Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

International Research Reactor Decommissioning Project

Many research reactors have been or will be shut down and are candidates for decommissioning. Most of the respective countries neither have a decommissioning policy nor the required expertise and funds to effectively implement a decommissioning project. The IAEA established the Research Reactor Decommissioning Demonstration Project (R{sup 2}D{sup 2}P) to help answer this need. It was agreed to involve the Philippine Research Reactor (PRR-1) as model reactor to demonstrate 'hands-on' experience as it is just starting the decommissioning process. Other facilities may be included in the project as they fit into the scope of R{sup 2}D{sup 2}P and complement to the PRR-1 decommissioning activities. The key outcome of the R{sup 2}D{sup 2}P will be the decommissioning of the PRR-1 reactor. On the way to this final goal the preparation of safety related documents (i.e., decommissioning plan, environmental impact assessment, safety analysis report, health and safety plan, cost estimate, etc.) and the licensing process as well as the actual dismantling activities could provide a model to other countries involved in the project. It is expected that the R{sup 2}D{sup 2}P would initiate activities related to planning and funding of decommissioning activities in the participating countries if that has not yet been done.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗

Verification of maximum radial power peaking factor due to insertion of FPM-LEU target in the core of RSG-GAS reactor

Verification of Maximum Radial Power Peaking Factor due to insertion of FPM-LEU target in the core of RSG-GAS Reactor. Radial Power Peaking Factor in RSG-GAS Reactor is a very important parameter for the safety of RSG-GAS reactor during operation. Data of radial power peaking factor due to the insertion of Fission Product Molybdenum with Low Enriched Uranium (FPM-LEU) was reported by PRSG to BAPETEN through the Safety Analysis Report RSG-GAS for FPM-LEU target irradiation. In order to support the evaluation of the Safety Analysis Report incorporated in the submission, the assessment unit of BAPETEN is carrying out independent assessment in order to verify safety related parameters in the SAR including neutronic aspect. The work includes verification to the maximum radial power peaking factor change due to the insertion of FPM-LEU target in RSG-GAS Reactor by computational method using MCNP5and ORIGEN2. From the results of calculations, the new maximum value of the radial power peaking factor due to the insertion of FPM-LEU target is 1.27. The results of calculations in this study showed a smaller value than 1.4 the limit allowed in the SAR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Twenty years of dry interim storage of spent nuclear fuel (SNF) in Germany- History and developments - 15575

According to article 6 of the German Atomic Energy Act, storage of nuclear fuel requires a license granted by the competent authority in this field, which is the Federal Office of Radiation Protection. In 1983 a license to store spent nuclear fuel (SNF) and later expanded for vitrified high level waste (HAW) for the interim storage facility in Gorleben was granted. Dry Interim storage at the NPP sites in its actual form started in 2002 in the interim storage facility next to the NPP Lingen. Since this time each NPP erected its own storage facility and three central storage facilities have been built. All of these facilities use dry storage in metallic casks. The actual storage licenses for SNF and the HAW (which is stored in Gorleben and Rubenow) are limited to 40 years starting with the first cask emplacement. As no opening of the cask is intended during the storage period the condition of the inventory and the cask before loading has to be known in detail. This requires for instance detailed knowledge of the history of the SNF loaded as well as supervision of the manufacturing process of the cask. Within the last twenty years several mishaps influenced the regulatory point of view. During a loading campaign in a boiling water reactor traces of pool water remained in the gasket slot and during the drying procedure crystalline boron salts prevented the required tightness. After that event a long-term experiment was started and is still going on which studies the effects of water and minor damages to the gasket. As well changes in the loading procedure have been introduced. The pressure switch used to monitor the pressure in the space between primary and secondary lid has a self surveillance function. This indicated a malfunction 23 times in the last twenty years. Examinations of all events indicated no systematic failure, but a weak point seems to be the plug-in connection. The manufacturer introduced some modifications to improve the system. Introduction of FEM methods in safety analysis to amend the existing methods of testing allowed a new view on and in the cask safety analysis. Progress in this field is closely connected to the available computing capacity and stipulates experts to ongoing improvement. After expiring of the storage license which will be the case for the first cask loaded in 1992 and stored in Ahaus 2032 an extension or a new license can only be granted if the at this time relevant requirements are met. This will require detailed knowledge about the happenings and accidents during the previous storage period. All experience of the periodic safety assessment (PSA) which started in 2013 and accompanying experiments conducted till now and during the licensed storage time will be needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Content Addition and Testing for 2017 NRC Amendment for the Versa-Pac Type A Fissile Packaging - 18120

The Versa-Pac is a certified Type A, fissile packaging (USA NRC Certificate no. USA/9342/AF-96), often used as a waste package for one time use. Continuous content additions have improved the versatility of the package resulting in expanded uses for the nuclear industry. Principal design of the Versa-Pac packaging maintains the use of an inner liner positioned inside a 55-gallon (VP-55) or 110-gallon drum (VP-110), as used for decades in the transport and disposal of Type A fissile materials. The Versa-Pac is used directly or in conjunction with pails, pipe containers, poly bottles, and a variety of smaller containers, inserts and vessels. The Versa-Pac content developments assist the industry with site shutdown, decommissioning, and cleanup operations, allowing for removal, transport, and storage options for the residual waste materials. A 2017 NRC license amendment application adds new capabilities to the Versa-Pac that include a low 1.25 wt% {sup 235}U enriched uranium loading, small quantities of UF{sub 6} in the form of 1S and 2S cylinders, and a payload mass increase from 250 to 350 pounds for the Versa-Pac 55-gallon version (VP-55). The lower uranium enrichment loading of 1.25 wt% {sup 235}U allows for a higher uranium mass limit. The inclusion of 1S and 2S UF{sub 6} cylinders fills an industry need to remove and dispose of long-stored material during site cleanup activities. The content payload mass limit is increased for low contaminated or radioactive heavy metal contents, such as cut plant components and ingots. Regulatory certification of new contents is demonstrated by test, analysis, and a combination of these techniques to show that the design function of the Versa-Pac as a Type A fissile package remains unchanged. Specific UF{sub 6} criticality and thermal analysis upgrades are added to the design documentation to accommodate 1S and 2S UF{sub 6} cylinders. The parameters for criticality analyses are simplified, ensuring no credit for cylinder containment is required for HAC thus reducing the reliance on a single specific shoring device. An upgrade of the Versa-Pac thermal analysis demonstrates compliance with ANSI N14.1 UF{sub 6} cylinder thermal limits. A new drop test sequence for the VP-55 was performed, documenting the addition of the 350-pound payload and demonstrating the VP-55 maintains structural integrity during the NCT and HAC drop, crush and puncture events as defined by 10 CFR 71. The testing and analyses show no loss of the material occurs and the package maintains the material in a subcritical state. This paper traces the engineering and licensing efforts involved in expanding the Versa-Pac's versatility for the 2017 NRC amendment application; summarizing the new testing and results for the payload increase, the content addition criticality and thermal evaluations, and content description for the Versa-Pac Safety Analysis Report. The NRC license amendment is scheduled for Winter 2017. Testing and supporting analyses reported in the Versa-Pac Safety Analysis Report demonstrates the content developments met the performance requirements of 10 CFR 71 for a Type A fissile package. A revision of the NRC Certificate of Compliance is expected in Spring 2018. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plutonium Equivalent Inventory for Belowground Radioactive Waste at the Los Alamos National Laboratory Technical Area 54, Area G Disposal Facility - Fiscal Year 2011

The Los Alamos National Laboratory (LANL) generates radioactive waste as a result of various activities. Many aspects of the management of this waste are conducted at Technical Area 54 (TA-54); Area G plays a key role in these management activities as the Laboratory's only disposal facility for low-level radioactive waste (LLW). Furthermore, Area G serves as a staging area for transuranic (TRU) waste that will be shipped to the Waste Isolation Pilot Plant for disposal. A portion of this TRU waste is retrievably stored in pits, trenches, and shafts. The radioactive waste disposed of or stored at Area G poses potential short- and long-term risks to workers at the disposal facility and to members of the public. These risks are directly proportional to the radionuclide inventories in the waste. The Area G performance assessment and composite analysis (LANL, 2008a) project long-term risks to members of the public; short-term risks to workers and members of the public, such as those posed by accidents, are addressed by the Area G Documented Safety Analysis (LANL, 2011a). The Documented Safety Analysis uses an inventory expressed in terms of plutonium-equivalent curies, referred to as the PE-Ci inventory, to estimate these risks. The Technical Safety Requirements for Technical Area 54, Area G (LANL, 2011b) establishes a belowground radioactive material limit that ensures the cumulative projected inventory authorized for the Area G site is not exceeded. The total belowground radioactive waste inventory limit established for Area G is 110,000 PE-Ci. The PE-Ci inventory is updated annually; this report presents the inventory prepared for 2011. The approach used to estimate the inventory is described in Section 2. The results of the analysis are presented in Section 3.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upgrading the HFIR Thermal-Hydraulic Legacy Code Using COMSOL

Modernization of the High Flux Isotope Reactor (HFIR) thermal-hydraulic (TH) design and safety analysis capability is an important step in preparation for the conversion of the HFIR core from a high enriched uranium (HEU) fuel to a low enriched uranium (LEU) fuel. Currently, an important part of the HFIR TH analysis is based on the legacy Steady State Heat Transfer Code (SSHTC), which adds much conservatism to the safety analysis. The multi-dimensional multi-physics capabilities of the COMSOL environment allow the analyst to relax the number and magnitude of conservatisms, imposed by the SSHTC, to present a more physical model of the TH aspect of the HFIR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Portable Wireless LAN Device and Two-Way Radio Threat Assessment for Aircraft VHF Communication Radio Band

This document summarizes the safety analysis performed on a Flight Guidance System (FGS) requirements model. In particular, the safety properties desired of the FGS model are identified and the presence of the safety properties in the model is formally verified. Chapter 1 provides an introduction to the entire project, while Chapter 2 gives a brief overview of the problem domain, the nature of accidents, model based development, and the four-variable model. Chapter 3 outlines the approach. Chapter 4 presents the results of the traditional safety analysis techniques and illustrates how the hazardous conditions associated with the system trace into specific safety properties. Chapter 5 presents the results of the formal methods analysis technique model checking that was used to verify the presence of the safety properties in the requirements model. Finally, Chapter 6 summarizes the main conclusions of the study, first and foremost that model checking is a very effective verification technique to use on discrete models with reasonable state spaces. Additional supporting details are provided in the appendices.

Nguyen, Truong X.↗

Preliminary core design studies for the advanced burner reactor over a wide range of conversion ratios.

A consistent set of designs for 1000 MWt commercial-scale sodium-cooled Advance Burner Reactors (ABR) have been developed for both metal and oxide-fueled cores with conversion ratios from breakeven (CR=1.0) to fertile-free (CR=0.0). These designs are expected to satisfy thermal and irradiation damage limits based on the currently available data. The very low conversion ratio designs require fuel that is beyond the current fuel database, which is anticipated to be qualified by and for the Advanced Burned Test Reactor. Safety and kinetic parameters were calculated, but a safety analysis was not performed. Development of these designs was required to achieve the primary goal of this study, which was to generate representative fuel cycle mass flows for system studies of ABRs as part of the Global Nuclear Energy Partnership (GNEP). There are slight variations with conversion ratio but the basic ABR configuration consists of 144 fuel assemblies and between 9 and 22 primary control assemblies for both the metal and oxide-fueled cores. Preliminary design studies indicated that it is feasible to design the ABR to accommodate a wide range of conversion ratio by employing different assembly designs and including sufficient control assemblies to accommodate the large reactivity swing at low conversion ratios. The assemblies are designed to fit within the same geometry, but the size and number of fuel pins within each assembly are significantly different in order to achieve the target conversion ratio while still satisfying thermal limits. Current irradiation experience would allow for a conversion ratio of somewhat below 0.75. The fuel qualification for the first ABR should expand this experience to allow for much lower conversion ratios and higher bunrups. The current designs were based on assumptions about the performance of high and very high enrichment fuel, which results in significant uncertainty about the details of the designs. However, the basic fuel cycle performance trends such as conversion ratio and mass flow parameters are less sensitive to these parameters and the current results should provide a good basis for static and dynamic system analysis. The conversion ratio is fundamentally a ratio of the macroscopic cross section of U-238 capture to that of TRU fission. Since the microscopic cross sections only change moderately with fuel design and isotopic concentration for the fast reactor, a specific conversion ratio requires a specific enrichment. The approximate average charge enrichment (TRU/HM) is 14%, 21%, 33%, 56%, and 100% for conversion ratios of 1.0, 0.75, 0.50, 0.25, and 0.0 for the metal-fueled cores. The approximate average charge enrichment is 17%, 25%, 38%, 60%, and 100% for conversion ratios of 1.0, 0.75, 0.50, 0.25, and 0.0 for the oxide-fueled core. For the split batch cores, the maximum enrichment will be somewhat higher. For both the metal and oxide-fueled cores, the reactivity feedback coefficients and kinetics parameters seem reasonable. The maximum single control assembly reactivity faults may be too large for the low conversion ratio designs. The average reactivity of the primary control assemblies was increased, which may cause the maximum reactivity of the central control assembly to be excessive. The values of the reactivity coefficients and kinetics parameters show that some values appear to improve significantly at lower conversion ratios while others appear far less favorable. Detailed safety analysis is required to determine if these designs have adequate safety margins or if appropriate design modifications are required. Detailed system analysis data has been generated for both metal and oxide-fueled core designs over the entire range of potential burner reactors. Additional data has been calculated for a few alternative fuel cycles. The systems data has been summarized in this report and the detailed data will be provided to the systems analysis team so that static and dynamic system analyses can be performed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP-7 Pressurizer Component Development Updates

RELAP-7 is a nuclear systems safety analysis code being developed at the Idaho National Laboratory (INL). RELAP-7 development began in 2011 to support the Risk Informed Safety Margins Characterization (RISMC) Pathway of the Light Water Reactor Sustainability (LWRS) program. The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical methods, and physical models in order to provide capabilities needed for the RISMC methodology and to support nuclear power safety analysis. The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). The initial development goal of the RELAP-7 approach focused primarily on the development of an implicit algorithm capable of strong (nonlinear) coupling of the dependent hydrodynamic variables contained in the 1-D/2-D flow models with the various 0-D system reactor components that compose various boiling water reactor (BWR) and pressurized water reactor nuclear power plants (NPPs). As part of the efforts to expand the capability for PWR simulation, an equilibrium single-region pressurizer model has been implemented in RELAP-7. The pressurizer component can simulate pressure and water level change through insurge, spray, and heating processes. Two simple tests – one for insurge process and another for outsurge process – have been reported to demonstrate and verify the functions of the pressurizer model. The typical single-phase PWR system model presented in the first RELAP-7 milestone report has been updated, as part of system level test for the new pressurizer model. The updated PWR system model with the pressurizer component can be used for more realistic transient simulations. The addition of the equilibrium single-region pressurizer model represents the first step of developing a suite of pressurizer models with different levels of fidelities. Non-equilibrium two-region two-zone model and non-equilibrium five-region three zone model will be implemented in the near future. Cross comparison and validation will be pursued when higher fidelity pressurizer models are completed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Water Ingress Effects on the Reactivity Change of the Conceptual Designed Reactor at NIST

The conceptual research reactor design with a split core for a replacement reactor project at the NIST (National Institute of Standards and Technology) Center for Neutron Research is underway. The reactor core is cooled and moderated by light water and reflected by heavy water in a reflector tank. The reactor core is immersed in light water, which is isolated from heavy water with a slightly pressurized boundary box made of zirconium alloy. The heavy water is contained in a large size cylindrical tank which also provides ample space to accommodate neutron beam tubes, cold sources and other irradiation equipment. The reflector tank is placed in the center of a large light water pool, which provides thermal and biological shielding to the reactor. Light water and heavy water have distinct physical properties in regard to neutron moderation. Light water is generally known to have greater moderating power and absorption cross-sections, while heavy water has a higher moderating ratio. Due to these differences in properties, the accidental mixing of light water and heavy water in either direction will inevitably affect the reactivity of the reactor. Moreover, since the neutron flux spectrum at different locations of the reactor will have significantly different characteristics (for example, the spectrum at the heavy tank should be much softer than that at the core center region), the effect of reactivity changes becomes complicated and will depend on the water mixing locations. From the reactor safety analysis perspective, the water ingress reactivity change is one of the required design base reactivity accidents that must be evaluated in the final safety analysis report. Given these concerns, neutronics calculations have been performed to determine the effect and trend of the reactivity changes due to water ingress in different scenarios by purposely mixing the waters at three representative places in the reactor: the reflector area, the center coolant area and the peripheral coolant area. These three places were selected for the study because of their uniqueness in the flux spectrum (as shown in the results section). Simple static neutronics calculations were performed using MCNP6 to examine the reactivity effects due to water ingress. It should be noted that all calculations performed in this study assume homogeneous water mixing in the area of interest; therefore, the local effect of the mixing situation would possibly be missed by this study. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress on ATF development of SiC for LWR

Since 2011, Toshiba has been participating in a study whose objective is the commercial utilization of SiC instead of Zircaloy as LWR fuel material. During the period (Phase-1) from 2012 to 2015, feasibility studies on material design and fabrication were performed. This paper reports the principal results of a comprehensive feasibility study on SiC involving experiments and trial fabrication in terms of material properties, core and fuel design, and analytical simulation for safety analysis. The principal results are summarized as follows. First, the fabrication trials for the reduced scales of channel box and cladding have been successfully performed. Secondly, with regard to fuel rod performance analysis, hoop stress during normal operation may be a potential issue in fuel mechanical design as it is relatively high. Thirdly, with regard to safety analysis, the hydrogen generation of SiC fuel tends to decrease significantly compared with that of Zircaloy fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solving implicit multi-mesh flow and conjugate heat transfer problems with RELAP-7

The fully implicit simulation capability of RELAP-7 to solve multi-mesh flow and conjugate heat transfer problems for reactor system safety analysis is presented. Compared to general single-mesh simulations, the reactor system safety analysis-type of code has unique challenges due to its highly simplified, interconnected, one-dimensional, and zero-dimensional flow network describing multiple physics with significantly different time and length scales. To use the Jacobian-free Newton Krylov-type of solver, preconditioning is generally required for the Krylov method. The uniqueness of the reactor safety analysis-type of code in treating the interconnected flow network and conjugate heat transfer also introduces challenges in providing preconditioning matrix. Typical flow and conjugate heat transfer problems involved in reactor safety analysis using RELAP-7, as well as the special treatment on the preconditioning matrix are presented in detail. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of the Phenix end-of-life natural convection test with SAS4A/SASSYS-1

From a reduced power and flow condition, the 2009 Phenix Natural Convection Test mimics a protected loss-of-heat sink event. The measured transient response of the Phenix reactor to such an event provides an important data set for validating safety analysis codes. A model of the Phenix reactor and primary coolant system was developed using the reactor safety analysis code system SAS4A/SASSYS-1. While the overall global response of the reactor was predicted reasonably well, there were some non-negligible discrepancies in the temperature predictions during the transient and work continues to improve the model. Some modeling issues have been identified, and will be addressed as improvements to the model continue. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary SAM Assessment

The System Analysis Module (SAM) is a modern system analysis tool being developed at Argonne National Laboratory (Argonne) for advanced non-LWR safety analysis. To assist NRC to assess SAM capabilities for advanced reactor safety analysis and licensing at the NRC, a series of verification and other standard tests (OSTs) are modeled in SAM and code simulation results are compared with available analytical results. This report documents the preliminary SAM assessment using a matrix of six test problems. Each test problem is further examined with different boundary conditions, system configurations, or modeling options. Although relatively simple, these tests cover the basic equation models, basic component models, and basic system level processes and phenomena that must be modeled for advanced reactor safety analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗