Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STIMULUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Computational Analysis of Artificial Gravity as a Possible Countermeasure to Spaceflight Induced Bone Loss

During exploration class missions, such as to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Data has shown that astronauts lose bone mass at a rate of 1% to 2% a month in microgravity, particularly in lower extremities such as the proximal femur. Exercise countermeasures have not completely eliminated bone loss from long duration spaceflight missions, which leaves astronauts susceptible to early onset osteoporosis and greater risk of fracture. Introduction of the Advanced Resistive Exercise Device and other large exercise devices on the International Space Station (ISS), coupled with improved nutrition, has further minimized bone loss. However, unlike the ISS, exploration vehicles will have very limited volume and power available to accommodate such capabilities. Therefore, novel concepts like artificial gravity systems are being explored as a means to provide sufficient load stimulus to the musculoskeletal system to mitigate bone changes that may lead to early onset osteoporosis and increased risk of fracture. Currently, there is minimal data available to drive further research and development efforts to appropriately explore such options. Computational modeling can be leveraged to gain insight on the level of osteoprotection that may be achieved using artificial gravity produced by a spinning spacecraft or centrifuge. With this in mind, NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone both for gravitational unloading condition and the equivalent of 1g daily load stimulus. Using this model, it is possible to simulate vBMD changes in trabecular and cortical bone under different gravity conditions. In this presentation, we will discuss our preliminary findings regarding if and how artificial gravity may be used to mitigate spaceflight induced bone loss.

Mulugeta, L.↗

Mapping Electrical Crosstalk in Pixelated Sensor Arrays

Electronic coupling effects such as Inter-Pixel Capacitance (IPC) affect the quantitative interpretation of image data from CMOS, hybrid visible and infrared imagers alike. Existing methods of characterizing IPC do not provide a map of the spatial variation of IPC over all pixels. We demonstrate a deterministic method that provides a direct quantitative map of the crosstalk across an imager. The approach requires only the ability to reset single pixels to an arbitrary voltage, different from the rest of the imager. No illumination source is required. Mapping IPC independently for each pixel is also made practical by the greater S/N ratio achievable for an electrical stimulus than for an optical stimulus, which is subject to both Poisson statistics and diffusion effects of photo-generated charge. The data we present illustrates a more complex picture of IPC in Teledyne HgCdTe and HyViSi focal plane arrays than is presently understood, including the presence of a newly discovered, long range IPC in the HyViSi FPA that extends tens of pixels in distance, likely stemming from extended field effects in the fully depleted substrate. The sensitivity of the measurement approach has been shown to be good enough to distinguish spatial structure in IPC of the order of 0.1%.

focal plane array↗

Simulated Space Radiation: Murine Skeletal Responses During Recovery and with Mechanical Stimulation

Simulated space radiation at doses similar to those of solar particle events or a round-trip sojourn to Mars (1-2Gy) may cause skeletal tissue degradation and deplete stem/progenitor cell pools throughout the body. We hypothesized that simulated space radiation (SSR) causes late, time-dependent deficits in bone structure and bone cell function reflected by changes in gene expression in response to anabolic stimuli. We used a unique sequential dual ion exposure (proton and iron) for SSR to investigate time-dependence of responses in gene expression, cell function, and microarchitecture with respect to radiation and an anabolic stimulus of axial loading (AL). Male 16-wk C57BL6/J mice (n=120 total) were exposed to 0Gy (Sham, n=10), 56Fe (2Gy, positive control dose, n=10), or sequential ions for SSR (1Gy 1H/56Fe/1H, n=10) by total body irradiation (IR), and the tissues were harvested 2 or 6 mo. later. Further, to assess the response to anabolic stimuli, we subjected additional Sham-AL (n=15) and SSR-AL (n=15) groups to rest-inserted tibial axial loading (AL) starting at 1 and 5 months post-IR (-9N, 60 cycles/day, 3 days/wk, 4 wks). Exposure to 56Fe caused a significant reduction in cancellous bone volume fraction (BV/TV) compared to Sham (-34%) and SSR (-20%) in the proximal tibia metaphysis at 2-months post-IR; however BV/TV for SSR group was not different than Sham. Both 56Fe and SSR caused significant reduction in trabecular number (Tb.N) compared to Sham (-33% and -16%, respectively). Further, Tb.N for 56Fe (2Gy) was significantly lower than SSR (-21%). Ex vivo culture of marrow cells to assess growth and differentiation of osteoblast lineage cells 6 months post-IR showed that both 56Fe and SSR exposures significantly impaired colony formation compared to Sham (-66% and -54%, respectively), as well as nodule mineralization (-90% and -51%, respectively). Two-way analysis of variance showed that both mechanical loading and radiation reduced BV/TV, mechanical loading reduced trabecular thickness (Tb.Th), and radiation reduced Tb.N, at both time points. To assess acute response to mechanical stimuli, samples were harvested from a subset of Sham-AL (n=5) and SSR-AL (n=5) to measure changes in gene expression levels. Preliminary results indicate that axial loading increased expression of the antioxidant response gene Nfe2l2 and the osteoprogenitor-associated marker Runx2 in the bone marrow cells, and there was an interaction effect between axial loading and radiation at 2-months post-IR. Additional analyses of gene expression levels in the mineralized tissue are in progress. Results indicate that SSR caused persistent impairment of osteoblast colony formation and nodule mineralization 6-mo post-IR. Contrary to our hypothesis, simulated space radiation did not impair the ability of cancellous bone to respond to a mechanical anabolic stimulus, consistent with our previous findings [1]. Hence, compressive loading may be a potential countermeasure against spaceflight-induced bone loss.

Bone Loss↗

Simulated Space Radiation: Murine Skeletal Responses During Recovery and with Mechanical Stimulation

Simulated space radiation at doses similar to those of solar particle events or a round-trip sojourn to Mars (1-2Gy) may cause skeletal tissue degradation and deplete stem/progenitor cell pools throughout the body. We hypothesized that simulated space radiation (SSR) causes late, time-dependent deficits in bone structure and bone cell function reflected by changes in gene expression in response to anabolic stimuli. We used a unique sequential dual ion exposure (proton and iron) for SSR to investigate time-dependence of responses in gene expression, cell function, and microarchitecture with respect to radiation and an anabolic stimulus of axial loading (AL). Male 16-wk C57BL6/J mice (n=120 total) were exposed to 0Gy (Sham, n=10), 56Fe (2Gy, positive control dose, n=10), or sequential ions for SSR (1Gy 1H/56Fe/1H, n=10) by total body irradiation (IR), and the tissues were harvested 2 or 6 mo. later. Further, to assess the response to anabolic stimuli, we subjected additional Sham-AL (n=15) and SSR-AL (n=15) groups to rest-inserted tibial axial loading (AL) starting at 1 and 5 months post-IR (-9N, 60 cycles/day, 3 days/wk, 4 wks). Exposure to 56Fe caused a significant reduction in cancellous bone volume fraction (BV/TV) compared to Sham (-34%) and SSR (-20%) in the proximal tibia metaphysis at 2-months post-IR; however BV/TV for SSR group was not different than Sham. Both 56Fe and SSR caused significant reduction in trabecular number (Tb.N) compared to Sham (-33% and -16%, respectively). Further, Tb.N for 56Fe (2Gy) was significantly lower than SSR (-21%). Ex vivo culture of marrow cells to assess growth and differentiation of osteoblast lineage cells 6 months post-IR showed that both 56Fe and SSR exposures significantly impaired colony formation compared to Sham (-66% and -54%, respectively), as well as nodule mineralization (-90% and -51%, respectively). Two-way analysis of variance showed that both mechanical loading and radiation reduced BV/TV, mechanical loading reduced trabecular thickness (Tb.Th), and radiation reduced Tb.N, at both time points. To assess acute response to mechanical stimuli, samples were harvested from a subset of Sham-AL (n=5) and SSR-AL (n=5) to measure changes in gene expression levels. Preliminary results indicate that axial loading increased expression of the antioxidant response gene Nfe2l2 and the osteoprogenitor-associated marker Runx2 in the bone marrow cells, and there was an interaction effect between axial loading and radiation at 2-months post-IR. Additional analyses of gene expression levels in the mineralized tissue are in progress. Results indicate that SSR caused persistent impairment of osteoblast colony formation and nodule mineralization 6-mo post-IR. Contrary to our hypothesis, simulated space radiation did not impair the ability of cancellous bone to respond to a mechanical anabolic stimulus, consistent with our previous findings. Hence, compressive loading may be a potential countermeasure against spaceflight-induced bone loss.

MURINE SKELETAL↗

Evaluation of Galvanic Vestibular Stimulation System

Microgravity exposure results in an adaptive central reinterpretation of information from multiple sensory sources to produce a sensorimotor state appropriate for motor actions in this unique environment, but this new adaptive state is no longer appropriate for the 1-g gravitational environment on Earth. During these gravitational transitions, astronauts experience deficits in both perceptual and motor functions including impaired postural control, disruption in spatial orientation, impaired control of locomotion that include alterations in muscle activation variability, modified lower limb kinematics, alterations in head-trunk coordination as well as reduced dynamic visual acuity. Post-flight changes in postural and locomotor control might have adverse consequences if a rapid egress was required following a long-duration mission, where support personnel may not be available to aid crewmembers. The act of emergency egress includes, but is not limited to standing, walking, climbing a ladder, jumping down, monitoring displays, actuating discrete controls, operating auxiliary equipment, and communicating with Mission Control and recovery teams while maintaining spatial orientation, mobility and postural stability in order to escape safely. The average time to recover impaired postural control and functional mobility to preflight levels of performance has been shown to be approximately two weeks after long-duration spaceflight. The postflight alterations are due in part to central reinterpretation of vestibular information caused by exposure to microgravity. In this study we will use a commonly used technique of transcutaneous electrical stimulation applied across the vestibular end organs (galvanic vestibular stimulation, GVS) to disrupt vestibular function as a simulation of post-flight disturbances. The goal of this project is an engineering human-in-the-loop evaluation of a device that can degrade performance of functional tasks (e.g. to maintain upright balance) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

Kofman, I. S.↗

Implementation and Integration of a Finite Element Model into the Bone Remodeling Model to Characterize Skeletal Loading

NASA's Digital Astronaut Project is developing a bone physiology model to predict changes in bone mineral density over the course of a space mission. The model intends to predict bone loss due to exposure in microgravity as well as predicting bone maintenance due to mechanical stimulus generated by exercise countermeasures. These predictions will be used to inform exercise device efficacy and to help design exercise protocols that will maintain bone mineral density during long exposures to microgravity during spaceflight. The mechanical stimulus and the stresses that are exhibited on the bone are important factors for bone remodeling. These stresses are dependent on the types of exercise that are performed and vary throughout the bone due to the geometry. A primary area of focus for bone health is the proximal femur. This location is critical in transmitting loads between the upper and lower body and have been known to be a critical failure point in older individuals with conditions like osteoporosis.

bone mineral content↗

Smooth Pursuit of Flicker-Defined Motion

We examined the pursuit response to stimuli defined by space-variant flicker of a dense random dot carrier pattern. On each frame, every element of the pattern could change polarity, with a probability given by a two-dimensional Gaussian distribution. A normal distribution produces a circular region of twinkle, while inverting the distribution results in a spot of static texture in a twinkling surround. In this latter case, the carrier texture could be stationary, or could move with the twinkle modulator,thereby producing first-order motion in the region of the spot. While the twinkle-defined spot produces a strong sensation of motion, the complementary stimulus defined by the absence of twinkle does not;when viewed peripherally, it appears to move in steps even when the generating distribution moves smoothly. We examined pursuit responses to these stimuli using two techniques: 1) the eye movement correlogram, obtained by cross-correlating eye velocity with the velocity of a randomly-moving stimulus; and 2) delayed visual feedback, where transient stabilization of a target can produce spontaneous oscillations of the eye, with a period empirically observed to vary linearly with the applied delay. Both techniques provide an estimate of the internal processing time, which can be as short as100 milliseconds for a first-order target. Assessed by the correlogram method, the response to flicker defined motion is delayed by more than 100 milliseconds, and significantly weaker (especially in the vertical dimension). When initially presented in the delayed feedback condition, purely saccadic oscillation is observed. One subject eventually developed smooth oscillations (albeit with significant saccadic intrusions), showing a period-versus-delay slope similar to that observed for first-order targets. This result is somewhat surprising, given that we interpret the slope of the period-versus-delayfunction as reflecting the balance between position- and velocity-sensitive inputs to pursuit.

smooth pursuit↗

Use of Otoacousticemission Phase Change to Evaluate Countermeasures for Spaceflight-Associated Neuro-Ocular Syndrome

Spaceflight-associated neuro-ocular syndrome (SANS) is a human spaceflight risk recognized by NASA. Elevated intracranial pressure (ICP) has been implicated as a root cause of many SANS signs and symptoms, yet there is no reliable noninvasive means of monitoring ICP. We have developed a noninvasive method of monitoring ICP change that exploits ear canal acoustic and otoacoustic emission (OAE) measurements. Changed ICP alters pressure in the inner ear, leading to changes in the tension and position of middle ear (ME) components; tension of these components determines the phase of the stimulus in the ear canal and the OAE response sound transmission back through the ME. The OAE method has been validated in several studies, including our own experiments as part of the NASA Fluid Shifts study. Systematic OAE phase changes demonstrating increased ME tension (an ICP indicator) are observed as posture is changed from seated to supine to head-down tilt (HDT). This effect can be substantially mitigated by lower body negative pressure (LBNP). The OAE technique has also been used on International Space Station (ISS) crewmembers, providing evidence that ICP in microgravity is similar to that seen on the ground in the supine position. The OAE method is also a rapid and noninvasive means of assessing the effectiveness of SANS countermeasures. Here we report results from two studies which used OAEs. In the most recent study (Venous Congestion Countermeasures - VCCM), three promising countermeasures [LBNP, an impedance threshold device (ITD), and veno-occlusive thigh cuffs (VTC)] were applied individually and in combination. In our previous ITD-only study, ITD was investigated for its ability to reduce ICP and cephalic venous congestion in supine and various HDT postures. Internal jugular vein (IJV) ultrasound showed a clear decongestive effect at all postures, however OAE data showed that ITD only caused a phase decrease (tension decrease) in HDT postures. In supine, ITD appeared to INCREASE tension. This paradox leads us to hypothesize that the OAE method is not accurately representing ICP changes with countermeasures (CM), which can alter ME tension through other means, such as ME pressure (MEP) changes. More generally, the exact mechanism for observed OAE response and stimulus phase shifts are not clearly understood, specifically with regard to the effects of MEP. The VCCM study examined the effects of externally-applied MEP on OAE recordings to document the relationship between these parameters. Analysis of these data provide new insights to these OAE mechanisms, in addition to results on CM effectiveness.

Kemp, D.↗

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger↗

Exploration Exercise System (EES) Physiology

Exploration class missions will be required to have an exercise device that is lightweight, has a small footprint, and is capable of providing enough physical stimulus and exercise variability to be an effective countermeasure against muscle, bone, aerobic fitness, and sensorimotor loss that results from the microgravity environment. Ground studies, inflight studies, and results analyses are required to inform Moon2Mars Design Reference Missions (DRMs) and vehicle designs. This activity encompasses two related projects, an evaluation study called Zero T2 and a requirements development for an exploration treadmill (ET). Exploration class missions’ mass/power/volume restrictions have resulted in the development of exercise devices that are motorized and flywheel-based to provide both aerobic and resistive training on one platform. These devices provide a variety of full body resistance exercise options as well as rowing and cycling for aerobic exercise, but do not provide ambulatory exercise via a treadmill. Because a treadmill has been available for use on the ISS since 2001, we do not understand the efficacy of exploration exercise modalities on muscle performance, aerobic fitness, bone health, or sensorimotor performance. A retrospective study was performed to quantify the association between total exercise (including specific contributions of treadmill exercise) and functional performance upon landing. Due to the relatively small variation in treadmill usage inflight, there is a need to do a controlled study where inflight crewmembers will not use the ISS treadmill (called T2) for the duration of their flights. There will be 3 arms to the Zero T2 study: 1) participants use all currently available exercise platforms aboard ISS (control group), 2) participants use only ARED and CEVIS, and 3) participants use only European Enhanced Exploration Device (E4D). (Please see the TechPort Entry for Exploration Exercise System Development for further detail on the E4D.) This study started in Oct 2020 and will continue through Sep 2027. In a parallel effort, a team will be developing requirements for an exploration treadmill. This project will be broken into two phases. Phase 1 will develop and implement energy prediction models based on available in-flight exercise data to quantify energy expenditure during 0g treadmill running. Phase 2 will then use the available biomechanical and metabolic evidence from Phase 1 to determine the hardware specification requirements essential to providing the desired exercise stimulus. Subject Matter Experts (SMEs) will then leverage the Standardized Process for Evaluating Exercise Devices (SPEED) developed by the team to 1) assess available technologies for candidate treadmills which meet defined requirements, 2) perform hands-on evaluations of top candidates, 3) provide evaluation outcomes and recommendations to developers. This project will begin in 2025 and continue through Sep 2030.

Kent Lawrence Kalogera↗

Automatic recognition of malicious intent indicators.

A major goal of next-generation physical protection systems is to extend defenses far beyond the usual outer-perimeter-fence boundaries surrounding protected facilities. Mitigation of nuisance alarms is among the highest priorities. A solution to this problem is to create a robust capability to Automatically Recognize Malicious Indicators of intruders. In extended defense applications, it is not enough to distinguish humans from all other potential alarm sources as human activity can be a common occurrence outside perimeter boundaries. Our approach is unique in that it employs a stimulus to determine a malicious intent indicator for the intruder. The intruder's response to the stimulus can be used in an automatic reasoning system to decide the intruder's intent.

99 GENERAL AND MISCELLANEOUS↗

Aggregate Load Controllers and Associated Methods

Aggregate load controllers and associated methods are described. According to one aspect, a method of operating an aggregate load controller includes using an aggregate load controller having an initial state, applying a stimulus to a plurality of thermostatic controllers which are configured to control a plurality of respective thermostatic loads which receive electrical energy from an electrical utility to operate in a plurality of different operational modes, accessing data regarding a response of the thermostatic loads as a result of the applied stimulus, using the data regarding the response, determining a value of at least one design parameter of the aggregate load controller, and using the determined value of the at least one design parameter, configuring the aggregate load controller to control amounts of the electrical energy which are utilized by the thermostatic loads.

47 OTHER INSTRUMENTATION↗

Analysis and categorization of eye tracking data describing scanpaths

Described herein are various technologies pertaining to analysis of eye tracking data. A head and/or eyes of an observer who is viewing a visual stimulus is monitored, and eye tracking data that is representative of the path of the eyes of the observer over time (a scanpath) is generated. The eye tracking data is time-series data that defines the location of the focal point, or other measurable characteristics, of the eyes of the observer on the visual stimulus over time. A feature vector is constructed based upon the eye tracking data, where the feature vector is representative of the eye tracking data, and is thus representative of the scanpath. The feature vector is compared with other feature vectors to identify scanpaths that correspond to the scanpath represented by the feature vector.

47 OTHER INSTRUMENTATION↗

Method and apparatus for shape-based energy analysis of solids

A method of evaluating response of a physical structure to external stimulus includes defining a mesh of finite elements, each defined by edges, for a model of the physical structure. The method includes identifying a governing differential equation and associated complementary functions, which are each associated with a scalar multiplier. The method includes generating an energy optimization model that minimizes a difference between internal and external energies of the finite elements. The internal energy is based on strain energy in a volume defined by the edges of the finite element and resulting from deformations by the complementary functions. The external energy of each finite element is based on external work done by the external stimulus acting on the finite element as deformed by the complementary functions. The method includes solving the energy optimization model for the scalar multipliers and calculating a resulting parameter of interest of the physical structure.

42 ENGINEERING↗

Modular electrode tool for improved hydraulic fracture diagnostics

Systems and methods for assessing physical properties of a geological formation are disclosed. The systems and methods may use electrodes that include two conductive portions separated by an isolation gap positioned along a casing in a wellbore in the formation. The electrodes may be sequentially energized to provide excitation stimulus into the formation while the remaining, non-energized electrodes may substantially simultaneously receive excitation responses to the excitation stimulus from the formation. The excitation responses may be assessed to determine one or more physical properties of fractures in the formation.

58 GEOSCIENCES↗

Method and apparatus for shape-based energy analysis of solids

A computer-readable medium stores instructions including storing a model of a physical structure and defining a mesh for the model. The mesh includes finite elements, each defined by a respective set of edges. The instructions include, for each finite element, identifying a governing differential equation and a set of complementary functions that exactly satisfy the governing differential equation. The instructions include determining an applied physical stimulus for the physical structure. The instructions include generating an energy optimization model that minimizes a difference between internal energy and external energy of the finite elements in response to the applied physical stimulus. The model includes a matrix of respective scalar multipliers for the complementary functions for each finite element. The instructions include transforming the matrix and calculating a physical parameter of interest. The instructions include, in response to the physical parameter not satisfying a design parameter, updating the model of the physical structure.

Spears, Robert E.↗

Texas A&M University - Lake Granbury and Bosque River Assessment (Final Scientific/Technical Report)

The “Texas A&M University – Lakes Granbury and Waco, and Bosque River Assessment” project was developed to address two separate water quality issues in Central Texas. Prior work in each waterbody has identified major water quality concerns and laid the ground work for the activities conducted in this project. Lake Granbury and the Bosque River both serve vital roles in the Brazos River watershed. Lake Granbury is a reservoir constructed on the main stem of the Brazos River in Hood County, Texas and provides a potable water supply for over 250,000 area residents, cooling water for a natural gas fired and a nuclear power plant, vital flood control for the city of Waco and a critical economic stimulus for the city of Granbury and surrounding areas. The Bosque River, also in the Brazos River watershed plays a vital role in Central Texas as well; it feeds Lake Waco and supplies water for 200,000 Central Texans. Lake Granbury has experienced recent toxic blooms of Prymnesium parvum (Golden algae) that have resulted in massive fish kills and concerns about general water quality. Lake Waco, a reservoir constructed on the main stem of the Bosque River, has viable P. parvum populations, but does not experience harmful blooms. Thus, comparisons between Lakes Granbury and Waco allow for comparisons of environmental conditions leading to bloom formation. Both Lake Granbury and Lake Waco are critical to this region as being primary water supplies, sources of revenue and recreational hotspots. This project addressed these water quality issues by providing critical information about the relationships between the contaminants (Golden algae and nutrients) and environmental factors in the respective watersheds. In Lakes Granbury and Waco, various plankton, nutrient and water quality samples were collected at fixed-location stations, and high-resolution spatial maps were generated using an on-board dataflow technology of various plankton and water quality parameters. Linkages between the toxic Golden algae blooms and environmental conditions were examined. In addition, a numerical model of Lake Granbury was developed and continues to be refined. Bloom forming processes were investigated with this model. In the Bosque River, elevated nutrient levels have lead to increased aquatic vegetation growth and subsequent taste and odor problems in Lake Waco. This project enlists physically based computer modeling to determine the nutrient and sediment removal capabilities of implementing recommended Best Management Practices (BMPs) throughout the watershed. Results of this project indicate areas where specific management strategies will provide the most pollutant control for the cost to implement the practice. Each project is focused on addressing specific water quality issues in a specific water body, but each will provide valuable information that can be used to correct water quality concerns in other watersheds with similar problems. Ultimately, the project will result in improved water quality for consumptive, recreational, and industrial uses and will help to sustain the economic stimulus resulting from these water bodies.

54 ENVIRONMENTAL SCIENCES↗

Biological preconcentrator

A biological preconcentrator comprises a stimulus-responsive active film on a stimulus-producing microfabricated platform. The active film can comprise a thermally switchable polymer film that can be used to selectively absorb and desorb proteins from a protein mixture. The biological microfabricated platform can comprise a thin membrane suspended on a substrate with an integral resistive heater and/or thermoelectric cooler for thermal switching of the active polymer film disposed on the membrane. The active polymer film can comprise hydrogel-like polymers, such as poly(ethylene oxide) or poly(n-isopropylacrylamide), that are tethered to the membrane. The biological preconcentrator can be fabricated with semiconductor materials and technologies.

59 BASIC BIOLOGICAL SCIENCES↗