasible exposure scenarios. (2) Coworker data should be used to assign exposure scenarios or dose estimates to workers with missing exposure data only if there is compelling evidence of similar coworker exposure. (3) Bioassay data for some radionuclides and periods of operation at MPS sites are of questionable reliability due to sizable uncertainties associated with contamination, recovery, or background issues. (4) Dose estimates derived solely from air monitoring data should be treated as highly uncertain values in the absence of site-specific information demonstrating that the data are reasonably predictive of intake. (5) For intakes known or assumed to be via inhalation, the uncertainty in lung dose typically is much greater than the uncertainty in dose to systemic tissues, when dose estimates are based on urinary excretion data. (6) The lung dose estimate often can be improved through development of site-specific respiratory absorption parameter values. (7) There is generally insufficient site-specific information to justify development of site-specific systemic models.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stock-Specific Size and Timing at Ocean Entry of Columbia River Juvenile Chinook Salmon and Steelhead: Implications for Early Ocean Growth

Abstract Juvenile salmon transitioning from freshwater to marine environments experience high variation in growth and survival, yet the specific causes of this variation are poorly understood. Size at and timing of ocean entry may contribute to this variation because they influence both the availability of prey and vulnerability to predators. To explore this issue, we used stock assignments based on genetic stock identification and internal tags to document the stock-specific size and timing of juvenile hatchery and presumed wild Columbia River Chinook Salmon Oncorhynchus tshawytscha and steelhead O. mykiss at ocean entry during 2007–2011. We found that juvenile salmon and steelhead had consistent stock-specific capture dates, with lower-river stocks typically having earlier timing than those originating farther upstream. Mean size also varied among stocks and was related to hatchery practices. Hatchery yearling Chinook Salmon and steelhead were consistently larger than wild fish from the same stocks, although timing in the estuary was similar. In contrast, hatchery subyearling Chinook Salmon were of similar size to wild fish but entered the ocean up to a month earlier. We evaluated the potential importance of these traits on early marine growth by estimating stock-specific growth rates for Chinook Salmon caught in estuarine and ocean habitats. Growth rates were related to relative ocean entry timing, with lower growth rates for stocks that had only recently arrived in marine waters. Our results demonstrate that stocks within a single basin can differ in their size and timing of ocean entry, life history traits that contribute to early marine growth and potentially to the survival of juvenile salmon. Our results also highlight the necessity of considering stock-specific variation in life history traits to understand salmon ecology and survival across the entire life cycle. Received January 16, 2015; accepted April 28, 2015

Weitkamp, Laurie A.↗

Engineering sensitivity and specificity of AraC-based biosensors responsive to triacetic acid lactone and orsellinic acid

Abstract We previously described the design of triacetic acid lactone (TAL) biosensor ‘AraC-TAL1’, based on the AraC regulatory protein. Although useful as a tool to screen for enhanced TAL biosynthesis, this variant shows elevated background (leaky) expression, poor sensitivity and relaxed inducer specificity, including responsiveness to orsellinic acid (OA). More sensitive biosensors specific to either TAL or OA can aid in the study and engineering of polyketide synthases that produce these and similar compounds. In this work, we employed a TetA-based dual-selection to isolate new TAL-responsive AraC variants showing reduced background expression and improved TAL sensitivity. To improve TAL specificity, OA was included as a ‘decoy’ ligand during negative selection, resulting in the isolation of a TAL biosensor that is inhibited by OA. Finally, to engineer OA-specific AraC variants, the iterative protein redesign and optimization computational framework was employed, followed by 2 rounds of directed evolution, resulting in a biosensor with 24-fold improved OA/TAL specificity, relative to AraC-TAL1.

Wang, Zhiqing↗

Characterization of a novel insect-specific flavivirus from Brazil: Potential for inhibition of infection of arthropod cells with medically important flaviviruses.

In the past decade, there has been an upsurge in the number of newly described insect-specific flaviviruses isolated pan-globally. We recently described the isolation of a novel flavivirus (tentatively designated ‘Nhumirim virus’; NHUV) that represents an example of a unique subset of apparently insect-specific viruses that phylogenetically affiliate with dual-host mosquito-borne flaviviruses despite appearing to be limited to replication in mosquito cells. We characterized the in vitro growth potential and 3' untranslated region (UTR) sequence homology with alternative flaviviruses, and evaluated the virus’s capacity to suppress replication of representative Culex spp.-vectored pathogenic flaviviruses in mosquito cells. Only mosquito cell lines were found to support NHUV replication, further reinforcing the insect-specific phenotype of this virus. Analysis of the sequence and predicted RNA secondary structures of the 3' UTR indicated NHUV to be most similar to viruses within the yellow fever serogroup and Japanese encephalitis serogroup, and viruses in the tick-borne flavivirus clade. NHUV was found to share the fewest conserved sequence elements when compared with traditional insect-specific flaviviruses. This suggests that, despite apparently being insect specific, this virus probably diverged from an ancestral mosquito-borne flavivirus. Co-infection experiments indicated that prior or concurrent infection of mosquito cells with NHUV resulted in a significant reduction in virus production of West Nile virus (WNV), St Louis encephalitis virus (SLEV) and Japanese encephalitis virus. As a result, the inhibitory effect was most effective against WNV and SLEV with over a 106-fold and 104-fold reduction in peak titres, respectively.

59 BASIC BIOLOGICAL SCIENCES↗

Tissue-specific SMARCA4 binding at active and repressed regulatory elements during embryogenesis

The SMARCA4 (also known as BRG1 in humans) chromatin remodeling factor is critical for establishing lineage-specific chromatin states during early mammalian development. However, the role of SMARCA4 in tissue-specific gene regulation during embryogenesis remains poorly defined. To investigate the genome-wide binding landscape of SMARCA4 in differentiating tissues, we engineered a Smarca4FLAG knock-in mouse line. Using ChIP-seq, we identified ~51,000 SMARCA4- associated regions across six embryonic mouse tissues (forebrain, hindbrain, neural tube, heart, limb, and face) at midgestation (E11.5). The majority of these regions was distal from promoters and showed dynamic occupancy, with most distal SMARCA4 sites (73%) confined to a single or limited subset of tissues. To further characterize these regions, we profiled active and repressive histone marks in the same tissues and examined the intersection of informative chromatin states and SMARCA4 binding. This revealed distinct classes of distal SMARCA4-associated elements characterized by activating and repressive chromatin signatures that were associated with tissue-specific up- or down-regulation of gene expression and relevant active/repressed biological pathways. We further demonstrate the predicted active regulatory properties of SMARCA4- associated elements by retrospective analysis of tissue-specific enhancers and direct testing of SMARCA4-bound regions in transgenic mouse assays. Our results indicate a dual active/repressive function of SMARCA4 at distal regulatory sequences in vivo and support its role in tissue-specific gene regulation during embryonic development.

59 BASIC BIOLOGICAL SCIENCES↗

Structural insights into the specific anti-HIV property of actinohivin: structure of its complex with the α(1–2)mannobiose moiety of gp120

X-ray analysis of anti-HIV actinohivin in complex with the target α(1-2)mannobiose moiety of high-mannose type glycans attached to HIV-1 gp120 reveals that the three rotamers generated with 120 rotations around the molecular pseudo-rotation axis are packed randomly in the unit cell according to the P2{sub 1}2{sub 1}2{sub 1} symmetry to exhibit an apparent space group P2{sub 1}3 as the statistical structure. However, the high-resolution X-ray structure shows the detailed interaction geometry for specific binding. Actinohivin (AH) is an actinomycete lectin with a potent specific anti-HIV activity. In order to clarify the structural evidence for its specific binding to the α(1–2)mannobiose (MB) moiety of the D1 chains of high-mannose-type glycans (HMTGs) attached to HIV-1 gp120, the crystal structure of AH in complex with MB has been determined. The AH molecule is composed of three identical structural modules, each of which has a pocket in which an MB molecule is bound adopting a bracket-shaped conformation. This conformation is stabilized through two weak C—H⋯O hydrogen bonds facilitated by the α(1–2) linkage. The binding features in the three pockets are quite similar to each other, in accordance with the molecular pseudo-threefold symmetry generated from the three tandem repeats in the amino-acid sequence. The shape of the pocket can accept two neighbouring hydroxyl groups of the O{sup 3} and O{sup 4} atoms of the equatorial configuration of the second mannose residue. To recognize these atoms through hydrogen bonds, an Asp residue is located at the bottom of each pocket. Tyr and Leu residues seem to block the movement of the MB molecules. Furthermore, the O{sup 1} atom of the axial configuration of the second mannose residue protrudes from each pocket into an open space surrounded by the conserved hydrophobic residues, suggesting an additional binding site for the third mannose residue of the branched D1 chain of HMTGs. These structural features provide strong evidence indicating that AH is only highly specific for MB and would facilitate the highly specific affinity of AH for any glycoprotein carrying many HMTGs, such as HIV-1 gp120.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of human nucleosome containing the testis-specific histone variant TSH2B

The crystal structure of human nucleosome containing the testis-specific TSH2B variant has been determined. The TSH2B Ser85 residue does not interact with H4 in the nucleosome, and induces a local structural difference between TSH2B and H2B in nucleosomes. The human histone H2B variant TSH2B is highly expressed in testis and may function in the chromatin transition during spermatogenesis. In the present study, the crystal structure of the human testis-specific nucleosome containing TSH2B was determined at 2.8 Å resolution. A local structural difference between TSH2B and canonical H2B in nucleosomes was detected around the TSH2B-specific amino-acid residue Ser85. The TSH2B Ser85 residue does not interact with H4 in the nucleosome, but in the canonical nucleosome the H2B Asn84 residue (corresponding to the TSH2B Ser85 residue) forms water-mediated hydrogen bonds with the H4 Arg78 residue. In contrast, the other TSH2B-specific amino-acid residues did not induce any significant local structural changes in the TSH2B nucleosome. These findings may provide important information for understanding how testis-specific histone variants form nucleosomes during spermatogenesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Challenges and Solutions of Meeting the Assembly Specifications for the 4.5 m Long MQXFA Magnets for the Hi-Luminosity LHC

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) has, in the recent years, developed assembly specifications for the 4.5 m long MQXFA magnets, which are 150 mm aperture high-field Nb 3 Sn low-β quadrupole magnets that are being built for the CERN Hi-Luminosity LHC (HL-LHC) upgrade. While the specifications were based on lessons learned from the LHC Accelerator Research Program (LARP) effort and the MQXFS and MQXFA prototype magnets, the experience gained from having both MQXFA07 and MQXFA08 magnets not meeting performance specifications during cold testing actually catalyzed a better understanding of the impact of the target assembly specifications and a subsequent refinement of the same. This paper summarizes a body of assembly data from the Pre-Series (MQXFA03-MQXFA07) and Series magnets (MQXFA08-MQXFA11) that have been built to date, and discusses the processes employed to successfully face the challenge of ensuring that the assembly specifications are met for the duration of the project.

43 PARTICLE ACCELERATORS↗

The three cellulose synthase isoforms for secondary cell wall make specific contributions to microfibril synthesis

Cellulose is synthesized at the plasma membrane by the cellulose synthase complex, a structure that contains three distinct isoforms of the catalytic subunit, cellulose synthase A (CESA). The division into three subunits appears early in land plant evolution and is highly conserved, particularly for the secondary cell wall. However, what if any unique roles each isoform plays in the complex remain unclear. Here, we assessed the contributions of specific isoforms to microfibril synthesis. First, we expressed CESA isoforms of the primary cell wall or the moss Physcomitrium patens in Arabidopsis thaliana backgrounds missing a secondary cell wall CESA. While the primary cell wall isoforms rescued the cesa knockout phenotype with partial isoform specificity, those from the moss rescued with fewer restrictions. Then, we recreated various CESA missense mutations in all three of the secondary cell wall isoforms; while results are consistent with isoform specificity, they are difficult to interpret further without molecular structures. Finally, we show that catalytically inactive CESA isoforms restore growth and cellulose content in the corresponding knockout in an isoform-specific manner; along with partial rescue of the growth and cellulose content of the inflorescence stem, the replacement lines have fiber cells with partially disorganized microfibrils and secondary cell wall cellulose with narrow crystal width. Generally, effects were more pronounced in lines where CESA8 was inactivated compared with inactivating CESA4 or 7, which tended to have similar phenotypes to each other. Here, we account for these results with a model for cellulose synthase structure with the isoforms assigned specific localization within the cellulose synthase complex.

59 BASIC BIOLOGICAL SCIENCES↗

Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: Machine-specific, plan-class, and clinical fields

Purpose: Recently, an international working group on nonstandard fields presented a new formalism for ionization chamber reference dosimetry of small and nonstandard fields [Alfonso et al., Med. Phys. 35, 5179-5186 (2008)] which has been adopted by AAPM TG-148. This work presents an experimental determination of the correction factors for reference dosimetry with an Exradin A1SL thimble ionization chamber in a TomoTherapy unit, focusing on: (i) machine-specific reference field, (ii) plan-class-specific reference field, and (iii) two clinical treatments. Methods: Ionization chamber measurements were performed in the TomoTherapy unit for intermediate (machine-specific and plan-class-specific) calibration fields, based on the reference conditions defined by AAPM TG-148, and two clinical treatments (lung and head-and-neck). Alanine reference dosimetry was employed to determine absorbed dose to water at the point of interest for the fields under investigation. The corresponding chamber correction factors were calculated from alanine to ionization chamber measurements ratios. Results: Two different methods of determining the beam quality correction factor k{sub Q,Q{sub 0}} for the A1SL ionization chamber in this TomoTherapy unit, where reference conditions for conventional beam quality determination cannot be met, result in consistent values. The observed values of overall correction factors obtained for intermediate and clinical fields are consistently around 0.98 with a typical expanded relative uncertainty of 2% (k = 2), which when considered make such correction factors compatible with unity. However, all of them are systematically lower than unity, which is shown to be significant when a hypothesis test assuming a t-student distribution is performed (p=1.8x10{sup -2}). Correction factors k{sub Q{sub c{sub l{sub i{sub n,Q{sub p{sub c{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub p}{sub c}{sub s}{sub r}}}}}}}}}} and k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, which are needed for the computation of field factors for relative dosimetry of clinical beams, have been found to be very close to unity for two clinical treatments. Conclusions: The results indicate that the helical field deliveries in this study (including two clinical fields) do not introduce changes on the ion chamber correction factors for dosimetry. For those two specific clinical cases, ratios of chamber readings accurately represent field output factors. The values observed here for intermediate calibration fields are in agreement with previously published data based on alanine dosimetry but differ from values recently reported obtained via radiochromic dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction factors for ionization chamber dosimetry in CyberKnife: Machine-specific, plan-class, and clinical fields

Purpose: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjaell, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, 'A new formalism for reference dosimetry of small and nonstandard fields,' Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. Methods: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. Results: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. Conclusions: The differences found between overall correction factors associated with the proposed intermediate calibration fields and the clinical fields under investigation show that depending on the clinical field and the detector used, either a machine-specific reference field or a plan-class specific reference field is more representative for the clinical field. Given the experimental and numerical uncertainties and the small number of clinical fields considered in this study the significance of these observations is limited and it remains unclear for the CyberKnife if there would be a significant gain in using a pcsr field rather than a msr field as reference field for relative dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-CAMPUS-T-04: Statistical Process Control for Patient-Specific QA in Proton Beams

Purpose: To evaluate and improve the reliability of proton QA process, to provide an optimal customized level using the statistical process control (SPC) methodology. The aim is then to suggest the suitable guidelines for patient-specific QA process. Methods: We investigated the constancy of the dose output and range to see whether it was within the tolerance level of daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to suggest the suitable guidelines for patient-specific QA in proton beam by using process capability indices. In this study, patient QA plans were classified into 6 treatment sites: head and neck (41 cases), spinal cord (29 cases), lung (28 cases), liver (30 cases), pancreas (26 cases), and prostate (24 cases). Results: The deviations for the dose output and range of daily QA process were ±0.84% and ±019%, respectively. Our results show that the patient-specific range measurements are capable at a specification limit of ±2% in all treatment sites except spinal cord cases. In spinal cord cases, comparison of process capability indices (Cp, Cpm, Cpk ≥1, but Cpmk ≤1) indicated that the process is capable, but not centered, the process mean deviates from its target value. The UCL (upper control limit), CL (center line) and LCL (lower control limit) for spinal cord cases were 1.37%, −0.27% and −1.89%, respectively. On the other hands, the range differences in prostate cases were good agreement between calculated and measured values. The UCL, CL and LCL for prostate cases were 0.57%, −0.11% and −0.78%, respectively. Conclusion: SPC methodology has potential as a useful tool to customize an optimal tolerance levels and to suggest the suitable guidelines for patient-specific QA in clinical proton beam.

60 APPLIED LIFE SCIENCES↗

SU-C-304-07: Are Small Field Detector Correction Factors Strongly Dependent On Machine-Specific Characteristics?

Purpose: The current small field dosimetry formalism utilizes quality correction factors to compensate for the difference in detector response relative to dose deposited in water. The correction factors are defined on a machine-specific basis for each beam quality and detector combination. Some research has suggested that the correction factors may only be weakly dependent on machine-to-machine variations, allowing for determinations of class-specific correction factors for various accelerator models. This research examines the differences in small field correction factors for three detectors across two Varian Truebeam accelerators to determine the correction factor dependence on machine-specific characteristics. Methods: Output factors were measured on two Varian Truebeam accelerators for equivalently tuned 6 MV and 6 FFF beams. Measurements were obtained using a commercial plastic scintillation detector (PSD), two ion chambers, and a diode detector. Measurements were made at a depth of 10 cm with an SSD of 100 cm for jaw-defined field sizes ranging from 3×3 cm{sup 2} to 0.6×0.6 cm{sup 2}, normalized to values at 5×5cm{sup 2}. Correction factors for each field on each machine were calculated as the ratio of the detector response to the PSD response. Percent change of correction factors for the chambers are presented relative to the primary machine. Results: The Exradin A26 demonstrates a difference of 9% for 6×6mm{sup 2} fields in both the 6FFF and 6MV beams. The A16 chamber demonstrates a 5%, and 3% difference in 6FFF and 6MV fields at the same field size respectively. The Edge diode exhibits less than 1.5% difference across both evaluated energies. Field sizes larger than 1.4×1.4cm2 demonstrated less than 1% difference for all detectors. Conclusion: Preliminary results suggest that class-specific correction may not be appropriate for micro-ionization chamber. For diode systems, the correction factor was substantially similar and may be useful for class-specific reference conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-JeP2-10: On the Need for a Dynamic Model for Patient-Specific Distortion Corrections for MR-Only Pelvis Treatment Planning

Purpose: Patient-specific distortions, particularly near tissue/air interfaces, require assessment and possible corrections for MRI-only radiation treatment planning (RTP). However, patients are dynamic due to changes in physiological status and motion during imaging sessions. This work investigated the need for dynamic patient-specific distortion corrections to support pelvis MR-only RTP. Methods: The pelvises of healthy volunteers were imaged at 1.0T, 1.5T, and 3.0T. Patient-specific distortion field maps were generated using a dual-echo gradient-recalled echo (GRE) sequence with B0 field maps obtained from the phase difference between the two echoes acquired at two timepoints: empty and full bladders. To quantify changes arising from respiratory state, end-inhalation and end-expiration data were acquired. Distortion map differences were computed between the empty/full bladder and inhalation/expiration to characterize local changes. The normalized frequency distortion distributions in T2-weighted TSE images were characterized, particularly for simulated prostate planning target volumes (PTVs). Results: Changes in rectal and bowel air location were observed, likely due to changes in bladder filling. Within the PTVs, displacement differences (mean ± stdev, range) were −0.02 ± 0.02 mm (−0.13 to 0.07 mm) for 1.0T, −0.1 ± 0.2 mm (−0.92 to 0.74 mm) for 1.5T, and −0.20 ± 0.03 mm (−0.61 to 0.38 mm) for 3.0T. Local changes of ∼1 mm at the prostate-rectal interface were observed for an extreme case at 1.5T. For end-inhale and end-exhale scans at 3.0T, 99% of the voxels had Δx differences within ±0.25mm, thus the displacement differences due to respiratory state appear negligible in the pelvis. Conclusion: Our work suggests that transient bowel/rectal gas due to bladder filling may yield non-negligible patient-specific distortion differences near the prostate/rectal interface, whereas respiration had minimal effect. A temporal patient model for patient-specific distortion corrections may be advantageous for MR-only RTP, although further investigations in larger cohorts are needed to fully characterize distortion magnitude. The submitting institution has research agreements with Philips Healthcare. Research sponsored by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

A multi-specific, multi-affinity antibody platform neutralizes sarbecoviruses and confers protection against SARS-CoV-2 in vivo

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19), has been responsible for a global pandemic. Monoclonal antibodies (mAbs) have been used as antiviral therapeutics; however, these therapeutics have been limited in efficacy by viral sequence variability in emerging variants of concern (VOCs) and in deployment by the need for high doses. In this study, we leveraged the multi-specific, multi-affinity antibody (Multabody, MB) platform, derived from the human apoferritin protomer, to enable the multimerization of antibody fragments. MBs were shown to be highly potent, neutralizing SARS-CoV-2 at lower concentrations than their corresponding mAb counterparts. In mice infected with SARS-CoV-2, a tri-specific MB targeting three regions within the SARS-CoV-2 receptor binding domain was protective at a 30-fold lower dose than a cocktail of the corresponding mAbs. Furthermore, we showed in vitro that mono-specific MBs potently neutralize SARS-CoV-2 VOCs by leveraging augmented avidity, even when corresponding mAbs lose their ability to neutralize potently, and that tri-specific MBs expanded the neutralization breadth beyond SARS-CoV-2 to other sarbecoviruses. Our work demonstrates how avidity and multi-specificity combined can be leveraged to confer protection and resilience against viral diversity that exceeds that of traditional monoclonal antibody therapies.

60 APPLIED LIFE SCIENCES↗

Chimeric Fatty Acyl-Acyl Carrier Protein Thioesterases Provide Mechanistic Insight into Enzyme Specificity and Expression

Medium-chain fatty acids are commodity chemicals. Increasing and modifying the activity of thioesterases (TEs) on medium-chain fatty acyl-acyl carrier protein (acyl-ACP) esters may enable a high-yield microbial production of these molecules. The plant Cuphea palustris harbors two distinct TEs: C. palustris FatB1 ( Cp FatB1) (C 8 specificity, lower activity) and Cp FatB2 (C 14 specificity, higher activity) with 78% sequence identity. We combined structural features from these two enzymes to create several chimeric TEs, some of which showed nonnatural fatty acid production as measured by an enzymatic assay and gas chromatography-mass spectrometry (GC-MS). Substantially, chimera 4 exhibited an increased C 8 fatty acid production in correlation with improved microbial expression. This chimera led us to identify Cp FatB2-specific amino acids between positions 219 and 272 that lead to higher protein levels. Chimera 7 produced a broad range of fatty acids and appeared to combine a fatty acid binding pocket with long-chain specificity and an ACP interaction site that may activate fatty acid extrusion. Using homology modeling and in silico docking with ACP, we identified a “positive patch” within amino acids 162 to 218, which may direct the ACP interaction and regulate access to short-chain fatty acids. On the basis of this modeling, we transplanted putative ACP interaction sequences from Cp FatB1 into Cp FatB2 and created a chimeric thioesterase that produced medium-chain as well as long-chain fatty acids. Hence, the engineering of chimeric enzymes and characterizing their microbial activity and chain-length specificity suggested mechanistic insights into TE functions and also generated thioesterases with potentially useful properties. These observations may inform a rational engineering of TEs to allow alkyl chain length control. IMPORTANCE: Medium-chain fatty acids are important commodity chemicals. These molecules are used as plastic precursors and in shampoos and other detergents and could be used as biofuel precursors if production economics were favorable. Hydrocarbon-based liquid fuels must be optimized to have a desired boiling point, low freezing point, low viscosity, and other physical characteristics. Furthermore, the solubility and harshness of detergents and the flexibility of plastic polymers can be modulated. The length and distribution of the carbon chains in the hydrophobic tails determine these properties. The biological synthesis of cell membranes and fatty acids produces chains of primarily 16 to 18 carbons, which give rise to current biofuels. The ultimate goal of the work presented here is to engineer metabolic pathways to produce designer molecules with the correct number of carbons in a chain, so that such molecules could be used directly as specialty commodity chemicals or as fuels after minimal processing.

59 BASIC BIOLOGICAL SCIENCES↗

Familial Associations of Prevalence and Cause-Specific Mortality for Thoracic Aortic Disease and Bicuspid Aortic Valve in a Large-Population Database

Thoracic aortic disease and bicuspid aortic valve (BAV) likely have a heritable component, but large population-based studies are lacking. This study characterizes familial associations of thoracic aortic disease and BAV, as well as cardiovascular and aortic-specific mortality, among relatives of these individuals in a large-population database. In this observational case-control study of the Utah Population Database, we identified probands with a diagnosis of BAV, thoracic aortic aneurysm, or thoracic aortic dissection. Age- and sex-matched controls (10:1 ratio) were identified for each proband. First-degree relatives, second-degree relatives, and first cousins of probands and controls were identified through linked genealogical information. Cox proportional hazard models were used to quantify the familial associations for each diagnosis. We used a competing-risk model to determine the risk of cardiovascular-specific and aortic-specific mortality for relatives of probands. The study population included 3,812,588 unique individuals. Familial hazard risk of a concordant diagnosis was elevated in the following populations compared with controls: first-degree relatives of patients with BAV (hazard ratio [HR], 6.88 [95% CI, 5.62–8.43]); first-degree relatives of patients with thoracic aortic aneurysm (HR, 5.09 [95% CI, 3.80–6.82]); and first-degree relatives of patients with thoracic aortic dissection (HR, 4.15 [95% CI, 3.25–5.31]). In addition, the risk of aortic dissection was higher in first-degree relatives of patients with BAV (HR, 3.63 [95% CI, 2.68–4.91]) and in first-degree relatives of patients with thoracic aneurysm (HR, 3.89 [95% CI, 2.93–5.18]) compared with controls. Dissection risk was highest in first-degree relatives of patients who carried a diagnosis of both BAV and aneurysm (HR, 6.13 [95% CI, 2.82–13.33]). First-degree relatives of patients with BAV, thoracic aneurysm, or aortic dissection had a higher risk of aortic-specific mortality (HR, 2.83 [95% CI, 2.44–3.29]) compared with controls. Our results indicate that BAV and thoracic aortic disease carry a significant familial association for concordant disease and aortic dissection. The pattern of familiality is consistent with a genetic cause of disease. Furthermore, we observed higher risk of aortic-specific mortality in relatives of individuals with these diagnoses. In conclusion, this study provides supportive evidence for screening in relatives of patients with BAV, thoracic aneurysm, or dissection.

60 APPLIED LIFE SCIENCES↗