Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Secondary Ion Mass Spectrometry Imaging of Dictyostelium discoideum Aggregation Streams

High resolution imaging mass spectrometry could become a valuable tool for cell and developmental biology, but both, high spatial and mass spectral resolution are needed to enable this. In this report, we employed Bi3 bombardment time-of-flight (Bi3 ToF-SIMS) and C60 bombardment Fourier transform ion cyclotron resonance secondary ion mass spectrometry (C60 FTICR-SIMS) to image Dictyostelium discoideum aggregation streams. Nearly 300 lipid species were identified from the aggregation streams. High resolution mass spectrometry imaging (FTICR-SIMS) enabled the generation of multiple molecular ion maps at the nominal mass level and provided good coverage for fatty acyls, prenol lipids, and sterol lipids. The comparison of Bi3 ToF-SIMS and C60 FTICR-SIMS suggested that while the first provides fast, high spatial resolution molecular ion images, the chemical complexity of biological samples warrants the use of high resolution analyzers for accurate ion identification.

Environmental Molecular Sciences Laboratory↗

Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2 F 2 and UO 2 (NO 3 ) 2 , U 3 O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2 F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

DOE WPTO FY2021 Seedling End Report: Coupling Soil-Foundation Models to MHK Device Dynamic Models to Tighten the Design Envelope

The purpose of this Seedling project is to couple a marine renewable energy (MRE) dynamics simulation software with the soil-foundation models in the OC6 Phase II project [Bergua et al., 2021] and evaluate the software’s performance. This is a first step to accurately evaluating soil-foundation impacts on other types of MRE, like wave or current energy converters (WECs, CECs). OC6 Phase II compares offshore wind turbine (OWT) simulations using several different soil-foundation models to identify and fill key gaps in soil-foundation analyses. WEC-Sim was chosen to model the OC6 Phase II offshore wind turbine and various load cases because of its adaptability, accuracy of hydrodynamic loads, and ability to apply an arbitrary wind loading. Of the four methods used in OC6, the apparent fixity soil-foundation method was coupled with WEC-Sim. Technical challenges with flexible hydrodynamic bodies, added mass and external function libraries inhibited the ability to compare the WEC-Sim results to other OC6 participants. These challenges required that the WEC-Sim model of the OC6 OWT use a combination of rigid and flexible bodies to ensure a numerically stable solution. The rigid monopile creates a more stiff system and causes smaller amplitude motion under hydrodynamic loading and higher dominant frequency of motion under wind loading. These discrepancies are expected based on the increased stiffness of the WEC-Sim case.

16 TIDAL AND WAVE POWER↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 µm\textsuperscript{2} in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e\textsuperscript{-} and a total dispersion of $\sim$100e\textsuperscript{-} The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4\% – 75.4\% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm\textsuperscript{2} staying within the experimental constraints.

Parpillon, Benjamin↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Constraining the Stellar-to-Halo Mass Relation with Galaxy Clustering and Weak Lensing from DES Year 3 Data

We develop a framework to study the relation between the stellar mass of a galaxy and the total mass of its host dark matter halo using galaxy clustering and galaxy-galaxy lensing measurements. We model a wide range of scales, roughly from $\sim 100 \; {\rm kpc}$ to $\sim 100 \; {\rm Mpc}$, using a theoretical framework based on the Halo Occupation Distribution and data from Year 3 of the Dark Energy Survey (DES) dataset. The new advances of this work include: 1) the generation and validation of a new stellar mass-selected galaxy sample in the range of $\log M_\star/M_\odot \sim 9.6$ to $\sim 11.5$; 2) the joint-modeling framework of galaxy clustering and galaxy-galaxy lensing that is able to describe our stellar mass-selected sample deep into the 1-halo regime; and 3) stellar-to-halo mass relation (SHMR) constraints from this dataset. In general, our SHMR constraints agree well with existing literature with various weak lensing measurements. We constrain the free parameters in the SHMR functional form $\log M_\star (M_h) = \log(εM_1) + f\left[ \log\left( M_h / M_1 \right) \right] - f(0)$, with $f(x) \equiv -\log(10^{αx}+1) + δ[\log(1+\exp(x))]^γ/ [1+\exp(10^{-x})]$, to be $\log M_1 = 11.506^{+0.325}_{-0.404}$, $\log ε= -1.632^{+0.306}_{-0.181}$, $α= -1.638^{+0.108}_{-0.099}$, $γ= 0.596^{+0.251}_{-0.210}$ and $δ= 3.810^{+2.045}_{-1.811}$. The inferred average satellite fraction is within $\sim 5-35\%$ for our fiducial results and we do not see any clear trends with redshift or stellar mass. Furthermore, we find that the inferred average galaxy bias values follow the generally expected trends with stellar mass and redshift. Our study is the first SHMR in DES in this mass range, and we expect the stellar mass sample to be of general interest for other science cases.

Zacharegkas, G. [Argonne; Chicago U., KICP] (ORCID↗

Cold Filamentary Accretion and the Formation of Metal-poor Globular Clusters and Halo Stars

We propose that cold filamentary accretion in massive galaxies at high redshifts can lead to the formation of star-forming clumps in the halos of these galaxies without dark matter substructure. In certain cases, these clumps can be the birthplaces of metal-poor globular clusters (MP GCs). Using cosmological simulations, we show that narrow streams of dense gas feeding massive galaxies from the cosmic web can fragment, producing star-forming clumps. We then derive an analytical model for the properties of streams as a function of halo mass and redshift, and assess when these are gravitationally unstable, when this can lead to collapse and star formation in the halo, and when it may result in the formation of MP GCs. For stream metallicities $\gtrsim 0.01{Z}_{\odot }$, this is likely to occur at $z\gt 4.5$. At $z\sim 6$, the collapsing clouds have masses of $\sim (5\mbox{--}10)\times {10}^{7}\,{M}_{\odot }$, and the average stream pressure is $\sim {10}^{6}\,{\mathrm{cm}}^{-3}\,{\rm{K}}$. The conditions for GC formation are met in the extremely turbulent "eyewall" at $\sim 0.3{R}_{{\rm{v}}}$, where counter-rotating streams can collide, driving very large densities. Our scenario can account for the observed kinematics and spatial distribution of MP GCs, the correlation between their mass and metallicity, and the mass ratio between the GC system and the host halo. For MW-mass halos, we infer that $\sim 30 \% $ of MP GCs could have formed in this way, with the remainder likely accreted in mergers. Our predictions for GC formation along circumgalactic filaments at high redshift are testable with JWST.

79 ASTRONOMY AND ASTROPHYSICS↗

``Beads on a String" Star Formation Tied to one of the most Powerful AGN Outbursts Observed in a Cool Core Galaxy Cluster

With two central galaxies engaged in a major merger and a remarkable chain of 19 young stellar superclusters wound around them in projection, the galaxy cluster SDSS J1531+3414 ($z=0.335$) offers an excellent laboratory to study the interplay between mergers, AGN feedback, and star formation. New Chandra X-ray imaging reveals rapidly cooling hot ($T\sim 10^6$ K) intracluster gas, with two "wings" forming a concave density discontinuity near the edge of the cool core. LOFAR $144$ MHz observations uncover diffuse radio emission strikingly aligned with the "wings," suggesting that the "wings" are actually the opening to a giant X-ray supercavity. The steep radio emission is likely an ancient relic of one of the most energetic AGN outbursts observed, with $4pV > 10^{61}$ erg. To the north of the supercavity, GMOS detects warm ($T\sim 10^4$ K) ionized gas that enshrouds the stellar superclusters but is redshifted up to $+ 800$ km s$^{-1}$ with respect to the southern central galaxy. ALMA detects a similarly redshifted $\sim 10^{10}$ M$_\odot$ reservoir of cold ($T\sim 10^2$ K) molecular gas, but it is offset from the young stars by $\sim 1{-}3$ kpc. We propose that the multiphase gas originated from low-entropy gas entrained by the X-ray supercavity, attribute the offset between the young stars and the molecular gas to turbulent intracluster gas motions, and suggest that tidal interactions stimulated the "beads on a string" star formation morphology.

79 ASTRONOMY AND ASTROPHYSICS↗

Secondary Ion Mass Spectrometry Analysis of Materials to Develop In-core Safeguards Reactor Monitoring Devices

During reactor operations and fuel burn up, some isotopic abundances change due to nuclear reactions and provide sensitive indicators of neutron fluence and fuel burnup. Secondary ion mass spectrometry (SIMS) analysis has been used to directly measure isotope ratios of selected impurity elements in irradiated nuclear reactor materials. Direct in situ SIMS measurements were made in graphite and metal samples, following shaping and surface cleaning. Other elements such as Be must be chemically separated and purified prior to SIMS analyses. Elements such as pre-existing impurity U and Pu produced from the U, are in low abundance and must also be chemically separated and are measured by thermal ionization mass spectrometry (TIMS). Studies combining SIMS and TIMS analyses demonstrate the value of this approach in determining reactor fluence profiles, power production, and other parameters. Future work proceeding from this analytical work will include developing monitoring devices designed for relatively easy placement and retrieval in a reactor, and direct SIMS analyses after exposure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 $\mu$m$^2$ in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e$^-$ and a total dispersion of $\sim$100e$^-$ The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4% - 75.4% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm$^2$ staying within the experimental constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helium Ion Microscopy with Secondary Ion Mass Spectrometry for Nanoscale Chemical Imaging and Analysis of Polyolefins

To date, chemical imaging of polymers and polymer blends has been primarily accomplished using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly visualize the distribution of components in a complex material with spatial resolution ranging from 100 nm to 5 μm. However, in many cases, this resolution falls far short of visualizing interfaces directly. To overcome these limitations, recent work has focused on developing a SIMS detection system based on a helium ion microscope (HIM) enabling chemical imaging with a demonstrated ~14 nm spatial resolution. Here, we utilize HIM-SIMS for differentiation between the olefin-based polymers of polyethylene (PE) and polypropylene (PP). We illustrate both analyses for separating PE and PP using specific mass fragment ratios as well as demonstrate spatially resolved imaging of phase-separated domains within PE. Altogether, we demonstrate the abilities of HIM-SIMS as a multimodal chemical technique for imaging and quantification of polyolefin interfaces, which could be more broadly applied to the analysis of more complex polymeric systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical and Chemical Morphology of Passively Sampled Environmental Films

Environmental surface films are important mediators in the fate and transport of persistent organic pollutants (POP) via largely uncharacterized mechanisms. This work presents the first analysis of the physical and chemical morphology of passively sampled environmental films. The films are developed in urban, sub-urban, and metropolitan locations for timescales ranging from 1 to 52 weeks by exposing polished silicon wafers to collect passively deposited tropospheric particulate matter. The time-dependent spatial morphology of the films is analyzed by bright-field, scanning electron, and atomic force microscopies. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging data are analyzed to report the film’s chemical morphology and speciation. We find that the film matrix presents an extremely complex physical and chemical system. Deposited PM sizes span six orders of magnitude (millimeter to nanometer regimes), and surface coverages range from ca. 5 % for one week films and ca. 98 % for 52 week films. We observe significant amounts of mineral dust, biogenic organics, and occasional indications of flora growth (i.e., spores). The films exhibit nanoscale surface features indicative of small particulate depositions as well as films of (semi)volatile molecules. SIMS imaging reveals diverse and sometimes segregated chemical domains of hydrocarbons, inorganics, metals, and proteinaceous macromolecules. This work presents the first spatially resolved physical and chemical surface characterization of native environmental films, beginning a study of mechanisms by which these films form, persist, and mature in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular imaging of plant-microbe interactions on the Brachypodium seed surface

Plant growth-promoting rhizobacteria (PGPR) play a crucial role in biological control and pathogenic defense on and with-in plant tissues, however the mechanism(s) by which plants associate with PGPR to elicit such beneficial effects needs further study. Here, we present high mass resolution time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of Brachypodium distachyon (Brachypodium) seeds with and without exposure to two model PGPR, i.e., Gram-negative Pseudomonas fluorescens SBW25::GFP (P.) and Gram-positive Arthrobacter chlorophenolicus A6::GFP (A.). Delayed image extraction was used to image PGPB-treated seed sections to reveal morphological changes. ToF-SIMS spectral compari-son, principal component analysis (PCA), and two-dimensional (2D) imaging show that the selected PGPR have different effects on the host seed surface, resulting in changes in chemical composition and morphology. Metabolite prod-ucts and biomarkers, such as flavonoids, phenolic com-pounds, fatty acids, and indole-3-acetic acid (IAA), were ob-served on the PGPR-treated seed surfaces. These compounds had different distributions on the Brachypodium seed surface for the two PGPR, indicating that the different bacteria elicited distinct responses from the host. Our results illustrate that ToF-SIMS is an effective tool to study plant-microbe interac-tions and to provide insightful information with submicrome-ter lateral resolution of the chemical distributions associated with morphological features, potentially offering a new way to study the mechanisms underlying beneficial roles of PGPR.

PGPR, Brachypodium distachyon, ToF-SIMS, metabolit↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE↗

Numerical Model of IProTech PIP WEC Device

iProTech PIP wave energy converter (WEC) is a slack moored, single hull device with no moving parts in the water, joints or bearings. This submission includes data of the simulation, reports, and code for the iProTech PIP (WEC) project. The organization of the data included in the provided archive is detailed below and in the data description of the archive. The data teamer-iprotech-nrel folder includes and explains matlab and python code developed to hydrodynamically model the PIP WEC device in WEC-Sim. The subfolders cover the following steps: 1) report: explanatory information on device geometry 2) pip_mesher: python code to generate mesh panels from device profile data 3) wec-sim_models: matlab code to run WEC-Sim The data uploaded is a snapshot as of 11/02/2121 of code residing in a Github repository administered by David Ogden of NREL.

16 TIDAL AND WAVE POWER↗

Sulfur isotope analysis of microcrystalline iron sulfides using secondary ion mass spectrometry imaging: Extracting local paleo-environmental information from modern and ancient sediments

Rationale: Sulfur isotope ratio measurements of bulk sulfide from marine sediments have often been used to reconstruct environmental conditions associated with their formation. In situ microscale spot analyses by secondary ion mass spectrometry (SIMS) and laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) have been utilized for the same purpose. However, these techniques are often not suitable for studying small (≤10 μm) grains or for detecting intra-grain variability. Methods: In this work, we present a method for the physical extraction (using lithium polytungstate heavy liquid) and subsequent sulfur isotope analysis (using SIMS; CAMECA IMS 7f-GEO) of microcrystalline iron sulfides. SIMS sulfur isotope ratio measurements were made via Cs + bombardment of raster squares with sides of 20–130 μm, using an electron multiplier (EM) detector to collect counts of 32 S - and 34 S - for each pixel (128 × 128 pixel grids) for between 20 and 960 cycles. Results: The extraction procedure did not discernibly alter pyrite grain-size distributions. The apparent inter-grain variability in 34 S/ 32 S in 1–4 μm-sized pyrite and marcasite fragments from isotopically homogeneous hydrothermal crystals was ~ ±2‰ (1σ), comparable with the standard error of the mean for individual measurements (≤ ±2‰, 1σ). In contrast, grain-specific 34 S/ 32 S ratios in modern and ancient sedimentary pyrites and marcasites can have inter- and intra-grain variability >60‰. The distributions of intra-sample isotopic variability are consistent with bulk 34 S/ 32 S values. Conclusions: SIMS analyses of isolated iron sulfide grains yielded distributions that are isotopically representative of bulk 34 S/ 32 S values. Populations of iron sulfide grains from sedimentary samples record the evolution of the S-isotopic composition of pore water sulfide in their S-isotopic compositions. These data allow past local environmental conditions to be inferred.

59 BASIC BIOLOGICAL SCIENCES↗

NanoSIMS Imaging Alternation Layers of a Leached SON68 Glass Via A FIB-made Wedged Crater

Currently, nuclear wastes are commonly immobilized into glasses because of their long-term durability. Exposure to water for long periods of time, however, will eventually corrode the waste form and is the leading potential avenue for radionuclide release into the environment. Because such slow processes cannot be experimentally tested, the prediction of release requires a thorough understanding the mechanisms governing glass corrosion. In addition, due to the exceptional durability of glass, much of the testing must be performed on high-surface-area powders. A technique that can provide accurate compositional profiles with very precise depth resolution for non-flat samples would be a major benefit to the field. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling is an excellent tool that has long been used to examine corrosion layers of glass. The roughness of the buried corrosion layers, however, causes the corresponding SIMS depth profiles to exhibit erroneously wide interfaces. In this study, NanoSIMS was used to image the cross-section of the corrosion layers of a leached SON68 glass sample. A wedged crater was prepared by a focused ion beam (FIB) instrument to obtain a 5× improvement in depth resolution for NanoSIMS measurements. This increase in resolution allowed us to confirm that the breakdown of the silica glass network is further from the pristine glass than a second dissolution front for boron, another glass former. The existence of these two distinct interfaces, separated by only ~20 nm distance in depth, was not apparent by traditional ToF-SIMS depth profiling but has been confirmed also by atom probe tomography. This novel sample geometry will be a major benefit to efficient NanoSIMS sampling of irregular interfaces at the nanometer scale that would otherwise be obscured within ToF-SIMS depth profiles.

Environmental Molecular Sciences Laboratory↗