Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Discovery of the Neutron Star Spin Frequency in EXO 0748-676

We report the results of a search for burst oscillations during thermonuclear X-ray bursts from the low mass X-ray binary (LMXB) EXO 0748-676. With the proportional counter array (PCA) onboard the Rossi X-ray Timing Explorer (RXTE) we have detected a 45 Hz oscillation in the average power spectrum of 38 thermonuclear X-ray bursts from this source. We computed power spectra with 1 Hz frequency resolution for both the rising and decaying portions of 38 X-ray bursts from the public RXTE archive. We averaged the 1 Hz power spectra and detected a significant signal at 45 Hz in the decaying phases of the bursts. The signal is detected at a significance level of 4 x 10 (exp -8) similar signal was detected in the rising intervals. The oscillation peak is unresolved at 1 Hz frequency resolution, indicating an oscillation quality factor, Q = nu (sub 0)/Delta nu (sub fwhm) greater than 45, and the average signal amplitude is approximately equal to 3% (rms) The detection of 45 Hz burst oscillations from EXO 0748-676 provides compelling evidence that this is the neutron star spin frequency in this system. We use the inferred spin frequency to model the widths of absorption lines from the neutron star surface and show that the widths of the absorption lines from EXO 0748-676 recently reported by Cottam et al. are consistent with a 45 Hz spin frequency as long as the neutron star radius is in the range from about 9.5 - 15 km. With a known spin frequency, precise modelling of the line profiles from EXO 0748-676 holds great promise for constraining the dense matter equation of state.

Villarreal, Adam R.↗

L-orthogonal signal transmission and detection.

Investigation of the detailed capabilities and performance characterization of systems that employ L-orthogonal signaling techniques. L-orthogonal signals represent a unified set of signals wherein the polyphase and orthogonal (bi-orthogonal) signal sets are included as special cases. This fact is important, since orthogonal (bi-orthogonal) and polyphase signaling sets represent opposing forces as far as tradeoffs between error probability, energy-to-noise ratio, and bandwidth requirements are concerned. Bounds on the performance of the optimum receiver and the performance of various suboptimum (practical) receiver structures are given. Coherent and differentially coherent detection of differentially encoded signals are also pursued. Various comparisons and tradeoffs are made by means of numerical evaluation of the error probability expressions.

Lindsey, W. C.↗

Modulation and detection of optical signals

A summary of information is presented which is related to the modulation and detection of information on optical carriers. It emphasizes the treatment of information transfer through an entire system. The most common configurations are considered: intensity modulation, amplitude modulation, frequency or phase modulation, and both direct and coherent detection. In assessing these configurations information capacity and message signal-to-noise ratio are used as a basis of comparison. The physical and geometric treatment of optical heterodyne (or coherent) detection is given.

Goodwin, F. E.↗

Noncoherent detection of periodic signals

The optimal Bayes detector for a general periodic waveform having uniform delay and additive white Gaussian noise is examined. It is shown that the detector is much more complex than that for the well known cases of pure sine waves (i.e. classical noncoherent detection) and narrowband signals. An interpretation of the optimal processing is presented, and several implementations are discussed. The results have application to the noncoherent detection of optical square waves.

Gagliardi, R. M.↗

Effect of noisy phase reference on coherent detection of unbalanced QPSK signals

A phase error in the reference signal used in coherent detection of PSK signals causes a degradation in performance; this effect on bit error probability has been much discussed in the literature for BPSK and balanced QPSK systems. For unbalanced QPSK (UQPSK) systems, where the power and data rates in the two channels are unequal, and where the channel data symbols might also be different, the problem of computing the error probability is more complex, and only approximate solutions have been previously given. In this paper, exact expressions are derived for the conditional probability of error for the I and Q channels as a function of the channel power and data rate ratio. This is done for all combinations of Manchester and NRZ signalling schemes, and it is shown that in some cases the low data rate channel can be more seriously affected by a phase offset. Numerical results are also given for the average probability of error, assuming a biphase Costas loop is used for carrier synchronization.

Osborne, H. C.↗

Near optimum delay-line detection filters for serial detection of MSK signals

A method for designing transversal delay-line filter approximations to the matched filter for the serial detection of minimum-shift keyed (MSK) modulated signals is given. Two configurations are characterized in terms of signal-to-noise ratio degradation at a bit error rate (BER) of 10 to the -6th. One is shown to depart less than 0.3 dB from the ideal matched filter performance when its parameter values are optimized. A lumped-element equivalent is also given and shown to provide a degradation of less than 0.4 dB at a BER of 10 to the -6th

Ziemer, R. E.↗

Detecting a periodic signal in the terrestrial cratering record

A time-series analysis of model periodic data, where the period and phase are known, has been performed in order to investigate whether a significant period can be detected consistently from a mix of random and periodic impacts. Special attention is given to the effect of age uncertainties and random ages in the detection of a periodic signal. An equivalent analysis is performed with observed data on crater ages and compared with the model data, and the effects of the temporal distribution of crater ages on the results from the time-series analysis are studied. Evidence for a consistent 30-m.y. period is found to be weak.

Grieve, Richard A. F.↗

A new method for the detection of a periodic signal of unknown shape and period

A method was developed for the detection and measurement of a periodic signal with unknown characteristics in a data set where the existence of such signal was not known. The method detects a signal by using Bayesian probability theory to compare a constant model for the signal to members of a class of models with periodic structure. The method was applied to simulated data generated with both stepwise and sinusoidal light curves, demonstrating that such signals can be sensitively detected and the signal frequency and its shape can be accurately estimated.

Gregory, P. C.↗

A Multi-Scale Sampling Strategy for Detecting Physiologically Significant Signals in AVIRIS Imagery

Models of photosynthetic production at ecosystem and global scales require multiple input parameters specifying physical and physiological surface features. While certain physical parameters (e.g., absorbed photosynthetically active radiation) can be derived from current satellite sensors, other physiologically relevant measures (e.g., vegetation type, water status, carboxylation capacity, or photosynthetic light-use efficiency), are not generally directly available from current satellite sensors at the appropriate geographic scale. Consequently, many model parameters must be assumed or derived from independent sources, often at an inappropriate scale. An abundance of ecophysiological studies at the leaf and canopy scales suggests strong physiological control of vegetation-atmosphere CO2 and water vapor fluxes, particularly in evergreen vegetation subjected to diurnal or seasonal stresses. For example hot, dry conditions can lead to stomatal closure, and associated "downregulation" of photosynthetic biochemical processes, a phenomenon often manifested as a "midday photosynthetic depression". A recent study with the revised simple biosphere (SiB2) model demonstrated that photosynthetic downregulation can significantly impact global climate. However, at the global scale, the exact significance of downregulation remains unclear, largely because appropriate physiological measures are generally unavailable at this scale. Clearly, there is a need to develop reliable ways of extracting physiologically relevant information from remote sensing. Narrow-band spectrometers offer many opportunities for deriving physiological parameters needed for ecosystem and global scale photosynthetic models. Experimental studies on the ground at the leaf- to stand-scale have indicated that several narrow-band features can be used to detect plant physiological status. One physiological signal is caused by xanthophyll cycle pigment activity, and is often expressed as the Photochemical Reflectance Index (PRI). Because the xanthophyll cycle pigments are photoregulatory pigments closely linked to photosynthetic function, this index can be used to derive relative photosynthetic rates. An additional signal with physiological significance is the 970 nm water absorption band, which provides a measure of liquid water content. This feature has been quantified both using a simple 2-band ratio (900/970 nm, here referred to as the "Water Band Index" or WBI;), and using the "continuum removal" method. Current atmospheric correction methods for AVIRIS imagery also obtain quantitative expressions of surface liquid water absorption based on the 970 nm water band and may be comparable to ground-based estimates of water content using this feature. However, physiological interpretations of both the PRI and the WBI are best understood at the leaf and canopy scales, where complications of atmospheric interference and complex stand and landscape features can be minimized, and where experimental manipulations can be readily applied. Currently it is not known whether these physiological indices can be used to derive meaningful physiological information from AVIRIS imagery. In addition to the problem of atmospheric interference, another challenge is that any simple physiological index can be confounded by multiple factors unrelated to physiology, and this problem can become more severe at progressively larger spatial scales. For example, previous work has suggested that both the PRI and the WBI, are strongly correlated with other optical measures of canopy structure (e.g., the Normalized Difference Vegetation Index or green vegetation fraction), indicating a confounding effect of structure on physiological signals at the larger, landscape scale. Furthermore, the normal operating mode of most imaging spectrometers does not allow simultaneous, ground truthing at a level of detail needed for physiological sampling. Additionally, manipulative experiments of physiology are difficult to apply at a geographic scale suitable for comparison with remote imagery, which often works at spatial scales that are several orders of magnitude larger than those typically used for physiological studies. These limitations require the consideration of alternative approaches to validating physiological information derived from AVIRIS data. In this report, we present a multi-scale sampling approach to detecting physiologically significant signals in narrow-band spectra. This approach explores the multi-dimensional data space provided by narrow-band spectrometry, and combines AVIRIS imagery at a large scale, with ground spectral sampling at an intermediate scale, and detailed ecophysiological measurements at a fine scale, to examine seasonally and spatially changing relationships between multiple structural and physiological variables. Examples of this approach are provided by simultaneous sampling of the Normalized Difference Vegetation Index (NDVI), an index of fractional PAR interception and green vegetation cover, the Water Band Index (WBI, an index of liquid water absorption, and the Photochemical Reflectance Index (PRI, an index of xanthophyll cycle pigment activity and photosynthetic light-use efficiency. By directly linking changing optical properties sampled on the ground with measurable physiological states, we hope to develop a basis for interpreting similar signals in AVIRIS imagery.

Gamon, John A.↗

RF processing

The Loran-C radio frequency processing is discussed. A diagram which generally illustrates the automatic gain control is presented. The augmented differentiator for pulse envelopes adapts conventional communications receiver with wideband AM capability to detect pulse signals such as Loran-C. The circuit enhances reception for surveillance and observation of HF over-the-horizon radar signals or others where time difference estimates between pulse returns are of interest. The high resolution VLF spectrum which receives weak VLF signals by using an HP 3581A wave analyzer detecting signals with a very narrow bandwidth of only 3 Hz is also presented.

Burhans, R. W.↗

On the detection of differentially encoded polyphase signals.

Discussion of the transmission and detection of differentially encoded polyphase signals and of the ambiguity resolution problem which results from suppression of the transmitted carrier. In particular, an analysis is made of the performance of differentially encoded coherent multiple phase-shift keyed (MPSK) systems which reconstruct coherent reference signals by means of generalized Costas or nth-power loops. The performance of such systems is then compared with that of ideal reception of MPSK signals and differentially coherent detection of differentially encoded MPSK signals. Emphasis is placed upon the special cases of quadriphase and octaphase signaling.

Lindsey, W. C.↗

Automated Detection of Spurious Signals in VLBI Phase Calibration Data

In this memorandum, a set of processing strategies for automatic masking of phase calibration tones is outlined as implemented in the software package PIMA in the task Generate Phase Calibration Mask, or GEPM. The task relies on a robust procedure of cleaning phase calibration data before employing several mathematical strategies designed to selectively identify spurious signals from phase calibration tones. These strategies were derived as more rigorous implementations of heuristics traditionally used by analysts in manually identifying problematic phase calibration data. The task is intended to automate the process of generating a phase calibration mask and in so doing increase the speed and regularity of VLBI analysis. At the outset of the project, a series of goals were identified to evaluate the success of this mask generation. This included the development of an algorithm to identify and mask short-term (defined as less than 10 seconds in length) spurious signals affecting phase calibration data, the development of an algorithm to identify and mask phase calibration tones affected by constant radio-frequency interference, the implementation of a detection scheme for identifying large jumps in phase calibration phase caused by clock breaks, and finally a method of reporting phase calibration health metrics to the user. Processing of over 10 experiments has demonstrated that the final form of the task GEPM as detailed in this technical memorandum satisfies each of these conditions and satisfactorily performs the task of automatic phase calibration data masking, although the wide variety in quality and characteristics of phase calibration data makes a single solution to the problem quite difficult. A series of user inputs have therefore been defined to assist analysts in tailoring automatic masking to specific stations and phase calibration generators. The vast majority of applicable code was written in FORTRAN to increase execution speed and ease of interfacing with the existing code base in PIMA, but a wrapper function in Python was also written to allow for a simpler method of interacting with GEPM and inputting relevant parameters. In addition to this report, thorough documentation was added to the already existing repositories associated with PIMA as a whole.

Geodesy↗