Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Multiplexed operation of a micromachined ultrasonic droplet ejector array

A dual-sample ultrasonic droplet ejector array is developed for use as a soft-ionization ion source for multiplexed mass spectrometry (MS). Such a multiplexed ion source aims to reduce MS analysis time for multiple analyte streams, as well as allow for the synchronized ejection of the sample(s) and an internal standard for quantitative results and mass calibration. Multiplexing is achieved at the device level by division of the fluid reservoir and separating the active electrodes of the piezoelectric transducer for isolated application of ultrasonic wave energy to each domain. The transducer is mechanically shaped to further reduce the acoustical crosstalk between the domains. Device design is performed using finite-element analysis simulations and supported by experimental characterization. Isolated ejection of {approx}5 {mu}m diameter water droplets from individual domains in the micromachined droplet ejector array at around 1 MHz frequency is demonstrated by experiments. The proof-of-concept demonstration using a dual-sample device also shows potential for multiplexing with larger numbers of analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KBase Narrative - Atacama Trench & Sn Clemente 2018 cruise Metagenomes -Decontamination through Metagenomic Fractionation and analysis of Metabolic Potential-

Deep-sea microbiomes sampled with traditional or pressure-retaining instrumentation A fundamental property of life in the sea is that with increasing depth must come increased adaptation to elevated hydrostatic pressures. This project aims to assess technology for the accurate characterization of microbial biodiversity and biochemistry at greater depths, and validate its use in some of the deepest and least-explored waters in the Ocean: Hadal Trench. Compared to the 0.1 megapascal (MPa) of surface waters, organisms inhabiting at the average depth of the Ocean (3800 m) have to deal with pressures of 38 MPa (5,500 psi). The effects of these high pressure have been most thoroughly investigated in microorganisms, where it has been found to affect membrane integrity and transport, cytoskeletal assembly and both DNA and protein synthesis. We will explore the diversity and activity of microorganisms from 2000 m to >8,000 m depths within the highly productive water column of hadal trenches, comparing seawater samples obtained with and without substantial pressure changes during recovery. A pressure retaining device was used to sample the microbial communities of the watercolumn with reduced decompression during retreival (Peoples et. al., 2019). References: Peoples LM, Norenberg M, Price D, McGoldrick M, Novotny M, Bochdansky A, Bartlett DH. A full-ocean-depth rated modular lander and pressure-retaining sampler capable of collecting hadal-endemic microbes under in situ conditions. Deep Sea Research Part I: Oceanographic Research Papers. 2019 Jan 1;143:50-7.

Plominsky, Alvaro M.↗

KBase Narrative - Atacama Trench & Sn Clemente 2018 cruise Metagenomes -Sequence quality filtration & Assembly-

Deep-sea microbiomes sampled with traditional or pressure-retaining instrumentation A fundamental property of life in the sea is that with increasing depth must come increased adaptation to elevated hydrostatic pressures. This project aims to assess technology for the accurate characterization of microbial biodiversity and biochemistry at greater depths, and validate its use in some of the deepest and least-explored waters in the Ocean: Hadal Trench. Compared to the 0.1 megapascal (MPa) of surface waters, organisms inhabiting at the average depth of the Ocean (3800 m) have to deal with pressures of 38 MPa (5,500 psi). The effects of these high pressure have been most thoroughly investigated in microorganisms, where it has been found to affect membrane integrity and transport, cytoskeletal assembly and both DNA and protein synthesis. We will explore the diversity and activity of microorganisms from 2000 m to >8,000 m depths within the highly productive water column of hadal trenches, comparing seawater samples obtained with and without substantial pressure changes during recovery. A pressure retaining device was used to sample the microbial communities of the watercolumn with reduced decompression during retreival (Peoples et. al., 2019). References: Peoples LM, Norenberg M, Price D, McGoldrick M, Novotny M, Bochdansky A, Bartlett DH. A full-ocean-depth rated modular lander and pressure-retaining sampler capable of collecting hadal-endemic microbes under in situ conditions. Deep Sea Research Part I: Oceanographic Research Papers. 2019 Jan 1;143:50-7.

Plominsky, Alvaro M.↗

Microwave assisted centrifuge and related methods

Centrifuge samples may be exposed to microwave energy to heat the samples during centrifugation and to promote separation of the different components or constituents of the samples using a centrifuge device configured for generating microwave energy and directing the microwave energy at a sample located in the centrifuge.

Meikrantz, David H↗

Concepts for collection of aerosols in Titan's atmosphere

This paper considers design of instruments for collection of aerosols during entry in Titan's atmosphere. Major constraints on designs are small sample collection time, low aerosol column density, and the need to collect 1-10 micrograms of aerosol for gas chromatographic analysis. Thus, it is important to maximize aerosol collection through collector design, which includes consideration of various types of collectors, and maximizing the collection efficiency of a given type of collector. Sampling systems discussed include inertial impactors, filters, electrostatic devices, and multistage instruments. Aerosol sampling is reviewed in the context of high-altitude (200-70 km) and low-altitude (60-30 km) regions of Titan's atmosphere.

Oberbeck, Verne R.↗

Compact spherical neutron polarimeter using high-T{sub c} YBCO films

We describe a simple, compact device for spherical neutron polarimetry measurements at small neutron scattering angles. The device consists of a sample chamber with very low (<0.01 G) magnetic field flanked by regions within which the neutron polarization can be manipulated in a controlled manner. This allows any selected initial and final polarization direction of the neutrons to be obtained. We have constructed a prototype device using high-T{sub c} superconducting films and mu-metal to isolate regions with different magnetic fields and tested device performance in transmission geometry. Finite-element methods were used to simulate the device’s field profile and these have been verified by experiment using a small solenoid as a test sample. Measurements are reported using both monochromatic and polychromatic neutron sources. The results show that the device is capable of extracting sample information and distinguishing small angular variations of the sample magnetic field. As a more realistic test, we present results on the characterization of a 10 μm thick Permalloy film in zero magnetic field, as well as its response to an external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low field SQUID MRI devices, components and methods

Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.

Penanen, Konstantin I.↗

Low field SQUID MRI devices, components and methods

Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.

Penanen, Konstantin I.↗

Low Field Squid MRI Devices, Components and Methods

Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.

Penanen, Konstantin I.↗

Low Field Squid MRI Devices, Components and Methods

Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.

Penanen, Konstantin I.↗

Evaluation of alternative filter media for particulate matter emission testing of residential wood heating devices

The performance of Teflon-coated glass fiber filter media (Pallflex Emfab TX40) is evaluated for particulate matter (PM) sampling of residential wood heating devices in a dilution tunnel. Thirty samples of varying duration and PM loading and concentration were collected from an U.S. Environmental Protection Agency (EPA) Method 28 dilution tunnel using dual Method 5G sample trains with untreated glass fiber and Emfab filters. Filters were weighed soon after the end of sampling and again the next day after equilibration at 35% relative humidity (RH). PM concentrations from both types of filters agreed very well with 1-day equilibration, demonstrating that Emfab filters are appropriate for use in measuring PM from residential wood burning appliances in a dilution tunnel and have performance equal to or better than the glass fiber filter media. Agreement between filter media without equilibration was erratic, with PM from glass fiber filter samples varying from slightly less than the Emfab samples to as much as 2.8 times higher. Some of the glass fiber filters lost substantial mass with equilibration, with the highest percent loss at lower filter mass loadings. Mass loss for Emfab samples was a small percentage of the mass and very consistent across the range of mass loadings. Taken together, these results may indicate water uptake on the glass fiber media that is readily removed with 1-day equilibration at moderate RH conditions. Implications: EPA regulations now allow the use of either glass fiber or Teflon filter media for wood appliance PM emission testing. Teflon filter media minimizes the potential for acid-gas PM artifacts on glass fiber filters; this is important as EPA moves toward the use of locally sourced cordwood for testing that may have higher sulfur content. This work demonstrates that the use of Teflon-coated glass fiber filters can give similar PM measurement results to glass fiber filters after 1 day of equilibration. With no equilibration, measured PM from glass fiber filters was usually higher than from Teflon-coated glass fiber filters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multiplexed microfluidic approach for nucleic acid enrichment

A system for enhancing a nucleic acid sample may include a one pump, a denaturing chamber; a microfluidic hydroxyapatite chromatography device configured for performing hydroxyapatite chromatography on the nucleic acid sample, a sample collector, and tubing connecting the pump with the denaturing chamber, the hydroxyapatite chromatography device and the sample collector such that the pump may be used to move the nucleic acid sample from the denaturing chamber to the hydroxyapatite chromatography device and then to the sample collector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial load monitor

Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.

Caplin, R. S.↗

Temporal Sampling of Enzymes from Live Cells by Localized Electroporation and Quantification of Activity by SAMDI Mass Spectrometry

Abstract Measuring changes in enzymatic activity over time from small numbers of cells remains a significant technical challenge. In this work, a method for sampling the cytoplasm of cells is introduced to extract enzymes and measure their activity at multiple time points. A microfluidic device, termed the live cell analysis device (LCAD), is designed, where cells are cultured in microwell arrays fabricated on polymer membranes containing nanochannels. Localized electroporation of the cells opens transient pores in the cell membrane at the interface with the nanochannels, enabling extraction of enzymes into nanoliter‐volume chambers. In the extraction chambers, the enzymes modify immobilized substrates, and their activity is quantified by self‐assembled monolayers for matrix‐assisted laser desorption/ionization (SAMDI) mass spectrometry. By employing the LCAD‐SAMDI platform, protein delivery into cells is demonstrated. Next, it is shown that enzymes can be extracted, and their activity measured without a loss in viability. Lastly, cells are sampled at multiple time points to study changes in phosphatase activity in response to oxidation by hydrogen peroxide. With this unique sampling device and label‐free assay format, the LCAD with SAMDI enables a powerful new method for monitoring the dynamics of cellular activity from small populations of cells.

Mukherjee, Prithvijit↗

Humidity-controlled preparation of frozen-hydrated biological samples for cryogenic coherent x-ray diffraction microscopy

Coherent x-ray diffraction microscopy (CXDM) has the potential to visualize the structures of micro- to sub-micrometer-sized biological particles, such as cells and organelles, at high resolution. Toward advancing structural studies on the functional states of such particles, here, we developed a system for the preparation of frozen-hydrated biological samples for cryogenic CXDM experiments. The system, which comprised a moist air generator, microscope, micro-injector mounted on a micromanipulator, custom-made sample preparation chamber, and flash-cooling device, allowed for the manipulation of sample particles in the relative humidity range of 20%-94%rh at 293 K to maintain their hydrated and functional states. Here, we report the details of the system and the operation procedure, including its application to the preparation of a frozen-hydrated chloroplast sample. Sample quality was evaluated through a cryogenic CXDM experiment conducted at BL29XUL of SPring-8. Taking the performance of the system and the quality of the sample, the system was suitable to prepare frozen-hydrated biological samples for cryogenic CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗