Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHEATH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Development of a spectroscopic diagnostic tool for electric field measurements in IShTAR (Ion cyclotron Sheath Test ARrangement)

IShTAR, Ion cyclotron Sheath Test ARrangement, is a linear device dedicated to the investigation of the edge plasma–ICRF (Ion Cyclotron Range of Frequencies) antenna interactions in tokamak edge-like conditions and serves as a platform for a diagnostic development for measuring the electric fields in the vicinity of ICRF antennas. We present here our progress in the development of an optical emission spectroscopy method for measuring the electric fields which concentrates on the changes in the helium spectral line profiles introduced by the external electrical field, i.e., the Stark effect. To be able to fully control the operating parameters, at the first stage of the study, the measurements are conducted on a planar electrode installed in the centre of the plasma column in IShTAR’s helicon plasma source. At the second stage, the measurements are performed in the vicinity of IShTAR’s ICRF antenna.

Kostic, Ana↗

DISCOVERY OF SMOOTHLY EVOLVING BLACKBODIES IN THE EARLY AFTERGLOW OF GRB 090618: EVIDENCE FOR A SPINE–SHEATH JET?

GRB 090618 is a bright gamma-ray burst (GRB) with multiple pulses. It shows evidence of thermal emission in the initial pulses as well as in the early afterglow phase. Because high-resolution spectral data from the Swift/X-ray Telescope (XRT) are available for the early afterglow, we investigate the shape and evolution of the thermal component in this phase using data from the Swift/Burst Alert Telescope (BAT), the Swift/XRT, and the Fermi/Gamma-ray Burst Monitor detectors. An independent fit to the BAT and XRT data reveals two correlated blackbodies with monotonically decreasing temperatures. Hence, we investigated the combined data with a model consisting of two blackbodies and a power law (2BBPL), a model suggested for several bright GRBs. We elicit the following interesting features of the 2BBPL model: (1) the same model is applicable from the peak of the last pulse in the prompt emission to the afterglow emission, (2) the ratio of temperatures and the fluxes of the two blackbodies remains constant throughout the observations, (3) the blackbody temperatures and fluxes show a monotonic decrease with time, with the BB fluxes dropping about a factor of two faster than that of the power-law (PL) emission, and (4) attributing the blackbody emission to photospheric emissions, we find that the photospheric radii increase very slowly with time, and the lower-temperature blackbody shows a larger emitting radius than that of the higher-temperature blackbody. We find some evidence that the underlying shape of the nonthermal emission is a cutoff power law rather than a PL. We sketch a spine–sheath jet model to explain our observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-dependent collisional radiative modeling of tungsten in the magnetic sheath for erosion diagnosis

Abstract Tungsten is the material of choice for the divertors in ITER, SPARC and future fusion reactors. Accurate diagnosis of tungsten erosion and migration is important for first wall life time, slag production and core performance. The addition of a magnetic presheath requires time-dependent collisional radiative effects to be included for accurate neutral tungsten collisional radiative modeling. Gross erosion measurements could be modified by a factor of 10 due to the inclusion of time-dependent effects for ITER relevant divertor conditions. A simple sputtering model and sheath density model are developed to investigate time-dependent collisional radiative effects. Neutral tungsten spectral lines populated from different metastable levels depend on model parameters leading to potential spectroscopic diagnostics of plasma parameters. Electron temperatures inferred from spectroscopic line ratios are in agreement with Langmuir probe measurements in the Compact Toroidal Hybrid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CDK4/6 inhibition enhances SHP2 inhibitor efficacy and is dependent upon RB function in malignant peripheral nerve sheath tumors

Malignant peripheral nerve sheath tumors (MPNSTs) are highly aggressive soft tissue sarcomas with limited treatment options, and new effective therapeutic strategies are desperately needed. We observe antiproliferative potency of genetic depletion of PTPN11 or pharmacological inhibition using the SHP2 inhibitor (SHP2i) TNO155. Our studies into the signaling response to SHP2i reveal that resistance to TNO155 is partially mediated by reduced RB function, and we therefore test the addition of a CDK4/6 inhibitor (CDK4/6i) to enhance RB activity and improve TNO155 efficacy. In combination, TNO155 attenuates the adaptive response to CDK4/6i, potentiates its antiproliferative effects, and converges on enhancement of RB activity, with greater suppression of cell cycle and inhibitor-of-apoptosis proteins, leading to deeper and more durable antitumor activity in in vitro and in vivo patient-derived models of MPNST, relative to either single agent. Overall, our study provides timely evidence to support the clinical advancement of this combination strategy in patients with MPNST and other tumors driven by loss of NF1.

60 APPLIED LIFE SCIENCES↗

Plasma Parameters Controlled by a Movable Ion Sheath

It is shown that plasma parameters, such as the electron density, electron temperature, and plasma potential, in multidipole discharge plasma can be controlled by a negatively biased movable metal plate. Here, plasma is produced in the target region by a flux of energetic electrons coming from the source region of a double plasma device. Further, the thickness of the ion sheath formed in front of the biased metal plate varies depending on its axial position inside the cage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient Adjustments for Metal-Sheathed Thermocouples on Metal Plates (Shrouds)

This report provides guidance on how to adjust temperature measurements from mineral-insulated, metal-sheathed (MIMS) thermocouples (TCs) mounted on metal plates to correct for slow transient response. This information is needed so that more accurate transient temperature measurements can be made. These more accurate temperature measurements are of benefit for both qualification of hardware and as data sets for model validation. The approach was to use a relatively simple first order adjustment to the MIMS TC reading, as compared to a more accurate metal plate temperature measurement. MIMS TCs are used to improve reliability. Results from four data sets were analyzed to determine the time constraint; an overall average of 5.0 s was obtained.

42 ENGINEERING↗

Multiplexing core & sheath extrusion system development for additive manufacturing for inner-bead multi-material capability

Single-feed polymer extruders are widely used in large-format additive manufacturing (AM) systems; however, the increasing demand for multi-material functionality within a single part has driven significant innovation in this field. One approach involves robotic pick-and-place operations, while another explores mechanical switching of feed lines during extrusion. Although robotic pick-and-drop systems offer flexibility, they introduce longer layer times during material changes, which can negatively affect the structural integrity of the part. On the other hand, mechanical feed switching causes delays in material transitions, as the existing material must be flushed before the new material emerges from the nozzle. This poses particular challenges for smaller or more intricate parts. In this study we are developing a unique multiplexing extrusion system with core & sheath nozzle that combines two extruders via co-extrusion. This allows for a unique inside and outside inner-bead (i.e., within the same bead) multi-material capability. We believe that this technology will allow for combining neat and filled materials, ductile and stronger materials, and many other combinations to address the problems aforementioned above and disrupt the AM technology creating new opportunities and opening application areas.

Tekinalp, Halil [ORNL]↗

Thoriated tungsten tube provides improved high temperature thermocouple sheath

Thermocouple tubing of thoriated tungsten with a very fine grain structure produces a small-diameter sheath capable of operating up to 5000 degrees R in a hydrogen and graphite environment. This tubing remains ductile and resists both grain growth and carbiding even after prolonged exposure to temperature.

Zellner, G. J.↗