Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK

At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer which maintains sensitivity to 5 mK. A key component of this thermometer is an in situ radio frequency filter which is based on a modern rf absorption material. Here, we show that the use of such a filter is only effective when it is encased in the same rf-tight enclosure as the ruthenium oxide sensor. Our design delivers an attenuation level that is necessary to mitigate the effects of parasitic heating of a fraction of pW present in our circuit. Furthermore, we show that the likely origin of this parasitic heating is the black body radiation present within the experimental space of the refrigerator. We found that the equilibration time of the thermometer increases rapidly as the temperature is lowered; below 5 mK this thermometer becomes impractical because of the prohibitively long equilibration times.

47 OTHER INSTRUMENTATION↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Implantable photoelectronic charging (I-PEC) for medical implants

Medical implants with functionalities such as sensing, health monitoring, stimulation, diagnosis, and physiological treatment are rapidly growing. With the increasing functional sophistication and addition of modules such as data transmission, on-chip processing, and data storage, energy demand of the implantable system is also growing. Using implantable energy harvester either to recharge or ultimately replace hazardous battery is essential to provide a long-term sustainable solution. Furthermore, energy harvesting techniques using piezoelectric, thermoelectric, radio frequency power transmission, biofuel, and photoelectronic (or sometimes termed as “photovoltaic” in terms of solar light harvesting, i.e., PV) conversion, have been attempted for the implantable, but these methods are currently limited by insufficient power output, large footprint, and low efficiency. Nevertheless, the planar PV with potential of lighter weight, higher energy density, and higher efficiency, provides promising power solution for in-body medical implants. In this short review, we will discuss the potential opportunities and challenges associated with PV's for medical implants, covering materials, to devices, and to system level requirements.

60 APPLIED LIFE SCIENCES↗

Micromovements and discomfort associated with flight mission with helmet operation tasks with different levels of cognitive workload

When performing stationary tasks under elevated cognitive workload, individuals must perform continual muscle contractions to maintain stability of the body, resulting in fatigue of the postural muscles. When the muscles perform these contractions in a prolonged manner, the body potentially responds through small changes in body movements—micromovements that may lead to discomfort. The study purpose was to evaluate impact of cognitive load on micromovements. The micromovements were measured during three different cognitive workloads; low, medium, and high. The NASA-TLX score was used to evaluate the perceived mental workload and discomfort was assessed by visual analog scale. In total, 60 subjects (30 males and 30 females) were recruited and performed cognitive tasks that simulated flight operations such as changing the radio frequency based on air traffic control messages, balancing the fuel levels in simulated fuel tanks, and aiming a reticle in a designated moving target using the cyclic control. Cognitive load was defined by the frequency of events. Micromovements were defined by changes in the center of pressure (COP) of the seat pan and COP standard deviation. It was found that the high cognitive workloads had the highest NASA-TLX scores including mental demands, temporal demands, and effort. The neck area had the highest overall levels of discomfort followed by upper back. The highest standard deviation for COP shift and number of micromovements occurred for medium cognitive workloads. In conclusion, while there were some interesting trends, few trends reached a statistical significance due to high variability among subjects for the outcome variables.

60 APPLIED LIFE SCIENCES↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hypervelocity impact flash expansion geometry under various spacecraft surface electrical conditions

A more congested space environment due to increasing space activities introduces new threats to spacecraft operators. Among these threats include hypervelocity impacts from microparticles (< 1 µg) in the form of meteoroids and space debris. These microparticles travel at speeds between 11.2 and 72.8 km/s with respect to the Earth and can impact spacecraft forming a small (~1 µm) and dense (~ 10 26 m -3 ) plasma. This plasma can generate a strong optical emission (impact flash) and a radio frequency (RF) emission. These emissions can lead to spacecraft electrical anomalies when the impacted spacecraft surface (target) carries high electrical potential due to various space weather effects. To understand the microparticle hypervelocity impact plasma and its associated threat to spacecraft electronics, we studied the hypervelocity impact flash expansion geometry under various spacecraft surface electrical conditions. Three high-speed broadband photomultiplier tubes (PMT) are used to capture the temporal evolution of the impact flash and the temporal evolution of the angular distribution of the impact flash expansion geometry in a 3 MV electrostatic dust accelerator during a ground-based experiment. Overall, results indicate that the impact surface electrical condition has a statistically significant influence on the impact flash geometry, and a strong similarity between the impact plasma and flash expansion geometry. Thus, this paper provides new experimental support for the impact flash origin from and connection with the impact plasma, and serves as the first impact flash expansion geometry characterization under various impact surface electrical conditions in a collisionless environment (< 10 -5 Torr).

42 ENGINEERING↗

Dehydration of gas-phase benzyl amine alcohols studied at atmospheric pressure

Gas-phase ion chemistry is a useful approach for the investigation of physical organic chemistry and the study of reactivity, structure, and thermochemical properties of ionic and neutral organic substrates. Herein, one-step dehydration of gas-phase benzyl amine alcohols to give benzazetidines was discovered without the use of catalysts. Mechanistic investigations of the gas-phase dehydration reactions were explored to study the possible influence of charged microdroplet acceleration during electrospray ionization (ESI) and collisions occurring during ion transfer through the atmospheric pressure interface (API) of the mass spectrometer. The product ion distribution was observed to be less sensitive to droplet effects (spray distance and voltage), and temperature of transfer capillary in the API. However, the product ion distribution exhibit high sensitivity to different S-lens radio frequency (RF) voltage of the API, providing evidence that the dehydration reaction is driven by collisions during ion transfer in the API. With this insight, we developed atmospheric pressure thermal dissociation platform that allowed thermal-induced collisions outside of the mass spectrometer when the benzyl amine alcohols are carried through a heated coiled tube. Up to 98% dissociation efficiency was achieved with the coiled tube heated to a temperature of 200 °C, yielding only the desired benzazetidine product. Finally, by performing the atmospheric pressure thermal dissociation experiment outside of the mass spectrometer, we believe it will be straightforward to collect the dehydration product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An explicit scheme to enforce charge conservation in transient Particle-in-Cell simulations with Maxwell-Boltzmann electrons

The Maxwell-Boltzmann electron model is a very popular approximation of the electronic behavior in electrostatic plasmas, adopted in all cases where the electron dynamics is governed only by a balance between electric and pressure forces. In such a model, the electron dynamics is reduced to solving for a nonlinear Poisson problem together with an additional expression enforcing charge conservation. In this work we derive an expression of charge conservation which can be conveniently applied to explicit schemes to update the reference Boltzmann density, particularly useful when simulating plasma sheaths. The scheme can be equally applied to both steady-state and transient problems. Two examples are shown, a steady-state plasma sheath, and a radio-frequency magnetic presheath. Our proposed scheme allows to enforce global charge conservation locally in time, and can thus be applied to the simulation of transient phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applications of plasma-enhanced metalorganic chemical vapor deposition

The use of plasma enhancement for growth of III-V compound semiconductor materials by metalorganic chemical vapor deposition (MOCVD) is examined, to improve control of microstructure, develop understanding of the underlying growth mechanisms, and expand the range of materials combinations for photovoltaic and solid-state lighting applications. Whereas plasma is commonly used with group-IV materials, such as silicon, few studies have examined the impact of plasma-enhanced MOCVD (PE-MOCVD) for III-V materials growth. PE-MOCVD provides improved decomposition of metalorganic precursors, which is driven by hydrogen plasma to augment hydride reactions and thermal pyrolysis, but plasma generation requires low reactor pressure. We have demonstrated elemental Al films grown by PE-MOCVD, which show distinct crystallographic texturing, and assume epitaxial microstructure upon post-growth annealing. We also demonstrate PE-MOCVD of GaAs at temperatures as low as 300 °C. With increasing radio-frequency power, the GaAs growth rate shows a transition from power limited to mass-transport limited. PE-MOCVD grown Ga 0.5 In 0.5 P shows no detectable spontaneous atomic ordering, which offers a mechanism to form order/disorder unicompositional heterostructures, without temperature change or impurity incorporation. In its current implementation, PE-MOCVD grown films have shown microstructural degradation, that we attribute to direct plasma exposure during growth. Improvements in the system design and growth sequences are at the focus of on-going efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetism and spin-dependent transport phenomena across Verwey and Morin transitions in iron oxide/Pt bilayers

Understanding the influence of phase coexistence and phase transitions on spin transport properties in a ferromagnet/heavy metal (FM/HM) system is of utmost importance for spintronics. Here, we report a comprehensive investigation of the magnetic and spin transport properties of biphase iron oxide (BPIO = α-Fe 2 O 3 +Fe 3 O 4 )/Pt films over a wide temperature range, 10K ≤ T ≤ 300K. In-plane (IP) and out-of-plane (OOP) magnetometry and radio frequency transverse susceptibility measurements confirm the characteristic features of the Verwey and Morin transitions at T V ~ 120K and TM ~ 200 K, respectively. Further, anisotropic magnetoresistance (AMR) is observed in the BPIO film, which arises mainly from the spin polarized tunneling of conduction electrons between neighboring uniformly magnetized grains through the resistive grain boundary. Spin Hall magnetoresistance (SMR) and spin Hall anomalous Hall effect (SH-AHE) are detected in the BPIO/Pt films. Around the T V , the temperature evolution of SMR shows a sharp maximum, while SH-AHE exhibits a steep decrease. Both SMR and SH-AHE are strongly susceptible to the Verwey transition but the Morin transition, indicating that the interfacial magnetism of our BPIO/Pt film is dominated by the Fe 3 O 4 phase rather than the α-Fe 2 O 3 phase.

36 MATERIALS SCIENCE↗

Complex multicomponent spectrum analysis with Deep Neural Network

Here, in this paper, we present the use of deep neural networks to estimate physical parameters from complex optical emission spectra of the D β /H β transition. Specifically, we focus on estimating the radio frequency electric field vector of the lower hybrid wave and isotope ratio within the scrape-off-layer plasma of the WEST tokamak. Fitting the spectral data using a traditional non-linear least squares analysis requires many free parameters and is computationally expensive, rendering the data unusable for real-time control. By implementing relatively small neural networks, the physical parameters can be directly extracted from the spectral data with reasonable accuracy in a few milliseconds. The deep neural network prediction can serve as input for a reduced model using least-squares fitting or for real-time control. We show that deep neural networks can be an effective tool for analyzing complex multicomponent spectra, providing a speedup of more than 10 5 times compared to least residual analysis, with an accuracy of 0.5% for the isotope ratio, and 0.09 kV/cm and 0.38 kV/cm for the RF radial and poloidal electric field respectively.

47 OTHER INSTRUMENTATION↗

Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump

Pressure spikes in the fundamental power coupler waveguide are a significant source of trips during the operation of both original and refurbished superconducting radio-frequency cavities installed in the CEBAF accelerator. In its original configuration, two waveguides from a cavity-pair are connected to a single 32 l/s ion pump. In 2017 a new cavity-pair was installed in a refurbished cryomodule in which a NEXTorr® D200-5 combination ion pump and non-evaporable getter pump was installed for each waveguide. It is shown that hydrogen is the dominant residual gas in the waveguide and simulations with Molflow+ indicated that the new pumping scheme allows reducing the pressure at the end of the waveguide by a factor of ~5 , compared to the original configuration. In conclusion, the new cavity-pair has been operating in CEBAF for a total of 431 days and it only had a total of 3 trips due to vacuum spikes in the waveguide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Certification testing of production superconducting quarter-wave and half-wave resonators for $\mathrm{FRIB}$

We report the Facility for Rare Isotope Beams (FRIB) is designed to accelerate ion beams to 200 MeV per nucleon with 46 superconducting radio-frequency cryomodules. The FRIB driver linac uses quarter-wave resonators and half-wave resonators; with a total of 324 resonators, the linac is currently the largest heavy ion accelerator in the world. Production of jacketed resonators began in January 2014 and was completed in December 2019. Dewar certification testing of all the cavities was done before they were installed into cryomodules. The experience and lessons from more than 5 years of FRIB resonator production and certification testing are analyzed and summarized in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗

A pathway to synthesizing single-crystal Fe and FeCr films

Nuclear reactor environments provide a unique scientific and engineering challenge wherein materials must tolerate prolonged exposure to concurrent irradiation, elevated temperatures, and corrosive media. However, uncontrolled variability in material composition and structure often prohibits truly single-variable experiments that can reveal basic aspects of environmental damage. Here, Magnetron sputtering is used to provide a more controlled model system for these fundamental studies, yielding reproducible single-crystal Fe and FeCr thin films containing 8 and 18 at.% Cr. Electron microscopy is used to determine the systematic correlations between growth conditions and the resulting film microstructure and surface morphology. It is found that the substrate temperature and applied radio frequency (RF) bias can be tuned to obtain consistent homogeneous and single crystal films with a minimal amount of Ar impurities from the RF bias process. Epitaxial, single-crystal Fe films are obtained on MgO substrates at 500 °C with 10 Watt (W) RF bias deposition. However, when Cr is alloyed with Fe, higher substrate temperatures (600 °C) and applied RF biases (15 W) are required to achieve a similar epitaxial single-crystal FeCr film. Accelerated molecular dynamics simulations reveal that Cr impedes surface transport, explaining the need for higher temperature and bias during the growth of the Cr-bearing films.

36 MATERIALS SCIENCE↗