Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Strong-field nonsequential double photoionization using virtual-detector theory with path summation

We present an ab initio study of the nonsequential strong-field ionization dynamics of a model two-electron atom with helium character. Single- and double-ionization events are characterized and displayed using detector signals extracted at different points in the two-electron two-dimensional space. The double photoelectron momentum distribution is calculated via coherent path-summation over virtual-particle trajectories. A comparison is made between the momentum distributions obtained with the virtual-detector method, the Schrödinger wave function, and the time-dependent surface flux method developed by Tao and Scrinzi [New J. Phys. 14, 013021 (2012)]. Insights into different ionization and electron recollision pathways are gained from detailed virtual-particle tracking and energy-time readouts. Furthermore, this study demonstrates the extension of virtual-detector theory to strong-field multielectron quantum dynamics and highlights the importance of the evolving quantum phase in quasiclassical electron propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leveraging the Run 3 experience for the evolution of the ATLAS software-based readout towards HL-LHC

The High-Luminosity Large Hadron Collider (HL-LHC), scheduled to start operating in 2030, aims to increase the instantaneous luminosity by a factor of 10 compared to the LHC. To match this increase, the ATLAS experiment has been implementing a major upgrade program divided into two phases. The first phase (Phase-I), completed in 2022, introduced new trigger and detector systems that have been used during the Run 3 data taking period which began in July 2022. These systems have been used in conjunction with the new Data Acquisition (DAQ) Readout system, based on a software application called Software Readout Driver (SW ROD). SW ROD receives and aggregates data from the front-end electronics via the Front-End Link eXchange (FELIX) system and passes aggregated data fragments to the High-Level Trigger (HLT) system. During Run 3, SW ROD operates in parallel with the legacy Readout System (ROS) at an input rate of 100 kHz. For the Phase-II, the legacy ROS will be completely replaced with a new system based on the next generation of FELIX and an evolution of the SW ROD application called Data Handler. Data Handler has the same functional requirements as SW ROD but must be able to operate at an input rate of 1 MHz. To facilitate this evolution the SW ROD has been implemented using plugin architecture. This contribution presents the design and implementation of the SW ROD application for Run 3, along with the strategy for its evolution to the Phase-II Readout system. It discusses the lessons learned during Run 3 and describes the challenges that have been addressed to accomplish the demanding performance requirements of HL-LHC.

Kolos, Serguei [Univ. of California, Irvine, CA (U↗

Power system applications of fiber optic sensors

This document is a progress report of work done in 1985 on the Communications and Control for Electric Power Systems Project at the Jet Propulsion Laboratory. These topics are covered: Electric Field Measurement, Fiber Optic Temperature Sensing, and Optical Power transfer. Work was done on the measurement of ac and dc electric fields. A prototype sensor for measuring alternating fields was made using a very simple electroscope approach. An electronic field mill sensor for dc fields was made using a fiber optic readout, so that the entire probe could be operated isolated from ground. There are several instances in which more precise knowledge of the temperature of electrical power apparatus would be useful. This report describes a number of methods whereby the distributed temperature profile can be obtained using a fiber optic sensor. The ability to energize electronics by means of an optical fiber has the advantage that electrical isolation is maintained at low cost. In order to accomplish this, it is necessary to convert the light energy into electrical form by means of photovoltaic cells. JPL has developed an array of PV cells in gallium arsenide specifically for this purpose. This work is described.

Johnston, A. R.↗

Improved charge injection device and a focal plane interface electronics board for stellar tracking

An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered.

Michon, G. J.↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Optical readout of singlet fission biexcitons in a heteroacene with photoluminescence detected magnetic resonance

Molecular spin systems based on photoexcited triplet pairs formed via singlet fission (SF) are attractive as carriers of quantum information because of their potentially pure and controllable spin polarization, but developing systems that offer optical routes to readout as well as initialization is challenging. Herein, we characterize the electron spin magnetic resonance change in the photoluminescence intensity for a tailored organic molecular crystal while sweeping a microwave drive up to 10 GHz in a broadband loop structure. We observe resonant transitions for both triplet and quintet spin sublevel populations showing their optical sensitivity and revealing the zero-field parameters for each. We map the evolution of these spectra in both microwave frequency and magnetic field, producing a pattern of optically detected magnetic resonance (ODMR) peaks. Fits to these data using a suitable model suggest significant spin polarization in this system with orientation selectivity. Unusual excitation intensity dependence is also observed, which inverts the sign of the ODMR signal for the triplet features, but not for the quintet. These observations demonstrate optical detection of the spin sublevel population dictated by SF and intermolecular geometry, and highlight anisotropic and multi-scale dynamics of triplet pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: "megatiles" with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. Further, we found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.

47 OTHER INSTRUMENTATION↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Algorithms for High-Speed Noninvasive Eye-Tracking System

Two image-data-processing algorithms are essential to the successful operation of a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. The system was described in High-Speed Noninvasive Eye-Tracking System (NPO-30700) NASA Tech Briefs, Vol. 31, No. 8 (August 2007), page 51. To recapitulate from the cited article: Like prior commercial noninvasive eyetracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Most of the prior commercial noninvasive eyetracking systems rely on standard video cameras, which operate at frame rates of about 30 Hz. Such systems are limited to slow, full-frame operation. The video camera in the present system includes a charge-coupled-device (CCD) image detector plus electronic circuitry capable of implementing an advanced control scheme that effects readout from a small region of interest (ROI), or subwindow, of the full image. Inasmuch as the image features of interest (the cornea and pupil) typically occupy a small part of the camera frame, this ROI capability can be exploited to determine the direction of gaze at a high frame rate by reading out from the ROI that contains the cornea and pupil (but not from the rest of the image) repeatedly. One of the present algorithms exploits the ROI capability. The algorithm takes horizontal row slices and takes advantage of the symmetry of the pupil and cornea circles and of the gray-scale contrasts of the pupil and cornea with respect to other parts of the eye. The algorithm determines which horizontal image slices contain the pupil and cornea, and, on each valid slice, the end coordinates of the pupil and cornea. Information from multiple slices is then combined to robustly locate the centroids of the pupil and cornea images. The other of the two present algorithms is a modified version of an older algorithm for estimating the direction of gaze from the centroids of the pupil and cornea. The modification lies in the use of the coordinates of the centroids, rather than differences between the coordinates of the centroids, in a gaze-mapping equation. The equation locates a gaze point, defined as the intersection of the gaze axis with a surface of interest, which is typically a computer display screen (see figure). The expected advantage of the modification is to make the gaze computation less dependent on some simplifying assumptions that are sometimes not accurate

Talukder, Ashit↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

Single electrons on solid neon as a solid-state qubit platform

Progress towards the realization of quantum computers requires persistent advances in their constituent building blocks-qubits. Novel qubit platforms that simultaneously embody long coherence, fast operation and large scalability offer compelling advantages in the construction of quantum computers and many other quantum information systems 1-3 . Electrons, ubiquitous elementary particles of non-zero charge, spin and mass, have commonly been perceived as paradigmatic local quantum information carriers. Despite superior controllability and configurability, their practical performance as qubits through either motional or spin states depends critically on their material environment 3-5 . In this work, we report our experimental realization of a qubit platform based on isolated single electrons trapped on an ultraclean solid neon surface in vacuum 6-13 . By integrating an electron trap in a circuit quantum electrodynamics architecture 14-20 , we achieve strong coupling between the motional states of a single electron and a single microwave photon in an on-chip superconducting resonator. Qubit gate operations and dispersive readout are implemented to measure the energy relaxation time T 1 of 15 μs and phase coherence time T 2 over 200 ns. These results indicate that the electron-on-solid-neon qubit already performs near the state of the art for a charge qubit 21 .

36 MATERIALS SCIENCE↗