Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Compound pulse characteristics of a heterogeneous composite scintillator in a gamma-ray field

An important aspect of radiation detection in scintillators is the time dependence of emitted fluorescence, which results in characteristic measured pulse shape. In some materials, a relatively strong dependence of the scintillation pulse shape on stopping power exists, which can provide reliable identification of the incident particle. An alternative method to realize particle identification is by combining materials with different fluorescence lifetimes into heterogeneous structures. Such composite scintillators derive their properties from both the constituent material characteristics and the geometry of the composite structure. In composite scintillators with a high degree of heterogeneous loading, a superposition of fluorescence contributions originating in multiple materials, which is observed as single waveform with an intermediate pulse shape, may affect its ability to reject rays. We measure the time dependence of light output from a scintillator composed of 6 Li-containing glass shards and scintillating polyvinyl toluene and identify events that exhibit such compound behavior when exposed to rays and fast neutrons. We develop a modeling and simulation framework that reproduces the pulse shapes in heterogeneous scintillators and use it study the effect that the weight percentage of 6 Li glass has on rejection. The modeling framework is applied to the experimentally studied scintillator, finding a good agreement. Here, the developed modeling and simulation approach will help optimize the design of heterogeneous scintillators to meet the desired trade-o between neutron capture efficiency and -ray rejection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

Validation of electron backscattering in the MCNP6.3 code

A new electron backscattering validation suite has been developed for the MCNP® code. The calculations in this suite cover both condensed history and single-event transport methods, seven different elemental materials ranging from beryllium to uranium, and incident electron energies from 200 eV to 14.1 MeV. In general, the accuracy of the MCNP code for electron backscattering calculations is energy-dependent. For incident electron energies below 2 keV, the condensed history method is not applied while the single-event method shows poor agreement with experimental measurements due to poor accuracy of the underlying atomic data. For incident energies between 2 keV and 256 keV, the single-event method typically shows better agreement with experiments, while for incident energies above 256 keV the condensed history method gives better accuracy. Additionally, agreement with experimental data is generally worse for low- Z materials such as beryllium and carbon, which may reflect deficiencies in the data or physics underlying electron transport through light elements in the MCNP code. The new electron backscattering validation suite, along with the previously introduced electron stopping power and Lockwood energy deposition validation suites, provide MCNP users with a quantified understanding of the uncertainties in electron transport calculations. Future improvements to electron transport in the MCNP code are necessary for low energies (≤ 2 keV) and for low- Z materials.

36 MATERIALS SCIENCE↗

Purification and Improved Nuclear Radiation Detection of Tl 6 SI 4 Semiconductor

The wide-band-gap semiconductor Tl 6 SI 4 (2.14 eV) has high photon stopping power and is a promising material for detecting X-rays. To improve its photoresponse to low-flux γ-rays, material purification prior to crystal growth is crucial. In this contribution, we report effective purification protocols, impurity analysis, followed by synthesis and crystal growth, charge transport, and detector performance of large-sized Tl 6 SI 4 crystals. Purification methods of evaporation and zone refining were developed, and their high effectiveness was confirmed by impurity analysis via glow discharge mass spectrometry. Centimeter-sized single crystals were grown using the Bridgman method. The improved properties after material purification were confirmed by photoluminescence measurements. The energy of the valence band maximum of a Tl 6 SI 4 , measured with photoemission spectroscopy in air (PESA), is ~5.34 ± 0.05 eV. Detector devices fabricated from the single crystal exhibit a high resistivity of 5 × 10 12 Ω·cm. The detector shows potential photoresponse under 22.4 keV Ag Kα X-rays and 122 keV γ-rays from 57 Co. Spectroscopic energy resolution was achieved for 5.5 MeV α-particles from a 241 Am radiation source with a full width at half-maximum of 27% at an electric field intensity of 2500 V·cm -1 . On the foundation of its spectral response to 57 Co γ-rays, the electron mobility-lifetime product μeτe was estimated as 1.4 × 10 -5 cm 2 ·V -1 . Drift mobility measurements via a time-of-flight technique using spectral photoresponse induced by α-particles reveal a high electron mobility of 35 ± 7 cm 2 ·V -1 ·s -1 .

36 MATERIALS SCIENCE↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

TlSn 2 I 5 , a Robust Halide Antiperovskite Semiconductor for γ-Ray Detection at Room Temperature

The semiconductor TlSn 2 I 5 with a two-dimensional crystal structure and an antiperovskite topology is a promising novel detection material. The compound crystallizes in the I4/mcm space group, has an indirect band gap of 2.14 eV, and melts congruently at 314 °C. Electronic band structure calculations reveal that the most facile electron transport is along the ab layered plane. Compared to CH 3 NH 3 PbX 3 (X = Br, I), TlSn 2 I 5 features higher long-term stability, higher photon stopping power (average atomic number of 55), higher resistivity (~10 10 Ω·cm), and robust mechanical properties. Centimeter-size TlSn 2 I 5 single crystals grown from the melt by the Bridgman method can be used to fabricate detector devices, which detect Ag Kα X-rays (22 keV), 57 Co γ-rays (122 keV), and 241 Am α-particles (5.5 MeV). The mobility-lifetime product and mobility for electrons were estimated to be 1.1 × 10 -3 cm 2 ·V -1 and 94 ± 16 cm 2 ·V -1 ·s -1 , respectively. Unlike other halide perovskites, TlSn 2 I 5 shows no signs of ionic polarization under long-term, high-voltage bias.

36 MATERIALS SCIENCE↗

Detection of magnetized quark-nuggets, a candidate for dark matter

Quark nuggets are theoretical objects composed of approximately equal numbers of up, down, and strange quarks and are also called strangelets and nuclearites. They have been proposed as a candidate for dark matter, which constitutes ~85% of the universe’s mass and which has been a mystery for decades. Previous efforts to detect quark nuggets assumed that the nuclear-density core interacts directly with the surrounding matter so the stopping power is minimal. Tatsumi found that quark nuggets could well exist as a ferromagnetic liquid with a ~10 12 -T magnetic field. We find that the magnetic field produces a magnetopause with surrounding plasma, as the earth’s magnetic field produces a magnetopause with the solar wind, and substantially increases their energy deposition rate in matter. We use the magnetopause model to compute the energy deposition as a function of quark-nugget mass and to analyze testing the quark-nugget hypothesis for dark matter by observations in air, water, and land. We conclude the water option is most promising.

79 ASTRONOMY AND ASTROPHYSICS↗

Visualization of expanding warm dense gold and diamond heated rapidly by laser-generated ion beams

With the development of several novel heating sources, scientists can now heat a small sample isochorically above 10,000 K. Although matter at such an extreme state, known as warm dense matter, is commonly found in astrophysics (e.g., in planetary cores) as well as in high energy density physics experiments, its properties are not well understood and are difficult to predict theoretically. This is because the approximations made to describe condensed matter or high-temperature plasmas are invalid in this intermediate regime. A sufficiently large warm dense matter sample that is uniformly heated would be ideal for these studies, but has been unavailable to date. We have used a beam of quasi-monoenergetic aluminum ions to heat gold and diamond foils uniformly and isochorically. For the first time, we visualized directly the expanding warm dense gold and diamond with an optical streak camera. Furthermore, we present a new technique to determine the initial temperature of these heated samples from the measured expansion speeds of gold and diamond into vacuum. We anticipate the uniformly heated solid density target will allow for direct quantitative measurements of equation-of-state, conductivity, opacity, and stopping power of warm dense matter, benefiting plasma physics, astrophysics, and nuclear physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

350 ps Ultrafast room-temperature scintillation realized on CsPbBr 3 -based single crystals via Br 2 over-doping

Ultrafast scintillators are essential for next-generation radiation detection, positron emission tomography, and high-speed medical imaging. All-inorganic CsPbBr 3 perovskites are attractive candidates because of their high stopping power, and excellent optical quality, yet their long carrier lifetimes result in slow scintillation responses on the order of hundreds of nanoseconds. Here, we demonstrate that controlled over-doping with Br 2 produces CsPbBr 3.03 single crystals with sub-nanosecond scintillation at room temperature while preserving crystal quality. Single crystals grown by the Bridgman method exhibit high transparency and maintain the orthorhombic perovskite structure. Br 2 over-doping induces a slight lattice expansion (about 0.42% increase in unit-cell volume) while maintaining the orthorhombic perovskite phase and high optical transparency. Optical absorption reveals a slight redshift of the absorption edge after Br 2 introduction, indicating a modified defect landscape. Time-resolved photoluminescence and radioluminescence measurements show that Br 2 doping creates dense and efficient recombination centers that reduce the scintillation decay time from more than 100 ns in undoped crystals to 350 ps under 5.486 MeV α-particle excitation, and the scintillation decay time decreases by two orders of magnitude. The doped crystals also achieve a spatial resolution of 12 lp mm −1 in X-ray imaging. These results reveal a defect-engineering route for achieving ultrafast scintillation in halide perovskites and highlight the potential of Br 2 -modified CsPbBr 3 for fast timing applications.

Li, Zongxiao [Chinese Academy of Sciences (CAS), N↗

Improved spectral data unfolding for radiochromic film imaging spectroscopy of laser-accelerated proton beams

An improved method to unfold the space-resolved proton energy distribution function of laser-accelerated proton beams using a layered, radiochromic film (RCF) detector stack has been developed. The method takes into account the reduced RCF response near the Bragg peak due to a high linear energy transfer (LET). This LET dependence of the active RCF layer has been measured, and published data have been re-interpreted to find a nonlinear saturation scaling of the RCF response with stopping power. Accounting for the LET effect increased the integrated particle yield by 25% after data unfolding. An iterative, analytical, space-resolved deconvolution of the RCF response functions from the measured dose was developed that does not rely on fitting. After the particle number unfold, three-dimensional interpolation is performed to determine the spatial proton beam distribution for proton energies in-between the RCF data points. Here, image morphing has been implemented as a novel interpolation method that takes into account the energy-dependent, changing beam topology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and band gap determination of irradiation-induced amorphous nano-channels in LiNbO{sub 3}

The irradiation of lithium niobate with swift heavy ions results in the creation of amorphous nano-sized channels along the incident ion path. These nano-channels are on the order of a hundred microns in length and could be useful for photonic applications. However, there are two major challenges in these nano-channels characterization: (i) it is difficult to investigate the structural characteristics of these nano-channels due to their very long length and (ii) the analytical electron microscopic analysis of individual ion track is complicated due to electron beam sensitive nature of lithium niobate. Here, we report the first high resolution microscopic characterization of these amorphous nano-channels, widely known as ion-tracks, by direct imaging them at different depths in the material, and subsequently correlating the key characteristics with electronic energy loss of ions. Energetic Kr ions ({sup 84}Kr{sup 22} with 1.98 GeV energy) are used to irradiate single crystal lithium niobate with a fluence of 2 × 10{sup 10} ions/cm{sup 2}, which results in the formation of individual ion tracks with a penetration depth of ∼180 μm. Along the ion path, electron energy loss of the ions, which is responsible for creating the ion tracks, increases with depth under these conditions in LiNbO{sub 3}, resulting in increases in track diameter of a factor of ∼2 with depth. This diameter increase with electronic energy loss is consistent with predictions of the inelastic thermal spike model. We also show a new method to measure the band gap in individual ion track by using electron energy-loss spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of proton damage in III-V semiconductors by optical spectroscopy

We studied the damage produced by 2 MeV proton radiation on epitaxially grown InGaP/GaAs structure by means of spatially resolved Raman and photoluminescence (PL) spectroscopy. The irradiation was performed parallel to the sample surface in order to determine the proton penetration range in both compounds. An increase in the intensity of longitudinal optical phonons and a decrease in the luminescence were observed. We associate these changes with the creation of defects in the damaged region, also responsible for the observed change of the carrier concentration in the GaAs layer, determined by the shift of the phonon-plasmon coupled mode frequency. From the spatially resolved profile of the PL and phonon intensities, we obtained the proton range in both materials and we compared them with stopping and range of ions in matter simulations. The comparison between the experimentally obtained proton range and simulations shows a very good agreement for GaAs but a discrepancy of 20% for InGaP. This discrepancy can be explained in terms of limitations of the model to simulate the electronic orbitals and bonding structure of the simulated compound. In order to overcome this limitation, we propose an increase in 40% in the electronic stopping power for InGaP.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors

Transition-edge sensors (TESs) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. Lastly, we show that the bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.

36 MATERIALS SCIENCE↗

Atomistic model of xenon gas bubble re-solution rate due to thermal spike in uranium oxide

Atomistic simulations are performed to study the response of Xe gas bubbles in UO 2 to ionizing fission products through the thermal spike approximation. A portion of the total electronic stopping power (S e ) is taken as the thermal spike energy through a ratio variable ζ. The thermal spike energy causes extreme melting within the fission track cylindrical region. Molecular dynamics is employed to quantify the probability of a Xe gas atom to be re-solved (re-dissolved) back into the UO 2 matrix. Subsequently, a re-solution model is developed and parametrized as a function of bubble radius (R), off-centered distance (r), and thermal spike energy (ζS e ). The off-centered distance measures the shift of the thermal spike axis from the bubble center. To evaluate the re-solution model, independent fission product yield of U-235 fission due to thermal neutrons (0.0253 eV), taken from the JEFF-3.3 database, is used. The kinetic energy of the fission products is taken from the EXFOR database. Subsequently, the decay of Se over distance for each fission product is simulated. Finally, the evaluated re-solution rate (re-solution probability per second) is presented as a function of bubble radius for a range of ζ.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theory of ignition and burn propagation in inertial fusion implosions

A detailed analytic model is presented here to investigate the physics of burn propagation in inertially confined plasmas. The onset of ignition and burn propagation occurs when alpha heating of the hot spot causes rapid ablation of shell mass into the hot spot. This allows large energy gains to be achieved since most of the fuel mass is located in the shell. Here, we first present a comprehensive review of previous analytic models that have been used to describe the physics of hot-spot evolution and ignition; we then show that a proper description of a propagating burn wave requires a comprehensive model of hot spot and shell evolution that includes proper mass conservation in the shell, fusion reactivity, and fuel depletion. The analytic theory is in good agreement with detailed radiation-hydrodynamic simulations that predict the onset of burn propagation as occurring when the yield enhancement caused by alpha heating is between 15- and 25-fold, $f_α$ ~ 1.4, where $f_α$ = alpha energy deposited/hot-spot energy at bang time, and the hot-spot burnup fraction is approximately 2%. We show that the definition of ignition is not sensitive to the alpha-particle stopping power nor asymmetries provided that the absorbed fraction of alpha particles $θ_α$ is correctly accounted for. Finally, we use the results of 2-D simulations to show that even when $θ_α$ is small and unknown (as is true in hot spots with mid modes that have significant leakage of alpha particles into the surrounding cold bubbles), one can still relate the experimentally measureable parameter $\chi^{53}_α$ to the yield amplification and the burning-plasma parameter $Q^{\text{hs}}_α$ = alpha energy deposited/total input work delivered to the hot spot

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A generalized Boltzmann kinetic theory for strongly magnetized plasmas with application to friction

Coulomb collisions in plasmas are typically modeled using the Boltzmann collision operator, or its variants, which apply to weakly magnetized plasmas in which the typical gyroradius of particles significantly exceeds the Debye length. Conversely, O’Neil has developed a kinetic theory to treat plasmas that are so strongly magnetized that the typical gyroradius of particles is much smaller than the distance of the closest approach in a binary collision. Here, we develop a generalized collision operator that applies across the full range of magnetization strength. Since there is no closed-form solution for the scattering cross section when plasma is strongly magnetized, the input to the collision operator is obtained by numerically calculating particle trajectories. To demonstrate novel physics associated with strong magnetization, it is used to compute the friction force on a massive test charge. In addition to the traditional stopping power component, this is found to exhibit a transverse component that is perpendicular to both the velocity and Lorentz force vectors in the strongly magnetized regime, as was predicted recently using linear response theory. As a result, good agreement is found between the collision theory and linear response theory in the regime in which both apply, but the new collision theory also applies to stronger magnetization strength regimes than the linear response theory is expected to apply in.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new tri-particle backlighter for high-energy-density plasmas (invited)

A new tri-particle mono-energetic backlighter based on laser-driven implosions of DT3He gas-filled capsules has been implemented at the OMEGA laser. This platform, an extension of the original D 3 He backlighter platform, generates 9.5 MeV deuterons from the T3He reaction in addition to 14.7 and 3.0 MeV protons from the deuterium and helium-3 reactants. The monoenergetic 14.7 and 3.0 MeV protons have been used with success at OMEGA and the NIF for both radiography and stopping-power studies. There are several advantages of having a third particle to diagnose plasma conditions: an extra time-of-flight-separated radiograph and an improved ability to discern between electric and magnetic fields. In cases where the 3.0 MeV protons cannot penetrate an experiment, the benefit of the additional 9.5 MeV deuterons is magnified. This capability is well-suited for NIF experiments, where large fields and plasma densities often preclude useful 3.0 MeV proton data. The advantages are demonstrated with radiographs of OMEGA plasmas with magnetic and electric fields. Tests using backlighter-scale 420 μm diameter thin glass capsules validate the platform’s extended backlighting capability. The performance characteristics of this backlighter, such as source size and timing, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗