Scanning tunneling microscopy of ferrocenecarboxylic acid assemblies on Ag(111): a comparison to Au(111)

Scanning tunneling microscopy was used to investigate the arrangement of ferrocenecarboxylic acid (FcCOOH) monolayers on the Ag(111) surface. Four distinct structures were observed, none of which had previously been observed on other surfaces. Structural analysis indicates that these assemblies are primarily composed of dimers. VASP calculations support the molecular assignments of the monolayer structures, while ESI-MS experiments confirm that dimers are the predominant species in solution. Of particular note, the cyclic pentamers and aperiodic packing observed for FcCOOH on Au(111) were not observed, despite (1) the similarity of the Ag(111) and Au(111) surfaces in reactivity, flatness, and lattice constant, and (2) prior explanation of the Au(111) monolayer in terms of molecule–molecule interactions alone. It is clear that while the surface does not have a template structure, it has a significant influence on which structures are formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE↗

Unveiling Structural Heterogeneity and Imbalance of Gold Decahedral Nanoparticles using Four-dimensional Scanning Transmission Electron Microscopy

Multi-twinned structures have been observed in technologically important crystal systems, for example diamond cubic and face-centered cubic (FCC) lattices, that include materials such as diamond, silicon, a wide range of noble metals, and their nanoscale counterparts. Beyond atomic building blocks, the special arrangements also occur in the self-assembly of nanoparticles (NP) and μm-sized colloidal particles and occupy parts of their phase diagrams. Spanning a wide range of length scales, the universality of the structures arises when the systems attempt to achieve multitwinned structures by overcoming geometric misfits during minimizing surface energies with entirely {111} or close-packing facets. While it is fundamental to understand how strain is sustained upon twinned structures and symmetry breaking, the knowledge will be paramount in practical aspects such as guiding and controlling the thin film growth, anisotropic NP growth, and self-assembly of NPs. Au decahedral (Dh) NP, as the most prevalent multi-twinned model system, fits five tetrahedral motifs into a circle by sharing an axis resulting in a geometric misfit angle of 7.35°, or a disclination with power of -7.35°. Postulating how Au FCC lattice adopts the misfit, theoretical models have been developed to address the underlying lattice symmetry and inhomogeneous strain distribution separately. Yet, experimental reports regarding the former have been limited due to the relatively large X-ray beam sizes that do not fit the sizes of NPs. On the other hand, though the latter has been widely adapted in the thermodynamics of small (<10 nm) multi-twinned nanoparticles, previous literature has shown that, at edge length of 17 nm, the theory’s is invalidated by shear strain that is observed in a defect-free Au Dh NP by high-resolution transmission electron microscopy (HR-TEM) imaging. Though the advancement of aberrationcorrected scanning transmission electron microscopy (AC-STEM) imaging and ab initio calculation techniques brings new opportunities, along with challenges in complicated image analysis and limitation in particle size (usually below 10 nm), the gap between nanoscale and mesoscale has never been extended to gain insight from atomic system with straightforward interaction potentials.

4D-STEM↗

Reconstruction of the interatomic forces from dynamic scanning transmission electron microscopy data

We explore the possibility for reconstruction of the generative physical models describing interactions between atomic units in solids from observational electron microscopy data. In this work, scanning transmission electron microscopy (STEM) is used to observe the dynamic motion of Si atoms at the edge of monolayer graphene under continuous electron beam illumination. The resulting time-lapsed STEM images represent the snapshots of observed chemical states of the system. We use two approaches: potential of mean force calculation using a radial distribution function and a direct fitting of the graphene–Si interatomic pairwise potentials with force matching, to reconstruct the force fields in the materials. These studies lay the foundation for quantitative analysis of materials energetics from STEM data through the sampling of the metastable states in the chemical space of the system.

42 ENGINEERING↗

Investigating the effect of electric fields on lead halide perovskites by scanning tunneling microscopy

Lead halide perovskites have emerged as promising absorber materials over the last decade to increase the efficiency of photovoltaics beyond its current limits. However, to further optimize the performance of perovskites, more detailed studies need to be performed which allow for the correlation of film morphology and local electronic properties at the nanoscale. In this paper, we present a scanning tunneling microscopy (STM) approach to probe the effect of an applied electric field of a methylammonium formamidinium lead triiodide perovskite thin film on the film response by current-voltage spectroscopy, current imaging tunneling spectroscopy, differential conductance mapping and X-ray absorption spectroscopy (XAS) by means of synchrotron X-ray STM (SX-STM). We find a strong correlation between the measurement conditions and the obtained current-voltage characteristics when imaging under opposite applied bias polarities. In particular, we find similarities to already observed poling effects for perovskites which result in either a positively or negatively charged interface due to ion and vacancy migration. Our results provide insight into the influence of measurement conditions such as bias polarity on the performance assessment of perovskite thin films by STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AI-enabled high-resolution scanning coherent diffraction imaging

Ptychographic imaging is a powerful means of imaging beyond the resolution limits of typical x-ray optics. Capturing recovered images from raw ptychographic data, however, requires the solution of an inverse problem, namely, phase retrieval. Phase retrieval algorithms are computationally expensive, which precludes real-time imaging. In this work, we propose PtychoNN, an approach to solve the ptychography data inversion problem based on a deep convolutional neural network. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. Our results demonstrate the practical application of machine learning to recover high fidelity amplitude and phase contrast images of a real sample hundreds of times faster than current ptychography reconstruction packages. Furthermore, by overcoming the constraints of iterative model-based methods, we can significantly relax sampling constraints on data acquisition while still producing an excellent image of the sample. Besides drastically accelerating acquisition and analysis, this capability has profound implications for the imaging of dose sensitive, dynamic, and extremely voluminous samples.

47 OTHER INSTRUMENTATION↗

Effect of sample anisotropy on scanning near-field optical microscope images

Scattering-type scanning near-field optical microscopy (s-SNOM) has been widely used to characterize strongly correlated electronic, two dimensional, and plasmonic materials, and it has enormous potential for biological applications. Many of these materials exhibit anisotropic responses that complicate the extraction of dielectric constants from s-SNOM measurements. Here, we generalize our recently developed approach for retrieving the near-field scattering signal from isotropic systems and apply it to anisotropic dielectrics. Specifically, we compare our theoretical results with experimental measurements on modestly anisotropic sapphire that exhibit strong resonances at the infrared frequency range. Good agreement with the experimental result is found. Finally, our result is important for understanding the near-field response of low damping, anisotropic polaritonic states in dielectric media.

36 MATERIALS SCIENCE↗

r 2 SCAN-D4: Dispersion corrected meta-generalized gradient approximation for general chemical applications

We combine a regularized variant of the strongly constrained and appropriately normed semilocal density functional with the latest generation semi-classical London dispersion correction. The resulting density functional approximation r 2 SCAN-D4 has the speed of generalized gradient approximations while approaching the accuracy of hybrid functionals for general chemical applications. We demonstrate its numerical robustness in real-life settings and benchmark molecular geometries, general main group and organo-metallic thermochemistry, and non-covalent interactions in supramolecular complexes and molecular crystals. Main group and transition metal bond lengths have errors of just 0.8%, which is competitive with hybrid functionals for main group molecules and outperforms them for transition metal complexes. The weighted mean absolute deviation (WTMAD2) on the large GMTKN55 database of chemical properties is exceptionally small at 7.5 kcal/mol. This also holds for metal organic reactions with an MAD of 3.3 kcal/mol. The versatile applicability to organic and metal–organic systems transfers to condensed systems, where lattice energies of molecular crystals are within the chemical accuracy (errors <1 kcal/mol).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying the temperature of heated microdevices using scanning thermal probes

Quantifying the temperature of microdevices is critical for probing nanoscale energy transport. Such quantification is often accomplished by integrating resistance thermometers into microdevices. However, such thermometers frequently become structurally unstable and fail due to thermal stresses at elevated temperatures. Here, we show that custom-fabricated scanning thermal probes (STPs) with a sharp tip and an integrated heater/thermometer can accurately measure the temperature of microdevices held at elevated temperatures. This measurement is accomplished by introducing a modulated heat input to the STP after contacting the microdevice with the STP's tip and characterizing the DC and AC components of the STP's temperature. From these measured temperature components, the tip-to-sample thermal resistance and the microdevice surface temperature are deduced simultaneously via a simple lumped-capacitance model. The advances presented here can greatly facilitate temperature measurements of a variety of heated microdevices.

42 ENGINEERING↗

Scanning tunneling microscopy and spectroscopy characterization of Nb films for quantum applications

Niobium thin films are key components of superconducting microwave resonators. Interest in these devices has increased dramatically because of their application in quantum systems. Despite tremendous effort to improve their performance, loss mechanisms are still not well understood. Nb/substrate and Nb/air interfaces are likely culprits in contributing to decoherence and ultimately limiting the performance of superconducting devices. Here, we investigate the Nb/substrate interface by studying the effect of hydrogen-passivated H:Si(111) substrates on the local superconducting properties of ∼40 nm thick Nb films compared to Nb films grown on typical Si(001) substrates. Specifically, low-temperature scanning tunneling microscopy and spectroscopy are employed to compare nanoscale material properties. Further, the atomically flat monohydride H:Si(111) substrates are found to yield a smoother and less defective interface with the Nb film. Correspondingly, the Nb films grown on H:Si(111) substrates present more uniform superconducting properties and exhibit less quasiparticle broadening.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Blockage and speedup in the proximity of an onshore wind farm: A scanning wind LiDAR experiment

To maximize the profitability of wind power plants, wind farms are often characterized by high wind turbine density leading to operations with reduced turbine spacing. As a consequence, the overall wind farm power capture is hindered by complex flow features associated with flow modifications induced by the various wind turbine rotors. In addition to the generation of wakes, the velocity of the incoming wind field can reduce due to the increased pressure in the proximity of a single turbine rotor (named induction); a similar effect occurs at the wind-farm level (global blockage), which can have a noticeable impact on power production. On the other hand, intra-wind-farm regions featuring increased velocity compared to the freestream (speedups) have also been observed, which can be a source for a potential power boost. To quantify these rotor-induced effects on the incoming wind velocity field, three profiling LiDARs and one scanning wind LiDAR were deployed both before and after the construction of an onshore wind turbine array. The different wind conditions are classified according to the ambient turbulence intensity and streamwise/spanwise spacing among wind turbines. The analysis of the mean velocity field reveals enhanced induction and speedup under stably stratified atmospheric conditions. Additionally, a reduced horizontal area between adjacent turbines has a small impact on the induction zone but increases significantly the speedup between adjacent rotors.

17 WIND ENERGY↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Quantification and assessment of the atmospheric boundary layer height measured during the AWAKEN experiment by a scanning LiDAR

The atmospheric boundary layer (ABL) height plays a key role in many atmospheric processes as one of the dominant flow length scales. However, a systematic quantification of the ABL height over the entire range of scales (i.e., with periods ranging from one minute to one year) is still lacking in literature. In this work, the ABL height is quantified based on high-resolution measurements collected by a scanning pulsed Doppler LiDAR during the recent American WAKE experimeNt (AWAKEN) campaign. The high availability of ABL height estimates (≈2200 collected over one year and each of them based on 10-min averaged statistics) allows to robustly assess five different ABL height models, i.e., one for convective thermal conditions and four for stable conditions. Thermal condition is quantified by a stability parameter spanning three orders of magnitude and probed by near-ground 3D sonic anemometry. The free-atmosphere stability, quantified by the Brunt–Väisälä frequency, is both calculated from simultaneous radiosonde measurements and obtained from the best fit of two of the chosen ABL height models. Good agreement is found between the data and three of the chosen models, quantified by mean absolute errors on the ABL height between 281 and 585 m. Furthermore, the seasonal variability of the convective ABL height model parameters (−15% to +23% with respect to the year baseline) agrees with the variability of buoyancy-generated turbulence caused by the variation in solar radiation throughout the year.

17 WIND ENERGY↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Fabrication of pristine 2D heterostructures for scanning probe microscopy

Material-by-design has been a long-standing aspiration that has recently become a reality. Such designer materials have been repeatedly demonstrated using the top-down approach of mechanical exfoliation and stacking, leading to a variety of artificial 2D heterostructures with new properties that are otherwise unattainable. Consequently, tremendous research frontiers in physics, chemistry, engineering, and life science have been created. While thousands of layered crystals exist in nature, only a few dozen of them with manageable chemical-stability have been made into heterostructures using this method. Moreover, experimental investigations of materials that have received limited exploration in the 2D realm, such as cuprates, halides, and perovskites, along with their heterostructures, have been fundamentally hindered by their rapid chemical degradation. Another critical challenge imposed by exfoliating and stacking 2D layers in ambient environment is the absorption of itinerant gas molecules that further contaminate sensitive 2D interfaces in the heterostructures. Such contamination and compromised material properties significantly hinder surface-sensitive local probes—scanning probe microscopy (SPM)—that often require nanometer to atomic scale surface cleanliness. In this article, we aim to provide a technical review of recent development toward 2D materials and heterostructure fabrication in more controlled environments that are suitable for SPM characterizations. These include the development of more efficient mechanical exfoliation and dry-transfer techniques, as well as the incorporation of 2D material exfoliation and transfer in inert gas, low vacuum, and, eventually, ultra-high vacuum environments. Finally, we provide an outlook on the remaining challenges and opportunities in ultra-clean 2D material fabrication techniques.

Materials Science↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Isoplethal study of phase formation and morphology in uranium-304L steel via scanning electron microscopy

Understanding the formation of uranium alloys with steel is important to advance nuclear technologies involving U metal fuels and machining U metal, and for nuclear forensics applications. No known phase diagram for the quaternary U-(M = Fe, Ni, Cr) system exists. For this work, we synthesize samples of U-304 L steel (nominal composition 70.1:18.3:10.4 at% Fe:Cr:Ni) across the U composition range 4.45—63.35 at%U by arc melting under inert conditions. Using the binary UFe phase diagram as a reference, we identify four U-steel alloy phases. We find the known U-Fe analogue phases UM 2 and U 6 M, and two low-U composition phases with nominal compositions UM 10 and U 2 M 7 . We apply a correlation length analysis to backscatter scanning electron microscopy images of sectioned and polished cross sections to quantify the domain formation length scale. We demonstrate that these depend heavily on the initial composition and range from 30 nm to 1.5 µm. This result, in particular, could be applicable to theoretical predictions of transport properties. Furthering our understanding of U alloy phase formation with important structural elements such as steel primaries is foundational in developing future nuclear technology.

36 MATERIALS SCIENCE↗

Quantitative phase retrieval and characterization of magnetic nanostructures via Lorentz (scanning) transmission electron microscopy

Magnetic materials phase reconstruction using Lorentz transmission electron microscopy (LTEM) measurements have traditionally been achieved using longstanding methods such as off-axis holography (OAH) fast-Fourier transform technique and the transport-of-intensity equation (TIE). The increase in access to processing power alongside the development of advanced algorithms have allowed for phase retrieval of nanoscale magnetic materials with greater efficacy and resolution. Specifically, reverse-mode automatic differentiation (RMAD) and the extended electron ptychography iterative engine (ePIE) are two recent developments of phase retrieval that can be applied to analyzing micro-to-nano- scale magnetic materials. This work evaluates phase retrieval using TIE, RMAD, and ePIE in simulations of Permalloy (Ni 80 Fe 20 ) nanoscale islands, or nanomagnets. Extending beyond simulations, we demonstrate total phase retrieval and image reconstructions of a NiFe nanowire using OAH and RMAD in LTEM and ePIE in Lorentz-mode-4D scanning transmission electron microscopy experiments and determine the saturation magnetization through corroborations with micromagnetic modeling. Finally, we demonstrate the efficacy of these methods in retrieving the total phase and highlight its use in characterizing and analyzing the proximity effect of the magnetic nanostructures.

Lorentz transmission electron microscopy↗