At least 415 records · Page 23

A geostatistics-informed hierarchical sensitivity analysis method for complex groundwater flow and transport modeling

Sensitivity analysis is an important tool for development and improvement of mathematical models, especially for complex systems with a high dimension of spatially correlated parameters. Variance-based global sensitivity analysis has gained popularity because it can quantify the relative contribution of uncertainty from different sources. However, its computational cost increases dramatically with the complexity of the considered model and the dimension of model parameters. As such, in this study, we developed a new sensitivity analysis method that integrates the concept of variance-based method with a hierarchical uncertainty quantification framework. Different uncertain inputs are grouped and organized into a multilayer framework based on their characteristics and dependency relationships to reduce the dimensionality of the sensitivity analysis. A set of new sensitivity indices are defined for the grouped inputs using the variance decomposition method. Using this methodology, we identified the most important uncertainty source for a dynamic groundwater flow and solute transport model at the Department of Energy (DOE) Hanford site. The results indicate that boundary conditions and permeability field contribute the most uncertainty to the simulated head field and tracer plume, respectively. The relative contribution from each source varied spatially and temporally. By using a geostatistical approach to reduce the number of realizations needed for the sensitivity analysis, the computational cost of implementing the developed method was reduced to a practically manageable level. The developed sensitivity analysis method is generally applicable to a wide range of hydrologic and environmental problems that deal with high-dimensional spatially distributed input variables.

58 GEOSCIENCES↗

Ultra-sensitive surface plasmon resonance biosensor based on MoS{sub 2}–graphene hybrid nanostructure with silver metal layer

The optical biosensors based on the plasmonic technology are an important research item in the field of biophotonics. The graphene–molybdenum disulfide (MoS{sub 2}) based hybrid structures are very effective in designing and fabricating of the sensitive optical biosensors. In this paper, we propose a nanostructure Ag/MoS{sub 2}/graphene as an optical biosensor with high performance and sensitivity. The proposed configuration for this surface plasmon resonance (SPR) optical biosensor is Kretschmann. Herein, the enhancement of sensitivity for the proposed SPR optical biosensor is investigated in different states. By determining of the numbers of MoS{sub 2} layer and the thickness of the metal layer, we increased the sensitivity of the proposed biosensor. The maximum sensitivity ~ 190°/RIU is achieved. For this ultra-sensitive SPR biosensor with maximum sensitivity, the numbers of MoS{sub 2} and graphene layer is 2 and the resonance wavelength is determined 680 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Adjoint-based sensitivity analysis for high-energy density radiative transfer using flux-limited diffusion

Uncertainty quantification and sensitivity analyses are a vital component for predictive modeling in the sciences and engineering. The adjoint approach to sensitivity analysis requires solving a primary system of equations and a mathematically related set of adjoint equations. The information contained in the equations can be combined to produce sensitivity information in a computationally efficient manner. Here in this work, sensitivity analyses are performed on systems described by flux-limited radiative diffusion using the adjoint approach. The sensitivities computed are shown to agree with standard perturbation theory and require significantly less computational time. The adjoint approach saves the computational cost of one forward solve per sensitivity, making the method attractive when multiple sensitivities are of interest.

42 ENGINEERING↗

Classification of sensitizing and irritative potential in a combined in-vitro assay

We have developed a coculture system which in parallel indicates the sensitizing and irritative potential of xenobiotics. The assay is named loose-fit coculture-based sensitization assay (LCSA) and may be performed within 5 days. The system is composed of human monocytes that differentiate to a kind of dendritic cells by 2-day culturing in the presence of allogenic keratinocytes. The culture medium is enriched by a cocktail of recombinant cytokines. On day 3, concentration series of probes are added. On day 5, cells are harvested and analyzed for expression range of CD86 as a marker of sensitizing potential and for uptake of the viability stain 7-AAD as a marker of irritative potential. Estimation of the concentration required to cause a half-maximal increase in CD86 expression allowed quantification of sensitizing potential, and estimation of the concentration required to reduce viability to 50% allowed quantification of irritative potential. Examination of substances with known potential resulted in categorization of test scores. To evaluate our data, we have compared results with those of the validated animal-based sensitization test, the murine local lymph node assay (LLNA, OECD TG 429). To a large extent, results from LCSA and from LLNA achieved analogous grouping of allergens into categories like weak-moderate-strong. However, the new assay showed an improved capacity to distinguish sensitizers from non-sensitizers and irritants. In conclusion, the LCSA contains potential to fulfil the requirements of the EU's programme for the safety of chemicals 'Registration, Evaluation, Authorisation and Restriction of chemical substances' (REACH, 2006) to replace animal models.

60 APPLIED LIFE SCIENCES↗

Unexpected gender difference in sensitivity to the acute toxicity of dioxin in mice

The acute toxicity of the ubiquitous environmental contaminant 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) varies widely among species and strains. Previous studies in rats have established that females are approximately 2-fold more sensitive to TCDD lethality than males. However, there is a surprising gap in the literature regarding possible gender-related sensitivity differences in mice. In the present study, by using three substrains of TCDD-sensitive C57BL/6 mice and transgenic mice on this background, we demonstrated that: 1) in contrast to the situation in rats, female mice are the more resistant gender; 2) the magnitude of the divergence between male and female mice depends on the substrain, but can amount to over 10-fold; 3) AH receptor protein expression levels or mutations in the primary structure of this receptor are not involved in the resistance of female mice of a C57BL/6 substrain, despite their acute LD{sub 50} for TCDD being over 5000 μg/kg; 4) transgenic mice that globally express the rat wildtype AH receptor follow the mouse type of gender difference; 5) in gonadectomized mice, ovarian estrogens appear to enhance TCDD resistance, whereas testicular androgens seem to augment TCDD susceptibility; and 6) the gender difference correlates best with the severity of liver damage, which is also reflected in hepatic histopathology and the expression of pro-inflammatory cytokines, especially IL-6. Hence, the two closely related rodent species most often employed in toxicological risk characterization studies, rat and mouse, represent opposite examples of the influence of gender on dioxin sensitivity, further complicating the risk assessment of halogenated aromatic hydrocarbons. -- Highlights: ► In contrast to rats, male mice are more sensitive to TCDD toxicity than female mice. ► The resistance of female C57BL/6Kuo mice matches or exceeds that of male DBA/2 mice. ► The resistance of female C57BL/6Kuo mice is not based on AHR structure or abundance. ► Both androgens and estrogens appear to influence TCDD sensitivity. ► TCDD sensitivity correlates best with the severity of lesions in the liver.

60 APPLIED LIFE SCIENCES↗

An epidermal equivalent assay for identification and ranking potency of contact sensitizers

The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24 h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC{sub 50}) with human and animal data showed a superior correlation with human DSA{sub 05} (μg/cm{sup 2}) data (Spearman r = 0.8500; P value (two-tailed) = 0.0061) compared to LLNA data (Spearman r = 0.5968; P value (two-tailed) = 0.0542). DSA{sub 05} = induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA{sub 05} data (Spearman r = 0.8333; P value (two-tailed) = 0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model. - Highlights: • A potential epidermal equivalent assay to label and classify sensitizers • Il-18 release distinguishes sensitizers from non sensitizers • IL-18 release can rank sensitizer potency • EC50 (chemical concentration causing 50% decrease in cell viability) ranks potency • In vitro: human DSA{sub 05} correlation is better than in vitro: LLNA correlation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow and critical parameters is presented. • The method could provide a useful tool to complement existing chemical assays.

60 APPLIED LIFE SCIENCES↗

Global Sensitivity Analysis Using the Ultra‐Low Resolution Energy Exascale Earth System Model

Abstract For decades, Arctic temperatures have increased twice as fast as average global temperatures. As a first step toward quantifying parametric uncertainty in Arctic climate, we performed a variance‐based global sensitivity analysis (GSA) using a fully coupled, ultra‐low resolution (ULR) configuration of version 1 of the U.S. Department of Energy's Energy Exascale Earth System Model (E3SMv1). Specifically, we quantified the sensitivity of six quantities of interests (QOIs), which characterize changes in Arctic climate over a 75 year period, to uncertainties in nine model parameters spanning the sea ice, atmosphere, and ocean components of E3SMv1. Sensitivity indices for each QOI were computed with a Gaussian process emulator using 139 random realizations of the random parameters and fixed preindustrial forcing. Uncertainties in the atmospheric parameters in the Cloud Layers Unified by Binormals (CLUBB) scheme were found to have the most impact on sea ice status and the larger Arctic climate. Our results demonstrate the importance of conducting sensitivity analyses with fully coupled climate models. The ULR configuration makes such studies computationally feasible today due to its low computational cost. When advances in computational power and modeling algorithms enable the tractable use of higher‐resolution models, our results will provide a baseline that can quantify the impact of model resolution on the accuracy of sensitivity indices. Moreover, the confidence intervals provided by our study, which we used to quantify the impact of the number of model evaluations on the accuracy of sensitivity estimates, have the potential to inform the computational resources needed for future sensitivity studies.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of TiO{sub 2}/ZnO bilayer film towards pH sensitivity prepared by different spin coating deposition process

In this study, titanium dioxide (TiO{sub 2}) and zinc oxide (ZnO) bilayer film for pH sensing application will be presented. TiO{sub 2}/ZnO bilayer film with different speed of spin-coating process was deposited on Indium Tin Oxide (ITO), prepared by sol-gel method. This fabricated bilayer film was used as sensing membrane for Extended Gate Field-Effect Transistor (EGFET) for pH sensing application. Experimental results indicated that the sensor is able to detect the sensitivity towards pH buffer solution. In order to obtained the result, sensitivity measurement was done by using the EGFET setup equipment with constant-current (100 µA) and constant-voltage (0.3 V) biasing interfacing circuit. TiO{sub 2}/ZnO bilayer film which the working electrode, act as the pH-sensitive membrane was connected to a commercial metal-oxide semiconductor FET (MOSFET). This MOSFET then was connected to the interfacing circuit. The sensitivity of the TiO2 thin film towards pH buffer solution was measured by dipping the sensing membrane in pH4, pH7 and pH10 buffer solution. These thin films were characterized by using Field Emission Scanning Electron Microscope (FESEM) to obtain the surface morphology of the composite bilayer films. In addition, I-V measurement was done in order to determine the electrical properties of the bilayer films. According to the result obtained in this experiment, bilayer film that spin at 4000 rpm, gave highest sensitivity which is 52.1 mV/pH. Relating the I-V characteristic of the thin films and sensitivity, the sensing membrane with higher conductivity gave better sensitivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin-torque diode with tunable sensitivity and bandwidth by out-of-plane magnetic field

Spin-torque diodes based on nanosized magnetic tunnel junctions are novel microwave detectors with high sensitivity and wide frequency bandwidth. While previous reports mainly focus on improving the sensitivity, the approaches to extend the bandwidth are limited. This work experimentally demonstrates that through optimizing the orientation of the external magnetic field, wide bandwidth can be achieved while maintaining high sensitivity. The mechanism of the frequency- and sensitivity-tuning is investigated through analyzing the dependence of resonant frequency and DC voltage on the magnitude and the tilt angle of hard-plane magnetic field. The frequency dependence is qualitatively explicated by Kittel's ferromagnetic resonance model. The asymmetric resonant frequency at positive and negative magnetic field is verified by the numerical simulation considering the in-plane anisotropy. The DC voltage dependence is interpreted through evaluating the misalignment angle between the magnetization of the free layer and the reference layer. The tunability of the detector performance by the magnetic field angle is evaluated through characterizing the sensitivity and bandwidth under 3D magnetic field. The frequency bandwidth up to 9.8 GHz or maximum sensitivity up to 154 mV/mW (after impedance mismatch correction) can be achieved by tuning the angle of the applied magnetic field. The results show that the bandwidth and sensitivity can be controlled and adjusted through optimizing the orientation of the magnetic field for various applications and requirements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of resist sensitivity for extreme ultraviolet lithography using an electron beam

It is a challenge to obtain sufficient extreme ultraviolet (EUV) exposure time for fundamental research on developing a new class of high sensitivity resists for extreme ultraviolet lithography (EUVL) because there are few EUV exposure tools that are very expensive. In this paper, we introduce an easy method for predicting EUV resist sensitivity by using conventional electron beam (EB) sources. If the chemical reactions induced by two ionizing sources (EB and EUV) are the same, the required absorbed energies corresponding to each required exposure dose (sensitivity) for the EB and EUV would be almost equivalent. Based on this theory, we calculated the resist sensitivities for the EUV/soft X-ray region. The estimated sensitivities were found to be comparable to the experimentally obtained sensitivities. It was concluded that EB is a very useful exposure tool that accelerates the development of new resists and sensitivity enhancement processes for 13.5 nm EUVL and 6.x nm beyond-EUVL (BEUVL).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A practical approach to the sensitivity analysis for kinetic Monte Carlo simulation of heterogeneous catalysis

Lattice kinetic Monte Carlo simulations have become a vital tool for predictive quality atomistic understanding of complex surface chemical reaction kinetics over a wide range of reaction conditions. In order to expand their practical value in terms of giving guidelines for atomic level design of catalytic systems, it is very desirable to readily evaluate a sensitivity analysis for a given model. The result of such a sensitivity analysis quantitatively expresses the dependency of the turnover frequency, being the main output variable, on the rate constants entering the model. In the past the application of sensitivity analysis, such as Degree of Rate Control, has been hampered by its exuberant computational effort required to accurately sample numerical derivatives of a property that is obtained from a stochastic simulation method. Here in this study we present an efficient and robust three stage approach that is capable of reliably evaluating the sensitivity measures for stiff microkinetic models as we demonstrate using CO oxidation on RuO 2 (110) as a prototypical reaction. In a first step, we utilize the Fisher Information Matrix for filtering out elementary processes which only yield negligible sensitivity. Then we employ an estimator based on linear response theory for calculating the sensitivity measure for non-critical conditions which covers the majority of cases. Finally we adopt a method for sampling coupled finite differences for evaluating the sensitivity measure of lattice based models. This allows efficient evaluation even in critical regions near a second order phase transition that are hitherto difficult to control. The combined approach leads to significant computational savings over straightforward numerical derivatives and should aid in accelerating the nano scale design of heterogeneous catalysts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Second-Order Sensitivity Analysis of Uncollided Particle Contributions to Radiation Detector Responses

This work presents an application of Cacuci’s Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) to the simplified Boltzmann equation that models the transport of uncollided particles through a medium to compute efficiently and exactly all of the first- and second-order derivatives (sensitivities) of a detector’s response with respect to the system’s isotopic number densities, microscopic cross sections, source emission rates, and detector response function. The off-the-shelf PARTISN multigroup discrete ordinates code is employed to solve the equations underlying the 2nd-ASAM. The accuracy of the results produced using PARTISN is verified by using the results of three test configurations: (1) a homogeneous sphere, for which the response is the exactly known total uncollided leakage, (2) a multiregion two-dimensional (r-z) cylinder, and (3) a two-region sphere for which the response is a reaction rate. For the homogeneous sphere, results for the total leakage as well as for the respective first- and second-order sensitivities are in excellent agreement with the exact benchmark values. For the nonanalytic problems, the results obtained by applying the 2nd-ASAM to compute sensitivities are in excellent agreement with central-difference estimates. The efficiency of the 2nd-ASAM is underscored by the fact that, for the cylinder, only 12 adjoint PARTISN computations were required by the 2nd-ASAM to compute all of the benchmark’s 18 first-order sensitivities and 224 second-order sensitivities, in contrast to the 877 PARTISN calculations needed to compute the respective sensitivities using central finite differences, and this number does not include the additional calculations that were required to find appropriate values of the perturbations to use for the central differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A SENSITIVITY AND ARRAY-CONFIGURATION STUDY FOR MEASURING THE POWER SPECTRUM OF 21 cm EMISSION FROM REIONIZATION

Telescopes aiming to measure 21 cm emission from the Epoch of Reionization must toe a careful line, balancing the need for raw sensitivity against the stringent calibration requirements for removing bright foregrounds. It is unclear what the optimal design is for achieving both of these goals. Via a pedagogical derivation of an interferometer's response to the power spectrum of 21 cm reionization fluctuations, we show that even under optimistic scenarios first-generation arrays will yield low-signal-to-noise detections, and that different compact array configurations can substantially alter sensitivity. We explore the sensitivity gains of array configurations that yield high redundancy in the uv-plane-configurations that have been largely ignored since the advent of self-calibration for high-dynamic-range imaging. We first introduce a mathematical framework to generate optimal minimum-redundancy configurations for imaging. We contrast the sensitivity of such configurations with high-redundancy configurations, finding that high-redundancy configurations can improve power-spectrum sensitivity by more than an order of magnitude. We explore how high-redundancy array configurations can be tuned to various angular scales, enabling array sensitivity to be directed away from regions of the uv-plane (such as the origin) where foregrounds are brighter and instrumental systematics are more problematic. We demonstrate that a 132 antenna deployment of the Precision Array for Probing the Epoch of Reionization observing for 120 days in a high-redundancy configuration will, under ideal conditions, have the requisite sensitivity to detect the power spectrum of the 21 cm signal from reionization at a 3{sigma} level at k < 0.25 h Mpc{sup -1} in a bin of {Delta}ln k = 1. We discuss the tradeoffs of low- versus high-redundancy configurations.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of transitions in internal rotor molecules to a possible variation of the proton-to-electron mass ratio

Recently, methanol was identified as a sensitive target system to probe variations of the proton-to-electron mass ratio {mu}[Jansen et al., Phys. Rev. Lett. 106, 100801 (2011)]. The high sensitivity of methanol originates from the interplay between overall rotation and hindered internal rotation of the molecule; that is, transitions that convert internal rotation energy into overall rotation energy, or vice versa, have an enhanced sensitivity coefficient, K{sub {mu}}. As internal rotation is a common phenomenon in polyatomic molecules, it is likely that other molecules display similar or even larger effects. In this paper we generalize the concepts that form the foundation of the high sensitivity in methanol and use this to construct an approximate model which makes it possible to estimate the sensitivities of transitions in internal rotor molecules with C{sub 3v} symmetry, without performing a full calculation of energy levels. We find that a reliable estimate of transition sensitivities can be obtained from the three rotational constants (A, B, and C) and three torsional constants (F, V{sub 3}, and {rho}). This model is verified by comparing obtained sensitivities for methanol, acetaldehyde, acetamide, methyl formate, and acetic acid with a full analysis of the molecular Hamiltonian. Of the molecules considered, methanol is by far the most suitable candidate for laboratory and cosmological tests searching for a possible variation of {mu}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fluorescence Based Characterization of Calcium Sensitizer Action on the Troponin Complex

By examining the behavior of each Ca2+ -sensitizer on cTnC at different levels of reconstitution (cTnI-cTnC, full troponin, or full troponin in thin filament) the importance of these proteins on sensitizer efficacy was evaluated, lending insight into the mechanism of action behind each drug. A fluorescence based approach was used to monitor the opening and closing of cardiac troponin C's hydrophobic pocket in the presence and absence of four common Ca2+ -sensitizers: EMD 57033, levosimendan, bepridil and pimobendan. Ca2+ -titration experiments were employed to determine the effect on Ca2+- sensitivity and cooperativity of cTnC opening, while stopped flow experiments were used to investigate the impact on cTnC relaxation kinetics. This study shows EMD 57033 is unable to sensitize cTnC to Ca2+, and likely requires the presence of myosin to illicit a response. Levosimendan, bepridil, and pimobendan were all able to increase the sensitivity of cTnC for Ca2+ to varying degrees; levosimendan and pimobendan reduced the rate of cTnC closing, while bepridil increased this rate. Additionally the same experiments were run on thin filament samples containing cTnT (T204E), a known Ca2+- blunting phosphorylation mimic. Levosimendan, bepridil, and pimobendan were found to elevate the Ca2+-sensitivity of cTnT(T204E) containing thin filaments to within range of the wild type thin filaments.

Bepridil↗

TU-A-9A-07: X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption

Purpose: To assess whether X-ray acoustic computed tomography (XACT) is more sensitive to X-ray absorption than that of the conventional X-ray imaging. Methods: First, a theoretical model was built to analyze the X-ray absorption sensitivity of XACT imaging and conventional X-ray imaging. Second, an XACT imaging system was developed to evaluate the X-ray induced acoustic signal generation as well as the sensitivity improvement over transmission x-ray imaging. Ultra-short x-ray pulses (60-nanosecond) were generated from an X-ray source operated at the energy of 150 kVp with a 10-Hz repetition rate. The X-ray pulse was synchronized with the acoustic detection via a x-ray scintillation triggering to acquire the X-ray induced acoustic signal. Results: Theoretical analysis shows that X-ray induced acoustic signal is sensitive only to the X-ray absorption, while completely insensitive to out the X-ray scattering and fluorescence. XACT has reduced background and increased contrast-to-noise ratio, and therefore has increased sensitivity compared to transmission x-ray imaging. For a 50-μm size, gadolinium insertion in tissue exposed to 40 keV X-rays; the sensitivity of XACT imaging is about 28.9 times higher than that of conventional X-ray imaging. Conclusion: X-ray acoustic computer tomography (XACT) as a new imaging modality combines X-ray absorption contrast and high ultrasonic resolution in a single modality. It is feasible to improve the imaging sensitivity with XACT imaging compared with conventional X-ray imaging. Taking advantage of the high ultrasonic resolution, it is possible to perform 3-D imaging with a single x-ray pulse with arrays of transducers without any mechanical motion of the imaging system. This single-shot capability offers the potential of reducing radiation dose by a factor of 1000, and imaging 100 times faster when compared to the conventional X-ray CT, and thus revolutionizing x-ray imaging applications in medicine and biology. The authors gratefully acknowledge the Department of Defense Prostate Cancer Research Programs W81XWH-13-1-0481 (LX), the National Institutes of Health 1R01 CA133474 and 1R21 A153587, and SRFDP (20124407120012) for funding.

60 APPLIED LIFE SCIENCES↗

Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA

Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner. Presage dosimeter in this form was sensitive enough for use in SRS and SBRT QA. The lower gamma pass rate for Presage compared to Gafchromic film can be attributed to the simple equipment used in the fabrication process, which limited the dosimeter’s sensitivity uniformity by agglomeration of air bubbles in the material, nonuniform concentration of chemicals throughout the material, and thickness variations. This demands improvements in mixing tools and molds.

60 APPLIED LIFE SCIENCES↗