Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Precursor and Neutral Loss Scans in an RF Scanning Linear Quadrupole Ion Trap

Methodology for performing precursor and neutral loss scans in an RF scanning linear quadrupole ion trap is described and compared to the unconventional ac frequency scan technique. In the RF scanning variant, precursor ions are mass selectively excited by a fixed frequency resonance excitation signal at low Mathieu q while the RF amplitude is ramped linearly to pass ions through the point of excitation such that the excited ion’s m/z varies linearly with time. Ironically, a nonlinear ac frequency scan is still required for ejection of the product ions since their frequencies vary nonlinearly with the linearly varying RF amplitude. In the case of the precursor scan, the ejection frequency must be scanned so that it is fixed on a product ion m/z throughout the RF scan, whereas in the neutral loss scan, it must be scanned to maintain a constant mass offset from the excited precursor ions. Both simultaneous and sequential permutation scans are possible; only the former are demonstrated here. The scans described are performed on a variety of samples using different ionization sources: protonated amphetamine ions generated by nanoelectrospray ionization (nESI), explosives ionized by low-temperature plasma (LTP), and chemical warfare agent simulants sampled from a surface and analyzed with swab touch spray (TS). We lastly conclude that the ac frequency scan variant of these MS/MS scans is preferred due to electronic simplicity. In an accompanying manuscript, we thus describe the implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 using constant RF voltage. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IonCCD™ for direct position-sensitive charged-particle detection: from electrons and keV ions to hyperthermal biomolecular ions

A novel charged-particle sensitive, pixel based detector array is described and its usage is demonstrated for a variety of applications, from detection of elemental particles (electrons) to hyper-thermal large biomolecular positive and negative ions including keV light atomic and molecular ions. The array detector is a modified light-sensitive charged coupled device (CCD). The IonCCDTM was engineered for direct charged particle detection by replacing the semi-conductor part of the CCD pixel by a conductor1. In contrast with the CCD, where the semi-conductive pixel is responsible for electron-hole pair formation upon photon bombardment, the IonCCD uses a capacitor coupled to the conductive electrode for direct charge integration. The detector can be operated from atmospheric pressure to high vacuum since no high voltages are needed. The IonCCD, presented in this work is an array of 2126 active pixels with 21 um pixel width and 3 um pixel gap. The detection area is 1.5x51mm2 where 1.5 mm and 51 mm are pixel and detector array length, respectively. The result is a one-dimensional position-sensitive detector with 24 um spatial resolution and 88 % pixel area ratio (PAR). In this work we demonstrate the capabilities and the performance of the detector. For the first time we show the direct detection of 250 eV electrons providing linearity response and detection efficiency of the IonCCD as function of electron beam current. Using positive ions from and electron impact source (E-I), we demonstrate that the detection efficiency of the IonCCD is virtually independent of particle energy [250 eV, 1250 eV], particle impact angle [45o, 90o] and particle flux. By combining the IonCCD with a double focusing sector field of Mattauch-Herzog geometry (M-H), we demonstrate fast acquisition of mass spectra in direct air sniffing mode. A first step towards fast in vivo breath analysis is presented. Detection of hyper-thermal biomolecular ions produced using an electrospray ionization source (ESI) is presented. The IonCCD was used as beam profiler to characterize the beam shape and intensity of 15 eV protonated and deprotonated biomolecular ions at the exit of an RF only collisional quadrupole. We present simultaneous detection of 140 eV doubly protonated biomolecular ions when the IonCCD is combined with the M-H analyzer. The latter, demonstrates the possibility of simultaneous separation and micro-array deposition of biological material using a miniature sector field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of discharge parameters via OES at the Linac4 H{sup −} ion source

Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T{sub e} ≈ 1.2 eV, n{sub e} ≈ 1 × 10{sup 19} m{sup −3}, and n{sub H}/n{sub H{sub 2}} ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESIGN AND PRELIMINARY TEST OF THE 1500 MHZ NSLS-II PASSIVE SUPERCONDUCTING RF CAVITY

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. Earlier work described the design alternatives and the geometry selected for a copper prototype. We subsequently have iterated the design to lower the R/Q of the cavity and to increase the diameter of the beam pipe ferrite HOM dampers to reduce the wakefield heating. A niobium cavity and full cryomodule including LN2 shield, magnetic shield and insulating vacuum vessel have been fabricated and installed. A passive SRF 3rd harmonic cavity consisting of two tightly coupled cells has been designed and fabricated for NSLS-II. Initial cold tests of this cavity are very promising. These tests have verified that the cavity frequency and mode separation between the 0 and {pi}-modes can be set at manufacture. Further, the frequency separation can be maintained over wide tuning ranges necessary for operation. Future work includes HOM damper and motorized tuner development.

3 GeV 3rd generation synchrotron↗

RF generation in the DARHT Axis-II beam dump

We have occasionally observed radio-frequency (RF) electromagnetic signals in the downstream transport (DST) of the second axis linear induction accelerator (LIA) at the dual-axis radiographic hydrodynamic testing (DARHT) facility. We have identified and eliminated some of the sources by eliminating the offending cavities. However, we still observe strong RF in the range 1 GHz t0 2 GHz occurring late in the ~2-μs pulse that can be excited or prevented by varying the downstream tune. The narrow frequency width (<0.5%) and near exponential growth at the dominant frequency is indicative of a beam-cavity interaction, and electro-magnetic simulations of cavity structure show a spectrum rich in resonances in the observed frequency range. However, the source of beam produced RF in the cavity resonance frequency range has not been identified, and it has been the subject of much speculation, ranging from beam-plasma or beam-ion instabilities to unstable cavity coupling.

43 PARTICLE ACCELERATORS↗

Direct measurement of the transition from edge to core power coupling in a light-ion helicon source

Here, we present time-resolved measurements of an edge-to-core power transition in a light-ion (deuterium) helicon discharge in the form of infra-red camera imaging of a thin stainless steel target plate on the Proto-Material Exposure eXperiment device. The time-resolved images measure the two-dimensional distribution of power deposition in the helicon discharge. The discharge displays a mode transition characterized by a significant increase in the on-axis electron density and core power coupling, suppression of edge power coupling, and the formation of a fast-wave radial eigenmode. Although the self-consistent mechanism that drives this transition is not yet understood, the edge-to-core power transition displays characteristics that are consistent with the discharge entering a slow-wave anti-resonant regime. RF magnetic field measurements made across the plasma column, together with the power deposition results, provide direct evidence to support the suppression of the slow-wave in favor of core plasma production by the fast-wave in a light-ion helicon source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An electrostatic autoresonant ion trap mass spectrometer

A new method for ion extraction from an anharmonic electrostatic trap is introduced. Anharmonicity is a common feature of electrostatic traps which can be used for small scale spatial confinement of ions, and this feature is also necessary for autoresonant ion extraction. With the aid of ion trajectory simulations, novel autoresonant trap mass spectrometers (ART-MSs) have been designed based on these very simple principles. A mass resolution {approx}60 is demonstrated for the prototypes discussed here. We report also on the pressure dependencies, and the (mV) rf field strength dependencies of the ART-MS sensitivity. Importantly the new MS designs do not require heavy magnets, tight manufacturing tolerances, introduction of buffer gases, high power rf sources, nor complicated electronics. The designs described here are very inexpensive to implement relative to other instruments, and can be easily miniaturized. Possible applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen vacancies in niobium pentoxide as a source of two-level system losses in superconducting niobium

Two-level systems (TLS) have long been a catch-all explanation for RF loss and quantum decoherence in superconducting devices. In our study, the first to directly link TLS losses to a specific physical mechanism, we demonstrate that oxygen vacancies in the naturally formed Nb₂O₅ on oxidized niobium are a major driver of such dissipation. We performed sequential in situ vacuum-baking treatments on niobium superconducting radio-frequency (SRF) cavities and used time-of-flight secondary ion mass spectrometry (TOF-SIMS) to reveal a nonmonotonic evolution in cavity quality factor (Q₀). This behavior correlates with the interplay of Nb₂O₅ vacancy generation and oxide-thickness dissolution. We localize this effect to the oxide itself and present the insignificant role of diffused interstitial oxygen in the underlying Nb by regrowing the oxide via wet oxidation, revealing a mitigation of aggravated TLS losses. We hypothesize that such vacancies in the pentoxide serve as magnetic impurities and are a source of TLS-driven rf loss. Although our measurements center on 3-D SRF cavities, the insights gained here have significant implications for mitigating decoherence in 2-D superconducting qubits.

Bafia, Daniel P. [Fermilab]↗

RF Arc Detection in ICRH RDL Antennas by Phase Measurement

A voltage breakdown in an Ion Cyclotron Resonance Heating (ICRH) system is usually detected as an abrupt change in the module of the reflection coefficient |{gamma}in| at the power source output. The same effect can be due to a large load variation. This study is carried out by constructing a electrical model for a Tore Supra ITER-like antenna (TS ILA), and to analyse how a voltage breakdown, localized in any part of the system, modifies several electrical parameters of the circuit (with respect to perfect match conditions), as detected at the location of the monitoring points. The phase difference between the reflections coefficients measured at the output of tuning network when an arc strikes in one of two Resonant double loop (RDL) sections of the ICRH TS ILA appears to be the most promising parameter to detect the arc and identify its position. It is also significantly insensitive to a load variation so an arc and edge localized modes (ELMs) can be distinguished.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir Probe and Mass Spectroscopic Measurements in Inductively Coupled CF4 Plasmas

Abstract Electron and ion energy distribution functions and other plasma parameters such as plasma potential (V(sub p)) , electron temperature (T(sub e)), and electron and ion number densities (n (sub e) and n(sub i)) in low pressure CF4 plasmas have been measured. The experiments were conducted in a GEC cell using an inductively coupled plasma (ICP) device powered by a 13.56 MHz radio-frequency (rf) power source. The measurements were made at 300 W of input rf power at 10, 30 and 50 mTorr gas pressures. Langmuir probe measurements suggest that n(sub e), n(sub i) and V(sub p) remain constant over 60% of the central electrode area, beyond which they decrease. Within the limits of experimental error (+/- 0.25 eV), T(sub e) remains nearly constant over the electrode area. T(sub e) and V(sub p) increase with a decrease in pressure. n(sub e) and n(sub i) are not affected as significantly as T(sub e) or V(sub p) by variation in the gas pressure. The electron energy distribution function (EEDF) measurements indicate a highly non-Maxwellian plasma. CF3+ is the most dominant ion product of the plasma, followed by CF2+ and CF+. The concentrations of CF2+ and CF+ are much larger than that is possible from direct electron impact ionization of the parent gas. The cross-section data suggest that the direct electron impact ionization of fragment neutrals and negative ion production by electron attachment may be responsible for increase of the minor ions.

Rao, M. V. V. S.↗

Electron beam charging and arc discharging of spacecraft insulating materials

Samples of Mylar and Teflon film were exposed to combinations of monoenergetic electron and lithium ion fluxes in various ratios. The samples' discharge rates and strengths were found to diminish as the ion proportion increased. Various types of capacitors were exposed in air to beta irradiation from a 100 mCie Strontium-90 radioisotope source located at distances ranging from 2 cm to 5 cm from the capacitors. In these preliminary experiments, no evidence of spontaneous electrical breakdown was noted, nor was any change in RF impedance detectable using the available instrumentation. A decrease in DC resistance was noted, apparently due to radiation-induced conductivity. A cylindrical glass vacuum chamber is being assembled. Its inside dimensions are 44 cm diameter by 100 cm length. All necessary associated components and instruments have been acquired, including electron and ion guns, Trek surface potential probe and turbo-molecular pump. A mass-spectrometer detector for leaks and evolved gases will be ordered shortly.

Balmain, K. G.↗

A Magnetized Injector for Electron Cooling Applications

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility uses the existing ion/proton facility and augments it with an electron accelerator. Jefferson Lab plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require that the ion beams be cooled in order to reach the lu- minosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunch beam cooling, while Jefferson Lab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions such as flat beam klystrons, and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high performance injectors for electron cooling is limited, the potential market for high frequency RF sources and compact X-ray systems is considerable. Thus, the design methodologies developed in this project have a wide range of applicability. In this Phase I project, Xelera Research LLC performed simulations and calculations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and techniques that can then be applied to specific machine designs or other applications requiring magnetized injectors. In Phase II, the design will be further optimized, and then built in collaboration with a national lab partner. Xelera Research has many years of experience with electron sources and all of the skills and tools necessary to successfully carry out this project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 30-GHz monolithic receive module

Key requirements for a 30 GHz GaAs monolithic receive module for spaceborne communication antenna feed array applications include an overall receive module noise figure of 5 dB, a 30 dB RF to IF gain with six levels of intermediate gain control, a five-bit phase shifter, and a maximum power consumption of 250 mW. The RF designs for each of the four submodules (low noise amplifier, some gain control, phase shifter, and RF to IF sub-module) are presented. Except for the phase shifter, high frequency, low noise FETs with sub-half micron gate lengths are employed in the submodules. For the gain control, a two stage dual gate FET amplifier is used. The phase shifter is of the passive switched line type and consists of 5-bits. It uses relatively large gate width FETs (with zero drain to source bias) as the switching elements. A 20 GHz local oscillator buffer amplifier, a FET compatible balanced mixer, and a 5-8 GHz IF amplifier constitute the RF/IF sub-module. Phase shifter fabrication using ion implantation and a self-aligned gate technique is described. Preliminary RF results obtained on such phase shifters are included.

Sokolov, V.↗

Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources

Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High yield neutron generators using the DD reaction

A product line of high yield neutron generators has been developed at Adelphi technology inc. The generators use the D-D fusion reaction and are driven by an ion beam supplied by a microwave ion source. Yields of up to 5 Multiplication-Sign 10{sup 9} n/s have been achieved, which are comparable to those obtained using the more efficient D-T reaction. The microwave-driven plasma uses the electron cyclotron resonance (ECR) to produce a high plasma density for high current and high atomic ion species. These generators have an actively pumped vacuum system that allows operation at reduced pressure in the target chamber, increasing the overall system reliability. Since no radioactive tritium is used, the generators can be easily serviced, and components can be easily replaced, providing essentially an unlimited lifetime. Fast neutron source size can be adjusted by selecting the aperture and target geometries according to customer specifications. Pulsed and continuous operation has been demonstrated. Minimum pulse lengths of 50 {mu}s have been achieved. Since the generators are easily serviceable, they offer a long lifetime neutron generator for laboratories and commercial systems requiring continuous operation. Several of the generators have been enclosed in radiation shielding/moderator structures designed for customer specifications. These generators have been proven to be useful for prompt gamma neutron activation analysis (PGNAA), neutron activation analysis (NAA) and fast neutron radiography. Thus these generators make excellent fast, epithermal and thermal neutron sources for laboratories and industrial applications that require neutrons with safe operation, small footprint, low cost and small regulatory burden.

43 PARTICLE ACCELERATORS↗

Ion funnel device

An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Construction of the BNL EBIS preinjector

A new heavy ion preinjector, consisting of an Electron Beam Ion Source (EBIS), an RFQ, and IH linac, is under construction at Brookhaven National Laboratory. This preinjector win provide ions of any species at an energy of 2 MeV/u, resulting in increased capabilities for the Relativistic Heavy Ion Collider, and the NASA Space Radiation Laboratory programs. The RF'Q has been commissioned with beam, and most of the remaining elements are either installed or being assembled.

43 PARTICLE ACCELERATORS↗

Ambipolar and non-ambipolar diffusion in an rf plasma source containing a magnetic filter

By placing a magnetic filter across a rectangular plasma source (closed at one end with a ceramic plate and an rf antenna, and terminated at the opposite end by a grounded grid), we experimentally investigate the effect of conducting and insulating source walls on the nature of the plasma diffusion phenomena. The use of a magnetic filter creates a unique plasma, characterized by a high upstream electron temperature (T{sub e{sub u}}∼5 eV) near the rf antenna and a low downstream electron temperature (T{sub e{sub d}}∼1 eV) near the grid, which more clearly demonstrates the role of the source wall materials. For conducting walls a net ion current to ground is measured on the grid, and the plasma potential is determined by a mean electron temperature within the source. For insulating walls the plasma potential is determined by the downstream electron temperature (i.e., V{sub p}∼5.2T{sub e{sub d}} in argon), and the net current to the grid is exactly zero. Furthermore, by inserting a small additional upstream conductor (that can be made floating or grounded through an external circuit switch), we demonstrate that the plasma potential can be controlled and set to a low (V{sub p}∼5.2T{sub e{sub d}}), or high (V{sub p}∼5.2T{sub e{sub u}}) value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗