Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Genome-Resolved Metagenomics of Nitrogen Transformations in the Switchgrass Rhizosphere Microbiome on Marginal Lands

Switchgrass (Panicum virgatum L.) remains the preeminent American perennial (C4) bioenergy crop for cellulosic ethanol, that could help displace over a quarter of the US current petroleum consumption. Intriguingly, there is often little response to nitrogen fertilizer once stands are established. The rhizosphere microbiome plays a critical role in nitrogen cycling and overall plant nutrient uptake. We used high-throughput metagenomic sequencing to characterize the switchgrass rhizosphere microbial community before and after a nitrogen fertilization event for established stands on marginal land. We examined community structure and bulk metabolic potential, and resolved 29 individual bacteria genomes via metagenomic de novo assembly. Community structure and diversity were not significantly different before and after fertilization; however, the bulk metabolic potential of carbohydrate-active enzymes was depleted after fertilization. We resolved 29 metagenomic assembled genomes, including some from the ‘most wanted’ soil taxa such as Verrucomicrobia, Candidate phyla UBA10199, Acidobacteria (rare subgroup 23), Dormibacterota, and the very rare Candidatus Eisenbacteria. The Dormibacterota (formally candidate division AD3) we identified have the potential for autotrophic CO utilization, which may impact carbon partitioning and storage. Our study also suggests that the rhizosphere microbiome may be involved in providing associative nitrogen fixation (ANF) via the novel diazotroph Janthinobacterium to switchgrass.

60 APPLIED LIFE SCIENCES↗

Allometric, Growth, and Biomass Estimation Models for Acacia dealbata Link.: A Case Study in Serra da Estrela Natural Park (Portugal)

Allometric, growth, and biomass estimation models for the quantification of missing parameters in trees are widely used to estimate the productivity of a stand. However, regarding species with lower economic interest, or exotic invasive species, the creation of these tools did not occur in the same way as for other species, lacking the development of relationships to allow a deeper study of these species. Thus, data were collected in a settlement of Acacia dealbata Link. in Portugal, in an area known for the current infestation of this species. After a bibliographic review, some of the identified models were tested to select those who best fit the characteristics of this stand, which were used to develop relationships that, based on the data collected, would be able to estimate parameters, such as height, volume, or mass. It was found that the models established, at least for the initial 20 years of the life of the trees, followed close to a linear model. However, the model still presents some weaknesses. For being considered an invasive species in Portugal, A. dealbata is frequently controlled, and for this reason it is very difficult to find trees older than 20 years.

Nunes, Leonel J. R. (ORCID:0000000154048163)↗

Aboveground Wood Production Is Sustained in the First Growing Season after Phloem-Disrupting Disturbance

Carbon (C) cycling processes are particularly dynamic following disturbance, with initial responses often indicative of longer-term change. In northern Michigan, USA, we initiated the Forest Resilience Threshold Experiment (FoRTE) to identify the processes that sustain or lead to the decline of C cycling rates across multiple levels (0, 45, 65 and 85% targeted gross leaf area index loss) of disturbance severity and, in response, to separate disturbance types preferentially targeting large or small diameter trees. Simulating the effects of boring insects, we stem girdled > 3600 trees below diameter at breast height (DBH), immediately and permanently disrupting the phloem. Weekly DBH measurements of girdled and otherwise healthy trees (n > 700) revealed small but significant increases in daily aboveground wood net primary production (ANPP w ) in the 65 and 85% disturbance severity treatments that emerged six weeks after girdling. However, we observed minimal change in end-of-season leaf area index and no significant differences in annual ANPP w among disturbance severities or between disturbance types, suggesting continued C fixation by girdled trees sustained stand-scale wood production in the first growing season after disturbance. We hypothesized higher disturbance severities would favor the growth of early successional species but observed no significant difference between early and middle to late successional species’ contributions to ANPP w across the disturbance severity gradient. We conclude that ANPP w stability immediately following phloem disruption is dependent on the continued, but inevitably temporary, growth of phloem-disrupted trees. Our findings provide insight into the tree-to-ecosystem mechanisms supporting stand-scale wood production stability in the first growing season following a phloem-disrupting disturbance.

54 ENVIRONMENTAL SCIENCES↗

Belowground Biomass and Root:Shoot Ratios of Three Willow Cultivars at Two Sites

Belowground biomass is an important but less studied component of energy crop systems that is essential in understanding the greenhouse gas benefits of these systems. In this study, a complete above- and belowground biomass inventory (foliage, stems, stools, coarse and fine roots) was performed on three cultivars of short-rotation willow biomass crops at two sites. Mixed models were used to analyze the proportion of biomass allocated to each component and the ratios between different components. The root:shoot (R:S) ratio, defined here as the stable unharvested biomass (stool and coarse roots) divided by the shoot biomass, averaged 0.63 (SE: +0.04). Though the portion of the plant where the willows distributed their belowground biomass varied, the R:S ratio was not significantly different across sites (p = 0.8970), cultivars (p = 0.2834), nor in the site × cultivar interaction (p = 0.8481). These results may be associated with the consistently good growth across sites and limited differences in site conditions. However, the R:S ratios were affected by the overall productivity of the stand (p = 0.0978), with higher producing stands having moderately lower ratios. This information on biomass allocation between components is essential for understanding and estimating the carbon balance of these systems and breeding and selection programs.

09 BIOMASS FUELS↗

Void-Engineered Metamaterial Delay Line with Built-In Impedance Matching for Ultrasonic Applications

Metamaterials exhibit unique ultrasonic properties that are not always achievable with traditional materials. However, the structures and geometries needed to achieve such properties are often complex and difficult to obtain using common fabrication techniques. In the present research work, we report a novel metamaterial acoustic delay line with built-in impedance matching that is fabricated using a common 3D printer. Delay lines are commonly used in ultrasonic inspection when signals need to be separated in time for improved sensitivity. However, if the impedance of the delay line is not perfectly matched with those of both the sensor and the target medium, a strong standing wave develops in the delay line, leading to a lower energy transmission. The presented metamaterial delay line was designed to match the acoustic impedance at both the sensor and target medium interfaces. This was achieved by introducing graded engineered voids with different densities at both ends of the delay line. The measured impedances of the designed metamaterial samples show a good match with the theoretical predictions. The experimental test results with concrete samples show that the acoustic energy transmission is increased by 120% and the standing wave in the delay line is reduced by over a factor of 2 compared to a commercial delay line.

36 MATERIALS SCIENCE↗

CMIP5 model selection for ISMIP6 ice sheet model forcing: Greenland and Antarctica

Abstract. The ice sheet model intercomparison project for CMIP6 (ISMIP6) effort brings together the ice sheet and climate modeling communities to gain understanding of the ice sheet contribution to sea level rise. ISMIP6 conducts stand-alone ice sheet experiments that use space- and time-varying forcing derived from atmosphere–ocean coupled global climate models (AOGCMs) to reflect plausible trajectories for climate projections. The goal of this study is to recommend a subset of CMIP5 AOGCMs (three core and three targeted) to produce forcing for ISMIP6 stand-alone ice sheet simulations, based on (i) their representation of current climate near Antarctica and Greenland relative to observations and (ii) their ability to sample a diversity of projected atmosphere and ocean changes over the 21st century. The selection is performed separately for Greenland and Antarctica. Model evaluation over the historical period focuses on variables used to generate ice sheet forcing. For stage (i), we combine metrics of atmosphere and surface ocean state (annual- and seasonal-mean variables over large spatial domains) with metrics of time-mean subsurface ocean temperature biases averaged over sectors of the continental shelf. For stage (ii), we maximize the diversity of climate projections among the best-performing models. Model selection is also constrained by technical limitations, such as availability of required data from RCP2.6 and RCP8.5 projections. The selected top three CMIP5 climate models are CCSM4, MIROC-ESM-CHEM, and NorESM1-M for Antarctica and HadGEM2-ES, MIROC5, and NorESM1-M for Greenland. This model selection was designed specifically for ISMIP6 but can be adapted for other applications.

54 ENVIRONMENTAL SCIENCES↗

Semi-Transparent Perovskite Solar Cells in a Stacked Tandem Module: Cooperative Research and Development Final Report, CRADA Number CRD-19-00810

This project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, anti-reflection layer composition and deposition process, and cell to module integration processes. Modification 5: The proposed project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically-stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, passivation layers including in module scribes, anti-reflection layer composition and deposition process, and cell to module integration processes. Advanced metrology and characterization will be performed on perovskite films, cells and module. Furthermore, we will examine module or materials recycling for circular economy considerations. Modifcation 6: Gigahertz frequency microwave pump-probe spectroscopies are highly sensitive to thin film semiconductor photoconductivity of individual and stacks of layers that comprise perovskite solar cells. As such, these techniques will be used to qualify reproducibility and quality correlations during the manufacturing process. Modification 7: Mechanical adhesion of top contacts within perovskite modules significantly impacts the durability of the module when exposed to accelerated degradation testing. The adhesion between the perovskite/transport layer interface and the transport layer/top contact interface are both very sensitive small changes in processing. ALD processing conditions of the transport layer will be tuned to optimize the mechanical adhesion within the perovskite module stack.

14 SOLAR ENERGY↗

Stretchable electronic systems with containment chambers

The present invention provides electronic systems, including device arrays, comprising functional device(s) and/or device component(s) at least partially enclosed via one or more containment chambers, such that the device(s) and/or device component(s) are at least partially, and optionally entirely, immersed in a containment fluid. Useful containment fluids for use in containment chambers of electronic devices of the invention include lubricants, electrolytes and/or electronically resistive fluids. In some embodiments, for example, electronic systems of the invention comprise one or more electronic devices and/or device components provided in free-standing and/or tethered configurations that decouple forces originating upon deformation, stretching or compression of a supporting substrate from the free standing or tethered device or device component.

Rogers, John A.↗

Tritium Transport Phenomena in Molten-Salt Reactors: Molten Salt Tritium Transport Experiment Design

Tritium is produced from neutron interactions with both lithium and beryllium. Large quantities of tritium are generated in Molten Salt Reactors (MSRs) which use LiF/BeF2 (FLiBe) as the fuel salt. Tritium is unique among the radionuclide hazards as it readily permeates through metal structural materials at high temperatures. All metal surfaces are potential release paths for tritium. For adequate safety analysis and eventual licensing of new reactors, predictive models for tritium transport and release from MSRs must be developed. These models must account for the multiple transport phenomena involved with tritium: fuel salt phase mass transport, dissociation/recombination reactions on metal surfaces, interstitial diffusion through the metal structure, and salt or gas phase mass transport in the downstream fluid. These models also must also be validated with representative experiments. Our previous report outlined tritium transport phenomena involved in MSRs, made suggestions on gaps in the transport dataset, and proposed an experimental test stand to test combined transport effects – tritium transport through pipe walls in a convective salt flow. In this report, we summarize an updated analysis framework for tritium transport in MSRs, report our results on hydrogen and deuterium permeation through Hastelloy N, and describe the final design of the Molten Salt Tritium Transport Experiment (MSTTE, pronounced “misty”). The MSRE provides the only wholistic experimental data set for tritium transport in MSRs and understanding the transport phenomena involved in the MSRE is crucial for future model development. One set of parameters in our analysis framework was unknown for the MSRE—surface reaction rates for tritium on Hastelloy N. This warranted our hydrogen and deuterium permeation campaign to assess the permeability, diffusivity, and solubility of hydrogen isotopes in clean Hastelloy N. Surface reaction rate constants were probed by low pressure measurements, however, no surface effects were observed in the limits of our permeation apparatus. Permeation experiments on oxidized Hastelloy N were not performed for this report but are planned in future work. The experimental test stand, MSTTE, measures combined transport properties of the salt-metal system. MSTTE is a forced convection FLiBe loop with custom designed test section to measure tritium transport through candidate structural materials. We use MSRE relevant dimensionless numbers to design and scale the test section. Hastelloy N is a candidate loop and test section material due to the relevance for the MSRE and related designs, however, other metals are being considered (e.g. 316H SS) which may better align with current vendor concepts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermionic Sources For Electron Cooling At IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project at the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling of 2.5 MeV protons in the presence of intense space-charge. Furthermore, we are constructing an electron source test stand at the University of Chicago which will validate the electrical, thermal, and vacuum characteristics of thermionic sources. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources for electron cooling and the test stand.

43 PARTICLE ACCELERATORS↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site Integration and Regulatory Considerations for a Nuclear Power Plant Colocated with Industrial Facilities: Colocation Studies for a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 HYDROGEN↗

AquaPV: Regulatory and Environmental Considerations for Floating Photovoltaic Projects Located on Federally Controlled Reservoirs in the United States

To meet the nation's decarbonization goals, the U.S. Department of Energy's Solar Futures study forecasts that installed solar photovoltaic (PV) capacity must increase nearly tenfold, from 80 gigawatts (GW) in 2020 to approximately 760 GW cumulative installed capacity by 2035. Ground-mounted PV is expected to dominate future solar deployment and will require more than 3.5 million acres of land to meet annual demand projections (of nearly 45 GW) by 2030. However, various competing demands for land (e.g., agricultural production, conservation) and high land acquisition costs in specific locations could be challenges to meeting future PV demand solely with ground-mounted PV deployment. Floating photovoltaics (FPV) may be an alternative in locations where ground-mounted PV is not feasible and aid in reaching the nation's PV deployment and decarbonization goals. FPV is a newer siting approach in which a PV array is affixed to a floating apparatus and sited on a water body like a reservoir behind a dam. FPV systems may be stand-alone or co-located at new or existing hydroelectric facilities or pumped storage hydropower (PSH) facility reservoirs. Co-located FPV systems may or may not be operationally paired and work in tandem with the hydroelectric or PSH facility. This report provides novel analysis to understand the opportunities and challenges associated with developing stand-alone and co-located FPV projects on reservoirs in the United States. Specifically, the report explores potential environmental and energy benefits and environmental impacts associated with the siting, construction, and operation of FPV projects. The report also identifies and analyzes U.S. federal- and state-issued permits and authorizations required by federal laws to understand the licensing pathways and regulatory requirements for FPV projects sited on reservoirs licensed by the Federal Energy Regulatory Commission and on powered and non-powered reservoirs owned by the Bureau of Reclamation or U.S. Army Corps of Engineers.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipe lines, circuits, conduits. In addition, high voltage and flowing fluids are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

AquaPV: Regulatory and Environmental Considerations for Floating Photovoltaic Projects Located on Federally Controlled Reservoirs in the United States

To meet the nation's decarbonization goals, the U.S. Department of Energy's Solar Futures study forecasts that installed solar photovoltaic (PV) capacity must increase nearly tenfold, from 80 gigawatts (GW) in 2020 to approximately 760 GW cumulative installed capacity by 2035. Ground-mounted PV is expected to dominate future solar deployment and will require more than 3.5 million acres of land to meet annual demand projections (of nearly 45 GW) by 2030. However, various competing demands for land (e.g., agricultural production, conservation) and high land acquisition costs in specific locations could be challenges to meeting future PV demand solely with ground-mounted PV deployment. Floating photovoltaics (FPV) may be an alternative in locations where ground-mounted PV is not feasible and aid in reaching the nation's PV deployment and decarbonization goals. FPV is a newer siting approach in which a PV array is affixed to a floating apparatus and sited on a water body like a reservoir behind a dam. FPV systems may be stand-alone or co-located at new or existing hydroelectric facilities or pumped storage hydropower (PSH) facility reservoirs. Co-located FPV systems may or may not be operationally paired and work in tandem with the hydroelectric or PSH facility. This report provides novel analysis to understand the opportunities and challenges associated with developing stand-alone and co-located FPV projects on reservoirs in the United States. Specifically, the report explores potential environmental and energy benefits and environmental impacts associated with the siting, construction, and operation of FPV projects. The report also identifies and analyzes U.S. federal- and state-issued permits and authorizations required by federal laws to understand the licensing pathways and regulatory requirements for FPV projects sited on reservoirs licensed by the Federal Energy Regulatory Commission and on powered and non-powered reservoirs owned by the Bureau of Reclamation or U.S. Army Corps of Engineers.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

LINAC Electrical Cabinet - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, circuits, and conduits. In addition, high voltage and low conductivity water (LCW) piping are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model was developed for each cabinet and a Finite Element Analysis (FEA) was performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

Impingement cooling apparatus support structure and method of manufacture

An integrated combustor nozzle includes a combustion liner that extends radially between an inner liner segment and an outer liner segment. The combustion liner includes a forward end portion, an aft end portion, a first side wall, and a second side wall. The integrated combustor nozzle further includes an impingement cooling apparatus positioned within the cavity. The impingement cooling apparatus includes a flange. The impingement cooling apparatus further includes a plurality of impingement members that each extend from a respective opening defined in the flange to a respective closed end. Each impingement member defines a plurality of impingement apertures that direct air to impinge upon one of the first side wall and the second side wall. The impingement cooling apparatus further includes stand-offs extending from each impingement member of the plurality of impingement members. The stand-offs space apart each impingement member of the plurality of impingement members from surrounding surfaces.

Berry, Jonathan Dwight↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site.1,2,3 The underground transfer lines are used to transfer the waste between the tanks and other assets at the Hanford tank farm facilities. The transfer lines constructed before 1990 are pipe-in-pipe design with most of the lines having carbon steel carrier pipe and carbon steel encasements. The lines constructed after 1990 have a stainless-steel carrier with a carbon steel encasement. The carrier lines, which are in contact with the waste, provide a critical confinement function, while the encasements provide secondary containment to reduce the risk of a release and contamination to the environment. In 2022, a visual inspection of the annulus between the encasement and the carrier for one of the pre-1990 transfer lines revealed standing liquid in contact with the carrier pipe. Additionally, a significant build-up of corrosion products on the exterior of the carrier pipe and the interior of the encasement pipe was observed. To assess the extent of condition, borescope inspections were performed in the encasement space of additional transfer lines in the facility to provide a baseline. The inspection revealed that of the lines inspected, 29 had either moisture present or evidence that moisture had been present in the past (e.g., waterline corrosion where the pipe had been exposed to standing water). Additional inspections indicated several instances of pitting corrosion on the interior of the encasement and exterior the carrier transfer lines. An image of the carrier pipe with several pits is presented in Figure 1(a) and the profiled image of the transfer line section along with the pit depths are presented Figure 1(b). As seen in the figure, the deepest pit was 73 mils on the pipe section. These lines were designated as “do-not-use” until further compensatory actions are implemented to return the lines to service.

Shukla, Pavan K. [Savannah River National Laborato↗