Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Single Center Experience with the AngioVac Aspiration System

PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and the patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Stenting for Portal Biliopathy with Jaundice

Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Management of Neobladder Variceal Bleeding

Hematuria from a neobladder can occur due to a variety of pathologies including tumors, stones, and fistulas. Variceal bleeding in a neobladder is a very rare condition with only one case reported in literature. We present a case of a patient with cirrhosis and portal hypertension and an ileocolic orthotopic neobladder presenting with hematuria. Computed tomographic angiography showed dilated varices around the neobladder which were successfully embolized. To the best of our knowledge, this is the first report case of variceal bleeding in a neobladder successfully managed with the combination of TIPS (transjugular intrahepatic portosystemic shunt) procedure and embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Ultrasound-Guided Axillary Brachial Plexus Block for Analgesia During Percutaneous Transluminal Angioplasty for Dialysis Access

PurposeTo evaluate the efficacy and safety of ultrasound (US)-guided axillary brachial plexus block (ABPB) for analgesia during percutaneous transluminal angioplasty (PTA) for dialysis access.Subjects and MethodsTwenty-one patients who underwent PTA for stenotic dialysis access shunts and who had previous experience of PTA without sedation, analgesia, and anesthesia were included. The access type in all patients was native arteriovenous fistulae in the forearm. Two radiologists performed US-guided ABPB for the radial and musculocutaneous nerves before PTA. The patients’ pain scores were evaluated using a visual analog scale (VAS) after PTA, and these were compared with previous sessions without US-guided ABPB. The patient’s motor/sensory paralysis after PTA was also examined.ResultsThe mean time required to achieve US-guided ABPB was 8 min. The success rate of this procedure was 100 %, and there were no significant complications. All 21 patients reported lower VAS with US-guided ABPB as compared to without the block (p < 0.01). All patients expressed the desire for an ABPB for future PTA sessions, if required. Transient motor paralysis occurred in 8 patients, but resolved in all after 60 min.ConclusionUS-guided ABPB is feasible and effective for analgesia in patients undergoing PTA for stenotic dialysis access sites.Level of EvidenceLevel 4 (case series).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Occluded Retrograde Transvenous Obliteration of a Gastric Vascular Malformation: An Innovative Approach to Treatment of a Rare Condition

Arteriovenous malformations (AVMs) are a high-flow form of a vascular malformation, which can be found anywhere in the body. While historically treated surgically, a multidisciplinary approach utilizing multiple specialties and treatment modalities is now commonly employed. In order to effectively treat an AVM, the nidus must be targeted and eradicated, which can be done via multiple approaches. We present the case of a 43-year-old male with a gastric wall AVM, which was initially incompletely treated using a percutaneous transarterial approach. The gastric AVM was noted to have dominant drainage through a gastrorenal shunt; therefore, Balloon-occluded Retrograde Transvenous Obliteration (BRTO) was utilized to eradicate the AVM nidus. This case illustrates the utility of Interventional Radiology, specifically BRTO, as another treatment option for challenging AVMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Hepatic Arterial Injury Related to Percutaneous Transhepatic Portal Intervention

PurposeTo assess the usefulness of transcatheter arterial embolization (TAE) for the hepatic arterial injury related to percutaneous transhepatic portal intervention (PTPI).Materials and MethodsFifty-four patients, 32 males and 22 females with a median age of 68 years (range 43–82 years), underwent PTPI. The procedures consisted of 33 percutaneous transhepatic portal vein embolizations, 19 percutaneous transhepatic variceal embolizations, and 2 percutaneous transhepatic portal venous stent placements. Two patients with gastric varices underwent percutaneous transhepatic variceal embolization twice because of recurrence. Therefore, the total number of procedures was 56. Among them, hepatic arterial injury occurred in 6 PTPIs in 5 patients, and TAE was performed. We assessed technical success, complications related to TAE, and clinical outcome. Technical success was defined as the disappearance of findings due to hepatic arterial injury on digital subtraction angiography.ResultsAs hepatic arterial injuries, 4 extravasations and 2 arterioportal shunts developed. All TAEs were performed successfully. The technical success rate was 100 %. Complication of TAE occurred in 5 of 6 TAEs; 3 were focal liver infarction, not requiring further treatment, and 2 were biloma that required percutaneous drainage. Five TAEs in 4 patients were performed immediately after the PTPI, and these 4 patients were alive. However, one TAE was performed 10 h later, and the patient died due to multiple organ failure 2 months later although TAE was successful.ConclusionTAE is a useful treatment for hepatic arterial injury related to PTPI. However, it should be performed at an early stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bilateral Arterial Embolization of the Prostate Through a Single Prostatic Artery: A Case Series

Peri-prostatic shunts are frequent during PAE, carrying the risk of non-target embolization of penis/corpus cavernosum or rectum but also the potential advantage to irrigate the contralateral lobe. Sometimes, bilateral embolization is impossible, carrying the risk of limited clinical success. The possibility to reach contralateral prostatic territory from the ipsilateral prostatic artery (PA) and embolize it via peri/intra-prostatic anastomoses could be of interest in this situation. We describe a series of three consecutive patients (among 89 consecutive patients treated by PAE for symptomatic BPH) who underwent successful embolization of both prostatic lobes through catheterization of a PA on only one side. All patients had clinical success after a mean follow-up of 3.3 months. Dosimetry of these three procedures indicates that there may be radiation dose savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No Increased Mortality After TIPS Compared with Serial Large Volume Paracenteses in Patients with Higher Model for End-Stage Liver Disease Score and Refractory Ascites

Purpose: To compare survival after transjugular intrahepatic portosystemic shunt (TIPS) creation versus serial large volume paracenteses (LVP) in patients with refractory ascites and higher Model for End-Stage Liver Disease (MELD) scores. Materials and Methods: In this retrospective study, from 1/1/2013 to 10/1/2018, 478 patients (294 male; mean age 58, range 23–89) underwent serial LVP (n = 386) or TIPS (n = 92) for ascites. Propensity-matched cohorts were constructed based on age, MELD, Charlson comorbidity index, varices, and hepatic encephalopathy. Survival was analyzed using a Cox proportional hazards model in which MELD score and TIPS were treated as time-dependent covariates. An interaction term was used to assess the impact of TIPS versus serial LVP on survival as a function of increasing MELD. Results: In the overall patient sample, higher MELD score predicted worse survival after either serial LVP or TIPS [hazard ratio (HR) = 1.13; p < 0.001], but there was no significant interaction between TIPS and higher MELD score conferring worse survival (HR = 1.01; p = 0.55). In 92 propensity-matched serial LVP and 92 TIPS patients, higher MELD score predicted worse survival after either serial LVP or TIPS (HR = 1.19; p < 0.001), but there was no significant survival interaction between TIPS and higher MELD (HR = 0.97; p = 0.22). In 30 propensity-matched serial LVP patients and 30 TIPS patients with baseline MELD greater than 18, TIPS did not predict worse survival (HR = 0.97; p = 0.94). Conclusion: Higher MELD predicts poorer survival after either serial LVP or TIPS, but TIPS creation is not associated with worse survival compared to serial LVP in patients with higher MELD scores Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes After Transarterial Embolization of Neuroendocrine Tumor Liver Metastases Using Spherical Particles of Different Sizes

Purpose: To evaluate initial response and overall survival of neuroendocrine tumor (NET) liver metastases initially treated with transarterial embolization (TAE) using spherical particles of different sizes. Methods: A single-institution retrospective review was performed of 160 patients with NET liver metastases initially treated with TAE using < 100 µm (n = 77) or only ≥ 100 µm (n = 83) spherical particles. For each patient, we evaluated: initial response by mRECIST, time to progression, overall survival, complications, primary site, tumor grade and degree of differentiation, volume of liver disease, extrahepatic disease, NET-related symptoms, comorbidities, Child–Pugh score, performance status, lobar versus selective embolization, and arteriovenous shunting. Results: Initial response was higher for TAE using particles < 100 versus TAE using only particles ≥ 100 μm (64 vs 42%, p = 0.007). Multivariate logistic regression showed that use of particles < 100 μm and liver < 50% replaced with tumor were independent predictors of a better initial response rate. There was no difference in major or minor complications between the two particle size groups. Median overall survival after TAE was 55 months for well- to moderately differentiated NET and 13 months for poorly differentiated or undifferentiated NET. There was no significant difference in survival between TAE patients treated with < 100 versus only ≥ 100-μm particles. Conclusion: NET patients treated with TAE using particles < 100 μm had better initial response, but the same overall survival, compared to TAE using only particles ≥ 100 μm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Endovascular Iliocaval Reconstruction Using Polytetrafluoroethylene Stent-Graft Placement for the Treatment of Inferior Vena Cava Resection

Resection of the inferior vena cava (IVC) is a rare surgical technique that is occasionally combined with nephrectomy in the setting of renal malignancy with intravascular tumor extension. While this may be fairly well tolerated in some patients due to extensive collateralization in the venous system, there is a clear potential for lower extremity venous insufficiency and deep vein thrombosis (DVT). This report describes a patient who underwent right nephrectomy and segmental IVC resection from the subhepatic space to the iliac confluence, which was complicated by profoundly symptomatic lower extremity DVT and gastrointestinal hemorrhage due to system-to-portal shunting. After performing sharp recanalization through the retroperitoneum, iliocaval reconstruction was accomplished utilizing covered stent-grafts, with complete resolution of symptoms.Level of Evidence Case Report, Level 5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite

PurposeWe sought to evaluate patient radiation exposure during complex liver interventional procedures performed with newer angiography equipment.Materials and MethodsWe conducted a retrospective study of transjugular intrahepatic portosystemic shunt (TIPS) creations and liver tumor embolizations performed in our new angiography suite (Discovery IGS740, GE Healthcare). T tests were used to compare air kerma-area product (P{sub KA}) and reference plane air kerma (K{sub a,r}) in the new room versus data from historical rooms and previous studies (including the RAD IR study). Results were expressed as medians [interquartile ranges (Q1, Q3)].ResultsFrom February 2015 to June 2016, 134 complex liver interventional procedures were performed in the new room, including 14 TIPS creations, 60 hepatic tumor arterial embolizations (HAEs), 26 Y90 mappings (Y90m), and 34 Y90 radioembolizations (Y90). K{sub a,r} (Gy) values were as follows: TIPS, 0.65 (0.24, 1.15); HAE, 0.89 (0.49, 1.49); Y90m, 0.54 (0.38, 0.94); Y90, 0.46 (0.21, 1.06). P{sub KA} (Gy·cm{sup 2}) values were as follows: TIPS, 148.2 (66.7, 326.5); HAE, 142.6 (88, 217.8); Y90m, 148.3 (98.2, 247); Y90, 90.8 (43.9, 161.5). K{sub a,r} and P{sub KA} were lower in the new room than in historical rooms [K{sub a,r} and P{sub KA} reductions: TIPS, 58 and 49%; HAE, 31 and 39%; Y90m, 58 and 52%; Y90, 49 and 56% (p < 0.05)] and versus the RAD IR study [K{sub a,r} and P{sub KA} reductions: TIPS, 64 and 43%; HAE, 26 and 40% (p < 0.05)].ConclusionsUsing the latest technology and image processing tools enables significant reduction in radiation exposure during complex liver interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interrelation of surface tension, optical turbidity, and color of operational transformer oils

Measurements of the acidity, optical turbidity, surface tension, and color of transformer oil from 54 power transformers, autotransformers, and shunt reactors are reported. Changes in surface tension, optical turbidity, and color are found to obey adequate linear correlations, while the acidity has no correlation with any of these properties. Numerical criteria for the maximum permissible state (quality) of the oil with respect to optical turbidity and color are obtained. Recommendations to operating staff are provided for cases in which the criteria for optical turbidity and color are exceeded.

42 ENGINEERING↗

Mapping TES Temperature Sensitivity and Current Sensitivity as a Function of Temperature, Current, and Magnetic Field with IV Curve and Complex Admittance Measurements

We have specialized astronomical applications for X-ray microcalorimeters with superconducting transition edge sensors (TESs) that require exceptionally good TES performance, but which operate in the small-signal regime. We have therefore begun a program to carefully characterize the entire transition surface of TESs with and without the usual zebra stripes to see if there are reproducible local “sweet spots” where the performance is much better than average. These measurements require precise knowledge of the circuit parameters. Here, we show how the Shapiro effect can be used to precisely calibrate the value of the shunt resistor. We are also investigating the effects of stress and external magnetic fields to better understand reproducibility problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interferometric studies of the electron density dynamics at the periphery of a micropinch discharge

Results are presented from experimental studies of the electron density dynamics at the periphery of a low-inductance vacuum spark. The measurements were performed using a newly developed homodyne quadrature interferometer possessing fairly high dynamic range and performance. The experiments demonstrated the presence of a plasma with an electron density of n{sub e} {>=} 10{sup 18} cm{sup -3} at the periphery of the discharge gap. The radial electron density distribution was shown to have a pronounced tubular structure. The relatively high values of the peripheral electron density indicate that the process of pinching can be substantially affected by shunt currents flowing at the discharge periphery.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical and experimental studies of Schottky diodes that use aligned arrays of single-walled carbon nanotubes

We present theoretical and experimental studies of Schottky diodes that use aligned arrays of single-walled carbon nanotubes. A simple physical model, taking into account the basic physics of current rectification, can adequately describe the single-tube and array devices. We show that for as-grown array diodes, the rectification ratio, defined by the maximum-to-minimum-current-ratio, is low due to the presence of metallic-single-walled nanotube (SWNT) shunts. These tubes can be eliminated in a single voltage sweep resulting in a high rectification array device. Further analysis also shows that the channel resistance, and not the intrinsic nanotube diode properties, limits the rectification in devices with channel length up to 10 μm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

The novel zinc cluster regulator Tog1 plays important roles in oleate utilization and oxidative stress response in Saccharomyces cerevisiae

Highlights: • TOG1 deletion results in defective growth on non-fermentable carbon sources. • Removal of TOG1 sensitizes cells to oxidative stress. • Tog1 directly binds and activates expression of oleate utilizing genes. • The Δtog1 cells display reduced peroxisomal content in oleate culture. • S. cerevisiae zinc cluster Tog1 is a novel activator of oleate utilization. - Abstract: Many zinc cluster proteins have been shown to play a role in the transcriptional regulation of glucose-repressible genes during glucose exhaustion and diauxic shift. Here, we studied an additional member of this family called Yer184c (herein called Tog1) for transcriptional regulator of oleate. Our results showed that a Δtog1 strain displays impaired growth with several non-fermentable carbons. Tog1 is also implicated in oxidative stress tolerance. Importantly, during the glucose–oleate shift, combined results from quantitative real time-PCR and chromatin immunoprecipitation (ChIP) experiments showed that Tog1 acts as a direct activator of oleate utilizing genes, encoded key enzymes in β-Oxidation and NADPH regeneration (POX1, FOX2, POT1 and IDP2), the glyoxylate shunt (MLS1 and ICL1), and gluconeogenesis (PCK1 and FBP1). A transmission electron microscopy (TEM) analysis of the Δtog1 strain assayed with oleate also revealed a substantial decrease in peroxisome abundance that is vital for fatty acid oxidation. Overall, our results clearly demonstrated that Tog1 is a newly characterized zinc cluster regulator that functions in the complex network of non-fermentable carbon metabolism in Saccharomycescerevisiae.

60 APPLIED LIFE SCIENCES↗