Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Scintillators

As concerns about the illicit movement of radioactive materials across international borders increase, so too has the need for increased protection of those borders both foreign and domestic. The challenge is not only to detect hidden radioactive materials, but also to distinguish them from legitimate radionuclides such as radio-pharmaceuticals that are often transported across borders and shipped throughout a country. With more than 600 U.S. border sites to protect, screening imported radioactive material requires a careful balance of high throughput and high search efficiency. However, these requirements are difficult to meet as rapid screening operations leave less time for radiation detectors to efficiently evaluate materials. In support of border security, Sandia developed organic glass scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor

This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hybrid Metal Halides: Advancing Optoelectronic Materials (Final Technical Report)

Hybrid metal halides, particularly main group halide perovskites, are a unique class of materials that offer exceptional optoelectronic properties along with a remarkable materials design space. Initial research on this class of materials was driven by the ability of the prototype hybrid 3D perovskite-structured compound methylammonium lead iodide to function as the active layer in thin film solar cells. It is now known that this class of materials comprise a large family with tunable band gaps, relatively high charge carrier mobilities in both single crystal and polycrystalline forms, and relatively low concentrations of (deleterious) electrically active states within the band gap. Beyond applications in solar cells, the potential of these materials has been extended to emitters in light emitting diodes, and active components of radiation detectors. Complementing new functionality, the design space for hybrid metal halides continues to increase with discovery of new structural motifs. In this project, the combination of organic and inorganic functionalities has been employed to open pathways to the design and synthesis new, functional hybrid metal halides. Beyond the simple perovskites, Ruddlesden-Popper and Dion-Jacobsen compounds, and other variants, such as the newly advanced “hollow” perovskites have been studied. The materials have provided routes to understanding the unique electronic properties of hybrid metal halides because of their natural quantum well structures as well as other means of controlling band gaps and band dispersions. Understanding these materials, including the design rules for their formation, their structures and compositions in bulk and in thin films form, and the role of local (non-crystallographic) structure has an important aspect of this endeavor. The goal of advancing new materials and new fundamental understanding within this deceptively simple, yet fascinating class of compounds, so richly endowed with interesting and useful functionality, has been fulfilled.

36 MATERIALS SCIENCE↗

Discriminator Threshold Study for Scint 1

During electronics testing at NSRL, the fluence/spill is recorded from the QC1 chamber. This chamber, which is a permanent fixture on the NSRL beamline, requires calibration from an external radiation detector that can measure ion flux directly. A 1.0 × 1.0 × 0.5 cm 3 scintillator is used at the testing location to calibrate all NSRL beams for electronic experiments. A calibration factor is derived by comparing the ions observed by the scintillator and QC1 during an exposure of at least 10 5 scintillator counts or total ions.

43 PARTICLE ACCELERATORS↗

Fulcrum Behavior Investigation

A summary of the issues that have come up in the use of the fulcrum radiation detector and the methods tools that I developed to deal with them.

Albiani, Nicolas B↗

External Radiation and Magnetic-Field Effects on the Coherence and Stability of Transmon Qubits

Superconducting transmon qubits are a central building block of modern quantum computing architectures, yet their coherence properties remain sensitive to external influences that can limit performance or introduce temporal instabilities. In this talk, I will discuss two experimental studies aimed at quantifying these effects. First, I will examine how ionizing radiation impacts qubit relaxation. Using the same transmon device operated at two locations with dramatically different radiation backgrounds—the above-ground SQMS facility at Fermilab (USA) and the deep-underground Gran Sasso Laboratory (Italy)—we observe a higher rate of radiation-induced decay events above ground, even though intrinsic noise remains the dominant source of single-shot errors. I will also discuss the detection efficiency of a radiation detector made using such a device. Second, I will present results on how small magnetic fields, applied either during cooldown or at millikelvin temperatures, influence device stability. We find that fixed-frequency transmons maintain robust coherence up to approximately 600 mG of trapped out-of-plane field, and that controlled application of magnetic field can reduce temporal fluctuations in T1. Together, these studies provide insight into how external environments shape transmon coherence and offer potential pathways for improving qubit stability in scalable quantum processors.

Roy, Tanay [Fermilab]↗

ORNLERASE - EPA COUNTS PER MINUTE CALCULATOR CONVERSION FACTORS

This database is used in the EPA's Superfund Counts Per Minute (CPM) Calculator (https://epa-cpm.ornl.gov/index.html). This database contains conversion factors used in the calculator that help users estimate the expected radiation detector reading, in counts per minute (CPM), corresponding to a measured radioactivity level reported in either pCi/cm² or pCi/g. Because surface contamination and volumetric contamination behave differently, the tool uses separate conversion processes, each based on Monte Carlo N-Particle (MCNP)–derived conversion factors. The CPM Calculator supports conversions for a range of common environmental media—including soil, steel, glass, drywall, concrete, and wood—to generate detector-ready CPM values. The primary goal of this tool is to enable more efficient, real-time field measurements, reducing reliance on laboratory analyses and ultimately saving both time and money during Superfund assessments.

Dolislager, Fred [ORNL] (ORCID:0009000325477921)↗

Mobility Monitoring System For Ecological Studies

Radioactive-nuclide system automatically monitors animals in the field, using radioactive tracers affixed to the animals, Geiger-Muller tube radiation detectors, and event-recorders. Four animals can be monitored simultaneously within a 32-m circle, with each animal as far as 1 m from its associated detector.

Eisler, W. J., Jr.↗

Improved heat shield/radiator

Thermally conductive metal shield is put in direct thermal contact with the mounting plate for the radiation detectors. External surfaces of the shield are insulated by an insulation blanket. The internal faces are covered with a thin layer of quartz with a metallic thermally conductive coating on the hidden faces.

Smith, J. W.↗

Research in space physics

Corpuscular radiation in outerspace determined by radiation detector data from aerospace vehicles

Van Allen, J. A.↗