Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Human versus automation in responding to failures: an expected-value analysis

A simple analytical criterion is provided for deciding whether a human or automation is best for a failure detection task. The method is based on expected-value decision theory in much the same way as is signal detection. It requires specification of the probabilities of misses (false negatives) and false alarms (false positives) for both human and automation being considered, as well as factors independent of the choice--namely, costs and benefits of incorrect and correct decisions as well as the prior probability of failure. The method can also serve as a basis for comparing different modes of automation. Some limiting cases of application are discussed, as are some decision criteria other than expected value. Actual or potential applications include the design and evaluation of any system in which either humans or automation are being considered.

NASA Discipline Space Human Factors↗

Implementing time resolved electron temperature capability at the NIF using a streak camera

A new capability on NIF has been implemented to measure the temperature of x-ray emitting sources. Although it is designed primarily for Inertial Confinement Fusion (ICF), it can be used for any hot emitting source that is well modeled. The electron temperature (T e ) of the hot spot within the core of imploded inertial confinement fusion capsules is an effective indicator of implosion performance. Currently, there are spatially and temporally integrated T e inferences using image plates. A temporally resolved measurement of Te will help elucidate the mechanisms for hot spot heating and cooling such as conduction to fuel, alpha-heating, mix and radiative losses. To determine the temporally resolved T e of hot spots, specific filters are added to an existing x-ray streak camera “Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER)” to probe the emission spectrum during the x-ray burn history of implosions on the National Ignition Facility (NIF). One of the difficulties in inferring the hot spot temperature is the attenuation of the emission due to opacity from the shell and fuel. Therefore, a series of increasingly thick titanium filters were implemented to isolate the emission in specific energy regions that are sensitive to temperatures above 3keV while not significantly influenced by the shell/fuel attenuation. Additionally, a relatively thin zinc filter was used to measure the contribution of colder emission sources. Since the signal levels of the emission through the thicker filters are relatively poor, a dual slit (aperture) was designed to increase detected signal at the higher end of the spectrum. Herein, the design of the filters and slit are described, an overview of the solving technique is provided, and initial electron temperature results are reported.

47 OTHER INSTRUMENTATION↗

Apollo 12, 15, and 16 lunar surface magnetometer experiment data analysis

The polarization of magnetometer signals detected at the Apollo 15 Hadley site by the lunar surface magnetometer has been studied to determine the source of the signal anisotropy which is observed and caused by the polarization. Instrument and data chain malfunction (cross-talk) seems ruled out. The source appears real and apparently connected with the Imbrium basin using reasonable inferences regarding the electromagnetic structure of the Moon. A theory is developed using moons with holes and conducting caps where the Imbrium basin is; results of calculations are consistent, though not unique, in specifying an anomaly in the electrical conductivity underlying Mare Imbrium. Distinct differences are noted from plasma sheet and diamagnetic cavity transfer functions, but the lobes appear, as for all other data, not to be vacuum for study of the moon. A discussion is given of problems connected with transfer of data, software, and theoretical programs from NASA Ames Research Center to the University of Arizona, and a summary is given of the conversion from IBM to CDC formats.

Sonett, C. P.↗

Frequency domain laser velocimeter signal processor

A new scheme for processing signals from laser velocimeter systems is described. The technique utilizes the capabilities of advanced digital electronics to yield a signal processor capable of operating in the frequency domain maximizing the information obtainable from each signal burst. This allows a sophisticated approach to signal detection and processing, with a more accurate measurement of the chirp frequency resulting in an eight-fold increase in measurable signals over the present high-speed burst counter technology. Further, the required signal-to-noise ratio is reduced by a factor of 32, allowing measurements within boundary layers of wind tunnel models. Measurement accuracy is also increased up to a factor of five.

Meyers, James F.↗

Surface Charge Densities and Acidities of Biogeochemically Important Organic Adlayers at Mineral/Water Interfaces Studied by Nonlinear Optics

At a given bulk solution pH, mineral/water interfaces contain a corresponding number of charged and neutral species consisting of either SiOH, SiO - and SiOH 2 + groups in the case of fused quartz or of Si-R-COOH and Si-R-COO - groups in the case of the carboxylic acid-functionalized fused quartz/water interfaces. In the "$\chi^{(3)}$ method", as it has been termed by Eisenthal and co-workers who pioneered it and which is related to electric field induced SHG (EFISH), the SHG E-field depends on the interfacial potential that is produced by the interfacial charges. In the $\chi^{(3)}$ method, the SHG E-field is modeled with the familiar second-order response11 to which one adds a third-order term according to E SHG =$\chi^{(2)}$ E ω E ω + $\chi^{(3)}$ E ω E ω Φ o . The third order response is given by the product of the third order nonlinear susceptibility, $\chi^{(3)}$, the two applied electromagnetic probe fields oscillating at frequency ω, E ω , and the interfacial potential, Φ o , which is produced by the interfacial charges, the corresponding spatial distribution of the counter charges, and dipolar arrays of aligned water molecules, whose structure and dynamics have been studied using sum frequency generation. Note that the localization of the protonatable and deprotonatable groups at the interface and the high sensitivity of the $\chi^{(3)}$ method to the Φ o make the experiment interface-specific. In addition, the signal detection formalism can be viewed as a self-heterodyned detection scheme in which the second order response would be the local oscillator and the third order response would be the signal. As part of work focusing on metal ion adsorption to oxide/water interfaces, we published $\chi^{(3)}$ charge screening experiments carried out on fused quartz/water and single crystal α-alumina/water interfaces that agree very well with data by Eisenthal and coworkers as well as Higgins et al.

58 GEOSCIENCES↗

Low-Energy Radon Backgrounds from Electrode Grids in Dual-Phase Xenon TPCs

The dual-phase xenon time projection chamber (TPC) is a powerful technology to detect rare interactions such as scatters of dark matter particles on nuclei. In particular, the built-in gain of ionization signals in a dual-phase TPC makes it sensitive to events in the few-electron regime, as expected from low-mass dark matter interactions. The pursuit of this low-energy sensitivity through ionization-only signal detection has so far been hindered by excessive electron backgrounds observed across experiments. Much of this background is attributed to the plate-out of $^{222}$Rn decay chain isotopes on the high voltage electrode grid surfaces that span the full cross section of the TPC. This work presents a first-principle model constructed for this background, the predictions of which are consistent with data from the LZ and LUX experiments. We then discuss mitigation strategies of this background in future dual-phase TPCs and the possibility of applying this grid background model to ionization-only dark matter searches.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

The Effect of Set Size on the Relation Between Saccadic and Perceptual Decisions During Search

We have shown that when searching for a disk in noise at one of 10 locations, the accuracy of the I st saccade is similar to that of the perceptual decision at the time of saccadic programming. The present study has two goals: 1) to test whether this linden - extends to a contrast-discrimination task without noise, and 2) to measure the effect of set size on the relation between saccadic and perceptual decisions. Methods: Three observers searched over a grey background (34.5 cd/sq m) for a bright disk (63.2 cd/sq m) among dim disks (54.1 cd/sq m) along the circumference of a circle (r = 5.9 deg.) centered on a fixation cress. Four set sizes (2, 4, 6, 12) were used. In the 1st condition, stimuli were presented for 1 sec. and observers used natural eye movements. We then measured the accuracy of the first saccade (% correct using a shortest-distance criterion). In the 2nd condition, observers fixated a central cross at all times and the stimulus duration was approx. 70 as less than the median latency of the first saccade in the 1st condition (saccadic programming time). We then recorded perceptual performance and discarded trials in which observers broke fixation. Results: For set sizes of 2, 4, 8, and 12, the mean d' across observers for the perceptual decision was 2.03, 1.96, 1.94, 1.71, respectively, while the mean d' of the first saccade was only 0.73, 1.40, 1.23, 1.17. Conclusions: Unlike detection of a disk in noise, for all observers and set-sizes, the perceptual accuracy at the time of saccadic programming is better than that of the lst saccade. For set-sizes of 4, 6, and 12, the amount of information available to the perceptual system relative to that available to the saccadic system is approximately constant (fixed do ratio). For these higher set sizes, the constancy in do across set size for both perception and saccadic decisions is consistent with a simple signal detection theory (SDT) model that processes noisy signals in parallel. However, for 2 observers, at a set-size of 2, saccadic targeting appears to be worse than the SDT model prediction, perhaps due to speed-accuracy trade-off.

Eckstein, M. P.↗

Coherent lidar design and performance verification

The verification of LAWS beam alignment in space can be achieved by a measurement of heterodyne efficiency using the surface return. The crucial element is a direct detection signal that can be identified for each surface return. This should be satisfied for LAWS but will not be satisfied for descoped LAWS. The performance of algorithms for velocity estimation can be described with two basic parameters: the number of coherently detected photo-electrons per estimate and the number of independent signal samples per estimate. The average error of spectral domain velocity estimation algorithms are bounded by a new periodogram Cramer-Rao Bound. Comparison of the periodogram CRB with the exact CRB indicates a factor of two improvement in velocity accuracy is possible using non-spectral domain estimators. This improvement has been demonstrated with a maximum-likelihood estimator. The comparison of velocity estimation algorithms for 2 and 10 micron coherent lidar was performed by assuming all the system design parameters are fixed and the signal statistics are dominated by a 1 m/s rms wind fluctuation over the range gate. The beam alignment requirements for 2 micron are much more severe than for a 10 micron lidar. The effects of the random backscattered field on estimating the alignment error is a major problem for space based lidar operation, especially if the heterodyne efficiency cannot be estimated. For LAWS, the biggest science payoff would result from a short transmitted pulse, on the order of 0.5 microseconds instead of 3 microseconds. The numerically errors for simulation of laser propagation in the atmosphere have been determined as a joint project with the University of California, San Diego. Useful scaling laws were obtained for Kolmogorov atmospheric refractive turbulence and an atmospheric refractive turbulence characterized with an inner scale. This permits verification of the simulation procedure which is essential for the evaluation of the effects of refractive turbulence on coherent Doppler lidar systems. The analysis of 2 micron Doppler lidar data from Coherent Technologies, Inc. (CTI) has demonstrated many of the advantages of doppler lidar measurements of boundary layer winds. The effects of wind shear and wind turbulence over the pulse volume are probably the dominant source of the reduced performance. The effects of wind shear and wind turbulence on the statistical description of doppler lidar data has been derived and calculated.

Frehlich, Rod↗

Robust Infrasound Detection via Deep Learning (RIDDL)

RIDDL is a suite of software tools that enable AI/ML analysis of infrasound data. Methods and capabilities include construction, evaluation, and application of models for infrasound signal analysis, construction of synthetic data useful for construction and evaluation, as well as various other advanced data science tools enabling infrasound signal detection and categorization as well as downstream analysis methods such as localization and characterization of detected sources.

Blom, Philip↗

Seismic Array Analysis Using Fiber-Optic Distributed Acoustic Sensing on Small Local and Regional Earthquakes

We examined the feasibility of using fiber-optic Distributed Acoustic Sensing (DAS) as an alternative to a traditional seismic array. Seismic arrays are used routinely globally to measure waveform propagation parameters and signal features including back-azimuth (BAZ) and apparent horizontal velocity through the process of beamforming or frequency-wavenumber (f-k) array analysis with the assumption that the signals travel across the array as a plane-wave. These measurements are useful for identifying signal detections as teleseismic, regional, or local distance seismic phases based on their velocities traveling across the array (e.g., Rost and Thomas, 2001). Signal enhancement is the main benefit of array processesing through the stacking of multiple channels as a phased array. This enhancement increases as the square root of the number of channels relative to a single seismic station (e.g., Rost and Thomas, 2001), which is a factor of 3 from a typical nine-channel array. DAS provides the potential of stacking waveforms from 100’s to 1000’s of channels. However, DAS is a novel technology designed for geophysical exploration and therefore has some limitations which we will explore. We started with the dataset from the PoroTomo project because of its unique experimental layout of colocated geophone array and DAS deployment so the two recording technologies can be compared side-by-side.

58 GEOSCIENCES↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

An Automatic Light Rain Detection Algorithm on NASA MPLNET Lidar Observations in the Frame of WMO GALION Project

The water cycle strongly influences life on Earth. In particular, the precipitation modifies the atmospheric column thermodynamics through the process of evaporation and serves as a proxy for latent heat modulation. For this reason, a correct precipitation parameterization (especially low-intensity precipitation) at global scale, bedsides improving our understanding of the hydrological cycle, it is crucial to reduce the associated uncertainty of the global climate models to correctly forecast future scenarios, i.e. to apply fast mitigation strategies. In this study we developed an algorithm to automatically detect precipitation from lidar measurements obtained by the National and Aeronautics Space Administration (NASA) Micropulse lidar network (MPLNET) permanent observational site in Goddard. The algorithm, once full operational, will deliver in Near Real Time (latency 1.5h) a new rain mask product that will be publicly available on MPLNET website as part of the new Version 3 Level 1.5 data. The methodology, based on an image processing technique, can detect only light precipitation events (defined by intensity and duration) as the morphological filters used through the detection process are applied on the lidar volume depolarization ratio range corrected composite images, i.e. heavy rain events are unusable as the lidar signal is completely extinguished after few meters in the precipitation or no signal detected because of the water accumulated on the receiver optics. Results from the algorithm, besides filling a gap in precipitation and virga detection by radars, are of particular interest for the scientific community because will help to better understand long-term aerosol-cloud interactions and aerosol atmospheric removal (scavenging effect) by rain as multi-year database being available for several MPLNET permanent observational sites across the globe. Moreover, we developed the automatic algorithm at Universitat Politecnica de Catalunya (UPC) Barcelona, the unique permanent observation station member of MPLNET and the European Aerosol Lidar Network (EARLINET) In the future the algorithm can be then easily applied to any other lidar and/or ceilometer network infrastructure in the frame of World Meteorological Organization (WMO) Global Aerosol Watch (GAW) aerosol lidar observation network (GALION)

Simone Lolli↗

Features and Characteristics of the New NASA MicroPuLse NETwork (MPLNET) Automatic Rain Detection Algorithm

The water cycle strongly influences life on Earth. In particular, the precipitation modifies the atmospheric column thermodynamics through the process of evaporation and serves as a proxy for latent heat modulation. For this reason, a correct precipitation parameterization (especially low-intensity precipitation) at global scale, bedsides improving our understanding of the hydrological cycle, it is crucial to reduce the associated uncertainty of the global climate models to correctly forecast future scenarios, i.e. to apply fast mitigation strategies. In this study we developed an algorithm to automatically detect precipitation from lidar measurements obtained by the National and Aeronautics Space Administration (NASA) Micropulse lidar network (MPLNET) permanent observational site in Goddard. The algorithm, once full operational, will deliver in Near Real Time (latency 1.5h) a new rain mask product that will be publicly available on MPLNET website as part of the new Version 3 Level 1.5 data. The methodology, based on an image processing technique, can detect only light precipitation events (defined by intensity and duration) as the morphological filters used through the detection process are applied on the lidar volume depolarization ratio range corrected composite images, i.e. heavy rain events are unusable as the lidar signal is completely extinguished after few meters in the precipitation or no signal detected because of the water accumulated on the receiver optics.

S. Lolli↗

Evaluating the location capabilities of a regional infrasonic network in Utah, US, using both ray tracing-derived and empirical-derived celerity-range and backazimuth models

SUMMARY More realistic models for infrasound signal propagation across a region can be used to improve the precision and accuracy of spatial and temporal source localization estimates. Motivated by incomplete infrasound event bulletins in the Western US, the location capabilities of a regional infrasonic network of stations located between 84–458 km from the Utah Test and Training Range, Utah, USA, is assessed using a series of near-surface explosive events with complementary ground truth (GT) information. Signal arrival times and backazimuth estimates are determined with an automatic F-statistic based signal detector and manually refined by an analyst. This study represents the first application of three distinct celerity-range and backazimuth models to an extensive suite of realistic signal detections for event location purposes. A singular celerity and backazimuth deviation model was previously constructed using ray tracing analysis based on an extensive archive of historical atmospheric specifications and is applied within this study to test location capabilities. Similarly, a set of multivariate, season and location specific models for celerity and backazimuth are compared to an empirical model that depends on the observations across the infrasound network and the GT events, which accounts for atmospheric propagation variations from source to receiver. Discrepancies between observed and predicted signal celerities result in locations with poor accuracy. Application of the empirical model improves both spatial localization precision and accuracy; all but one location estimates retain the true GT location within the 90 per cent confidence bounds. Average mislocation of the events is 15.49 km and average 90 per cent error ellipse areas are 4141 km2. The empirical model additionally reduces origin time residuals; origin time residuals from the other location models are in excess of 160 s while residuals produced with the empirical model are within 30 s of the true origin time. We demonstrate that event location accuracy is driven by a combination of signal propagation model and the azimuthal gap of detecting stations. A direct relationship between mislocation, error ellipse area and increased station azimuthal gaps indicate that for sparse networks, detection backazimuths may drive location biases over traveltime estimates.

58 GEOSCIENCES↗

Mid-infrared photodetection in an AlGaAs/GaAs quantum-well infrared photodetector using photoinduced noise

We propose a new way to assess the output signal of a quantum-well infrared photodetector (QWIP). Instead of measuring the photocurrent produced by the device, as usually done, we show that the noise induced by the absorption process can be used to generate a useful detection signal. We built a simple electronic circuit able to quantify the noise of an AlGaAs/GaAs QWIP that was intentionally designed to produce no photocurrent at all, and we demonstrated that such a circuit was able to generate a strong output signal whenever an infrared radiation of a specific wavelength was shed on the detector. This concept opens new possibilities for the design of novel types of photodetection systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gravitational wave, collider and dark matter signals from a scalar singlet electroweak baryogenesis

We analyse a simple extension of the SM with just an additional scalar singlet coupled to the Higgs boson. Here, we discuss the possible probes for electroweak baryogenesis in this model including collider searches, gravitational wave and direct dark matter detection signals. We show that a large portion of the model parameter space exists where the observation of gravitational waves would allow detection while the indirect collider searches would not.

79 ASTRONOMY AND ASTROPHYSICS↗

An adaptable multiple power source for mass spectrometry and other scientific instruments

Power supplies are commonly used in the operation of many types of scientific equipment, including mass spectrometers and ancillary instrumentation. A generic modern mass spectrometer comprises an ionization source, such as electrospray ionization (ESI), ion transfer devices such as ion funnels and multipole ion guides, and ion signal detection apparatus. Very often such platforms include, or are interfaced with ancillary elements in order to manipulate samples before or after ionization. In order to operate such scientific instruments, numerous direct current (DC) channels and radio frequency (RF) signals are required, along with other controls such as temperature regulation. In particular, DC voltages in the range of ±400 V, along with MHz range RF signals with peak-to-peak amplitudes in the hundreds of volts range are commonly used to transfer ionized samples under vacuum. Additionally, an ESI source requires a high voltage (HV) DC source capable of producing several thousand volts and heaters capable of generating temperatures up to 300°C. All of these signals must be properly synchronized and managed in order to carry out ion trapping, accumulation and detection.

47 OTHER INSTRUMENTATION↗