Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Probing Electrode-Electrolyte Interfaces Using Nano-Gap Surface-Enhanced Raman Spectroscopy and Imaging

Performance of portable electronic devices and electric vehicles is currently limited by the energy density, lifetime and safety of lithium rechargeable batteries. Overcoming those limitations requires in-depth understanding of the electrode-electrolyte interfaces. Surface-enhanced Raman spectroscopy (SERS) can provide a critical component to this effort as an in situ technique with ultrahigh surface sensitivity that provides quantitative molecular specificity. SERS relies on local electromagnetic field amplification generated by surface plasmon resonance (SPR) at the surface of metal nanoparticles (NPs) with sub-wavelength dimensions. The most significant Raman enhancements have been observed when the local SPRs of multiple NPs interact. This occurs when the NPs are in close proximity (less than 10 nm), which could be achieved in ordered NP monolayers if they could be assembled reproducibly. Methods to assemble gold NPs into large area (cm2) monolayers will be presented. The interparticle gap can be tuned between 1 and 4 nm by using surface ligands of different sizes. The Au NP monolayers exhibit high SERS sensitivity (enhancement factor greater than 107). This allows for the measurement of electrolyte components across a broad range of concentrations. Components include lithium hexafluorophosphate (LiPF6), fluoroethylene carbonate (FEC), ethylene carbonate (EC) and diethyl carbonate (DEC). The investigation of solutions of LiPF6 in EC + DEC binary solvents using SERS allows for the determination of the solvent coordination numbers, which range from 2 to 5. This result is in sharp contrast to the bulk values calculated from infrared spectroscopy, which range from 3 to 7. Numerical simulations show that the electromagnetic field is concentrated in the nanogap, indicating the information of the aprotic electrolyte solution structures is obtained from the immediately adjacent area of the solid substrate. Our findings facilitate a better understanding of the structure of solvated ions in close proximity to the electrode surface.

Yang, Guang↗

A Survey of Olivine Alteration Products Using Raman Spectroscopy

Identification of mineral alteration products will aid in the crucial task of interpreting past Martian environmental conditions, especially aqueous environments. Olivine has been identified at the surface of Mars and is readily altered in aqueous environments. Using Raman spectroscopy, we studied three rocks with altered olivine and compared the data with mineral chemistry from electron microprobe analysis. Although the alteration in all three samples has loosely been called iddingsite their appearances and modes of occurrences differ as described. Alteration products in all three samples are likely fine-grained mixtures.

Kuebler, K.↗

Monitoring Sulfuric Acid and Temperature Using Raman Spectroscopy and Multivariate Chemometrics

Multivariate regression models were optimized for the quantification of sulfuric acid (H 2 SO 4 ) [0–8 M] and temperature (20 °C–80 °C) in the presence of ammonium sulfate ((NH 4 ) 2 SO 4 [0–0.6 M]) using Raman spectroscopy. Optical vibrational spectroscopy is a useful nondestructive technique for the in situ analysis of complex chemical systems notoriously difficult to monitor in situ and in real-time. Multivariate analysis, a chemometrics method, can be paired with these nondestructive optical methods for determining analyte concentration and speciation in complex solutions, such as dissociated species in polyprotic acids, e.g., H 2 SO 4 . The effect of temperature is often overlooked although it can have a major influence on speciation and the corresponding Raman spectra. Here, in this study, partial least squares regression models were optimized for the quantification of H 2 SO 4 and its two deprotonated forms as a function of temperature. Measuring bisulfate as a function of temperature is particularly challenging owing to changes in the second dissociation constant. A designed training set effectively minimized the sample set size and trained a robust predictive model with percent root mean square error of <3% for H 2 SO 4 . The practical strategy employed here was demonstrated to be effective for building chemometric models that directly account for dynamic temperatures with static samples and is shown to be amenable to flow cell analysis applications with a simple calibration transfer for process monitoring applications.

D-optimal design↗

Residual stress analysis of aluminum nitride piezoelectric micromachined ultrasonic transducers using Raman spectroscopy

In this study, the Raman biaxial stress coefficients K II and strain-free phonon frequencies ω 0 have been determined for the E 2 (low), E 2 (high), and A 1 (LO) phonon modes of aluminum nitride, AlN, using both experimental and theoretical approaches. The E 2 (high) mode of AlN is recommended for the residual stress analysis of AlN due to its high sensitivity and the largest signal-to-noise ratio among the studied modes. The E 2 (high) Raman biaxial stress coefficient of ₋3.8 cm₋1/GPa and strain-free phonon frequency of 656.68 cm ₋1 were then applied to perform both macroscopic and microscopic stress mappings. For macroscopic stress evaluation, the spatial variation of residual stress was measured across an AlN-on-Si wafer prepared by sputter deposition. A cross-wafer variation in residual stress of ~150 MPa was observed regardless of the average stress state of the film. Microscopic stress evaluation was performed on AlN piezoelectric micromachined ultrasonic transducers (pMUTs) with submicrometer spatial resolution. These measurements were used to assess the effect of device fabrication on residual stress distribution in an individual pMUT and the effect of residual stress on the resonance frequency. At ~20 μm directly outside the outer edge of the pMUT electrode, a large lateral spatial variation in residual stress of ~100 MPa was measured, highlighting the impact of metallization structures on residual stress in the AlN film.

36 MATERIALS SCIENCE↗

Stress-induced nematicity in EuFe 2 As 2 studied by Raman spectroscopy

Here, we use polarized Raman scattering to study the structural phase transition in EuFe 2 As 2 , the parent compound of the 122-ferropnictide superconductors. The in-plane lattice anisotropy is characterized by measurements of the side surface with different strains induced by different preparation methods. We also show that while a fine surface polishing leaves the samples free of residual internal strain, in which case the onset of the C 4 symmetry breaking is observed at the nominal structural phase transition temperature T S , cutting the side surface induces a permanent fourfold rotational symmetry breaking spanning tens of degrees above T S .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Refractive index sensing and surface-enhanced Raman spectroscopy using silver–gold layered bimetallic plasmonic crystals

Herein we describe the fabrication and characterization of Ag and Au bimetallic plasmonic crystals as a system that exhibits improved capabilities for quantitative, bulk refractive index (RI) sensing and surface-enhanced Raman spectroscopy (SERS) as compared to monometallic plasmonic crystals of similar form. The sensing optics, which are bimetallic plasmonic crystals consisting of sequential nanoscale layers of Ag coated by Au, are chemically stable and useful for quantitative, multispectral, refractive index and spectroscopic chemical sensing. Compared to previously reported homometallic devices, the results presented herein illustrate improvements in performance that stem from the distinctive plasmonic features and strong localized electric fields produced by the Ag and Au layers, which are optimized in terms of metal thickness and geometric features. Finite-difference time-domain (FDTD) simulations theoretically verify the nature of the multimode plasmonic resonances generated by the devices and allow for a better understanding of the enhancements in multispectral refractive index and SERS-based sensing. Taken together, these results demonstrate a robust and potentially useful new platform for chemical/spectroscopic sensing.

plasmonics↗

Molecular flow velocity using Doppler shifted Raman spectroscopy

Measurements of molecular flow velocity, static pressure, and translational temperature in the free-stream of a supersonic wind tunnel and behind the shock of a simple model are reviewed. Based on the free-stream demonstration using inverse Raman spectroscopy, an experiment is outlined to investigate the lee-side flow field above a swept delta wing and simulated spectra expected for the leading-edge vortex are included. The extension of the technique to hypersonic wind tunnels is also explored through the use of simulated spectra.

Exton, Reginald J.↗

Interference-free optical detection for Raman spectroscopy

An architecture for spontaneous Raman scattering (SRS) that utilizes a frame-transfer charge-coupled device (CCD) sensor operating in a subframe burst gating mode to realize time-resolved combustion diagnostics is disclosed. The technique permits all-electronic optical gating with microsecond shutter speeds (<5 .mu.s), without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally-polarized excitation lasers, the technique measures time-resolved vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Nguyen, Quang-Viet↗

Deformations of the Heme Group of Different Ferrocytochrome c Proteins Probed by Resonance Raman Spectroscopy

We measured the low-frequency polarized resonance Raman spectra of horse heart, chicken, and yeast(C102T) ferrocytochromes c with Soret excitation. We examined the out-of-plane deformations of the heme groups by determining the relative intensities and depolarization ratios of a variety of out-of-plane and in-plane Raman active bands. Analysis of relative Raman intensities shows differences in non-planarity of the heme groups of yeast(C102T), horse heart and chicken cytochrome c. Cytochrome c has been shown to have a dominant ruffling (B{sub 1u}) deformation by means of normal coordinate structural decomposition (NSD) analysis of the heme group in crystal structures. The presence and intensity of B{sub 1u} modes, {gamma}{sub 10}-{gamma}{sub 12}, support the indication of ruffling being the major contribution to the non-planar deformations in cytochrome c. Other types of non-planar deformations like doming (A{sub 2U}) and waving (E{sub g}) can be deduced from the Raman activity of {gamma}{sub 5} (A{sub 2u}), {gamma}{sub 21} and {gamma}{sub 22} (E{sub g}). The depolarization ratios of {gamma}{sub 5}, {gamma}{sub 10}, {gamma}{sub 11} and {gamma}{sub 12} are larger than 0.125, indicating the presence of other deformations such as saddling (B{sub 2u}) and propellering (A{sub 1u}), which is again in agreement with the crystal structures of horse heart and yeast ferrocytochrome c. An analysis of the intensities and depolarization ratios of out-of-plane modes revealed that ruffling is comparable in yeast and horse heart cytochrome c, saddling is larger and doming as well as propellering are lower in yeast cytochrome c. With respect to doming and ruffling our results contradict values obtained from the NSD analysis of the corresponding crystal structures. With respect to saddling, our data are in agreement with the crystal structure. The NSD analysis of heme structures resulting from MD simulations did not correlate very well with the spectroscopically obtained results concerning the ruffling and doming coordinate, whereas a qualitative agreement was again obtained for saddling.

60 APPLIED LIFE SCIENCES↗

Functional Mn–Mg{sub k} cation complexes in GaN featured by Raman spectroscopy

The evolution of the optical branch in the Raman spectra of (Ga,Mn)N:Mg epitaxial layers as a function of the Mn and Mg concentrations, reveals the interplay between the two dopants. We demonstrate that the various Mn-Mg-induced vibrational modes can be understood in the picture of functional Mn–Mg{sub k} complexes formed when substitutional Mn cations are bound to k substitutional Mg through nitrogen atoms, the number of ligands k being driven by the ratio between the Mg and the Mn concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Classification of Ordinary Chondrites Using Raman Spectroscopy

Classification of ordinary chondrites is typically done through measurements of the composition of olivine and pyroxenes. Historically, this measurement has usually been performed via electron microprobe, oil immersion or other methods which can be costly through lost sample material during thin section preparation. Raman microscopy can perform the same measurements but considerably faster and with much less sample preparation allowing for faster classification. Raman spectroscopy can facilitate more rapid classification of large amounts of chondrites such as those retrieved from North Africa and potentially Antarctica, are present in large collections, or are submitted to a curation facility by the public. With development, this approach may provide a completely automated classification method of all chondrite types.

Fries, M.↗

Remote Sensing of Dissolved Oxygen and Nitrogen in Water Using Raman Spectroscopy

The health of an estuarine ecosystem is largely driven by the abundance of dissolved oxygen and nitrogen available for maintenance of plant and animal life. An investigation was conducted to quantify the concentration of dissolved molecular oxygen and nitrogen in water by means of Raman spectroscopy. This technique is proposed for the remote sensing of dissolved oxygen in the Chesapeake Bay, which will be utilized by aircraft in order to survey large areas in real-time. A proof of principle system has been developed and the specifications are being honed to maximize efficiency for the final application. The theoretical criteria of the research, components of the experimental system, and key findings are presented in this report

Ganoe, Rene↗

Detection and Aggregation of Listeria Monocytogenes Using Polyclonal Antibody Gold-Coated Magnetic Nanoshells Surface-Enhanced Raman Spectroscopy Substrates

Magnetic nanoshells with tailored surface chemistry can enhance bacterial detection and separation technologies. This work demonstrated a simple technique to detect, capture, and aggregate bacteria with the aid of end-functionalized polyclonal antibody gold-coated magnetic nanoshells (pAb-Lis-AuMNs) as surface-enhanced Raman spectroscopy (SERS) probes. Listeria monocytogenes were used as the pathogenic bacteria and the pAb-LisAuMNs, 300 nm diameter, were used as probes allowing facile magnetic separation and aggregation. An optimized covalent bioconjugation procedure between the magnetic nanoshells and the polyclonal antibody was performed at pH six via a carbodiimide crosslinking reaction. Spectroscopic and morphological characterization techniques confirmed the fabrication of stable pAb-Lis-AuMNs. The resulting pAb-Lis-AuMNs acted as a SERS probe for L. monocytogenes based on the targeted capture via surface binding interactions and magnetically induced aggregation. Label-free SERS measurements were recorded for the minimum detectable amount of L. monocytogenes based on the SERS intensity at the 1388 cm -1 Raman shift. L. monocytogenes concentrations exhibited detection limits in the range of 10 4 –10 7 CFU ml -1 , before and after aggregation. By fitting these concentrations, the limit of detection of this method was ~10 3 CFU ml -1 . Using a low-intensity magnetic field of 35 G, pAb-LisAuMNs aggregated L. monocytogenes as demonstrated with microscopy techniques, including SEM and optical microscopy. Overall, this work presents a label-free SERS probe method comprised of a surface-modified polyclonal antibody sub-micron magnetic nanoshell structures with high sensitivity and magnetic induced separation that could lead to the fabrication of multiple single-step sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In Situ Monitoring and Kinetic Analysis of the Extraction of Nitric Acid by Tributyl Phosphate in n-Dodecane using Raman Spectroscopy

Understanding the fundamental rates of transfer and complex formation is crucial in maintaining optimal efficiency and effectivity in solvent extraction. Methodologies to effectively analyze solvent extraction systems are lacking in that they are commonly off-line. Thus, a method to effectively investigate solvent extraction systems in a Lewis cell using in situ Raman spectroscopy paired with chemometric modelling has been developed to allow for on-line analysis and monitoring. Kinetic parameters of interfacial mass transfer for the extraction of nitric acid by tributyl phosphate, a process crucial to used nuclear fuel reprocessing, were measured in by spectroscopic monitoring of both phases simultaneously in a two-phase solvent extraction system. Resulting concentration data, derived from a chemometric model using Raman spectra as the base set, allowed for the calculation of kinetic parameters in the system when paired with extraction time. The forward and reverse interfacial mass transfer coefficients, kf and kr, were determined for solutions that were process relevant and of pro-cess interest, where kf was calculated as 5.3 (± 0.3) × 10-3 cm min 1 and kr was calculated as 2.9 (± 0.2) × 10-2 cm min-1. The information obtained regarding solvent extraction parameters and transfer can be applied in the further study of systems of higher complexity involving complex formation and their transfer across a liquid:liquid interface.

extraction, interfacial transport, Lewis Cell, Liq↗

Conical Intersection Passages of Molecules Probed by X-ray Diffraction and Stimulated Raman Spectroscopy

Conical intersections (CoIns) play an important role in ultrafast relaxation channels. Their monitoring remains a formidable experimental challenge. We theoretically compare the probing of the S 2 → S 1 CoIn passage in 4-thiouracil by monitoring its vibronic coherences, using off-resonant X-ray-stimulated Raman spectroscopy (TRUECARS) and time resolved X-ray diffraction (TRXD). The quantum nuclear wavepacket (WP) dynamics provides an accurate picture of the photoinduced dynamics. Upon photoexcitation, the WP oscillates among the Franck–Condon point, the S2 minimum, and the CoIn with a 70 fs period. A vibronic coherence first emerges at 20 fs and can be observed until the S 2 state is fully depopulated. The distribution of the vibronic frequencies involved in the coherence is recorded by the TRUECARS spectrogram. Here, the TRXD signal provides spatial images of electron densities associated with the CoIn. In combination, the two signals provide a complementary picture of the nonadiabatic passage, which helps in the study of the underlying photophysics in thiobases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation on the Ion Association Equilibria in NaNO 3 Droplets Using Micro-Raman Spectroscopy

Ion association ratios as a function of concentration were estimated in single NaNO 3 droplets (5–60 μm) on a polytetrafluoroethylene (PTFE) substrate with molar water-to-solute ratios (WSRs) of 0.8–28 and bulk NaNO 3 solutions with WSRs of 35–200 by combining micro-Raman spectroscopy and component band analysis. Concentrations of the NaNO 3 droplets were accurately controlled by adjusting relative humidity (RH) in a sample chamber. As the WSRs decreased from 200 to 0.8, symmetric stretching band (ν 1 -NO 3 –) was observed to shift from 1047 to 1058 cm –1 along with a change in full width at half-maximum (fwhm) from ~10 to ~16 cm –1 , indicative of formation of ion pairs with different structures. Through the component band analysis of the ν 1 -NO 3 – band, five bands centered at 1040.0, 1042.9, 1048.5, 1053.5, and 1057.0 cm –1 were identified and assigned to coupled wagging modes of water molecules hydrated with nitrate ions, free hydrated nitrate anions, solvent-shared ion pairs (SIPs), contact ion pairs (CIPs), and the complex ion aggregates (CIAs), respectively. There were large amounts of SIPs and CIPs in dilute NaNO 3 solution even at an extremely low concentration (WSR ~ 200), and each accounted for 50% and 20% of total nitrate species, respectively. This finding is in good agreement with earlier reported observations. In the dilute solutions (45 < WSR < 200), there is the same amount of free hydrated ions transformed into SIPs as that of SIPs transformed into CIPs. As a result, the overall amount of SIPs remained unchanged over the concentration range. With a decrease in WSR from 45 to 0.8, the amounts of SIPs and free solvated NO 3 – ions kept decreasing, whereas the amount of CIPs rose to a maximum at WSR = 7 and then fell with a further decreasing WSR. Formation of CIAs started at WSR ~ 45, and its amount continuously increased as the WSR is further reduced to 0.8. The effect of temperature on ion association structure in the NaNO 3 droplets was also studied in the present work. An increase in temperature promoted formation of both CIPs and CIAs, and the latter was more pronounced. Finally, at 80 °C, the most concentrated NaNO 3 droplets had a WSR approximately equal to 0.12 and were in amorphous state with cations and anions aggregated in a complicated manner, highly similar to ionic liquid.

Environmental Molecular Sciences Laboratory↗

In Situ Raman Spectroscopy of Uranyl Peroxide Nanoscale Cage Clusters Under Hydrothermal Conditions

Aqueous solutions containing the nanoscale uranyl peroxide cage clusters U 60 , [(UO 2 )(O 2 )(OH)] 60 60- , and U 60 Ox 30 , [{(UO 2 )(O 2 )} 60 (C 2 O 4 ) 30 ] 60- , were monitored by in situ Raman spectroscopy during stepwise heating to 180°C. In solutions with U 60 , clusters persist to 120°C, although conversion of U 60 to U 24 , [(UO 2 )(O 2 )(OH)] 24 24- , occurs above 100°C. U 60 Ox 30 persisted in solutions heated to 150°C, although partial conversion to smaller uranyl peroxide clusters species was observed beginning at 100°C. Upon breakdown of the uranyl peroxide cage clusters, uranium precipitated as a compreignacite-like phase, K 2 [(UO 2 ) 3 O 2 (OH) 3 ] 2 (H 2 O) 7 , and metaschoepite, [(UO 2 ) 8 O 2 (OH) 12 ](H 2 O) 10 . In this work, the role of the countercations, oxalate bridge, and solution pH are examined in order to better understand the mobility of these species at elevated temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonequilibrium Supersonic Freestream Studied Using Coherent Anti-Stokes Raman Spectroscopy

Measurements were conducted at the University of Virginia Supersonic Combustion Facility of the flow in a constant-area duct downstream of a Mach 2 nozzle. The airflow was heated to approximately 1200 K in the facility heater upstream of the nozzle. Dual-pump coherent anti-Stokes Raman spectroscopy was used to measure the rotational and vibrational temperatures of N2 and O2 at two planes in the duct. The expectation was that the vibrational temperature would be in equilibrium, because most scramjet facilities are vitiated air facilities and are in vibrational equilibrium. However, with a flow of clean air, the vibrational temperature of N2 along a streamline remains approximately constant between the measurement plane and the facility heater, the vibrational temperature of O2 in the duct is about 1000 K, and the rotational temperature is consistent with the isentropic flow. The measurements of N2 vibrational temperature enabled cross-stream nonuniformities in the temperature exiting the facility heater to be documented. The measurements are in agreement with computational fluid dynamics models employing separate lumped vibrational and translational/rotational temperatures. Measurements and computations are also reported for a few percent steam addition to the air. The effect of the steam is to bring the flow to thermal equilibrium, also in agreement with the computational fluid dynamics.

Cutler, Andrew D.↗