Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The ratio of animal protein intake to potassium intake is a predictor of bone resorption in space flight analogues and in ambulatory subjects

BACKGROUND: Bone loss is a critical concern for space travelers, and a dietary countermeasure would be of great benefit. Dietary protein and potassium-associated bicarbonate precursors may have opposing effects on the acid-base balance in the body and therefore on bone loss. OBJECTIVE: In 2 studies, we examined the ability of dietary protein and potassium to predict markers of bone metabolism. DESIGN: In the first study, 8 pairs of male identical twins were assigned to 1 of 2 groups: bed rest (sedentary, or SED, group) or bed rest with supine treadmill exercise in a lower-body negative pressure chamber (EX group). In a second study, groups of 4 subjects lived in a closed chamber for 60 or 91 d, and dietary data were collected for two or three 5-d sessions. Urinary calcium, N-telopeptide, and pyridinium cross-links were measured before bed rest; on bed rest days 5-6, 12-13, 19-20, and 26-27; and daily during the chamber studies. Data were analyzed by Pearson's correlation (P < 0.05). RESULTS: The ratio of animal protein intake to potassium intake was significantly correlated with N-telopeptide in the SED group during bed rest weeks 3 and 4 (r = 0.77 and 0.80) and during the 91-d chamber study (r = 0.75). The ratio of animal protein intake to potassium intake was positively correlated with pyridinium cross-links before bed rest in the EX group (r = 0.83), in the EX group during bed rest week 1 (r = 0.84), and in the SED group during bed rest week 2 (r = 0.72) but not during either chamber study. In both studies, these relations were not significant with the ratio of vegetable protein intake to potassium intake. CONCLUSIONS: The ratio of animal protein intake to potassium intake may affect bone in ambulatory and bed-rest subjects. Changing this ratio may help to prevent bone loss on Earth and during space flight.

Clinical Trial↗

Extinction-to-Backscatter Ratios of Saharan Dust Layers Derived from In-Situ Measurements and CALIPSO Overflights During NAMMA

We determine the aerosol extinction-to-backscatter (Sa) ratios of dust using airborne in-situ measurements of microphysical properties, and CALIPSO observations during the NASA African Monsoon Multidisciplinary Analyses (NAMMA). The NAMMA field experiment was conducted from Sal, Cape Verde during Aug-Sept 2006. Using CALIPSO measurements of the attenuated backscatter of lofted Saharan dust layers, we apply the transmittance technique to estimate dust Sa ratios at 532 nm and a 2-color method to determine the corresponding 1064 nm Sa. Using this method, we found dust Sa ratios of 39.8 plus or minus 1.4 sr and 51.8 plus or minus 3.6 sr at 532 nm and 1064 nm, respectively. Secondly, Sa ratios at both wavelengths is independently calculated using size distributions measured aboard the NASA DC-8 and estimates of Saharan dust complex refractive indices applied in a T-Matrix scheme. We found Sa ratios of 39.1 plus or minus 3.5 sr and 50.0 plus or minus 4 sr at 532 nm and 1064 nm, respectively, using the T-Matrix calculations applied to measured size spectra. Finally, in situ measurements of the total scattering (550 nm) and absorption coefficients (532 nm) are used to generate an extinction profile that is used to constrain the CALIPSO 532 nm extinction profile.

Omar, Ali H.↗

Drop Axis Ratio Distributions in Stratiform and Convective Rain

A fully calibrated low profile 2D video disdrometer (2DVD) has been recording many different rainfall events in Northern Alabama (USA) since June 2007. An earlier publication reported drop shapes and axis ratio distributions determined for some of the events. For one of the cases examined, a noticeable shift in the 3.5 - 3.75 mm drop axis ratio distribution was noted. In this paper, we extend the earlier work by separating the 2DVD measurements into stratiform and convective rain. The separation is made possible by using the minute-by-minute drop size distribution (DSD) measured by the 2DVD. The 1-minute DSDs are fitted to a gamma distribution, and using a simple indexing technique which involves two of the fitted parameters, periods of convective and stratiform rain are separated for a given event. The output of the DSD indexing technique is qualitatively confirmed by comparing with simultaneous time series observations from a co-located UHF profiler which continuously records height profiles of reflectivity, Doppler mean and spectral width, all of which enable the identification of bright-band periods and, furthermore, periods of moderate and deep convection. Excellent consistency is found between the output of the DSD-based separation method and the profiler observations. Next, we utilize the output of DSD index-based separation method to flag the periods of severe convection for a given event. Drop axis ratios during the flagged periods are derived and compared with those during stratiform rain periods. Five cases have been considered. Axis ratio distributions do not show appreciable differences between stratiform and convective periods for four of the cases. The fifth case (the same case as reported earlier) shows a shift in the 3.5 - 3.75 mm drop axis ratios during a prolonged period of convection. The contoured shapes for these drops determined from the 2DVD camera data indicate the possibility of non-axisymmetric oscillations, compared with the contoured images for other events which fit well to our reference drop shapes. For all of above cases, observations from a C-band polarimetric radar - situated 15 km away are examined. The variations between the co-polar radar reflectivity and the differential reflectivity as well as the specific differential phase are compared with the 2DVD data based scattering calculations for the 5 events. The implications will be discussed.

Thurai, M.↗

The C-12/C-13 Ratio as a Chemistry Indicator

Isotopic ratios of elements are considered powerful tools, e.g. in tracing the origin of solar system body materials, or the degree of nucleosynthesis processing throughout the Galaxy. In interstellar molecules, some isotopic ratios like H/D and C-12/C-13 can also be used as indicators of their chemical origin. Isotope fractionation in gas-phase chemical reactions and gas-dust interaction makes observations of the ratio between C-12 and C-13 isotopologues suitable to distinguish between different formation scenarios. We will present observations of the C-12/C-13 ratio in methanol and formaldehyde towards a sample of embedded, massive young stellar objects. In relation to this we also present results from theoretical modeling showing the usefulness of the C-12/C-13 ratio as a chemistry indicator.

Wirstroem, Eva↗

High Bypass Ratio Jet Noise Reduction and Installation Effects Including Shielding Effectiveness

An experimental investigation was performed to study the propulsion airframe aeroacoustic installation effects of a separate flow jet nozzle with a Hybrid Wing Body aircraft configuration where the engine is installed above the wing. Prior understanding of the jet noise shielding effectiveness was extended to a bypass ratio ten application as a function of nozzle configuration, chevron type, axial spacing, and installation effects from additional airframe components. Chevron types included fan chevrons that are uniform circumferentially around the fan nozzle and T-fan type chevrons that are asymmetrical circumferentially. In isolated testing without a pylon, uniform chevrons compared to T-fan chevrons showed slightly more low frequency reduction offset by more high frequency increase. Phased array localization shows that at this bypass ratio chevrons still move peak jet noise source locations upstream but not to nearly the extent, as a function of frequency, as for lower bypass ratio jets. For baseline nozzles without chevrons, the basic pylon effect has been greatly reduced compared to that seen for lower bypass ratio jets. Compared to Tfan chevrons without a pylon, the combination with a standard pylon results in more high frequency noise increase and an overall higher noise level. Shielded by an airframe surface 2.17 fan diameters from nozzle to airframe trailing edge, the T-fan chevron nozzle can produce reductions in jet noise of as much as 8 dB at high frequencies and upstream angles. Noise reduction from shielding decreases with decreasing frequency and with increasing angle from the jet inlet. Beyond an angle of 130 degrees there is almost no noise reduction from shielding. Increasing chevron immersion more than what is already an aggressive design is not advantageous for noise reduction. The addition of airframe control surfaces, including vertical stabilizers and elevon deflection, showed only a small overall impact. Based on the test results, the best overall nozzle configuration design was selected for application to the N2A Hybrid Wing Body concept that will be the subject of the NASA Langley 14 by 22 Foot Subsonic Tunnel high fidelity aeroacoustic characterization experiment. The best overall nozzle selected includes T-fan type chevrons, uniform chevrons on the core nozzle, and no additional pylon of the type that created a strong acoustic effect at lower bypass ratios. The T-fan chevrons are oriented azimuthally away from the ground observer locations. This best overall nozzle compared to the baseline nozzle was assessed, at equal thrust, to produce sufficient installed noise reduction of the jet noise component to enable the N2A HWB to meet NASA s noise goal of 42 dB cumulative below Stage 4.

Thomas, Russell H.↗

Isotopic Ratios of H, C, N, O, and S in Comets C2012 F6 (lemmon) and C2014 Q2 (lovejoy) * ** ***

The apparition of bright comets C/2012 F6 (Lemmon) and C/2014 Q2 (Lovejoy) in March-April 2013 and January 2015, combined with the improved observational capabilities of submillimeter facilities, offered an opportunity to carry out sensitive compositional and isotopic studies of the volatiles in their coma. We observed comet Lovejoy with the IRAM 30 meter telescope between 13 and 26 January 2015, and with the Odin submillimeter space observatory on 29 January - 3 February 2015. We detected 22 molecules and several isotopologues. The H2 O-16 and H2 O-18 production rates measured with Odin follow a periodic pattern with a period of 0.94 days and an amplitude of approximately 25 percent. The inferred isotope ratios in comet Lovejoy are O-16/O-18 = 499 +/- 24 and D/H equals 1.4 +/- 0.4 x 10(exp -4) in water, S-32/S-34 = equals 24.7 +/- 3.5 in CS, all compatible with terrestrial values. The ratio C-12/C-13 equals 109 +/- 14 in HCN is marginally higher than terrestrial and 14 N/ 15/N equals 145 +/- 12 in HCN is half the Earth ratio. Several upper limits for D/H or C-12/ C-13 in other molecules are reported. From our observation of HDO in comet C/2014 Q2 (Lovejoy), we report the first D/H ratio in an Oort Cloud comet that is not larger than the terrestrial value. On the other hand, the observation of the same HDO line in the other Oort-cloud comet, C/2012 F6 (Lemmon), suggests a D/H value four times higher. Given the previous measurements of D/H in cometary water, this illustrates that a diversity in the D/H ratio and in the chemical composition, is present even within the same dynamical group of comets, suggesting that current dynamical groups contain comets formed at very different places or times in the early solar system.

Biver, N.↗

Fe xvii 2p–3s Line Ratio Diagnostic of Shock Formation Radius in O Stars

The 2p–3s lines of Fe xvii in the X-ray spectrum of the O-type star ζ Puppis exhibit an anomalous (3G + M2)/(3F) line ratio of ∼1.4, in comparison with ∼2.4 for almost all other collisionally excited astrophysical spectra. Based on the work of Mauche et al., we conjectured that the strong UV field of ζ Puppis produces the observed ratio by depopulation of metastable 3s excited states, and that the ratio can potentially be used as an independent diagnostic of plasma formation radius. We used the Flexible Atomic Code collisional-radiative model to model the effect of UV photoexcitation from O stars on the Fe xvii lines. We compared our model calculations to archival spectra of coronal and hot stars from the Chandra HETGS and XMM-Newton RGS to benchmark our calculations for various electron densities and UV field intensities. Our calculations show that UV photoexcitation does not produce a sufficiently large dynamic range in the 3F / (3F + 3G + M2) fraction to explain the difference in the observed ratio between coronal stars and ζ Pup. Thus, this effect likely cannot explain the observed line ratio of ζ Pup, and its origin is still unexplained.

Gabriel J. Grell↗

Fe XVII 2p–3s Line Ratio Diagnostic of Shock Formation Radius in O Stars

The 2p–3s lines of Fe xvii in the X-ray spectrum of the O-type star ζ Puppis exhibit an anomalous (3G + M2)/(3F) line ratio of ∼1.4, in comparison with ∼2.4 for almost all other collisionally excited astrophysical spectra. Based on the work of Mauche et al., we conjectured that the strong UV field of ζ Puppis produces the observed ratio by depopulation of metastable 3s excited states, and that the ratio can potentially be used as an independent diagnostic of plasma formation radius. We used the Flexible Atomic Code collisional-radiative model to model the effect of UV photoexcitation from O stars on the Fe xvii lines. We compared our model calculations to archival spectra of coronal and hot stars from the Chandra HETGS and XMM-Newton RGS to benchmark our calculations for various electron densities and UV field intensities. Our calculations show that UV photoexcitation does not produce a sufficiently large dynamic range in the 3F / (3F + 3G + M2) fraction to explain the difference in the observed ratio between coronal stars and ζ Pup. Thus, this effect likely cannot explain the observed line ratio of ζ Pup, and its origin is still unexplained.

Gabriel Grell↗

Characterization of Errors in Satellite-Based HCHO/NO 2 Tropospheric Column Ratios With Respect to Chemistry, Column-to-PBL Translation, Spatial Representation, and Retrieval Uncertainties

The availability of formaldehyde (HCHO) (a proxy for volatile organic compound reactivity) and nitrogen dioxide (NO 2 ) (a proxy for nitrogen oxides) tropospheric columns from ultraviolet–visible (UV–Vis) satellites has motivated many to use their ratios to gain some insights into the near-surface ozone sensitivity. Strong emphasis has been placed on the challenges that come with transforming what is being observed in the tropospheric column to what is actually in the planetary boundary layer (PBL) and near the surface; however, little attention has been paid to other sources of error such as chemistry, spatial representation, and retrieval uncertainties. Here we leverage a wide spectrum of tools and data to quantify those errors carefully. Concerning the chemistry error, a well-characterized box model constrained by more than 500 h of aircraft data from NASA's air quality campaigns is used to simulate the ratio of the chemical loss of HO 2 + RO 2 (LRO x ) to the chemical loss of NO x (LNO x ). Subsequently, we challenge the predictive power of HCHO/NO 2 ratios (FNRs), which are commonly applied in current research, in detecting the underlying ozone regimes by comparing them to LRO x /LNO x . FNRs show a strongly linear (R 2 =0.94) relationship with LRO x /LNO x , but only on the logarithmic scale. Following the baseline (i.e., ln(LRO x /LNO x ) = −1.0 ± 0.2) with the model and mechanism (CB06, r2) used for segregating NO x -sensitive from VOC-sensitive regimes, we observe a broad range of FNR thresholds ranging from 1 to 4. The transitioning ratios strictly follow a Gaussian distribution with a mean and standard deviation of 1.8 and 0.4, respectively. This implies that the FNR has an inherent 20 % standard error (1σ) resulting from not accurately describing the RO x –HO x cycle. We calculate high ozone production rates (PO 3 ) dominated by large HCHO × NO 2 concentration levels, a new proxy for the abundance of ozone precursors. The relationship between PO 3 and HCHO × NO 2 becomes more pronounced when moving towards NO x -sensitive regions due to nonlinear chemistry; our results indicate that there is fruitful information in the HCHO × NO 2 metric that has not been utilized in ozone studies. The vast amount of vertical information on HCHO and NO 2 concentrations from the air quality campaigns enables us to parameterize the vertical shapes of FNRs using a second-order rational function permitting an analytical solution for an altitude adjustment factor to partition the tropospheric columns into the PBL region. We propose a mathematical solution to the spatial representation error based on modeling isotropic semivariograms. Based on summertime-averaged data, the Ozone Monitoring Instrument (OMI) loses 12 % of its spatial information at its native resolution with respect to a high-resolution sensor like the TROPOspheric Monitoring Instrument (TROPOMI) (> 5.5 × 3.5 km 2 ). A pixel with a grid size of 216 km 2 fails at capturing ∼ 65 % of the spatial information in FNRs at a 50 km length scale comparable to the size of a large urban center (e.g., Los Angeles). We ultimately leverage a large suite of in situ and ground-based remote sensing measurements to draw the error distributions of daily TROPOMI and OMI tropospheric NO 2 and HCHO columns. At a 68 % confidence interval (1σ), errors pertaining to daily TROPOMI observations, either HCHO or tropospheric NO 2 columns, should be above 1.2–1.5 × 10 16 molec. cm −2 to attain a 20 %–30 % standard error in the ratio. This level of error is almost non-achievable with the OMI given its large error in HCHO. The satellite column retrieval error is the largest contributor to the total error (40 %–90 %) in the FNRs. Due to a stronger signal in cities, the total relative error (< 50 %) tends to be mild, whereas areas with low vegetation and anthropogenic sources (e.g., the Rocky Mountains) are markedly uncertain (> 100 %). Our study suggests that continuing development in the retrieval algorithm and sensor design and calibration is essential to be able to advance the application of FNRs beyond a qualitative metric.

Amir H. Souri↗

Establishing an isoelectronic line ratio temperature diagnostic for soft X-ray absorption spectroscopy

For diagnosing temperatures of high-energy-density plasmas, relying on the ratio of a pair of isoelectronic spectral lines provides the alternative of ‘‘matched charge-state transits in different elements’’ to the more conventional, ‘‘unmatched charge-state transits in the same-element’’ spectral-line-ratio technique. In contrast to a novel previous establishment of isoelectronic emission-line ratio determination of plasma temperature, this report determines plasma temperature from the ratio of isoelectronic absorption spectral line pairs. Here, the feasibility of this technique is assessed from experimentally acquired transmission spectra, spanning the 7– 15 Å range, through a 0.4 μm MgO-NaF foil, tamped with CH, x-ray-radiation heated by a z-pinch dynamic hohlraum (ZPDH), and backlit by the brief X-ray burst upon imploding-wire stagnation on the Z pulsed-power facility at Sandia National Laboratories. As expected from the slight difference between interstage and isoelectronic absorption processes, a quantitative comparison between the value of isoelectronic-absorption-derived temperature and the value of inter-stage-absorption-derived temperature is shown to yield a well correlated, slight difference in inferred values of plasma temperature associated with local thermodynamic equilibrium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Machine learning-aided line intensity ratio technique applied to deuterium plasmas

It has been demonstrated that the electron density, n e , and temperature, T e , are successfully evaluated from He I line intensity ratios coupled with machine learning (ML). In this paper, the ML-aided line intensity ratio technique is applied to deuterium (D) plasmas with 0.031 < n e (10 18 m –3 ) < 0.67 and 2.3 < T e (eV) < 5.1 in the PISCES-A linear plasma device. Two line intensity ratios, D α /D γ and D α /D β , are used to develop a predictive model for n e and T e separately. Reasonable agreement of both ne and Te with those from single Langmuir probe measurements is obtained at n e > 0.1 × 10 18 m –3 . Addition of the D 2 /D α intensity ratio, where the D 2 band emission intensity is integrated in a wavelength range of λ ~ 557.4–643.0 nm, is found to improve the prediction of, in particular, n e , and T e . It is also confirmed that the technique works for D plasmas with 0.067 < n e (10 18 m –3 ) < 6.1 and 0.8 < T e (eV) < 15 in another linear plasma device, PISCES-RF. The two training datasets from PISCES-A and PISCES-RF are combined, and unified predictive models for n e and T e give reasonable agreement with probe measurements in both devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure–property relations of sodium iron phosphate nuclear waste glasses: Effects of iron redox ratio and glass composition

Iron phosphate glasses, known for their exceptional chemical durability and potential applicability in nuclear waste management, have gained significant attention over the years. The structures of these glasses are complicated by the coexistence of Fe 3+ and Fe 2+ , which plays a crucial role in determining their structures and properties. Here, this work uses molecular dynamics simulations to study the structural changes in Na 2 O–Fe 2 O 3 –P 2 O 5 glasses with varying glass composition and Fe 2+ /Fe 3+ redox ratio. It was found that the redox ratio and modifier contents significantly affected the short-range and medium-range orders in the glasses. Significant changes in the local environments around P 5+ and Fe 3+ were observed, as reflected by the bond distances and coordination numbers. Na + cations are found to preferentially associate with Fe 3+ (rather than Fe 2+ ), whereas Fe 2+ has stronger association with P 5+ than Na + , confirming the structural role of Fe 2+ as a glass modifier. The disruptions in P–O–P linkages upon increasing FeO suggest that FeO causes glass depolymerization. These glasses achieved higher connectivity with increasing Fe 3+ / (Fe 3+ + Fe 2+ ) ratios, conerting phosphorous Q 2 to Q 3 units and iron Q 5 units to Q 4 units. The decrease of nonbridging oxygen fractions with increasing Fe 3+ / (Fe 3+ + Fe 2+ ) ratios, through creating P–O–Fe linkages, is the main reason of enhanced network connectivity. Quantitative structure–property relationship analyses with different structural descriptors were used to correlate with measured properties. The analyses provided valuable insights into structure–property relationships, emphasizing the importance of choosing relevant energy parameters and defining glass network connectivity, particularly in F net descriptors. It was found the Fe–O–P linkage density exhibits strong correlations to measured dissolution rates, supporting the importance of these linkages in improving the chemical durability in iron phosphate glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Experimental Test of the Ratio Method

The ratio is a new reaction observable suggested to extract accurately structure information on halo nuclei. It corresponds to the ratio of differential cross sections for scattering and breakup, which is predicted to remove the uncertainty related to the reaction dynamics. We present here the first experimental test of the method for the 11 Be + 12 C collision at E Lab = 20A MeV performed at Texas A&M University. Differential cross sections for scattering and inclusive one-neutron breakup have been measured with the new detector array BlueSTEAl. The ratio of cross sections is very smooth and independent of the projectile-target interaction, which demonstrates the validity of the ratio method. We extend our analysis to existing 11 Be + 208 Pb data, confirming that the method works well on any target.

11Be↗

The Effect of Compression Ratio on Knock Limits of High-Performance Fuels in a CFR Engine II : Blends of 2,2,3-Trimethylpentane with 28-R

The knock-limited performance of blends of 0,50; and 100 percent by volume of 2,2,3-trimethylpentane in 28-R fuel determined with a modified F-4 engine at three sets of conditions varying from severe to mild at each of three compression ratios (6.0, 8.0, and 10.0). A comparison of the knock-limited performance of 2,2,3-trimethylpentane with that of triptane (2,2,3-trimethylbutane) is included. The knock-Limited performance of 2,2,3-trimethylpontane was usually more sensitive to either compression ratio or inlet-air temperature than 28-R fuel, but the ratio of the knock-limited indicated mean effective pressure of a given blend containing 2,2,3-trimethypentane and 28-R to the indicated mean effective pressure of 28-R alone was not greatly affected by compression ratio if the engine operating conditions were mild. Although 2,2,3-trimethylpentane in general had a lower knock-limited performance than triptane, the characteristics of the two fuels were somewhat similar.

FUELS, ANTIKNOCK↗

Upgrades to the Single Stage Axial Compressor and Fan Facility For Low Pressure Ratio and Boundary Layer Ingesting Fan Research

Next generation aircraft engine efficiency goals will be met through high bypass ratio engines. To achieve these goals, a combination of small core and low pressure ratio fan technologies will be necessary. Additionally, advanced propulsion air-frame integration concepts, such as boundary layer propulsion, and distributed electrically driven fans with short inlets or wing integration strategies, are beginning to be investigated for their potential fuel burn savings. In order to realize the potential fuel savings from these technologies, it is necessary to have testing capabilities for the components. The NASA Glenn Research Center (GRC) Single StageAxial Fan and Compressor Facility (also called the GRC W-8Facility) has recently undergone several significant upgrades in order to effectively test low pressure ratio fans and various inlet distortions. This paper will outline various challenges to testing low pressure ratio fans and the methods implemented to ensure that the W-8 facility is capable of performing these tests and acquiring high quality data. The upgrades include significant pip-ing upgrades to reduce pressure loss and turbulence, capability for inlet total pressure and swirl distortion, increased test section length including a longer shaft, a two component balance, an up-graded rotating data system, and a new temperature characterization to reduce uncertainties in thermocouple measurements

W-8 Facility↗

Deriving New Mixing Ratios for Venus Atmospheric Gases Using Data From the Pioneer Venus Large Probe Neutral Mass Spectrometer

We present the first published method to convert data obtained by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) into units of mixing ratio (ppm) and volume percent (v%) against CO 2 and N 2 , the dominant Venus atmospheric gases, including conversion to density (kg m −3 ). These unit conversions are key to unlocking the untapped potential of the data, which represents a significant challenge given the scant calibration data in the literature. Herein, we show that our data treatments and conversions yield mixing ratios and volume percent values for H 2 O, N 2 , and SO 2 that are within error to those reported for the gas chromatograph (LGC) on the Pioneer Venus Large Probe (PVLP). For the noble gases, we developed strategies to correct for instrument biases by treating the data as a relative scale and using PVLP and Venera-based measurements as calibration points. Together, these methods, conversions, calibrations, and comparisons afford novel unit conversions for the LNMS data and yield unified measures for Venus’ atmosphere from the LNMS and LGC on the PVLP. - Conversion into mixing ratio (ppm), volume percent (v%), and density (kg m −3 ). - Mixing ratios are expressed against CO 2 and N 2 . - LNMS and LGC measurements on the PVLP are consistent.

Venus↗

Synergistic Alignment of Low Aspect‐Ratio π‐Conjugated Molecules Enables Exceptional UV–vis–NIR Polarization Detection

Abstract Polarization detection enhances signal contrast and is widely utilized in diverse advanced applications. An ongoing challenge is the development of high‐performance polarization‐sensitive photodetectors based on optically anisotropic organic semiconductors, particularly in the near‐infrared (NIR) region. While uniaxially aligned π‐conjugated polymers with high aspect ratios exhibit strong linear dichroism and have shown promise, their limited NIR performance and heavy reliance on polymer material now represent critical limitations. Here, a breakthrough is reported in achieving giant linear dichroism and exceptional polarization detection with low aspect‐ratios (AR) non‐fullerene small‐molecule (NFSM) acceptors, extending polarization sensitivity from the UV–vis to the NIR range. An impressive dichroic ratio of 27.1 at 605 nm and 12.0 at 780 nm is demonstrated. The maximum polarization photocurrent ratio is 11.2 at 780 nm under parallel versus perpendicular polarized light. This unprecedented performance originates from synergistic molecular alignment, wherein NFSMs significantly enhance the uniaxial orientation of both the polymer matrix and the NFSMs themselves during self‐assembly and thermal annealing. Besides, such a linear‐polarization‐sensitive photodetectors (LPS‐PDs) are showcased in generating degree‐of‐linear‐polarization imaging. The work establishes NFSMs as a viable material system for next‐generation of organic LPS‐PDs and provides fundamental insights into structural origins of polarization sensitivity in low AR organic semiconductors.

Xue, Yingying↗