Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A versatile ultra high vacuum sample stage with six degrees of freedom

We describe the design and practical realization of a versatile sample stage with six degrees of freedom. The stage was designed for use in a Low Energy Electron Microscope, but its basic design features will be useful for numerous other applications. The degrees of freedom are X, Y, and Z, two tilts, and azimuth. All motions are actuated in an ultrahigh vacuum base pressure environment by piezoelectric transducers with integrated position sensors. The sample can be load-locked. During observation, the sample is held at a potential of −15 kV, at temperatures between room temperature and 1500 °C, and in background gas pressures up to 1 × 10{sup −4} Torr.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Significant enhancement of compositional and superconducting homogeneity in Ti rather than Ta-doped Nb 3 Sn

Nb 3 Sn wires are now very close to their final optimization but despite its classical nature, detailed understanding of the role of Ta and Ti doping in the A15 is not fully understood. Long thought to be essentially equivalent in their influence on H c2 , they were interchangeably applied. Here we show that Ti produces significantly more homogeneous chemical and superconducting properties. Despite Ta-doped samples having a slightly higher T c onset in zero-field, they always have a wider Tc-distribution. In particular, whereas the Ta-doped A15 has a T c -distribution extending from 18 down to 5-6 K (the lowest expected Tc for the binary A15 phase), the Ti-doped samples have no A15 phase with T c below ~12 K. The much narrower T c distribution in the Ti-doped samples has a positive effect on their in-field T c -distribution too, leading to an extrapolated μ0 H c2 (0) 2 Tesla larger than the Ta-doped one. Ti-doping also appears to be very homogeneous even when the Sn content is reduced in order to inhibit breakdown of the diffusion barriers in very high J c conductors. As a result, the enhanced homogeneity of the Ti-doped samples appears to result from its assistance of rapid diffusion of Sn into the filaments and by its incorporation into the A15 phase interchangeably with Sn on the Sn sites of the A15 phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evidence of feasible hardness test on Mars using ratio of ionic/neutral emission intensities measured with laser-induced breakdown spectroscopy in low pressure CO{sub 2} ambient gas

An experimental study is conducted on the possibility and viability of performing hardness measurement of the various stone and chert samples in low pressure (600 Pa) CO{sub 2} ambient gas, a condition that is encountered in the Mars atmosphere. For this study, a nanosecond Nd-YAG laser is employed to generate plasma emission from the samples with different degrees of hardness. This technique is developed in light of the role of the shock wave in the generation of a laser-induced plasma. It was previously shown that the speed of the shock front depends on the hardness of the sample, and a positive relationship was found between the speed of the shock front and the ionization rate of the ablated atoms. Hence, the ratio of the intensity between the Mg II 279.5 nm and Mg I 285.2 nm emission lines detected from the laser-induced plasma can be used to estimate the hardness of a material. In fact, it is shown that the ratio changes linearly with respect to changes of sample hardness. The result has thus demonstrated the feasibility and viability of using LIBS for non contact hardness measurement on Mars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

Discrimination between individual dust and bioparticles using aerosol time-of-flight mass spectrometry

Ice nucleating particles (INPs) impact cloud properties and precipitation processes through their ability to trigger cloud glaciation. Dust and bioparticles are two important sources of INPs that have markedly different atmospheric loadings and ice nucleating efficiencies. In situ identification of the sources of INPs in clouds has been accomplished using single particle mass spectrometry (SPMS). However, external mixtures of dust and bioparticles present a unique challenge as they have overlapping mass spectral ion signatures, complicating their unambiguous identification. This study presents a detailed discussion of dust and bioparticle SPMS signatures, uniting data from a broad array of studies. As emphasized, the ion signals from both dust and bioparticles are highly sensitive to ionization conditions. To understand the observed variations, we characterize the mass spectral dependence of distinct dust and bioparticle samples using total positive ion intensity (TPII) as an indicator of the laser pulse energy each particle encountered. Through this analysis, a broad range of characteristic biogenic low intensity ion peaks that may be useful to distinguish bioparticles from dust became apparent and are highlighted. Insights informed by this analysis were utilized to identify bioparticles in ambient SPMS data. Ambient particles exhibiting both dust and characteristic biogenic spectral fingerprints were excluded from the bioparticle classification. Although bioparticles only made up 0.2% of all sampled particles, their abundance was moderately correlated with INP concentrations measured at 15 °C.

54 ENVIRONMENTAL SCIENCES↗

Visible and infrared polarization ratio spectroreflectometer

The instrument assists in determining the refractive index and absorption index, at different spectral frequencies, of a solid sample by illuminating the sample at various angles in incidence and measuring the corresponding reflected intensities at various spectral frequencies and polarization angles. The ratio of the intensity of the reflected light for parallel polarized light to that for perpendicular polarized light at two different angles of incidence can be used to determine the optical constants of the sample. The invention involves an apparatus for facilitating the utilization of a wide variety of angles of incidence. The light source and polarizing element are positioned on an outer platform; the sample is positioned on an inner platform. The two platforms rotate about a common axis and cooperate in their rotation such that the sample is rotated one degree for every two degrees of rotation of the light source. This maintains the impingement of the reflected light upon the detector for any angle of incidence without moving or adjusting the detector which allows a continuous change in the angle of incidence.

Batten, C. E.↗

Adaptive reference voltage generator for firing angle control of line-commutated inverters

A control system for a permanent-magnet motor driven by a multiphase line-commulated inverter is described. It is provided with integrators for integrating the back EMF of each phase of the motor for use in generating system control signals for an inverter gate logic using a sync and firing angle control generator connected to the outputs of the integrators. The firing angle control signals are produced by the control generator by means for combining 120 deg segments of the integrated back EMF signals symmetrical about their maxima into composite positive and negative waveforms, and means for sampling the maxima of each waveform every 120 deg. These samples are then used as positive and negative firing angle control signals. Whereby any change in amplitude of the integrated back EMF signals will not affect a change in the operating power factor of the motor and inverter.

Dolland, C. R.↗

Spitzer Photometry of WISE-Selected Brown Dwarf and Hyper-Lumninous Infrared Galaxy Candidates

We present Spitzer 3.6 and 4.5 micrometer photometry and positions for a sample of 1510 brown dwarf candidates identified by the Wide-field Infrared Survey Explorer (WISE) all-sky survey. Of these, 166 have been spectroscopically classified as objects with spectral types M(1), L(7), T(146), and Y(12). Sixteen other objects are non-(sub)stellar in nature. The remainder are most likely distant L and T dwarfs lacking spectroscopic verification, other Y dwarf candidates still awaiting follow-up, and assorted other objects whose Spitzer photometry reveals them to be background sources. We present a catalog of Spitzer photometry for all astrophysical sources identified in these fields and use this catalog to identify seven fainter (4.5 m to approximately 17.0 mag) brown dwarf candidates, which are possibly wide-field companions to the original WISE sources. To test this hypothesis, we use a sample of 919 Spitzer observations around WISE-selected high-redshift hyper-luminous infrared galaxy candidates. For this control sample, we find another six brown dwarf candidates, suggesting that the seven companion candidates are not physically associated. In fact, only one of these seven Spitzer brown dwarf candidates has a photometric distance estimate consistent with being a companion to the WISE brown dwarf candidate. Other than this, there is no evidence for any widely separated (greater than 20 AU) ultra-cool binaries. As an adjunct to this paper, we make available a source catalog of 7.33 x 10(exp 5) objects detected in all of these Spitzer follow-up fields for use by the astronomical community. The complete catalog includes the Spitzer 3.6 and 4.5 m photometry, along with positionally matched B and R photometry from USNO-B; J, H, and Ks photometry from Two Micron All-Sky Survey; and W1, W2, W3, and W4 photometry from the WISE all-sky catalog.

Griffith, Roger L.↗

Chemistry of Apollo 12 mare basalts - Magma types and fractionation processes

Major and trace element data for a large suite of petrographically diverse Apollo 12 mare basalts are presented, and magma types sampled at the Apollo 12 site are characterized. The data confirm earlier classifications of the basalts into olivine, pigeonite, ilmenite, and feldspathic basalts. The olivine and pigeonite basalts are shown to be comagnetic and related by olivine fractionation. The other types, which differ in trace element and isotopic characteristics, are derived from different sources within the lunar interior. The spatial relations between the main basalt types are discussed in terms of local cratering events, and it is suggested that the younger ilmenite basalts overlie the olivine-pigeonite basalts. The role of olivine-dominated near-surface crystal fractionation in causing chemical variation is examined, and a relation between inferred cooling rate and the position of a sample in the fractionation sequence is determined.

Rhodes, J. M.↗

Is Tridymite at Gale Crater Evidence for Silicic Volcanism on Mars?

The X-ray diffraction (XRD) instrument (CheMin) onboard the MSL rover Curiosity detected 17 wt% of the SiO2 polymorph tridymite (relative to bulk sample) for the Buckskin drill sample (73 wt% SiO2) obtained from sedimentary rock in the Murray formation at Gale Crater, Mars. Other detected crystalline materials are plagioclase, sanidine, cristobalite, cation-deficient magnetite, and anhydrite. XRD amorphous material constitutes approx. 60 wt% of bulk sample, and the position of its broad diffraction peak near approx. 26 deg. 2-theta is consistent with opal-A. Tridymite is a lowpressure, high-temperature mineral (approx. 870 to 1670 deg. C) whose XRD-identified occurrence on the Earth is usually associated with silicic (e.g., rhyolitic) volcanism. High SiO2 deposits have been detected at Gale crater by remote sensing from martian orbit and interpreted as opal-A on the basis H2O and Si-OH spectral features. Proposed opal-A formation pathways include precipitation of silica from lake waters and high-SiO2 residues of acid-sulfate leaching. Tridymite is nominally anhydrous and would not exhibit these spectral features. We have chemically and spectrally analyzed rhyolitic samples from New Mexico and Iwodake volcano (Japan). The glassy (by XRD) NM samples have H2O spectral features similar to opal-A. The Iwodake sample, which has been subjected to high-temperature acid sulfate leaching, also has H2O spectral features similar to opal-A. The Iwodake sample has approx. 98 wt% SiO2 and 1% wt% TiO2 (by XRF), tridymite (>80 wt.% of crystalline material without detectable quartz by XRD), and H2O and Si-OH spectral features. These results open the working hypothesis that the opal-A-like high-SiO2 deposits at Gale crater detected from martian orbit are products of alteration associated with silicic volcanism. The presence or absence of tridymite will depend on lava crystallization temperatures (NM) and post crystallization alteration temperatures (Iwodake).

Morris, Richard V.↗

Microbial source tracking markers associated with domestic rainwater harvesting systems: Correlation to indicator organisms

Highlights: • Microbial source tracking markers are present in harvested rainwater. • HF183, Lachnospiraceae, B. adolescentis and adenovirus correlate with indicators. • HF183, adenovirus and Lachnospiraceae co-occurred with indicator organisms. • These MST markers may be incorporated in a toolbox to supplement indicator analysis. Domestic rainwater harvesting (tank water) systems were screened for the presence of a panel of microbial source tracking (MST) markers and traditional indicator organisms. The indicator organisms were enumerated utilizing traditional culture-based methods, while the MST markers were quantified by quantitative PCR (qPCR). The indicators Escherichia coli (E. coli) and enterococci were also quantified using qPCR. Correlations and concurrence between these parameters were then investigated to determine which markers could be utilized to supplement traditional indicator analysis. Quantitative PCR analysis indicated that Bacteroides HF183, adenovirus, Lachnospiraceae and E. coli were detected and quantifiable in 100% of the tank water samples collected throughout the sampling period, while human mitochondrial DNA (mtDNA) was quantifiable in 90% of the tank water samples and Bifidobacterium adolescentis (B. adolescentis) and enterococci were quantifiable in 67% of the tank water samples, respectively. Significant positive correlations were recorded for Lachnospiraceae versus heterotrophic bacteria (p = 0.000), adenovirus versus E. coli (culturing) (p = 0.000) and heterotrophic bacteria (p = 0.024), the HF183 marker versus E. coli (qPCR) (p = 0.024) and B. adolescentis versus fecal coliforms (p = 0.037). In addition, 100% concurrence was observed for the HF183 marker, adenovirus and Lachnospiraceae versus E. coli (qPCR), enterococci (qPCR) and heterotrophic bacteria, amongst others. Based on the correlations and the concurrence analysis, the HF183 marker, Lachnospiraceae and adenovirus may be utilized to supplement indicator organism analysis for the monitoring of harvested rainwater quality.

54 ENVIRONMENTAL SCIENCES↗

TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks

Purpose: Radiotherapy treatment is specified by radiation dose prescriptions, but biological DNA damage actually controls treatment effectiveness. It is impractical to directly measure dose in the clinic, so we measure quantities, such as collected charge, and calculate the relationship to dose. At small fields, such as those in stereotactic radiosurgery (SRS), charged-particle equilibrium (CPE) breaks down and the accuracy of the measurement for delivered dose decreases. By measuring DNA double-strand breaks (DSB) directly, we believe treatment accuracy could improve by providing a more meaningful measurement. Methods: A DNA dosimeter, consisting of magnetic streptavidin beads attached to 4 kilobase pair DNA strands labeled with biotin and fluorescein amidite (FAM) on opposing ends, was suspended in phosphate-buffered saline (PBS). Twenty µL samples were placed in plastic micro-capillary tubes inside a water tank setup and irradiated with 10 cm, 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm radiation field sizes, where the three smallest sizes were cones. After irradiation, the dosimeters were mechanically separated into beads (intact DNA) and supernatant (broken DNA/FAM) using a magnet. The fluorescence was read and the probability of DSB was calculated. This was used to calculate the output factor for an SRS beam and compared to that measured using a diode detector. Results: The output factors relative to a 10 cm field were 0.89±0.07, 0.76±0.08, 0.59±0.04, and 0.78±0.12 for the field sizes of 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm, respectively. Some of the diode measurements do not fall within these uncertainties. Conclusion: This was the first attempt to measure output factors in a water tank with the DNA dosimeter. Although differences compared to the diode were observed, the uncertainty analysis ignored systematic errors. For future work, we will repeat this experiment to quantify and correct systematic errors, such as those caused by positional alignment and sample contamination. This work was funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Kinetics of Cd Release from Some Contaminated Calcareous Soils

Contamination of soils with heavy metals may pose long-term risk to groundwater quality leading to health implications. Bioavailability of heavy metals, like cadmium (Cd) is strongly affected by sorption and desorption processes. The release of heavy metals from contaminated soils is a major contamination risks to natural waters. The release of Cd from contaminated soils is strongly influenced by its mobility and bioavailability. In this study, the kinetics of Cd desorption from ten samples of contaminated calcareous soils, with widely varying physicochemical properties, were studied using 0.01 M EDTA extraction. The median percentage of Cd released was about 27.7% of the total extractable Cd in the soils. The release of Cd was characterized by an initial fast release rate (of labile fractions) followed by a slower release rate (of less labile fractions) and a model of two first-order reactions adequately describes the observed release of Cd from the studied soil samples. There was positive correlation between the amount of Cd released at first phase of release and Cd in exchangeable fraction, indicating that this fraction of Cd is the main fraction controlling the Cd in the kinetic experiments. There was strongly negative correlation between the amount of Cd released at first and second phases of release and residual fraction, suggesting that this fraction did not contribute in Cd release in the kinetic experiments. The results can be used to provide information for evaluation of Cd potential toxicity and ecological risk from contaminated calcareous soils.

54 ENVIRONMENTAL SCIENCES↗

Effect of Exchanging Advancing and Retreating Side Materials on Mechanical Properties and Electrochemical Corrosion Resistance of Dissimilar 6013-T4 and 7003 Aluminum Alloys FSW Joints

Friction stir welding (FSW) was used to weld dissimilar joints between Al 6013-T4 and Al7003 alloys in this work. The effect of exchanging advancing (AS) and retreating (RS) side material on microstructure, mechanical behaviors and electrochemical corrosion resistance was discussed. Results showed that different joint cross sections were obtained when exchanging AS and RS materials. The material on the AS would be more deformed during the welding process. When the Al6013 placed on the AS, the plastic flow of weld is more sufficient. Whether on the AS or RS, the Al6013-T4 side is the weak region for both tensile specimens and hardness samples. The fracture position corresponds to the minimum hardness position. Also, more strengthening phase can be retained in the joint, and the joint of A6R7 has better corrosion resistance.

36 MATERIALS SCIENCE↗

A semi-empirical model for the formation and depletion of the high burnup structure in UO 2

In the rim zone of UO 2 nuclear fuel pellets, the combination of high burnup and low temperature drives a microstructural change, leading to the formation of the high burnup structure (HBS). In this work, we propose a semi-empirical model to describe the formation of the HBS, which embraces the polygonisation/recrystallization process and the depletion of intra-granular fission gas, describing them as inherently related. To this end, we per-formed grain-size measurements on samples at radial positions in which the restructuring was incomplete. Moreover, based on these new experimental data, we assume an exponential reduction of the average grain size with local effective burnup, paired with a simultaneous depletion of intra-granular fission gas driven by diffusion. The comparison with currently used models indicates the applicability of the herein developed model within integral fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of heat treatment on the microstructure of medium burn-up U-Mo monolithic fuel foils

Using scanning electron microscopy (SEM), this study evaluates the microstructure evolution of U-Mo fuel foils made with and without heat treatment at medium burn-up (of approximately 5 x 10 21 f/cm 3 ). The impact of annealing treatments on critical microstructural properties of the U-Mo fuel foils, including porosity, grain structure, Mo homogeneity, and fuel interaction with the Zr interlayer, was examined using large area lift outs (LALOs). The heat-treated specimens presented less grain refining at these burnups when compared to the un-heated specimens. Grain refinement was associated with porosities and fission products precipitation. Heat treatment can reduce fuel swelling during irradiation. Chemical inhomogeneity (Mo banding) was found to persist in the un-heated samples but was not present in the heat-treated samples. Thus, heat-treated U-Mo foils allows for more predictable fuel behavior under irradiation with respect to un-heated foils. The U-Mo and Zr interaction layer appears to be thicker and more continuous in the heat-treated sample which has been associated with stronger interface integrity during irradiation, as also observed in previous studies. These observations may indicate an overall improved performance of heat-treated fuel foil in a reactor. Further, the effect of local burn-up on grain size/refinement and porosities in each LALO specimen, sampled from different positions in the fuel foil, was difficult to analyze due to the large standard deviation of these parameters. Finally, evidence of grain refinement by polygonization may be present in these specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro- and macro-structural heterogeneities in 316L stainless steel prepared by electron-beam melting

Highlights: • Electron beam melting manufactured parts has a complicated thermal history. • The microstructure varies with the position in the sample. • Pronounced molybdenum segregation at the top disappears at the bottom. • Fast molybdenum diffusion in cell boundaries as well as grain boundaries. - Abstract: This is a study of the micro- and macrostructural variations in samples of stainless steel with the overall composition of the grade 316L, produced using electron beam melting. Electron beam melting is one of the processing methods under consideration for manufacturing some of the International Thermo- Nuclear Experimental Reactor In-Vessel components. Therefore further studies of the homogeneity of the material were conducted. Electron beam melting results in a complicated thermal history of the manufactured part giving a significant impact on the microstructure. A cellular structure that is often observed in samples prepared by selective laser melting was found in the top layers of the specimens. Further down, the structure changed until the cellular structure was almost non-existing, and the grain boundaries had become more pronounced. This revelation of a heterogeneous structure throughout the entire part is crucial for large-scale industrial applications like the Thermo- Nuclear Experimental Reactor to make sure that it is understood that the properties of the material might not be the same at every point, as well as to assure that the correct post-treatment is done. It is also exposed that a significant part of this change is due to molybdenum redistribution inside the sample when it diffuses from the cell boundaries into the cells, and into bigger agglomerates in the grain boundaries. This diffusion seems not to affect the microhardness of the samples.

36 MATERIALS SCIENCE↗