Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Low-frequency acoustic propagation in high winds

The effect of refraction due to wind gradients on low-frequency acoustic signals over large propagation distances is considered. The results of an investigation of low-frequency propagation in high winds are presented and compared to normal mode theory for the downwind propagation case. In the downwind direction, the low-frequency signal was channeled close to the ground resulting in a divergence of 3 dB per doubling of propagation distance. Predictions of both ray tracing and normal mode theoretical models supported the downwind cylindrical spreading. In effect, the low-frequency noise signals propagate further in the presence of wind in the downwind direction. No low-frequency acoustic shadow zone was observed in the upwind direction.

Willshire, William L., Jr.↗

Smad Signaling Dynamics: Insights from a Parsimonious Model

The molecular mechanisms that transmit information from cell surface receptors to the nucleus are exceedingly complex; thus, much effort has been expended in developing computational models to understand these processes. A recent study on modeling the nuclear-cytoplasmic shuttling of Smad2-Smad4 complexes in response to transforming growth factor β (TGF-β) receptor activation has provided substantial insight into how this signaling network translates the degree of TGF-β receptor activation (input) into the amount of nuclear Smad2-Smad4 complexes (output). The study addressed this question by combining a simple, mechanistic model with targeted experiments, an approach that proved particularly powerful for exploring the fundamental properties of a complex signaling network. The mathematical model revealed that Smad nuclear-cytoplasmic dynamics enables a proportional, but time-delayed coupling between the input and the output. As a result, the output can faithfully track gradual changes in the input, while the rapid input fluctuations that constitute signaling noise are dampened out.

59 BASIC BIOLOGICAL SCIENCES↗

Control of a small working robot on a large flexible manipulator for suppressing vibrations: Development of a robust control law for flexible robot and it's stability analysis

Researchers developed a robust control law for slow motions for the accurate trajectory control of a flexible robot. The control law does not need larger velocity gains than position gains, which some researchers need to ensure the stability of a rigid robot. Initial experimentation for the Small Articulated Manipulator (SAM) shows that control laws that use smaller velocity gains are more robust to signal noise than the control laws that use larger velocity gains. Researchers analyzed the stability of the composite control law, the robust control for the slow motion, and the strain rate feedback for the fast control. The stability analysis was done by using a quadratic Liapunov function. Researchers found that the flexible motion of links could be controlled by relating the input force to the flexible signals which are sensed at the near tip of each link. The signals are contaminated by the time delayed input force. However, the effect of the time delayed input force can be reduced by giving a certain configuration to the SAM.

Soo, Han Lee↗

Effect of frequency detuning on Brillouin lasing in microcavities

We have theoretically investigated Brillouin lasing in microcavities in the case when the Brillouin shift and the intermode spacing of the microcavity do not coincide. It is shown that, despite the rise of the lasing threshold, a significant increase in the Brillouin signal intensity can be achieved in this case compared to the resonance one. A necessary condition for this effect is to select an optimal value of detuning of the pump radiation frequency from the frequency of the corresponding microcavity mode. The result of increasing the lasing threshold is also a narrowing of the Brillouin signal lasing range in the nonresonant case, which leads to a decrease in the signal noise level provided the detuning value is optimally selected. Analytical calculations are confirmed by the results of numerical modelling. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of a generalized least squares algorithm for infrasound beamforming with coherent background noise

Infrasonic signals of interest can occur during periods with persistent, coherent, background noise, which may be natural or anthropogenic. For high signal-to-noise (SNR) ratio transient signals, an ‘overprinting’ of the coherent background may occur, and the signal may still be detected. However, this approach fails for low SNR signals of interest, which may be obscured by coherent noise. An infrasound beamforming method based on generalized least squares (GLS) is investigated for detecting transient signals of interest in the presence of coherent and incoherent background noise. This approach relies on an estimate of the noise covariance, captured in a covariance matrix, to effectively null contributions to the array response from noisy directions of arrival. Synthetic array data is used to investigate the performance of the GLS beamformer compared to the Bartlett beamformer when coherent and incoherent backgrounds are present. Additionally, the effects of array element number and relative strength of the interfering signal on the GLS estimates is investigated. GLS empirical area under the curve estimates suggest that the beamformer can recover coherent power for a signal of interest lower in amplitude than the coherent background, but this effectiveness degrades more quickly with SNR for a four element array compared to a six or eight element infrasound array. Finally, infrasound from the Forensic Surface Experiment, a bolide signal observed at IMS array I37NO, and a volcanic signal recorded at the Alaska Volcano Observatory array ADKI are used to evaluate GLS performance on recorded data. A ten minute window was used to capture the background noise, and the coherent background signal was nulled in all three examples.

58 GEOSCIENCES↗

Distributed Temperature Sensing within a 19-pin Wire-Wrapped Fuel Bundle Model

It has always been difficult to measure local temperature and flow velocity within fuel bundle geometries because of their complex and compact layouts. High-resolution mapping of the flow field is especially challenging. High-resolution data is typically obtained using optical instruments but optical access to the interior regions of a bundle is severely limited. Velocity fields within fuel bundle models have been mapped with particle image velocimetry (PIV), an optical technique that employs lasers and cameras. Optical access to the bundle interior is obtained using transparent materials and matching the refractive index of the physical structures with that of the fluid. Testing is necessarily isothermal because refractive indices vary with temperature. However, the ultimate aim of such studies is understanding fluid dynamics and heat transfer within real reactors and so flow field mapping under nonisothermal conditions is of particular interest. Temperature fields can be mapped at high-resolution using laser-induced fluorescence (LIF). However, as an optical technique it is unsuitable for nonisothermal liquid flows. This is due to the same sort of optical distortion that restricts PIV. It is also unsuitable for opaque fluids and setups with restricted optical access. Fiber optic distributed temperature sensing (DTS) offers a high-resolution alternative that does not rely upon imaging. A single sensor can map temperature fields at resolutions far exceeding that achievable with conventional sensors such as thermocouples. Though fiber optic sensors cannot match the spatial resolution and bandwidth of LIF, they are suitable for nonisothermal and opaque flows. And though fibers are physical probes that perturb the flow, they can be strung across complex geometries to provide data in regions lacking the optical access necessary for techniques like LIF. Distributed temperature sensing has the potential to provide fuel bundle temperature data of a type that cannot be obtained with optical methods or conventional sensors. This paper reports on preliminary results of efforts to use fiber optic distributed temperature sensors in a fuel bundle model. We are conducting a feasibility study exploring implementation issues such as strain control in the mounting configuration and signal noise associated with flow-induced vibration. We describe here the setup and present preliminary data from our first phase testing with stagnant flow. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Building and Testing a Portable VLF Receiver

Unwanted emissions or signal noise is a major problem for VLF radio receivers. These can occur from man made sources such as power line hum, which can be prevalent for many harmonics after the fundamental 50 or 60 Hz AC source or from VLF radio transmissions such as LORAN, used for navigation and communications. Natural emissions can also be detrimental to the quality of recordings as some of the more interesting natural emissions such as whistlers or auroral chorus may be drowned out by the more common sferic emissions. VLF receivers must selectively filter out unwanted emissions and amplify the filtered signal to a record-able level without degrading the quality.

McLaughlin, Robert↗

Planck intermediate results

We present the NPIPE processing pipeline, which produces calibrated frequency maps in temperature and polarization from data from the Planck Low Frequency Instrument (LFI) and High Frequency Instrument (HFI) using high-performance computers. NPIPE represents a natural evolution of previous Planck analysis efforts, and combines some of the most powerful features of the separate LFI and HFI analysis pipelines. For example, following the LFI 2018 processing procedure, NPIPE uses foreground polarization priors during the calibration stage in order to break scanning-induced degeneracies. Similarly, NPIPE employs the HFI 2018 time-domain processing methodology to correct for bandpass mismatch at all frequencies. In addition, NPIPE introduces several improvements, including, but not limited to: inclusion of the 8% of data collected during repointing manoeuvres; smoothing of the LFI reference load data streams; in-flight estimation of detector polarization parameters; and construction of maximally independent detector-set split maps. For component-separation purposes, important improvements include: maps that retain the CMB Solar dipole, allowing for high-precision relative calibration in higher-level analyses; well-defined single-detector maps, allowing for robust CO extraction; and HFI temperature maps between 217 and 857 GHz that are binned into 0'.9 pixels (Nside = 4096), ensuring that the full angular information in the data is represented in the maps even at the highest Planck resolutions. The net effect of these improvements is lower levels of noise and systematics in both frequency and component maps at essentially all angular scales, as well as notably improved internal consistency between the various frequency channels. Based on the NPIPE maps, we present the first estimate of the Solar dipole determined through component separation across all nine Planck frequencies. The amplitude is (3366.6 ± 2.7) μK, consistent with, albeit slightly higher than, earlier estimates. From the large-scale polarization data, we derive an updated estimate of the optical depth of reionization of τ = 0.051 ± 0.006, which appears robust with respect to data and sky cuts. There are 600 complete signal, noise and systematics simulations of the full-frequency and detector-set maps. As a Planck first, these simulations include full time-domain processing of the beam-convolved CMB anisotropies. The release of NPIPE maps and simulations is accompanied with a complete suite of raw and processed time-ordered data and the software, scripts, auxiliary data, and parameter files needed to improve further on the analysis and to run matching simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-DE-207B-08: Towards Standardization of X-Ray Filters in Digital Mammography-Enabled Breast Tomosynthesis Systems

Purpose: In digital breast tomosynthesis (DBT) systems capable of digital mammography (DM), Al filters are used during DBT and K-edge filters during DM. The potential for standardizing the x-ray filters with Al, instead of K-edge filters, was investigated with intent to reduce exposure duration and to promote a simpler system design. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for K-edge filters (50µm Rh; 50µm Ag) were compared with Al filters of varying thickness. Two strategies for matching the HVT from K-edge and Al filtered spectra were investigated: varying the kVp for fixed Al thickness, or varying the Al thickness at matched kVp. For both strategies, Al filters were an order of magnitude thicker than K-edge filters. Hence, Monte Carlo simulations were conducted with the GEANT4 toolkit to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Al and K-edge filters. Results: Results show the potential for replacing currently used Kedge filters with Al. For fixed Al thickness (700µm), ±1 kVp and +(1–3) kVp change, matched HVT of Rh and Ag filtered spectra. At matched kVp, Al thickness range (650,750)µm and (750,860)µm matched the HVT from Rh and Ag filtered spectra. Photon fluence/mAs with Al filters were 1.5–2.5 times higher, depending on kVp and Al thickness, compared to K-edge filters. Although Al thickness was an order higher than K-edge filters, neither the SPR nor the scatter PSF differed from K-edge filters. Conclusion: The use of Al filters for digital mammography is potentially feasible. The increased fluence/mAs with Al could decrease exposure duration for the combined DBT+DM exam and simplify system design. Effect of x-ray spectrum change due to Al filtration on radiation dose, signal, noise, contrast and related metrics are being investigated. Funding support: Supported in part by NIH R21CA176470 and R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

A multi-site resting state fMRI study on the amplitude of low frequency fluctuations in schizophrenia

Background: This multi-site study compares resting state fMRI amplitude of low frequency fluctuations (ALFF) and fractional ALFF (fALFF) between patients with schizophrenia (SZ) and healthy controls (HC). Methods: Eyes-closed resting fMRI scans (5:38 min; n = 306, 146 SZ) were collected from 6 Siemens 3T scanners and one GE 3T scanner. Imaging data were pre-processed using an SPM pipeline. Power in the low frequency band (0.01–0.08 Hz) was calculated both for the original pre-processed data as well as for the pre-processed data after regressing out the six rigid-body motion parameters, mean white matter (WM) and cerebral spinal fluid (CSF) signals. Both original and regressed ALFF and fALFF measures were modeled with site, diagnosis, age, and diagnosis × age interactions. Results: Regressing out motion and non-gray matter signals significantly decreased fALFF throughout the brain as well as ALFF in the cortical edge, but significantly increased ALFF in subcortical regions. Regression had little effect on site, age, and diagnosis effects on ALFF, other than to reduce diagnosis effects in subcortical regions. There were significant effects of site across the brain in all the analyses, largely due to vendor differences. HC showed greater ALFF in the occipital, posterior parietal, and superior temporal lobe, while SZ showed smaller clusters of greater ALFF in the frontal and temporal/insular regions as well as in the caudate, putamen, and hippocampus. HC showed greater fALFF compared with SZ in all regions, though subcortical differences were only significant for original fALFF. Conclusions: SZ show greater eyes-closed resting state low frequency power in frontal cortex, and less power in posterior lobes than do HC; fALFF, however, is lower in SZ than HC throughout the cortex. These effects are robust to multi-site variability. Regressing out physiological noise signals significantly affects both total and fALFF measures, but does not affect the pattern of case/control differences.

59 BASIC BIOLOGICAL SCIENCES↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗

Coherent beam combining of pulsed fibre amplifiers with active phase control

Coherent beam combining of pulsed fibre lasers is a promising method for power scaling while simultaneously maintaining good beam quality. We propose and demonstrate a scalable architecture for coherent beam combining of all-fibre pulsed amplifiers with active phase control using the stochastic parallel gradient descent (SPGD) algorithm. A low-pass filter is introduced to eliminate the fluctuation of the metric function caused by pulsed lasers and to extract the exact phase noise signal. Active control is thereby based on the SPGD algorithm, resulting in stable coherent beam combining at the receiving plane even in a turbulent environment. Experimental results show that the fringe visibility of the long exposure pattern increases from 0 to 0.4, and the power encircled in the main-lobe increases by 1.6 times when the system evolves from the open-loop phase-locking scheme to the closed-loop scheme. This architecture can be easily scaled up to a higher power by increasing the number of amplifying channels and the power of a single amplifier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compressed sensing X-ray camera with a multilayer architecture

Recent advances in compressed sensing theory and algorithms offer new possibilities for high-speed X-ray camera design. In many CMOS cameras, each pixel has an independent on-board circuit that includes an amplifier, noise rejection, signal shaper, an analog-to-digital converter (ADC), and optional in-pixel storage. When X-ray images are sparse, i.e., when one of the following cases is true: (a.) The number of pixels with true X-ray hits is much smaller than the total number of pixels; (b.) The X-ray information is redundant; or (c.) Some prior knowledge about the X-ray images exists, sparse sampling may be allowed. In this work, we first illustrate the feasibility of random on-board pixel sampling (ROPS) using an existing set of X-ray images, followed by a discussion about signal to noise as a function of pixel size. Next, we describe a possible circuit architecture to achieve random pixel access and in-pixel storage. The combination of a multilayer architecture, sparse on-chip sampling, and computational image techniques, is expected to facilitate the development and applications of high-speed X-ray camera technology.

47 OTHER INSTRUMENTATION↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Extracting a mixing parameter from 2D radiographic imaging of variable-density turbulent flow

We extract a suitably averaged fluctuating density from the two-dimensional radiographic image of a flow. The X-ray attenuation is given by the Beer–Lambert law which exponentially damps the incident beam intensity by a factor proportional to the density, opacity and thickness of the target. By making reasonable assumptions for the mean density, opacity and effective thickness of the target flow, we estimate the density fluctuation contribution to the attenuation. The extracted density fluctuations averaged across the thickness of the flow in the direction of the beam may be used to form the density–specific-volume correlation $b$. In a statistical description of variable-density turbulence, $b$ quantifies the degree of mixedness. The ability to extract a measure of mixedness from experimental data would be a powerful tool that could be used in the validation of mix models. The scheme proposed is tested for DNS data computed for variable density buoyancy-driven mixing. We quantify the deficits in the extracted value of $b$ due to target thickness, Atwood number and modeled signal noise. This analysis justifies using the proposed scheme to infer the mix parameter from thin targets at moderate to low Atwood numbers. Furthermore, to illustrate how the scheme might be used in a practical problem, we demonstrate its application to a radiographic image of counter-shear flow obtained from experiments at the National Ignition Facility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding the bias introduced in quantum dot blinking using change point analysis

Quantum dots are semiconductor crystals that are less than 100 nanometers in size; that is, between 1 billionth and 100 billionths of a meter. They can be composed of one semiconductor material or a core of one semiconductor surrounded by a shell of another. The quantum dots studied in this work consisted of a cadmium selenide core surrounded by a cadmium sulfide shell. When a quantum dot is illuminated with light, some of it can be absorbed and excites the quantum dot to a higher energy state. To relax back down to its resting state, light can be emitted in the form of fluorescence. The nature of the fluorescence that is emitted from a single quantum dot differs from that which is emitted from a bulk sample (usually a solid film or a solution of quantum dots). While in bulk samples the fluorescence over time fluctuates randomly about some average, maintaining a continuous average intensity, single quantum dot fluorescence switches between two or more intensities. This phenomenon is referred to as quantum dot blinking, and its origin is of significant relevance to solar cell, light emitting diode and biological tracking applications. Quantum dot blinking can be studied by exciting an isolated quantum dot with light and recording the ensuing fluorescence using sensitive detectors. This is done over many minutes, resulting in a fluorescence intensity (in counts per second) versus time trajectory. These trajectories must be further analyzed in order to understand the nature of the blinking behavior. Conventionally, a bin and threshold analysis is used, whereby the arrival times of fluorescent photons are binned to reduce the signal noise, and a threshold is used to separate the trajectory into periods of high and low fluorescence. In this study, the effects of bin size and threshold on the blinking kinetics were investigated, and the assumption that there is only one bright and one dark state was tested. To do so, a statistically rigorous method called change point analysis was needed which does not require binning and which can determine the number of intensity levels present. Blinking in 17 quantum dots was studied using both analysis methods. The primary parameter that was compared between the two methods is called a truncation time. Increasing the bin size was found to generally lead to a larger truncation time while increasing the threshold always decreased the truncation time. Using the change point analysis method, 12 out of 17 quantum dots were found to exhibit more than two intensity levels. Lastly, the assumption that only two intensity levels exist was found to significantly affect the blinking statistics: when individual levels were combined into one bright level, the truncation time would increase. The change point analysis method was found to be more suitable for studying multilevel blinking in quantum dots than the conventional bin and threshold method, since the effects of binning and thresholding can be alleviated and the two-level assumption relaxed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗