Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Wafer characteristics via reflectometry

Various exemplary methods (800, 900, 1000, 1100) are directed to determining wafer thickness and/or wafer surface characteristics. An exemplary method (900) includes measuring reflectance of a wafer and comparing the measured reflectance to a calculated reflectance or a reflectance stored in a database. Another exemplary method (800) includes positioning a wafer on a reflecting support to extend a reflectance range. An exemplary device (200) has an input (210), analysis modules (222-228) and optionally a database (230). Various exemplary reflectometer chambers (1300, 1400) include radiation sources positioned at a first altitudinal angle (1308, 1408) and at a second altitudinal angle (1312, 1412). An exemplary method includes selecting radiation sources positioned at various altitudinal angles. An exemplary element (1650, 1850) includes a first aperture (1654, 1854) and a second aperture (1658, 1858) that can transmit reflected radiation to a fiber and an imager, respectfully.

Sopori, Bhushan L↗

Special Analysis for the Disposal of the Oak Ridge National Laboratory General Radioactive Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This special analysis (SA) evaluates whether the Oak Ridge National Laboratory (ORNL) General Radioactive Sources waste stream (ORNLSOURCES01, Revision 3) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site (NNSS). The ORNL General Radioactive Sources waste stream consists of sealed sources and solid radioactive sources that are no longer needed (ORNL 2015). The ORNL General Radioactive Sources waste stream required a special analysis because 26 radionuclides exceeded the NNSS Waste Acceptance Criteria (WAC) Action Levels (U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office [NNSA/NFO] 2015). However, review of the generator’s method to calculate waste concentration indicates that the concentrations are significantly overestimated. Waste concentrations are recalculated in this analysis using a list of individual sources provided by the generator. One radionuclide, radium-226 (226Ra), still exceeds its action level and a Special Analysis (SA) is required. The results indicate that all performance objectives can be met with disposal of the ORNL General Radioactive Sources in a SLB trench. Addition of the ORNL General Radioactive Sources inventory slightly increases the 222Rn flux density. The maximum mean and 95th percentile flux density remain less than the performance objective throughout the compliance period. The ORNL General Radioactive Sources waste stream had no significant effect on the maximum mean and 95th percentile for all other performance assessment results. The ORNL General Radioactive Sources waste stream is suitable for disposal by SLB at the Area 5 RWMS. However, because the activity concentrations on the waste profile sheet are significantly overestimated, approval of the sheet could potentially allow the disposal of high activity radiation sources. To ensure the generator does not include large radiation sources in its waste stream, a control is recommended on the maximum individual source activity from this generator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management of Disused Sealed Sources in Austria - 12147

The use of sealed radiation sources is regulated by the Austrian Radiation Protection Act and the General Radiation Protection Ordinance. The Austrian radiation protection legislation requires minimisation of radioactive waste. The preferred radioactive waste management option concerning sealed sources, both spent and disused, is the return to the manufacturer. If this is not possible a reuse by a third party is encouraged. According to this requirement, disused sealed sources shall, as far as possible, be stored on the site of the licence holder until a new owner is found. If this is not possible, disused sealed sources shall be transported to Nuclear Engineering Seibersdorf, which is a recognised storage facility for radioactive waste in Austria, for temporary storage pending reuse. Sources, which cannot be reused, are declared as radioactive waste. Since Austria is a Member State of the European Union, the Council Directive 122/2003/Euratom on High Activity Sealed Sources and Orphan Sources is applied. This directive defines high activity sealed sources on the basis of their total activity. The possession of such sources is subject to certain obligations. Therefore it is in the interest of the owner to return disused sources as soon as possible to the manufacturer or to deliver them to Nuclear Engineering Seibersdorf. In case of the loss and finding of an 'orphan' source the competent authority secures, recovers and stores the source at the cost of the owner of the source with recourse. In line with the directive the licensee of a High Activity Sealed Source has to notify the main data concerning this source to the Central Source Register which is maintained by the Federal Minister of Agriculture, Forestry, Environment and Water Management for all radioactive sources. This register was put into operation in 2006. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Vacuum space-charge effects in solid-state photoemission

Solid-state photoemission spectroscopy relies to a large part on pulsed photon sources: third-generation synchrotron-radiation sources and ultrafast laser systems in particular. Especially when the photon pulses are intense, Coulombic repulsion between the emitted electrons will be a limiting factor for photoemission experiments aiming at highest energy and angle resolutions. In the present work, the propagation of the photoelectron cloud to the detector is studied with a full N-body numerical simulation. The influence of various parameters, in particular number of electrons per pulse, source size, pulse duration, kinetic-energy and emission-angle distributions as well as presence of mirror charges in the sample, is investigated in detail. Previous experimental results obtained with various picosecond and femtosecond light sources are successfully reproduced and the general resolution limits of solid-state photoemission using pulsed photon sources are explored. The results are potentially important for the design and interpretation of photoemission experiments with next-generation light sources, such as free-electron lasers and high-harmonic generation sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nested multilayered X pinches for generators with mega-ampere current level

A symmetric X pinch configuration that is conducive to using large numbers of wires on {>=}1 MA pulsed power generators has been tested at 1 MA. Using an initial configuration of wires before their twisting, similar to nested cylindrical wire arrays, enables a geometrically simple, compact, multilayer wire configuration at the X pinch crossing region. Multilayer X pinches with the same or different materials in the inner and outer wire layers were tested. Optimization resulted in X pinch radiation sources with peak power comparable to the most successful single layer X pinch, but with a compact, single bright X radiation source more reliably obtained using the nested configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancements in Afterbody Radiative Heating Simulations for Earth Entry

Four advancements to the simulation of backshell radiative heating for Earth entry are presented. The first of these is the development of a flow field model that treats electronic levels of the dominant backshell radiator, N, as individual species. This is shown to allow improvements in the modeling of electron-ion recombination and two-temperature modeling, which are shown to increase backshell radiative heating by 10 to 40%. By computing the electronic state populations of N within the flow field solver, instead of through the quasi-steady state approximation in the radiation code, the coupling of radiative transition rates to the species continuity equations for the levels of N, including the impact of non-local absorption, becomes feasible. Implementation of this additional level of coupling between the flow field and radiation codes represents the second advancement presented in this work, which is shown to increase the backshell radiation by another 10 to 50%. The impact of radiative transition rates due to non-local absorption indicates the importance of accurate radiation transport in the relatively complex flow geometry of the backshell. This motivates the third advancement, which is the development of a ray-tracing radiation transport approach to compute the radiative transition rates and divergence of the radiative flux at every point for coupling to the flow field, therefore allowing the accuracy of the commonly applied tangent-slab approximation to be assessed for radiative source terms. For the sphere considered at lunar-return conditions, the tangent-slab approximation is shown to provide a sufficient level of accuracy for the radiative source terms, even for backshell cases. This is in contrast to the agreement between the two approaches for computing the radiative flux to the surface, which differ by up to 40%. The final advancement presented is the development of a nonequilibrium model for NO radiation, which provides significant backshell radiation at velocities below 10 km/s. The developed model reduces the nonequilibrium NO radiation by 50% relative to the previous model.

Johnston, Christopher O.↗

Handling radiation generated during an ion source commissioning

Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H{sup +} ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D{sup +} beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.

43 PARTICLE ACCELERATORS↗

Status and Prospects of Coherent Light Source Developments at UVSOR-II

We are developing coherent light sources at the UVSOR-II electron storage ring. We have developed a resonator type free electron laser in the visible to the deep UV range, coherent harmonic generation source in VUV range and coherent synchrotron radiation source in the terahertz range. A new five year plan has been started from FY2008, where a new 4m straight section will be created by moving the beam injection point, a new optical klystron type undulator will be installed and dedicated beam-lines will be constructed. Great advances on the coherent light source developments at the new straight section are expected.

43 PARTICLE ACCELERATORS↗

Acoustic radiation from sources convected at transonic speeds

Each supersonic jet contains a long segment of transonic flow, and it is known through acoustic experiments that the strongest noise production region is embedded in this segment. The linearized convected wave equation breaks down in the transonic regime and a nonlinear equation must be used. Amplitude, directivity, and the transonic similarity rule for noise radiation can be established through proper matching of the displacement amplitude between the source and the wave field. This paper is a first step towards establishing a general theory of transonic aeroacoustics.

Pao, S. P.↗

Elongation of extreme ultraviolet (at 13.5 nm) emission with time-of-flight controlled discharges and lateral fuel injection

A way toward a quasicontinuous extreme ultraviolet (EUV) radiation source is proposed and explored. Tin and lithium vapor discharges with the lateral laser-ablation injection are experimentally studied as possible efficient sources of quasicontinuous emission of EUV radiation at a wavelength of 13.5 nm. It is shown that the time-of-flight control of optimal plasma parameters by means of varying ablating laser pulse parameters provides a considerable elongation of maximal-power EUV emission with an overall efficiency of 0.1% and with an energy output exceeding 1% of the energy deposited in the discharge plasma. Along with a high average power and a stable position, such an emitter may have its size small enough to be used in the projection lithography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatially Resolved Elemental Analysis, Spectroscopy and Diffraction at the GSECARS Sector at the Advanced Photon Source

X‐ray microprobes (XRM) coupled with high‐brightness synchrotron X‐ray facilities are powerful tools for environmental biogeochemistry research. One such instrument, the XRM at the Geo Soil Enviro Center for Advanced Radiation Sources Sector 13 at the Advanced Photon Source (APS; Argonne National Laboratory, Lemont, IL) was recently improved as part of a canted undulator geometry upgrade of the insertion device port, effectively doubling the available undulator beam time and extending the operating energy of the branch supporting the XRM down to the sulfur K edge (2.3 keV). Capabilities include rapid, high‐resolution, elemental imaging including fluorescence microtomography, microscale X‐ray absorption fine structure spectroscopy including sulfur K edge capability, and microscale X‐ray diffraction. These capabilities are advantageous for (i) two‐dimensional elemental mapping of relatively large samples at high resolution, with the dwell times typically limited only by the count times needed to obtain usable counting statistics for low concentration elements, (ii) three‐dimensional imaging of internal elemental distributions in fragile hydrated specimens, such as biological tissues, avoiding the need for physical slicing, (iii) spatially resolved speciation determinations of contaminants in environmental materials, and (iv) identification of contaminant host phases. In this paper, we describe the XRM instrumentation, techniques, applications demonstrating these capabilities, and prospects for further improvements associated with the proposed upgrade of the APS. Core Ideas X‐ray microprobes are powerful tools for environmental biogeochemistry. Upgraded GSECARS XRM operates down to the sulfur K edge. Capabilities: spatially resolved elemental analysis, spectroscopy, and diffraction. Advanced Photon Source upgrade will further advance XRM capabilities.

Sutton, Stephen R.↗

Examples of Use of SINBAD Database for Nuclear Data and Code Validation

Benchmark experiments can serve several purposes and the availability of suitable experimental data is fundamental to ensure that modelling tools meet the requirements of nuclear industry and licensing needs. Essentially, they are used for: - validation of nuclear cross-section data, - validation of nuclear codes and models used, - qualification and training of users through benchmarking and code comparison exercises. The Shielding Integral Benchmark Archive and Database (SINBAD) project was started in the early 1990's at the OECD Nuclear Energy Agency Data Bank (NEA DB) and the Radiation Safety Information Computational Center (RSICC) as a collection of quality experiments for validating and benchmarking computer codes and data for radiation transport and shielding applications. Currently, the SINBAD database comprises over 100 benchmark compilations and evaluations of relevance to: - reactor shielding, pressure vessel dosimetry (48); - fusion blanket neutronics (31); - accelerator shielding (23). In order to facilitate their use, the data are organized in the standardized format structure. The index and the master document (called abstract) use the Hyper Text Markup Language (HTML) format with links to text files, figures, Portable Document Format (pdf) documents and computer code inputs. The format allows easy access and forward/backward navigation among the data and has proved to be suitable, general enough and above all easy (and low-cost) to maintain. In addition to the characterization of the radiation source, description of the shielding set-up, the instrumentation and the relevant detector measurements, most sets in SINBAD contain also the deterministic or Monte Carlo radiation transport computer model used for the interpretation of the experiment and, where available, results from uncertainty analysis. The set of primary documents used for the benchmark compilation and evaluation are provided in computer readable form. The database is intended for different types of users, including nuclear data evaluators, computer code developers, experiment designers and university students. SINBAD is available from the NEA Data Bank and RSICC (see https://www.oecdnea.org/science/wprs/shielding/sinbad/). Up to now several hundreds of SINBAD packages were distributed from the NEA DB and RSICC. Since 2011 the maintenance and further development of the database is coordinated in the scope of the OECD NEA Nuclear Science Committee (NSC) Working Party on Scientific Issues of Reactor Systems (WPRS) Expert Group on Radiation Transport and Shielding (EGRTS). A key objective of the group is to identify, evaluate and preserve experimental data on shielding benchmarks. The Expert Group maintains close links with the International Reactor Physics Experiment Evaluation (IRPhE) and International Criticality Safety Benchmark Evaluation (ICSBEP) projects, as well as in co-ordination with the JEFF and EFF NEA Data Bank projects and with the SATIF community of accelerator shielding specialists. In the last years, much effort was devoted to the quality review of the available benchmark information.

42 ENGINEERING↗

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

Integration of the ITER Tokamak C-model with the Building Model

The pellet injector system is designed to accommodate the requirement of continuous plasma refueling during ITER Tokamak operations. Through pellet flight tubes/injection lines, the pellets can directly reach the interior of the tokamak vacuum vessel. The pellet injector system is located at a port cell outside of the Tokamak bio-shield. The plasma radiation source in the tokamak vacuum vessel, together with the highly activated surrounding water in port cells, present major radiation challenges for the pellet injector system during ITER operation and after shutdown. These sources produce a radiation field encompassing the entire Tokamak complex. The ITER neutronics reference model C-model is an ITER radiation transport model. It represents a 40 deg. regular torus sector out to the bio-shield, which consists of 38 individual systems. The Monte Carlo N-Particle (MCNP) input of the C-model consists of more than a hundred thousand cell definitions and surface definitions, and over three hundred material compositions. The latest tokamak complex MCNP model is significantly more detailed than any previous releases. It consists of 36,863 cell definitions, 57,105 surface definitions, and a total of 21 different types of materials. The C-model and tokamak building model share the bio-shield as the boundary between them. In general, the radiation fields in the building due to the plasma source during tokamak operation are determined by generating the radiation source in the inner faces of the bio-shield. An inherent limitation of this approach is that it can only approximate the directions in which streaming paths are produced through the bio-shield plugs. To better estimate the shutdown dose rate for the pellet injector system due to the plasma source, we have decided to integrate the tokamak model (C-model) with the complex building model. Both MCNP models are provided by the ITER International Organization (IO) to the Oak Ridge National Laboratory (ORNL) Radiation Transport (RT) group.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Doppler radar observation of thunderstorm circulation in the 1977 trip program

Storm data obtained on August 1, 1977 are examined in an attempt to interpret the relationship between lightning occurrence and the thunderstorm inner dynamics and precipitation processes. Horizontal maps are presented which indicated the position of radiation sources detected by the Lightning Detection and Ranging (LDAR) network, together with the horizontal motion fields and radar reflectivity data. Detailed inspection of these fields showed that, although radiation sources are found in the vicinity of precipitation cells, they are not located in the heavy precipitation areas, but rather on their rear side in regions where the configuration of the wind fields suggests the presence of updrafts.

Lhermitte, R. M.↗

Mortality Among Mound Workers Exposed to Polonium-210 and Other Sources of Radiation, 1944–1979

Polonium-210 is a naturally occurring radioactive element that decays by emitting an alpha particle. It is in the air we breathe and also a component of tobacco smoke. Polonium-210 is used as an anti-static device in printing presses and gained widespread notoriety in 2006 after the poisoning and subsequent death of a Russian citizen in London. More is known about the lethal effects of polonium-210 at high doses than about late effects from low doses. In this paper, cancer mortality was examined among 7,270 workers at the Mound nuclear facility near Dayton, OH where polonium-210 was used (1944–1972) in combination with beryllium as a source of neutrons for triggering nuclear weapons. Other exposures included external gamma radiation and to a lesser extent plutonium-238, tritium and neutrons. Vital status and cause of death was determined through 2009. Standardized mortality ratios (SMRs) were computed for comparisons with the general population. Lifetime occupational doses from all places of employment were sought and incorporated into the analysis. Over 200,000 urine samples were analyzed to estimate radiation doses to body organs from polonium and other internally deposited radionuclides. Cox proportional hazards models were used to evaluate dose-response relationships for specific organs and tissues. Vital status was determined for 98.7% of the workers of which 3,681 had died compared with 4,073.9 expected (SMR 0.90; 95% CI 0.88–0.93). The mean dose from external radiation was 26.1 mSv (maximum 939.1 mSv) and the mean lung dose from external and internal radiation combined was 100.1 mSv (maximum 17.5 Sv). Among the 4,977 radiation workers, all cancers taken together (SMR 0.86; 95% CI 0.79–0.93), lung cancer (SMR 0.85; 95% CI 0.74–0.98), and other types of cancer were not significantly elevated. Cox regression analysis revealed a significant positive dose-response trend for esophageal cancer [relative risk (RR) and 95% confidence interval at 100 mSv of 1.54 (1.15–2.07)] and a negative dose-response trend for liver cancer [RR (95% CI) at 100 mSv of 0.55 (0.23–1.32)]. For lung cancer the RR at 100 mSv was 1.00 (95% CI 0.97–1.04) and for all leukemias other than chronic lymphocytic leukemia (CLL) it was 1.04 (95% CI 0.63–1.71). There was no evidence that heart disease was associated with exposures [RR at 100 mSv of 1.06 (0.95–1.18)]. Assuming a relative biological effectiveness factor of either 10 or 20 for polonium and plutonium alpha particle emissions had little effect on the dose-response analyses. Polonium was the largest contributor to lung dose, and a relative risk of 1.04 for lung cancer at 100 mSv could be excluded with 95% confidence. A dose related increase in cancer of the esophagus was consistent with a radiation etiology but based on small numbers. A dose-related decrease in liver cancer suggests the presence of other modifying factors of risk and adds caution to interpretations. The absence of a detectable increase in total cancer deaths and lung cancer in particular associated with occupational exposures to polonium (mean lung dose 159.8 mSv), and to plutonium to a lesser extent (mean lung dose 13.7 mSv), is noteworthy but based on small numbers. Finally, larger combined studies of U.S. workers are needed to clarify radiation risks following prolonged exposures and radionuclide intakes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absorbed Gamma-Ray Doses due to Natural Radionuclides in Building Materials

This work is devoted to the application of high-resolution gamma-ray spectrometry in the study of the effective dose coming from naturally occurring radionuclides, namely {sup 40}K, {sup 232}Th and {sup 238}U, present in building materials such as sand, cement, and granitic gravel. Four models were applied to estimate the effective dose and the hazard indices. The maximum estimated effective dose coming from the three reference rooms considered is 0.90(45) mSv/yr, and maximum internal hazard index is 0.77(24), both for the compact clay brick reference room. The principal gamma radiation sources are cement, sand and bricks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Full-spectrum multiwavelength pyrometry for nongray surfaces

A full-spectrum (encompassing radiation on both sides of the Wien displacement peak) multiwavelength pyrometer was developed. It measures the surface temperature of arbitrary nongray ceramics by curve fitting a spectrum in this spectral region to a Planck function of temperature T. This function of T is modified by the surface spectral emissivity. The emissivity function was derived experimentally from additional spectra that were obtained by using an auxiliary radiation source and from application of Kirchhoff's law. This emissivity was verified by results that were obtained independently by using electromagnetic and solid-state theories. In the presence of interfering reflected radiation this general pyrometry improves the accuracy of the measured temperature by measuring an additional spectrum that characterizes the interfering radiation source.

Ng, Daniel↗