SYS645 Design for Reliability Maintainability and Supportability: H12 Universal Cartridge Carrier (circa 1952)

The initial product specification' for the H12 Universal Cartridge Carrier (UUC) was released in October 1952 and is the twelfth piece of H-Gear (sequentially numbered) ever developed. It is the oldest piece of H-Gear currently in use. To gain perspective on the number of H-Gear since designed, the most currently developed and deployed H-Gear is the H1768, Inspection Stand. The UUC, (commonly referred to as just the "H12") has since been renamed to the H12 Adjustable Hand Truck. It was developed to support various maintenance operations for ordnance assembly and disassembly. This paper will provide evidence (where available) for the H12s current state of reliability, maintainability, and sustainability (RMA). Where documented evidence is not available, conclusions will be drawn based on its continued effective use over the past 67-years of service.

42 ENGINEERING↗

Performance of Photovoltaic Systems Recorded by Open Solar Performance and Reliability Clearinghouse (oSPARC)

This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.

14 SOLAR ENERGY↗

Development of a Safe, Reliable, and Versatile Explosive Demolition Initiation System

Demolition contractors have a need to simultaneously detonate many demolition charges safely, cheaply, and reliably. An explosive distribution company has contracted the Initiation Systems Group at Lawrence Livermore Laboratory as consultants. The task is to develop a new, safer initiation system to detonate anywhere from 1 to 2000 demolition charges. The primary user of the system will be the explosive demolition contractors.

42 ENGINEERING↗

Solar-to-Grid: Trends in System Impacts, Reliability, and Market Value in the United States with Data Through 2019

With continued deployment of solar across the United States, assessing the interactions of solar with the power system is an increasingly important complement to studies tracking the cost and performance of solar plants. This project focuses on the historical contribution to reliability, trends in market value, and impacts on the bulk power system of solar deployed in the U.S. through the end of 2019.

14 SOLAR ENERGY↗

Reliability and Power Degradation Rates of PERC Modules Using Differentiated Packaging Strategies and Characterization Tools

The reliability, durability and lifetime performance of passivated emitter, rear cell (PERC) modules used in real-world PV power plants is a critical challenge underlying the rapid adoption and bankability of these PERC cells, whose high efficiency help reduce the levelized cost of electricity (LCOE). We propose a degradation-science study of PERC module degradation pathways, benchmarking them relative to known degradation mechanisms and pathways of the incumbent aluminum back surface field (Al-BSF) modules exposed to real-world and accelerated exposure conditions.

14 SOLAR ENERGY↗

Drivetrain Reliability Collaborative 1.5 (DRC1.5) Project: Joint Industry Megawatt Scale Gearbox Field Tests: Cooperative Research and Development (Final Report) CRADA Number CRD-17-00702

A new Department of Energy (DOE)/NREL industry collaboration called the Drivetrain Reliability Collaborative 1.5 (DRC1.5) will undertake field testing on a commercial multi-megawatt wind turbine drivetrain to collect loading data as installed in the turbine to thoroughly characterize drivetrain loads and responses during actual in-field conditions. A chief outcome is to provide publicly available operational loading data to the industry. This will provide a greater understanding of steady-state, transient, and fault response for both the input and output of the drivetrain; thus, facilitating improvements in the drivetrain components, lubrication system, power converter or turbine controller.

17 WIND ENERGY↗

Solar-to-Grid: Trends in System Impacts, Reliability, and Market Value in the United States with Data Through 2020

With continued deployment of solar across the United States, assessing the interactions of solar with the power system is an increasingly important complement to studies tracking the cost and performance of solar plants. This project focuses on the historical contribution to reliability, trends in market value, and impacts on the bulk power system of solar deployed in the U.S. through the end of 2020. The scope of this analysis includes the seven organized U.S. wholesale power markets and is based on historical hourly solar generation profiles for each individual plant larger than 1 MW or county-level aggregate profiles for smaller solar. In addition, we present a limited set of results for ten utilities that are outside of the independent system operator (ISO)/regional transmission organization (RTO) markets.

14 SOLAR ENERGY↗

Cost-effective, Thin-film SOFCs for Reliable Power Generation (Final Report)

The project was aimed at developing and demonstrating an advanced solid-oxide fuel cell (SOFC) technology to cost-effectively and reliably generate electricity directly from hydrocarbon fuels (e.g., natural gas and coal-derived syngas) for distributed and central generation applications. The studied technology was built on a planar, porous metal-supported SOFC (MS-SOFC) with a unique thin-film structure having its anode intimately supported on a metal substrate. The porous metal support with graded porosity was fabricated from a low-cost scalable phase-inversion tape casting method. Anode, thin-film electrolyte, and cathode were sequentially deposited on the porous metal substrate using atmospheric plasma spray (APS). In this study, it was shown that the composition of the casting slurry could significantly influence the morphology of the metal support fabricated using the phase-inversion tape-casting method. Increasing the solid loading in the slurry favored the formation and growth of finger-like pores to a point, but the presence of excessive solid loading increased the viscosity of the casting slurry, restraining the growth of finger-like pores. With the increase in the amount of the binder polyethersulfone (PESf) in the slurry, well grown finger-like pores and a thin sponge-like layer were formed. Since the parameters of the APS process have a significant effect on the microstructure of coatings, which in turn affects or determines the SOFC cell performance, a series of metal-supported solid oxide fuel cells with a four-layer cell configuration of 430L/Ni-ScSZ/ScSZ/LSCF have been fabricated by a combination of phase inversion tape casting and APS techniques. Electrochemical testing of the cells fabricated from different deposition APS conditions revealed significant differences in cell performance.

30 DIRECT ENERGY CONVERSION↗

The Optics of Deterrence: How Science Assures the Nuclear Stockpile's Reliability In Lieu of Testing

When designing a product intended to perform a certain function and satisfy some set of criteria, the standard engineering method to assess its ability to perform is to test it. This nearly universal concept works consistently, assuring proper function and generally avoiding or mitigating the consequence of failure to within acceptable limits. What would happen if the product developers were told that they must continue to certify and validate the performance without testing it, that the landscape in which the product must serve its purpose is constantly evolving, and that the product in question is the United States’ nuclear weapons stockpile? This is the position the National Nuclear Security Administration (NNSA) finds itself in; the reliability of the stockpile must be verified without actually testing it to see if it works as intended.

43 PARTICLE ACCELERATORS↗

Predictive Models and Novel Accelerated Tests for the Reliability of Cell Metallization and Solder Joints in Photovoltaic Modules

Interconnect, solder, and metallization-related failures are the primary reason for premature Si-based photovoltaic panel failure [1, 2] and can lead to a cascade of other failures, including thermal events. This combination of high severity and high occurrence means that understanding interconnect-related failures is key to the long-term health of the photovoltaic industry, and it is crucial that the industry adopt efficient and effective tests that aid in design-for-reliability and manufacturing quality control.

14 SOLAR ENERGY↗

Test Results for Checking Reliability of Selected ENDF/B-VIII.0 Evaluated Uncertainties

This report summarizes error messages obtained from counter-checking whether 1 H, 9 Be, 12 C, 27 Al, 235,238 U and 238–242 Pu relative uncertainties of ENDF/B-VIII.0 are realistic. Large parts of this report were generated automatically by the code CovVal. This code allows to test the reliability of relative uncertainties of any isotope. It gives generic error and warning messages if evaluated relative uncertainties of a particular reaction are likely under- or over-estimated. In addition to these error and warning messages, I added comments whether the flagged uncertainties are truly under- or overestimated. I call out these uncertainties that should be further investigated and corrected by an evaluator for an upcoming release of ENDF/B-VIII.1.

07 ISOTOPE AND RADIATION SOURCES↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Plasma Ignition and Combustion Stabilization Technology to Improve Flexible Operation, Reliability and Economics of an Existing Coal-Fired Boiler

GE Steam Power, Inc. (GE) proposed to improve reliability, flexibility, and economics of an existing coal-fired power plant by applying a new advanced technology developed by GE, a plasma-assisted pulverized fuel firing system. The objective of this program is to demonstrate the achievement of lower load by improved flame stabilization and therefore lower operating costs in a full-scale field installation at coal-fired electric utility. GE’s Plasma Ignition and Combustion Stabilization System is designed to operate continuously to support low load operation. With the plasma on, the flame will be attached and stable, removing the firing system as a limitation to low load operation. In addition, GE’s exclusively from ABENZ company licensed AC based technology has a 90+% system efficiency compared to all other systems at which are DC and operate with ~75% efficiency. Plant operating costs are lowered by eliminating use of expensive support fuel as well as the ability to operate at lower loads. The utilities’ ability to better match the demand curve will result in significant savings. Maintenance is lower for an AC system than a DC system as it operates at lower current. This eliminates the need for a demineralized cooling water system and provides longer electrode life which translates into both material and labor savings. It is the objective of GE to not only demonstrate the additional low load achievable with a plasma system after best achievable tuning, sensor and software approach has been exhausted, but also the increased stability of the flame at all loads with plasma assistance as well as cost savings at all low loads using plasma instead of oil. Upon successful completion of this project, GE will have sufficient field experience to rapidly deploy the Plasma Technology. The project objectives were achieved through the implementation of plasma ignitor technology at PacifiCorp Hunter Station Unit 3. A plasma ignitor system was retrofitted on ten wall-fired burners, Mill 3-4 combustion system. The Plasma Ignitors installed at Hunter proved that this GE technology is a direct and complete replacement for the original oil ignitors. The Hunter Unit 3 burner management system allows the plasma system to be used in all applications that originally required oil to be burned. This includes any time the Mill 3-4 is started or stopped for any reason including boiler starts, load changes, and low load support.

01 COAL, LIGNITE, AND PEAT↗

A MEMS Gyroscope for Reliable Long Duration Measurement While Drilling at 300°C

The 300°C Microelectromechanical system (MEMS) gyroscope project aims to contribute to DOE’s goal of increased geothermal drilling efficiency by 2025 through the development of a 300°C MEMS gyroscope for Measurement While Drilling (MWD). At the conclusion of the 2-year project, the team will develop a 300°C capable MEMS gyroscope containing GE’s patented Multi-Ring Gyroscope Transducer (MRGT) design, custom Silicon-On-Insulator (SOI) based frontend and feedback control electronics, and with demonstrated functionality and lifetime beyond 1000 hours. The project is divided into two budget periods with Go/No-Go decision at the end of the first budget period. The goal for the first budget period is to establish the feasibility of the MRGT and electronics design for meeting the 300°C performance requirements. The goal for the second budget period is to integrate the MRGT with the SOI-based application specific integrated circuit (ASIC) and demonstrate capability to operate at 300°C for 1000 hours. In Budget Period 1 we met the phase 1 goal. We successfully validated the combined MRG, electronics and packaging capability entitlement to achieving 0.5 degrees azimuth uncertainty while enabling operation at significantly higher temperatures than the state-of-the-art. In Budget Period 2, we successfully completed the integration of the MRGT and ASIC with associated high temperature, high reliability packaging to demonstrate the performance and functionality of the integrated gyroscope across the temperature range from room temperature to at 300°C. Furthermore, the team demonstrated operating life of >1,000 hours at 300°C, thus providing a validation of application-relevant lifetime capability.

15 GEOTHERMAL ENERGY↗

Ultra-fast and Thick Boriding of Geothermal Casing to Enhance Reliability

Harnessing the heat that is continuously generated underneath the Earth’s crust (geothermal) is a clean and renewable source of energy. Geothermal energy can be used to heat and cool buildings, including greenhouses, and to generate electrical power. Compared to other renewable energy sources such as solar and wind, geothermal energy is more reliable because it is available all the time and versatile in its many forms of application and deployment. Nonetheless, the deployment and extensive use of geothermal energy still lags behind other renewable sources due to some technical, but mainly economic challenges. Upfront costs of geothermal power well development are relatively high. Some of this high cost is attributed to the use of expensive construction materials to ensure adequate performance during operation. For example, Inconel 625, super duplex 2507, and titanium alloy materials are used in downhole casings, piping, and other components exposed to brine solution to withstand harsh operating environments (high temperature and corrosive environments). Relatively low-cost carbon steel can be used in many of these components in geothermal power plants; however, they are susceptible to excessive corrosion, thereby limiting their useful lifespan. Ultra-fast boriding (UFB) surface treatment of carbon steel may drastically increase its corrosion resistance thereby providing a cost-effective material solution in geothermal applications. Scientists at Argonne National Laboratory (ANL) recently developed a technique to accelerate the boriding process using a high-temperature electrochemical process to produce relatively thick boride layers on various metal and alloy materials in minutes rather than the several hours it takes through the typical pack boriding process; hence, the process is designated UFB. The process uses molten borax salt at 900– 1000°C in an electrochemical cell in which the material to be borided is the cathode and a graphite plate is the anode. Continuous and durable boride layers with thicknesses of 100–300 µm have been produced on a variety of metals and alloys in one hour. Such a surface layer can indeed be a cost-effective pathway to prevent corrosion of casing materials in contact with the chemically aggressive and corrosive geothermal brine fluids.