A Dynamic Model of Refrigerator with Thermal Energy Storage for Demand Flexibility

A refrigerator is an essential appliance for both commercial and residential applications. Thermal (Cold) energy storage can effectively reduce the carbon emission from refrigerators. This preliminary study investigated the demand flexibility of a domestic refrigerator using thermal (cold) energy storage through dynamic modeling and controls. The models include both fresh and frozen compartments, a vapor compression cycle loop, and thermal storage panels. Results show that thermal energy storage can effectively achieve temperature control of the compartments within the 4-hour time window. The load reduction and cost savings (46.3%) were achieved through the TES using TOU rates.

Gao, Zhiming↗

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Next Generation Refrigerants for Domestic Heat Pump Water Heaters

To select next generation refrigerants and phase out R-134a, we conducted extensive drop-in tests of multiple new refrigerants. For laboratory investigations, we performed drop-in UEF (uniform energy factor) and FHR (first hour rating) tests on two heat pump water heaters (HPWHs), one uses a 220V compressor and 40-gallon water tank, and the other uses a 120V compressor and 50-gallon tank. The alternative refrigerants/blends include R-1234yf, R-1234ze, R-515B, R-513A, and R-516A, among which R-513A is A1, non-flammable and the others are in A2L category. All the alternative refrigerants required similar optimum system charges as the baseline R-134a. They resulted in similar or better UEFs than R-134a. R-516A led to best UEFs in both the HPWHs. The resultant discharge temperatures of the new refrigerants/blends are lower than R-134a, indicating good lubricant compatibility. The 120V HPWH delivered > 60 gallons first-hour rating using R-134a. The alternatives led to reduced FHRs due to their smaller volumetric vaporization capacities using the same compressor. Except R-515B, the other refrigerants/blends delivered FHRs > 60 gallons. R-516A produced better UEFs and FHRs in both the units than the other replacements. If considering flammability, R-513A would be the best option, which has similar UEF and FHR as R-134a.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Performance Validation of Refrigeration Recovery for Experimental Hall High Target Loads

The Qweak experiment at Jefferson Lab (JLab) is a 3000 W hydrogen target scheduled to run until the planned shutdown in the spring of 2012 for the 12 GeV installation. As detailed in previous proceedings, support of this target's cryogenic load was made possible by incorporating modifications to the End Station Refrigerator (ESR) to recover the refrigeration supplied by the Central Helium Liquefier (CHL). Testing and commissioning for these modifications was performed in January and February 2010 demonstrating that the performance met or exceeded projected expectations. In this paper, we present the analysis of the test results in regards to the actual loads capable of being supported and the process boundaries encountered, as well as a discussion of the commissioning results for the cryogenic support of the Qweak target.

08 HYDROGEN↗

High magnetic-refrigeration performance of plate-shaped La{sub 0.5}Pr{sub 0.5}Fe{sub 11.4}Si{sub 1.6} hydrides sintered in high-pressure H{sub 2} atmosphere

La(Fe, Si){sub 13} hydride is regarded as one of the most promising room-temperature refrigerants. However, to use the alloys in an active magnetic regenerator machine, it is vital to prepare thin refrigerants. In this work, a high H{sub 2} gas pressure of 50 MPa was employed to suppress the desorption of hydrogen atoms during the sintering process of plate-shaped La{sub 0.5}Pr{sub 0.5}Fe{sub 11.4}Si{sub 1.6} hydrides. At 330 K, a high-density sintered thin plate shows a large magnetic-entropy change ΔS{sub m} of 15.5 J/kg K (106 mJ/cm{sup 3 }K) for a field change of 2 T. The volumetric ΔS{sub m} is almost twice as large as that of bonded La(Fe,Si){sub 13} hydrides. Favorably, hysteresis is almost absent due to the existence of micropores with a porosity of 0.69% which has been analyzed with high-resolution X-ray microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning the heat transfer medium and operating conditions in magnetic refrigeration

A new experimental test bed has been designed, built, and tested to evaluate the effect of the system’s parameters on a reciprocating Active Magnetic Regenerator (AMR) near room temperature. Bulk gadolinium was used as the refrigerant, silicon oil as the heat transfer medium, and a magnetic field of 1.3 T was cycled. This study focuses on the methodology of single stage AMR operation conditions to get a high temperature span near room temperature. Herein, the main objective is not to report the absolute maximum attainable temperature span seen in an AMR system, but rather to find the system’s optimal operating conditions to reach that maximum span. The results of this research show that there is a optimal operating frequency, heat transfer fluid flow rate, flow duration, and displaced volume ratio in any AMR system. By optimizing these parameters in our AMR apparatus the temperature span between the hot and cold ends increased by 24%. The optimized values are system dependent and need to be determined and measured for any AMR system by following the procedures that are introduced in this research. It is expected that such optimization will permit the design of a more efficient magnetic refrigeration system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Flight-Worthy 10 to 4 K Continuous Adiabatic Demagnetization Refrigerator

The cryogenics and fluids branch at NASA's Goddard Space Flight Center is currently developing a high-efficiency, vibration-free, flight-worthy Continuous Adiabatic Demagnetization Refrigerator (CADR) that consist of two modular units: one that lifts ~6 microW at 50 mK while rejecting its heat to a 4 K thermal sink, and another unit that provides a constant 4 K cooling stage while rejecting its heat to a thermal sink at 10 K. The two units are linked together via a 4 K common platform. This paper discusses the status report on the thermodynamic performance of the 4 -10 K ADR. This ADR utilizes an Nb3Sn superconducting magnet and Gadolinium Gallium Garnet (GGG) as its refrigerant. Results show that an idealized cycle, one where its hold time at 4 K is equal to the recycle time, can lift 13 mW at 4 K with a hold time of 132 seconds.

CADR↗

Review of Vapor Compression Refrigeration in Microgravity Environments

Using a vapor compression cycle for cooling in microgravity environments was already suggested in the 1970s to leverage the high coefficient of performance. Since then, only a few systems have operated in microgravity with scarce documentation of these flights. The lack of measured data and detailed documentation makes identifying the necessary next steps difficult for researchers entering the field of refrigeration in space. This paper provides a review of available literature for vapor compression systems flown in microgravity by outlining the history of vapor compression devices in space and presenting performance data. Moreover, gaps in the literature are highlighted and open questions are posed based on the reviewed material. Next steps of research are suggested to support and ultimately achieve reliable vapor compression refrigeration in space. Calculating equivalent masses for a fair comparison of different microgravity cooling technologies is proposed by capturing both energy consumption and used volume.

Vapor compression↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation

As one of the latest emerging HVAC technologies, the Variable Refrigerant Flow (VRF) system with heat recovery (HR) configurations has obtained extensive attention from both the academia and industry. Compared with the conventional VRF systems with heat pump (HP) configurations, VRF-HR is capable of recovering heat from cooling zones to heating zones and providing simultaneous cooling and heating operations. Moreover, this could lead to substantial energy saving potential and more flexible zonal control. In this paper, a novel model is developed to simulate the energy performance of VRF-HR systems. It adheres to a more physics-based development with the ability to simulate the refrigerant loop performance and consider the dynamics of more operational parameters, which is crucial for representing more advanced control logics. Another key feature of the model is the introduction of component-level curves for indoor units and outdoor units instead of overall performance curves for the entire system, and thus it requires much fewer user-specified performance curves as model inputs. The validation study reflects good agreements between the simulated energy use from the new VRF-HR model and the laboratory measurement data across all operational modes at sub-hourly time steps. The model has been adopted in the official release of the EnergyPlus simulation program since Version 8.6, which enables more accurate and robust assessments of VRF-HR systems to support their applications in energy retrofit of existing buildings or design of zero-net-energy buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants

Based on laboratory investigations for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), the DOE/ORNL Heat Pump Design Model was used to model the two RTUs and the models were calibrated against the experimental data. We compared the compressor efficiencies and heat exchanger performances. An efficiency-based compressor mapping method was developed. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting optimal configurations. The results illustrate that all the R-22 low GWP refrigerants will lead to slightly lower COPs. ARM-20B appears to be the best R-22 replacement at normal conditions. At higher ambient temperatures, ARM-20A exhibits better performance. All R-410A low GWP candidates will result in similar or better efficiencies than R-410A. R-32 has the best COP while requiring the smallest compressor. Finally, R-452B uses the closest compressor displacement volume and achieves the same efficiency as R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrothermal stability of SAPO-34 for refrigeration and air conditioning applications

Graphical abstract: The SAPO-34 was synthesized by a hydrothermal method using diethylamine as a template. Water adsorption strength on SAPO-34 is between that on 13X and A type silica gel. During 100–400 Pa, the water uptake on SAPO-34 increases sensitively to pressure, and equilibrium water uptake reaches 0.35 kg/kg, 25% higher than 13X. SAPO-34 shows no significant reduced cyclic water uptake over 60 cycles. Most of the initial SAPO-34 phase is restored, while the regular cubic-like morphology is well maintained, and the specific surface area only decreases by 8.6%. - Highlights: • Water adsorption strength on SAPO-34 is between that on 13X and A type silica gel. During 100–400 Pa, the water uptake on SAPO-34 increases sensitively to pressure, and equilibrium water uptake reaches 0.35 kg/kg, 25% higher than 13X. • SAPO-34 with diethylamine as the template shows no significant reduced cyclic water uptake over 60 cycles, and most of the initial SAPO-34 phase is well maintained. • SAPO-34 has an excellent adsorption performance and a good hydrothermal stability, thus is promising for application in adsorption refrigeration. - Abstract: Hydrothermal stability is one of the crucial factors in applying SAPO-34 molecular sieve to adsorption refrigration. The SAPO-34 was synthesized by a hydrothermal method using diethylamine as a template. Both a vacuum gravimetric method and an intelligent gravimetric analyzer were applied to analyze the water adsorption performance of SAPO-34. Cyclic hydrothermal performance was determined on the modified simulation adsorption refrigeration test rig. Crystal phase, morphology, and porosity of SAPO-34 were characterized by X-ray diffraction, scanning electron microscopy, and N{sub 2} sorption, respectively. The results show that, water adsorption strength on SAPO-34 is between that on 13X and A type silica gel. During 100–400 Pa, the water uptake on SAPO-34 increases sensitively to pressure, and equilibrium water uptake reaches 0.35 kg/kg, 25% higher than 13X. SAPO-34 shows no significant reduced cyclic water uptake over 60 cycles. Most of the initial SAPO-34 phase is restored, while the regular cubic-like morphology is well maintained, and the specific surface area only decreases by 8.6%.

36 MATERIALS SCIENCE↗

Cryogenics for superconductors: Refrigeration, delivery, and preservation of the cold

Applications in superconductivity have become widespread, enabled by advancements in cryogenic engineering. In this paper, the history of cryogenic refrigeration, its delivery, its preservation and the important scientific and engineering advancements in these areas in the last 100 years will be reviewed, beginning with small laboratory dewars to very large scale systems. The key technological advancements in these areas that enabled the development of superconducting applications at temperatures from 4 to 77 K are identified. Included are advancements in the components used up to the present state-of-the-art in refrigeration systems design. Viewpoints as both an equipment supplier and the end-user with regard to the equipment design and operations will be presented. Some of the present and future challenges in these areas will be outlined. Most of the materials in this paper are a collection of the historical materials applicable to these areas of interest.

36 MATERIALS SCIENCE↗