Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Siloxane Deposition on the Ni-YSZ Solid Oxide Fuel Cell Anode Exposed to Bio-Syngas

Siloxane, a common contaminant present in biogas, is known for adverse effects on cogeneration prime movers. In this study, the siloxane deposition products and mechanism in the solid oxide fuel cell nickel-yttria stabilized zirconia (Ni-YSZ) anode are investigated analytically and experimentally. An SOFC with Ni-YSZ anode and pure Ni/YSZ pellets were exposed to a simulated biogas-reformate fuel with octamethylcyclotetrasiloxane (D4) contamination at 750 °C. The electrochemical characterization results show that the SOFCs performance degradation caused by D4 contamination is irreversible. Morphology and XRD results illustrate that silicon and carbon deposition can both be detected in the anode and pellets. Graphite, SiC and SiO2 are all possible products based on the results of XRD test. Here, according to the formation of graphite and SiC, the new mechanism suggests that carbon is also an essential factor in siloxane contamination of Ni-YSZ anodes besides silicon, which can be explained by the catalytic and electrochemical analysis.

25 ENERGY STORAGE↗

Succinonitrile-Lithium Salt Complexes as Solid Catholytes for LLZO-Based Solid-State Batteries

The thermal and electrochemical properties of several succinonitrile (SN)-based organic ionic plastic crystals (OIPCs) containing lithium bis(trifluoromethanesulfonyl)imide (LiTFSI), lithium bis(oxalate) borate (LiBOB) or mixtures of the two salts, were investigated with the goal of determining which is most promising for use as a catholyte in solid-state lithium batteries. The best combination of properties for this use was found for the mixture containing 3 mol% LiTFSI and 2 mol% LiBOB in SN. Based on these observations, several solid-state cells containing Al-substituted Li 7 La 3 Zr 2 O 12 separators with composite cathodes consisting of LiNi 0.33 Mn 0.33 Co 0.33 O 2 (NMC111), carbon black, and the succinonitrile-salt mixtures were assembled and cycled at room temperature, without exogenous pressure, using a simple design.

25 ENERGY STORAGE↗

A Diffuse-Interface Model for Predicting the Evolution of Metallic Negative Electrodes and Interfacial Voids in Solid-State Batteries with Homogeneous and Polycrystalline Solid Electrolyte Separators

Here, this paper presents a novel diffuse-interface electrochemical model that simultaneously simulates the evolution of the metallic negative electrode and interfacial voids during the stripping and plating processes in solid-state batteries. The utility and validity of this model are demonstrated for the first time on a cell with a sodium (Na) negative electrode and a Na-β″-alumina ceramic solid electrolyte (SE) separator. Three examples are simulated. First, stripping and plating with a perfect electrode/electrolyte interface; second, stripping and plating with a single interfacial void at the electrode/electrolyte interface; third, stripping with multiple interfacial voids. Both homogeneous and polycrystalline SEs with low and high-conductivity grain boundaries (GBs) are considered for all three examples. Heterogeneous GB conductivity marginally impacts the thickness of the Na electrode in cases with a perfect electrode/electrolyte interface. Moreover, it results in local changes to void growth due to the interactions between the void edge and the GBs. The void growth rate is a linear function of the flux of Na atoms at the void edge, which in turn depends on the applied current density. We also show that the void coalescence rate increases with applied current density and can be marginally influenced by GB conductivity.

batteries↗

Long-wavelength-infrared laser filamentation in solids in the near-single-cycle regime

We experimentally demonstrate long-wavelength-infrared (LWIR) femtosecond filamentation in solids. Systematic investigations of supercontinuum (SC) generation and self-compression of the LWIR pulses assisted by laser filamentation are performed in bulk KrS-5 and ZnSe, pumped by ∼ <#comment/> 145 f s , 9 µm, 10 µJ pulses from an optical parametric chirped-pulse amplifier operating at 10 kHz of repetition rate. Multi-octave SC spectra are demonstrated in both materials. While forming stable single filament, 1.5 cycle LWIR pulses with 4.5 µJ output pulse energy are produced via soliton-like self-compression in a 5 mm thick KrS-5. The experimental results quantitatively agree well with the numerical simulation based on the unidirectional pulse propagation equation. This work shows the experimental feasibility of high-energy, near-single-cycle LWIR light bullet generation in solids.

Qu, Shizhen↗

Solid Phase Characterization of Tank 241-C-108 Residual Waste Solids Samples

This report presents the results for solid phase characterization (SPC) of solid samples removed from tank 241-C-108 (C-108) on August 12-13,2012, using the off-riser sampler. Samples were received at the 222-S Laboratory on August 13 and were described and photographed. The SPC analyses that were performed include scanning electron microscopy (SEM) using the ASPEX(R)l scanning electron microscope, X-ray diffraction (XRD) using the Rigaku(R) 2 MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon(R) 3 Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information. Gary A. Cooke conducted the SEM analysis, John A. Pestovich performed the XRD analysis, and Dr. Heinz J. Huber performed the PLM examination. The results of these analyses are presented here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impurity Diffusion Coefficients of Al and Zn in Mg Determined from Solid-to-Solid Diffusion Couples

Increasing use and development of lightweight Mgalloys have led to the desire for more fundamental research in and understanding of Mg-based systems. As property enhancing components, Al and Zn are two of the most important and common alloying elements for Mg-alloys. We have investigated the concentration dependent interdiffusion of Al and Zn in Mg using diffusion couples of pure polycrystalline Mg mated to Mg solid solutions containing either <9 at.% Al or <3 at.% Zn. Concentration profiles were determined by electron micro-probe microanalysis of the diffusion zone. The interdiffusion coefficients were determined by the classical Boltzmann-Matano method within the Mg solid solution. As the concentration of Al or Zn approaches the dilute ends, we employ an analytical approach based on the Hall method to estimate the impurity diffusion coefficients. Results of Al and Zn impurity diffusion in Mg are reported and compared to published impurity diffusion coefficients typically determined by thin film techniques.

Aluminum↗

IC W13_fephases Highlight:Solid-Solid Phase Boundary in Fe

Temperature of the fcc-bcc (face-centered cubic – body-centered cubic) solid-solid phase transition in Fe calculated as Teq = Tinst ΔEfcc-bcc/ΔEbcc-m. (where m. stands for martensitic mixture that bcc-Fe converts into at Tinst) maps out a curve which is consistent with the line of the fast recrystallization threshold observed in the recent experiments on Fe at ESRF.

36 MATERIALS SCIENCE↗

The Effect of Operational Temperature on the Performance and Durability of Solid Oxide Fuel Cells and Solid Oxide Electrolysis Cells

Solid oxide fuel cells (SOFC) and solid oxide electrolysis cells (SOEC) have received great interest due to their highly effective reversibility as power generation and H2 production system without releasing any greenhouse gases into environment. The LSCF electrode exhibits a higher structural and performance stability under both SOFC and SOEC operation due to its mixed ionic and electronic conductivity, and there is no immediate delamination taking place during the initial several hundred hours operation. However, the LSCF based air electrode still presents significant performance degradation (with the increased resistance) over the prolonged operation, such as over 1000 hours of operation under SOFC and SOEC. The influence factors for the cell’s performance and stability need to be optimized to improve the power generation for SOFC and H2 production for SOEC. The effects of operational temperature on the performance and durability for both SOFC and SOEC are electrochemical operation dependent. The performance and performance durability for the first 1500h were currently studied under optimized operational temperature for reversible SOFC/SOEC.

Fan, Yueying [NETL Site Support Contractor, Nation↗

NMR Measurements for Solid Polarized Targets at Jefferson Lab

Jefferson Lab's solid polarized targets rely on Nuclear Magnetic Resonance techniques to measure the enhanced polarization provided under Dynamic Nuclear Polarization. Upcoming polarized target experiments in JLab's Hall B present challenging conditions which would benefit from improvements to traditional NMR techniques. For decades, JLab has utilized Liverpool Q Meters for NMR measurements, but these are aging and no longer produced. The polarized target group at Bochum has successfully produced replacement Q Meters with modern components, and we are following their example, exploring new designs for both an analog and a digital Q Meter system. Unlike recent experiments in Halls A and C, the new Hall B target will require external NMR coils, resulting in a weaker signal. In addition, two separate target cells will be utilized, each held at different magnetic fields, allowing them to be polarized in opposing directions, but complicating the NMR measurement. We present the challenges presented by the new Hall B target, lay out plans for improvements to our NMR system, and show results of initial tests of our designs.

Maxwell, James↗

Solid-solid phase transition measurements in iron

Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the Los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes. Direct density jumps were measured which corresponded to calculations to within 1% using a Wondy mUlti-phase equation of state model. In addition, shock velocities were measured using an edge fitting technique and followed that edge movement from radiograph to radiograph, where radiographs are separated in time by 500 ns. Preliminary measurements give a shock velocity (P1 wave) of 5.251 km/s. The projectile velocity was 0.725 km/s which translate to a peak stress of 17.5 GPa. Assuming the P1 wave is instantaneous, we are able to calibrate the chromatic, motion, object and camera blur by measuring the width of the P1 wave. This approximation works in this case since each of the two density jumps are small compared to the density of the object. Subtracting the measured width of the P1 wave in quadrature from the width of the P2 wave gives a preliminary measurement of the transition length of 265 {mu}m. Therefore, a preliminary measured phase transition relaxation time {tau} = transition length/u{sub s} = 265 {mu}m/5.251 km/s = 50 ns. Both Boettger and Jensen conclude that the transition rate and likely the transition mechanisms depend on the impact stress and the sample thickness. Since Proton Radiography can measure directly the transition length as well as the shock velocity, a transition time can be directly calculated. With higher higher energy protons we have better resolution of the measured width and edge locations. This will allow a more precise measurement of phase transition relaxation time. We propose to perform a series of experiments to measure the phase transition relaxation time, {tau}, as a function of drive and sample size.

36 MATERIALS SCIENCE↗

Semi-Solid Flowable Battery Electrodes: Semi-Solid Flow Cells for Automotive and Grid-Level Energy Storage

BEEST Project: Scientists at 24M are crossing a Li-Ion battery with a fuel cell to develop a semi-solid flow battery. This system relies on some of the same basic chemistry as a standard Li-Ion battery, but in a flow battery the energy storage material is held in external tanks, so storage capacity is not limited by the size of the battery itself. The design makes it easier to add storage capacity by simply increasing the size of the tanks and adding more paste. In addition, 24M's design also is able to extract more energy from the semi-solid paste than conventional Li-Ion batteries. This creates a cost-effective, energy-dense battery that can improve the driving range of EVs or be used to store energy on the electric grid.

30 DIRECT ENERGY CONVERSION↗

Kinetics of solid-solid phase transitions in metals using proton radiography (u)

When a compressed material changes phase it doesn't do so instantly. Instead it transitions through a mixed phase as it transforms to the end state phase for a given pressure, volume and temperature. Common phase diagrams show the phase boundaries as sharp lines when compression has been slowly applied and held for an infinite amount of time. When the compression is applied with high strain rate, however, the phase boundaries are no longer crisp as the kinetic effects of the crystal reorientation delay the transitions, resulting in regions of mixed phase. This opens up the possibility that some degree of metastability exists for such transition in dynamic compression. The compression path can go past the equilibrium phase boundary and the transition happen from a metastable state because of the very short timescale of the compression process. Molecular dynamics (MD) simulations recently have been used to examine shock-induced phase transitions in single crystal materials illustrating an orientation dependence of the transition stress, mechanisms, kinetics, and Hugoniot response. For example, the [100] orientation of iron had a simulated transition stress higher than the experimentally determined polycrystalline value of 13 GPa by 2 GPa. Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the Los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13 GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter sample of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes.

36 MATERIALS SCIENCE↗

Kinetics of Solid-Solid Phase Transition in Iron (u)

Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes. Direct density jumps were measured which corresponded to calculations to within 1% using a Wondy multi-phase equation of state model. In addition, shock velocities were measured using an edge fitting technique and followed that edge movement from radiograph to radiograph, where rad iographs are separated in time by 500 ns. Preliminary measurements give a shock velocity (P1 wave) of 5.251 km/s. The projectile velocity was 0.725 km/s which translate to a peak stress of 17.5 GPa. Assuming the P1 wave is instantaneous, we are able to calibrate the chromatic, motion, object and camera blur by measuring the width of the P1 wave. This approximation works in this case since each of the two density jumps are small compared to the density of the object. Subtracting the measured width of the P1 wave in quadrature from the width of the P2 wave gives a preliminary measurement of the transition length of 265 {micro}m. Therefore, a preliminary measured phase transition relaxation time {tau} = transition length/u{sub s} = 265 {micro}m/5.251 km/s = 50 ns. Both Boettger1 & Jensen2 conclude that the transition rate and likely the transition mechanisms depend on the impact stress and the sample thickness. Since Proton Radiography can measure directly the transition length as well as the shock velocity, a transition time can be directly calculated. We propose to perform a series of experiments to measure the phase transition relaxation time, 1, as a function of drive, sample size and crystal orientation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solid electrolyte material and solid-state battery made therewith

A solid electrolyte material comprises Li, T, X and A wherein T is at least one of P, As, Si, Ge, Al, and B; X is one or more halogens or N; A is one or more of S and Se. The solid electrolyte material has peaks at 17.8°±0.75° and 19.2°±0.75° in X-ray diffraction measurement with Cu-Kα(1,2)=1.5418 Å and may include glass ceramic and/or mixed crystalline phases.

Francisco, Brian E.↗

Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n'γ) reactions towards lower energies and the isotropic character of scattering of the secondary neutrons may lead to the observed limitation of the length of effective interaction, since a fraction of the secondary neutrons that propagate in the forward direction are not subject to further inelastic scattering because of their substantially lower energy. At these reduced energies, it is the capture cross-section (n, γ) that becomes predominant, resulting in lower detection efficiency. Based on these results, several types of detectors have been envisioned for application in detection systems for nuclear materials. The testing results for one such detector are presented in this work. We have studied the possibility of creation of a composite detector with scintillator granules placed inside a transparent polymer material. Because of the low transparency of such a dispersed scintillator, better light collection conditions are ensured by incorporation of a light guide between the scintillator layers. This guide is made of highly transparent polymer material. The use of a high-transparency hydrogen-containing polymer material for light guides not only ensures optimum conditions of light collection in the detector, but also allows certain deceleration of neutron radiation, increasing its interaction efficiency with the composite scintillation panels; accordingly, the detector signal is increased by 5-8%. When fast neutrons interact with the scintillator material, the resulting inelastic scattering gamma-quanta emerge, having different energies and different delay times with respect to the moment of the neutron interaction with the nucleus of the scintillator material (delay times ranging from 1x10{sup -9} to 1.3x10{sup -6} s). These internally generated gamma-quanta interact with the scintillator, and the resulting scintillation light is recorded by the photo-receiver. Since neutron sources are also strong sources of low-energy gamma-radiation, the use of dispersed ZnSe(Te) scintillator material provides high gamma-radiation detection efficiency in that energy range. This new type of gamma-neutron detector is based on a 'sandwich' structure using a ZnSe composite film and light guide with a fast neutron detection efficiency of about 6%. Its high detection efficiency of low-energy gamma-radiation allows a substantial increase (by an order of magnitude) in the efficiency of detection of neutron sources and transuranic materials by means of simultaneous detection of accompanying gamma-radiation. The design and fabrication technology of this detector allows the creation of gamma-neutron detectors characterized by high sensitivity at relatively low costs (as compared with analogs using oxide scintillators) for portable inspection systems. The sandwich structure can be comprised of any number of plates, with no limitations on thickness or area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid electrolyte material and solid-state battery made therewith

A solid electrolyte material comprises Li, T, X and A wherein T is at least one of P, As, Si, Ge, Al, and B; X is one or more halogens or N; A is one or more of S and Se. The solid electrolyte material has peaks at 17.8°±0.75° and 19.2°±0.75° in X-ray diffraction measurement with Cu-Kα(1,2)=1.5418 Å and may include glass ceramic and/or mixed crystalline phases.

Francisco, Brian E.↗