Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Radiation Tolerance of Nanopore Sequencing Technology for Life Detection on Mars and Europa

The search for life beyond Earth is a key motivator in space exploration. Informational polymers, like DNA and RNA, are key biosignatures for life as we know it. The MinION is a miniature DNA sequencer based on versatile nanopore technology that could be implemented on future planetary missions. A critical unanswered question is whether the MinION and its protein-based nanopores can withstand increased radiation exposure outside Earth’s shielding magnetic field. We evaluated the effects of ionizing radiation on the MinION platform – including flow cells, reagents, and hardware – and discovered limited performance loss when exposed to ionizing doses comparable to a mission to Mars. Targets with harsher radiation environments, like Europa, would require improved radiation resistance via additional shielding or design refinements.

Mark A. Sutton↗

Clusters of DNA damage induced by ionizing radiation: formation of short DNA fragments. II. Experimental detection

The basic 30-nm chromatin fiber in the mammalian cell consists of an unknown (possibly helical) arrangement of nucleosomes, with about 1.2 kb of DNA per 10-nm length of fiber. Track-structure considerations suggest that interactions of single delta rays or high-LET particles with the chromatin fiber might result in the formation of multiple lesions spread over a few kilobases of DNA (see the accompanying paper: W.R. Holley and A. Chatterjee, Radiat. Res. 145, 188-199, 1996). In particular, multiple DNA double-strand breaks and single-strand breaks may form. To test this experimentally, primary human fibroblasts were labeled with [3H]thymidine and exposed at 0 degrees C to X rays or accelerated nitrogen or iron ions in the LET range of 97-440 keV/microns. DNA was isolated inside agarose plugs and subjected to agarose gel electrophoresis under conditions that allowed good separation of 0.1-2 kb size DNA. The bulk of DNA remained in the well or migrated only a small distance into the gel. It was found that DNA fragments in the expected size range were formed linearly with dose with an efficiency that increased with LET. A comparison of the yield of such fragments with the yield of total DNA double-strand breaks suggests that for the high-LET ions a substantial proportion (20-90%) of DNA double-strand breaks are accompanied within 0.1-2 kb by at least one additional DNA double-strand break. It is shown that these results are in good agreement with theoretical calculations based on treating the 30-nm chromatin fiber as the target for ionizing particles. Theoretical considerations also predict that the clusters will contain numerous single-strand breaks and base damages. It is proposed that such clusters be designated "regionally multiply damaged sites." Postirradiation incubation at 37 degrees C resulted in a decline in the number of short DNA fragments, suggesting a repair activity. The biological significance of regionally multiply damaged sites is presently unknown.

Non-NASA Center↗

Pyroelectric detector development for the Radiation Measurement system

A new class of high detectivity pyroelectric detectors developed for optimization of the radiation measurement system within the framework of the Atmospheric Radiation Measurement program is described. These devices are intended to provide detectivities of up to about 10 exp 11 cm Hz exp 0.5/W with cooling to about 100 K required for the detector focal plane.

Hubbard, G. S.↗

The early bolometric evolution of Nova Cygni 1992

We report on combined ultraviolet and optical observations of early stages of the outburst of Nova Cygni 1992. We show that the initial optical rise and decline were produced by the dramatic increase in UV line opacity and its gradual subsequent lifting as the ejecta expand. The source of the M(sub v) - t(sub 3) relation is easily understood in light of these low-resolution UV spectra. The multiwavelength data confirm the theoretical prediction that a nova evolves at a constant bolometric luminosity in the early stages of outburst. We verify the prediction for this nova for at least the first month of the outburst. The detection of far-UV radiation with the Voyager Ultraviolet Spectrometer and the detection of an increasing X-ray flux with Roentgen Satellite (ROSAT) imply that this phase lasted for more than 6 months.

Shore, Steven N.↗

Investigating the Effects of Gamma Radiation on Selected Chemicals for Use in Biosignature Detection Instruments on the Surface of Jupiter's Moon Europa

Jupiter's moon Europa is a prime target for the search for potential signs of life in the solar system. The Europa Lander Science Definition Team Report outlined investigations and measurement requirements on a future Europa Lander and has led us to consider application of powerful techniques such as pyrolysis and derivatization gas chromatography mass spectrometry (GC-MS) and laser desorption mass spectrometry (LD-MS) to elucidate the organic composition of near-surface ice and minerals. Definitive identification of chemical biosignatures using such techniques is strongly enabled by the use of various chemicals, such as perfluorotributylamine (PFTBA) for the MS calibration, α-cyano-hydroxycinnamic acid (CHCA) for matrix-assisted laser desorption and ionization (MALDI) and N,N-dimethylformamide dimethyl acetal (DMF-DMA), N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA) and tetramethylammonium hydroxide (TMAH) for wet chemistry GC-MS protocols. The jovian radiation environment is known to represent a uniquely challenging risk to mission performance and lifetime, principally due to high radiation levels. To assess the potential ionizing radiation damage to these important chemicals, we tested their effectiveness following gamma radiation exposure doses up to the anticipated Europa Lander rating requirement of 300 krad(Si). The chemicals were sealed in glass ampules under vacuum (<10 mTorr), to reduce trapped oxygen gas, as the oxidation by O2 may be enhanced in the presence of radiation. We report that all five chemicals exposed to total ionizing doses of 0, 150 and 300 krad(Si) maintained their full effectiveness, and no significant degradation was observed.

Radiation↗

The Impact of Aerosols Generated from Biomass Burning, Dust Storms, and Volcanoes Upon the Earth's Radiative Energy Budget

A new technique for detecting aerosols from biomass burning and dust is developed. The radiative forcing of aerosols is estimated over four major ecosystems in South America. A new smoke and fire detection scheme is developed for biomass burning aerosols over South America. Surface shortware irradiance calculations are developed in the presence of biomass burning aerosols during the SCAR-B experiment. This new approach utilizes ground based, aircraft, and satellite measurements.

Christopher, Sundar A.↗

Ablation article and method

An ablation article, such as a conical heat shield, having an ablating surface is provided with at least one discrete area of at least one seed material, such as aluminum. When subjected to ablation conditions, the seed material is ablated. Radiation emanating from the ablated seed material is detected to analyze ablation effects without disturbing the ablation surface. By providing different seed materials having different radiation characteristics, the ablating effects on various areas of the ablating surface can be analyzed under any prevailing ablation conditions. The ablating article can be provided with means for detecting the radiation characteristics of the ablated seed material to provide a self-contained analysis unit.

Erickson, W. D.↗

Use of information on the motion of spacecraft around the center of bodies in the undertaking of detecting sources of X-ray and gamma radiation

The problem of localizing sources of X-ray and gamma surges can be solved vis the installation of suitable monitors on several dispersed spacecraft. In this manner, determination of the coordinates of the source is possible only with the use of four spacecraft. In the case of the use of 3 or 2 spacecraft, it is necessary to use supplementary information. Data on the motion of a spacecraft around the center of a mass was used in the capacity of such information.

Eysmont, N. A.↗

Gaseous optical contamination of the spacecraft environment: A review

Interactions between the ambient atmosphere and orbiting spacecraft, sounding rockets, and suborbital vehicles, and with their effluents, give rise to optical (extreme UV to LWIR) foreground radiation which constitutes noise that raises the detection threshold for terrestrial and celestial radiations, as well as military targets. Researchers review the current information on the on-orbit optical contamination. Its source species are created in interaction processes that can be grouped into three categories: (1) Reactions in the gas phase between the ambient atmosphere and desorbates and exhaust; (2) Reactions catalyzed by exposed ram surfaces, which occur spontaneously even in the absence of active material releases from the vehicles; and (3) Erosive excitative reactions with exposed bulk (organic) materials, which have recently been identified in the laboratory though not as yet observed on spacecraft. Researchers also assess the effect of optical pumping by earthshine and sunlight of both reaction products and effluents.

Tran, N. H.↗

Vacuum gage system for radiation environment

Hot-cathode ionization gages used to measure high-vacuum pressures are subject to error when ionizing radiation is present. Because this radiation creates additional ions, a second ion gage is mounted near the pressure-measuring gage to detect and measure the radiation induced error.

Summers, R. L.↗

Photon bunching and the photon-noise-limited performance of infrared detectors

The photon-noise-limited performance of a radiation detector exposed to a thermal background of temperature T is analyzed by calculating the resulting specific detectivity. Both ideal photon detectors of arbitrary quantum efficiency eta and ideal thermal detectors of arbitrary emissivity eta are considered; and the effects of both shot noise and excess noise are taken into account. The relative contributions of these two sources depend on the quantum efficiency or emissivity of the system. For frequencies nu such that hnu/kT is much less than eta, excess noise can make an appreciable contribution to the total system noise. For the case of the detection of the narrow-band radiation, the specific detectivity is independent of eta in the limit hnu/kT is much less than eta.

Boyd, R. W.↗

Optical communication with two-photon coherent states. II - Photoemissive detection and structured receiver performance

In a previous paper (1978), the authors developed a method of analyzing the performance of two-photon coherent state (TCS) systems for free-space optical communications. General theorems permitting application of classical point process results to detection and estimation of signals in arbitrary quantum states were derived. The present paper examines the general problem of photoemissive detection statistics. On the basis of the photocounting theory of Kelley and Kleiner (1964) it is shown that for arbitrary pure state illumination, the resulting photocurrent is in general a self-exciting point process. The photocount statistics for first-order coherent fields reduce to those of a special class of Markov birth processes, which the authors term single-mode birth processes. These general results are applied to the structure of TCS radiation, and it is shown that the use of TCS radiation with direct or heterodyne detection results in minimal performance increments over comparable coherent-state systems. However, significant performance advantages are offered by use of TCS radiation with homodyne detection. The abstract quantum descriptions of homodyne and heterodyne detection are derived and a synthesis procedure for obtaining quantum measurements described by arbitrary TCS is given.

Shapiro, J. H.↗

Observation of a strong gamma-ray burst on the Spacelab 2 mission

The observation of MeV gamma radiation from a burst on August 5, 1985 is reported. The burst was dominated by a single peak about 2 s wide, with softer, lower-level emission lasting about 20 s anywhere in the burst in any energy range. In the energy range from about 560 keV to about 10 MeV, the burst peaked about 0.3 s before the peak at lower energies. Radiation in the 10-16 MeV energy range was detected about 3 s before the lower-energy radiation, with roughly the same pulse width. This radiation was not detected during the main part of the burst. The energy of this burst in the range above 1 MeV was a significant fraction of the total burst energy, confirming earlier SMM results. If the appearance of high-energy photons prior to those at low energies is a ubiquitous feature of bursts or a class of bursts, current theoretical models may require considerable revision.

Fishman, G. J.↗

Ultraviolet Radiation

The lunar surface has a complex plasma environment due to incoming solar wind flux and charged micron-sized dust particles and the presence of solar ultraviolet (UV) radiation. UV resonance fluorescence of solar radiation provides a sensitive detection of major elemental constituents, such as H, H2, O, C, N, and noble gases in the tenuous daytime lunar atmosphere. Photoemission due to the solar UV radiation is the dominating process in the charging environment, creating a photoelectron “sheath.” Such detections were observed by LADEE UV spectrometer and the Apollo 17 UV spectrometer.

Caitlin Ahrens↗

Multiwavelength pyrometer for gray and non-gray surfaces in the presence of interfering radiation

A method and apparatus for detecting the temperature of gray and non-gray bodies in the presence of interfering radiation are presented. A gray body has a constant emissivity less than 1 and a non-gray body has an emissivity which varies with wavelength. The emissivity and reflectivity of the surface is determined over a range of wavelengths. Spectra are also measured of the extraneous interference radiation source and the surface of the object to be measured in the presence of the extraneous interference radiation source. An auxiliary radiation source is used to determine the reflectivity of the surface and also the emissivity. The measured spectrum of the surfaces in the presence of the extraneous interference radiation source is set equal to the emissivity of the surface multiplied by a Planck function containing a temperature term T plus the surface reflectivity multiplied by the spectrum of the extraneous interference radiation source. The equation is then solved for T to determine the temperature of the surface.

Ng, Daniel L. P.↗

Infrared differential absorption for atmospheric pollutant detection

Progress made in the generation of tunable infrared radiation and its application to remote pollutant detection by the differential absorption method are summarized. It is recognized that future remote pollutant measurements depended critically on the availability of high energy tunable transmitters. Futhermore, due to eye safety requirements, the transmitted frequency must lie in the 1.4 micron to 13 micron infrared spectral range.

Byer, R. L.↗