Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SU-E-T-211: Induced Release of Nanocarrier Encapsulated Chemotherapeutic Drugs Using Proton Radiotherapy Beams

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

60 APPLIED LIFE SCIENCES↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗

Dual Active Bridge based DC Transformer LabVIEW FPGA Control Code [SWR-16-25]

In the area of power electronics control, Field Programmable Gate Arrays (FPGAs) have the capability to outperform their Digital Signal Processor (DSP) counterparts due to the FPGA’s ability to implement true parallel processing and therefore facilitate higher switching frequencies, higher control bandwidth, and/or enhanced functionality. National Instruments (NI) has developed two platforms, Compact RIO (cRIO) and Single Board RIO (sbRIO), which combine a real-time processor with an FPGA. The FPGA can be programmed with a subset of the well-known LabVIEW graphical programming language. The candidate software implements complete control algorithms in LabVIEW FPGA for a DC Transformer (DCX) based on a dual active bridge (DAB). A DCX is an isolated bi-directional DC-DC converter designed to operate at unity conversion ratio, M, defined by where Vin is the primary-side DC bus voltage, Vout is the secondary-side DC bus voltage, and n is the turns ratio of the embedded high frequency transformer (HFX). The DCX based on a DAB incorporates two H-bridges, a resonant inductor, and an HFX to provide this functionality. The candidate software employs phase-shift modulation of the two H-bridges and a feedback loop to regulate the conversion ratio at unity. The software also includes alarm-handling capabilities as well as debugging and tuning tools. The software fits on the Xilinx Virtex V LX110 FPGA embedded in the NI cRIO-9118 FPGA chassis, and with a 40 MHz base clock, supports a modulation update rate of 40 MHz, and user-settable switching frequencies and synchronized control loop update rates of tens of kHz.

Source record↗

PNNLs Data Intensive Computing research battles Homeland Security threats

The Pacific Northwest National Laboratorys (PNNL's) approach to data intensive computing (DIC) is focused on three key research areas: hybrid hardware architecture, software architectures, and analytic algorithms. Advancements in these areas will help to address, and solve, DIC issues associated with capturing, managing, analyzing and understanding, in near real time, data at volumes and rates that push the frontiers of current technologies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

TEAM project review, year 1

This note summarizes our research activities within the TEAM project between October 2019 and November 2020, funded by the ASCR Advanced Research in Quantum Computing program. Three research efforts have begun during the review period. The first effort, resulting in the JuQBox software, implemented a novel algorithm for optimal control in closed quantum systems based on symplectic time integration and exact calculations of the gradient of the discretized objective function. In our second effort, resulting in a code called Quandary, we consider the optimal control problem for open quantum systems. Here the evolution of the quantum system is modeled by the Lindblad master equation. In this code, we are considering both the realization of quantum gates as well as the optimal reset problem in which a general mixed quantum state is driven towards its ground state. In our third research effort we have begun the development of computational software for what we call Lindblad learning, i.e. the process of characterizing the equations governing our quantum computing hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cabana: A Performance Portable Library for Particle-Based Simulations

Particle-based simulations are ubiquitous throughout many fields of computational science and engineering, spanning the atomistic level with molecular dynamics (MD), to mesoscale particle-in-cell (PIC) simulations for solid mechanics, device-scale modeling with PIC methods for plasma physics, and massive N-body cosmology simulations of galaxy structures, with many other methods in between (Hockney & Eastwood, 1989). While these methods use particles to represent significantly different entities with completely different physical models, many low-level details are shared including performant algorithms for short- and/or long-range particle interactions, multi-node particle communication patterns, and other data management tasks such as particle sorting and neighbor list construction. Cabana is a performance portable library for particle-based simulations, developed as part of the Co-Design Center for Particle Applications (CoPA) within the Exascale Computing Project (ECP) (Alexander et al., 2020). The CoPA project and its full development scope, including ECP partner applications, algorithm development, and similar software libraries for quantum MD, is described in (Mniszewski et al., 2021). Cabana uses the Kokkos library for on-node parallelism (Edwards et al., 2014; Trott et al., 2022), enabling simulation on multi-core CPU and GPU architectures, and MPI for GPU-aware, multi-node communication. Cabana provides particle simulation capabilities on almost all current Kokkos backends, including serial execution, OpenMP (including OpenMP-Target for GPUs), CUDA (NVIDIA GPUs), HIP (AMD GPUs), and SYCL (Intel GPUs), providing a clear path for the coming generation of accelerator-based exascale hardware. Cabana builds on Kokkos by providing new particle data structures and particle algorithms resulting in a similar execution policy-based, node-level programming model that is intended to be used in addition to the core Kokkos library within an application. Cabana is designed as an application and physics agnostic, but particle-specific toolkit which can either be used to generate a new application, or to be used as needed in existing applications at various levels of invasiveness including through interfaces that wrap user memory in existing data structures.

97 MATHEMATICS AND COMPUTING↗

In silico toxicology for the pharmaceutical sciences

The applied use of in silico technologies (a.k.a. computational toxicology, in silico toxicology, computer-assisted tox, e-tox, i-drug discovery, predictive ADME, etc.) for predicting preclinical toxicological endpoints, clinical adverse effects, and metabolism of pharmaceutical substances has become of high interest to the scientific community and the public. The increased accessibility of these technologies for scientists and recent regulations permitting their use for chemical risk assessment supports this notion. The scientific community is interested in the appropriate use of such technologies as a tool to enhance product development and safety of pharmaceuticals and other xenobiotics, while ensuring the reliability and accuracy of in silico approaches for the toxicological and pharmacological sciences. For pharmaceutical substances, this means active and impurity chemicals in the drug product may be screened using specialized software and databases designed to cover these substances through a chemical structure-based screening process and algorithm specific to a given software program. A major goal for use of these software programs is to enable industry scientists not only to enhance the discovery process but also to ensure the judicious use of in silico tools to support risk assessments of drug-induced toxicities and in safety evaluations. However, a great amount of applied research is still needed, and there are many limitations with these approaches which are described in this review. Currently, there is a wide range of endpoints available from predictive quantitative structure-activity relationship models driven by many different computational software programs and data sources, and this is only expected to grow. For example, there are models based on non-proprietary and/or proprietary information specific to assessing potential rodent carcinogenicity, in silico screens for ICH genetic toxicity assays, reproductive and developmental toxicity, theoretical prediction of human drug metabolism, mechanisms of action for pharmaceuticals, and newer models for predicting human adverse effects. How accurate are these approaches is both a statistical issue and challenge in toxicology. In this review, fundamental concepts and the current capabilities and limitations of this technology will be critically addressed.

60 APPLIED LIFE SCIENCES↗

In-Situ Assays Using a New Advanced Mathematical Algorithm - 12400

Current mathematical efficiency modeling software for in-situ counting, such as the commercially available In-Situ Object Calibration Software (ISOCS), typically allows the description of measurement geometries via a list of well-defined templates which describe regular objects, such as boxes, cylinder, or spheres. While for many situations, these regular objects are sufficient to describe the measurement conditions, there are occasions in which a more detailed model is desired. We have developed a new all-purpose geometry template that can extend the flexibility of current ISOCS templates. This new template still utilizes the same advanced mathematical algorithms as current templates, but allows the extension to a multitude of shapes and objects that can be placed at any location and even combined. In addition, detectors can be placed anywhere and aimed at any location within the measurement scene. Several applications of this algorithm to in-situ waste assay measurements, as well as, validations of this template using Monte Carlo calculations and experimental measurements are studied. Presented in this paper is a new template of the mathematical algorithms for evaluating efficiencies. This new template combines all the advantages of the ISOCS and it allows the use of very complex geometries, it also allows stacking of geometries on one another in the same measurement scene and it allows the detector to be placed anywhere in the measurement scene and pointing in any direction. We have shown that the template compares well with the previous ISOCS software within the limit of convergence of the code, and also compare well with the MCNPX and measured data within the joint uncertainties for the code and the data. The new template agrees with ISOCS to within 1.5% at all energies. It agrees with the MCNPX to within 10% at all energies and it agrees with most geometries within 5%. It finally agrees with measured data to within 10%. This mathematical algorithm can now be used for quickly and accurately evaluating efficiencies for wider range of gamma-ray spectroscopy applications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Graph Neural Network-based Tracking as a Service

Recent studies have shown promising results for track finding in dense environments using Graph Neural Network (GNN)-based algorithms. However, GNN-based track finding is computationally slow on CPUs, necessitating the use of coprocessors to accelerate the inference time. Additionally, the large input graph size demands a large device memory for efficient computation, a requirement not met by all computing facilities used for particle physics experiments, particularly those lacking advanced GPUs. Furthermore, deploying the GNN-based track-finding algorithm in a production environment requires the installation of all dependent software packages, exclusively utilized by this algorithm. These computing challenges must be addressed for the successful implementation of GNN-based track-finding algorithm into production settings. In response, we introduce a ``GNN-based tracking as a service'' approach, incorporating a custom backend within the NVIDIA Triton inference server to facilitate GNN-based tracking. This paper presents the performance of this approach using the Perlmutter supercomputer at NERSC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NeuroFEM

SAND2025-00525O NeuroFEM is a software tool that demonstrates a neuromorphic algorithm for solving finite element problems. It sets up a 2D finite element problem for the Poisson equation on a disk, constructs synaptic matrices, and simulates neural dynamics to solve the resulting sparse linear system. The software illustrates how the algorithm converges to the solution and plots the results, showcasing a neuromorphic counterpart to traditional methods like Conjugate Gradient or GMRES. This tool is designed to highlight the potential of neuromorphic algorithms for solving sparse linear systems, which are prevalent in various computational applications. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

A nested dissection approach to sparse matrix partitioning for parallel computations.

We consider how to distribute sparse matrices among processes to reduce communication costs in parallel sparse matrix computations, specifically, sparse matrix-vector multiplication. Our main contributions are: (i) an exact graph model for communication with general (two-dimensional) matrix distribution, and (ii) a recursive partitioning algorithm based on nested dissection (substructuring). We show that the communication volume is closely linked to vertex separators. We have implemented our algorithm using hypergraph partitioning software to enable a fair comparison with existing methods. We present numerical results for sparse matrices from several application areas, with up to 9 million nonzeros. The results show that our new approach is superior to traditional 1d partitioning and comparable to a current leading partitioning method, the finegrain hypergraph method, in terms of communication volume. Our nested dissection method has two advantages over the fine-grain method: it is faster to compute, and the resulting distribution requires fewer communication messages.

97 MATHEMATICS AND COMPUTING↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Impact of Void-finding Algorithms on Galaxy Classification

We explore how the definition of a void influences the conclusions drawn about the impact of the void environment on galactic properties using two void-finding algorithms in the Void Analysis Software Toolkit: Voronoi Voids (V 2 ), a Python implementation of ZOnes Bordering On Voidness (ZOBOV); and VoidFinder, an algorithm that grows and merges spherical void regions. Using the Sloan Digital Sky Survey Data Release 7, we find that galaxies found in VoidFinder voids tend to be bluer and fainter and to have higher (specific) star formation rates than galaxies in denser regions. Conversely, galaxies found in V 2 voids show less significant differences when compared to galaxies in denser regions, less consistent with the large-scale environmental effects on galaxy properties expected from both simulations and previous observations. These results align with previous simulation results that show V 2 -identified voids “leak” into the dense walls between voids because their boundaries extend up to the density maxima in the walls. As a result, when using ZOBOV-based void-finders, galaxies likely to be part of wall regions are instead classified as void galaxies, a misclassification that can be critical to our understanding of galaxy evolution.

cosmic web↗

TMVOC-MP: a parallel numerical simulator for Three-PhaseNon-isothermal Flows of Multicomponent Hydrocarbon Mixtures inporous/fractured media

TMVOC-MP is a massively parallel version of the TMVOC code (Pruess and Battistelli, 2002), a numerical simulator for three-phase non-isothermal flow of water, gas, and a multicomponent mixture of volatile organic chemicals (VOCs) in multidimensional heterogeneous porous/fractured media. TMVOC-MP was developed by introducing massively parallel computing techniques into TMVOC. It retains the physical process model of TMVOC, designed for applications to contamination problems that involve hydrocarbon fuels or organic solvents in saturated and unsaturated zones. TMVOC-MP can model contaminant behavior under 'natural' environmental conditions, as well as for engineered systems, such as soil vapor extraction, groundwater pumping, or steam-assisted source remediation. With its sophisticated parallel computing techniques, TMVOC-MP can handle much larger problems than TMVOC, and can be much more computationally efficient. TMVOC-MP models multiphase fluid systems containing variable proportions of water, non-condensible gases (NCGs), and water-soluble volatile organic chemicals (VOCs). The user can specify the number and nature of NCGs and VOCs. There are no intrinsic limitations to the number of NCGs or VOCs, although the arrays for fluid components are currently dimensioned as 20, accommodating water plus 19 components that may be either NCGs or VOCs. Among them, NCG arrays are dimensioned as 10. The user may select NCGs from a data bank provided in the software. The currently available choices include O{sub 2}, N{sub 2}, CO{sub 2}, CH{sub 4}, ethane, ethylene, acetylene, and air (a pseudo-component treated with properties averaged from N{sub 2} and O{sub 2}). Thermophysical property data of VOCs can be selected from a chemical data bank, included with TMVOC-MP, that provides parameters for 26 commonly encountered chemicals. Users also can input their own data for other fluids. The fluid components may partition (volatilize and/or dissolve) among gas, aqueous, and NAPL phases. Any combination of the three phases may present, and phases may appear and disappear in the course of a simulation. In addition, VOCs may be adsorbed by the porous medium, and may biodegrade according to a simple half-life model. Detailed discussion of physical processes, assumptions, and fluid properties used in TMVOC-MP can be found in the TMVOC user's guide (Pruess and Battistelli, 2002). TMVOC-MP was developed based on the parallel framework of the TOUGH2-MP code (Zhang et al. 2001, Wu et al. 2002). It uses the MPI (Message Passing Forum, 1994) for parallel implementation. A domain decomposition approach is adopted for the parallelization. The code partitions a simulation domain, defined by an unstructured grid, using partitioning algorithm from the METIS software package (Karypsis and Kumar, 1998). In parallel simulation, each processor is in charge of one part of the simulation domain for assembling mass and energy balance equations, solving linear equation systems, updating thermophysical properties, and performing other local computations. The local linear-equation systems are solved in parallel by multiple processors with the Aztec linear solver package (Tuminaro et al., 1999). Although each processor solves the linearized equations of subdomains independently, the entire linear equation system is solved together by all processors collaboratively via communication between neighboring processors during each iteration. Detailed discussion of the prototype of the data-exchange scheme can be found in Elmroth et al. (2001). In addition, FORTRAN 90 features are introduced to TMVOC-MP, such as dynamic memory allocation, array operation, matrix manipulation, and replacing 'common blocks' (used in the original TMVOC) with modules. All new subroutines are written in FORTRAN 90. Program units imported from the original TMVOC remain in standard FORTRAN 77. This report provides a quick starting guide for using the TMVOC-MP program. We suppose that the users have basic knowledge of using the original TMVOC code. The users can find the detailed technical description of the physical processes modeled, and the mathematical and numerical methods in the user's guide for TMVOC (Pruess and Battistelli, 2002).

58 GEOSCIENCES↗

The level-1 trigger for the SuperCDMS experiment at SNOLAB

The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to Script O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, σn, and a 99.9% trigger efficiency for signal amplitudes of 1.1 σ n in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged particle tracking in real-time using a full-mesh data delivery architecture and associative memory techniques

We present a flexible and scalable approach to address the challenges of charged particle track reconstruction in real-time event filters (Level-1 triggers) in collider physics experiments. The method described here is based on a full-mesh architecture for data distribution and relies on the Associative Memory approach to implement a pattern recognition algorithm that quickly identifies and organizes hits associated to trajectories of particles originating from particle collisions. We describe a successful implementation of a demonstration system composed of several innovative hardware and algorithmic elements. The implementation of a full-size system relies on the assumption that an Associative Memory device with the sufficient pattern density becomes available in the future, either through a dedicated ASIC or a modern FPGA. We demonstrate excellent performance in terms of track reconstruction efficiency, purity, momentum resolution, and processing time measured with data from a simulated LHC-like tracking detector.

47 OTHER INSTRUMENTATION↗

SU-F-BRF-14: Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation

Purpose: Artifacts can reduce the quality of dose re-calculations on CBCT scans during a treatment. The aim of this project is to correct the CBCT images in order to allow for more accurate and exact dose calculations in the case of a translation of the tumor in prostate cancer. Methods: Our approach is to develop strategies based on deformable image registration algorithms using the elastix software (Klein et al., 2010) to register the treatment planning CT on a daily CBCT scan taken during treatment. Sets of images are provided by a 3D deformable phantom and comprise two CT and two CBCT scans: one of both with the reference anatomy and the others with known deformations (i.e. translations of the prostate). The reference CT is registered onto the deformed CBCT and the deformed CT serves as the control for dose calculation accuracy. The planned treatment used for the evaluation of dose calculation is a 2-Gy fraction prescribed at the location of the reference prostate and assigned to 7 rectangular fields. Results: For a realistic 0.5-cm translation of the prostate, the relative dose discrepancy between the CBCT and the CT control scan at the prostate's centroid is 8.9 ± 0.8 % while dose discrepancy between the registered CT and the control scan lessens to −2.4 ± 0.8 %. For a 2-cm translation, clinical indices like the V90 and the D100 are more accurate by 0.7 ± 0.3 % and 8.0 ± 0.5 cGy respectively when using registered CT than when using CBCT for dose calculation. Conclusion: The results show that this strategy gives doses in agreement within a few percents with those from calculations on actual CT scans. In the future, various deformations of the phantom anatomy will allow a thorough characterization of the registration strategies needed for more complex anatomies.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-12: End-User Oriented Tools and Procedures for Testing Brachytherapy TPSs Employing MBDCAs

Purpose: To develop user-oriented tools for commissioning and dosimetry testing of {sup 192}Ir brachytherapy treatment planning systems (TPSs) employing model based dose calculation algorithms (MBDCAs). Methods: A software tool (BrachyGuide) has been developed for the automatic generation of MCNP6 input files from any CT based plan exported in DICOM RT format from Elekta and Varian TPSs. BrachyGuide also facilitates the evaluation of imported Monte Carlo (MC) and TPS dose distributions in terms of % dose differences and gamma index (CT overlaid colormaps or relative frequency plots) as well as DVHs and related indices. For users not equipped to perform MC, a set of computational models was prepared in DICOM format, accompanied by treatment plans and corresponding MCNP6 generated reference data. BrachyGuide can then be used to compare institutional and reference data as per TG186. The model set includes a water sphere with the MBDCA WG {sup 192}Ir source placed centrically and in two eccentric positions, a water sphere with cubic bone and lung inhomogeneities and a five source dwells plan, and a patient equivalent model with an Accelerated Partial Breast Irradiation (APBI) plan. Results: The tools developed were used for the dosimetry testing of the Acuros and ACE MBDCAs implemented in BrachyVision v.13 and Oncentra Brachy v.4.5, respectively. Findings were consistent with previous results in the literature. Besides points close to the source dwells, Acuros was found to agree within type A uncertainties with the reference MC results. Differences greater than MC type A uncertainty were observed for ACE at distances >5cm from the source dwells and in bone. Conclusion: The tools developed are efficient for brachytherapy MBDCA planning commissioning and testing. Since they are appropriate for distribution over the web, they will be put at the AAPM WG MBDCA’s disposal. Research co-financed by the ESF and Greek funds. NSRF operational Program: Education and Lifelong Learning Investing in Knowledge Society-Aristeia. Varian Medical Systems and Nucletron, an Elekta company provided access to TPSs for research purposes. Miss Peppa was supported by IKY-fellowships of excellence for postgraduate studies in Greece,Siemens Program.

60 APPLIED LIFE SCIENCES↗