Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRACTIVE INDEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Dust Optical Properties Over North Africa and Arabian Peninsula Derived from the AERONET Dataset

Dust optical properties over North Africa and the Arabian Peninsula are extracted from the quality assured multi-year datasets obtained at 14 sites of the Aerosol Robotic Network (AERONET). We select the data with (a) large aerosol optical depth (AOD >= 0.4 at 440 nm) and (b) small Angstrom exponent (A(sub ext)<= 0.2) for retaining high accuracy and reducing interference of non-dust aerosols. The result indicates that the major fraction of high aerosol optical depth days are dominated by dust over these sites even though it varies depending on location and time. We have found that the annual mean and standard deviation of single scattering albedo, asymmetry parameter, real refractive index, and imaginary refractive index for Saharan and Arabian desert dust is 0.944 +/- 0.005, 0.752 +/- 0.014, 1.498 +/- 0.032, and 0.0024 +/- 0.0034 at 550 nm wavelength, respectively. Dust aerosol selected by this method is less absorbing than the previously reported values over these sites. The weaker absorption of dust from this study is consistent with the studies using remote sensing techniques from satellite. These results can help to constrain uncertainties in estimating global dust shortwave radiative forcing.

Kim, D.↗

Nanolaser spectroscopy and micro-optical resonators for detecting, analyzing, and manipulating bioparticles

This invention provides a new method for rapidly analyzing single bioparticles to assess their material condition and state of health. The method is enabled by use of a resonant cavity apparatus to measure an optical property related to the bioparticle size and refractive index. Measuring the refractive index is useful for determining material properties of the bioparticle. The material properties depend on the biomolecular composition of the bioparticle. The biomolecular composition is, in turn, dependent on the state of health of the bioparticle. Thus, measured optical properties can be used to differentiate normal (healthy) and abnormal (diseased) states of bioparticles derived from cells or tissues. The method is illustrated with data obtained from a resonator with a gain medium. The invention also provides new methods for making multiple measurements in a single device and detecting, analyzing, and manipulating bioparticles that are much smaller than the wavelength of light.

47 OTHER INSTRUMENTATION↗

Laser diode package with enhanced cooling

This invention provides a new method for rapidly analyzing single bioparticles to assess their material condition and state of health. The method is enabled by use of a resonant cavity apparatus to measure an optical property related to the bioparticle size and refractive index. Measuring the refractive index is useful for determining material properties of the bioparticle. The material properties depend on the biomolecular composition of the bioparticle. The biomolecular composition is, in turn, dependent on the state of health of the bioparticle. Thus, measured optical properties can be used to differentiate normal (healthy) and abnormal (diseased) states of bioparticles derived from cells or tissues. The method is illustrated with data obtained from a resonator with a gain medium. The invention also provides new methods for making multiple measurements in a single device and detecting, analyzing, and manipulating bioparticles that are much smaller than the wavelength of light.

47 OTHER INSTRUMENTATION↗

TPSAS-NF1676L-22701-DND

The next generation of aerosol satellite instruments will include multi-spectral polarimetric measurements to retrieval aerosol size distribution and refractive index (Hasekamp et al., 2011; NRC, 2007). Refractive index is the “only means of constraining aerosol chemical composition from space” for passive sensors (Mischenko et al., 2007). A number of methods have been developed to derive refractive index from combined optical and electrical mobility sizing instruments (e.g., the “Alignment Method” of Hand and Kreidenweis, 2002). In this work, we evaluate the sensitivity of two, commercially-available, high-resolution optical particle counters for determining the size-resolved refractive index of laboratory-generated aerosols when used with a modified form of the Alignment Method.

Stephen Zimmerman↗

Goos-Hänchen effect and bending of spin wave beams in thin magnetic films

For magnon spintronic applications, the detailed knowledge of spin wave (SW) beam dispersion, transmission (reflection) of SWs passing through (reflected from) interfaces, or borders or the scattering of SWs by inhomogeneities is crucial. These wave properties are decisive factors on the usefulness of a particular device. Here, we demonstrate, using micromagnetic simulations supported by an analytical model, that the Goos-Hänchen (GH) shift exists for SW reflecting from thin film edge and that with the effect becomes observable. We show that this effect will exist for a broad range of frequencies in the dipole-exchange range, with the magnetization degree of pinning at the film edge as the crucial parameter, whatever its nature. Moreover, we have also found that the GH effect can be accompanied or even dominating by a bending of the SW beam due to the inhomogeneity of the internal magnetic field. This inhomogeneity, created by demagnetizing field taking place at the film edge, causes gradual change of SWs refractive index. The refraction of the SW beams by the non-uniformity of the magnetic field enables the exploration of graded index magnonics and metamaterial properties for the transmission and processing of information at nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metamaterial near-field sensor for deep-subwavelength thickness measurements and sensitive refractometry in the terahertz frequency range

We present a metamaterial-based terahertz (THz) sensor for thickness measurements of subwavelength-thin materials and refractometry of liquids and liquid mixtures. The sensor operates in reflection geometry and exploits the frequency shift of a sharp Fano resonance minimum in the presence of dielectric materials. We obtained a minimum thickness resolution of 12.5 nm (1/16 000 times the wavelength of the THz radiation) and a refractive index sensitivity of 0.43 THz per refractive index unit. We support the experimental results by an analytical model that describes the dependence of the resonance frequency on the sample material thickness and the refractive index.

36 MATERIALS SCIENCE↗

Resonant Transmissive Modulator Construction for Use in Beam Steering Array

An agile electronically configurable optical beam steering device for use in directional free-space transmission of optical signals is described. The device design employs an array of tunable resonant transmissive modulators constructed from multi-layered stacks of electro-optically active dielectric materials. Each modulator may be individually configured to transmit an optical signal with a specific amount of phase and group velocity modulation. The resulting diffractive interactions between modulator outputs provide a method for directional optical signal transmission. Of particular focus within this presentation is the optimized design of the individual modulator. It is widely known that periodic multi-layered stacks of dielectric materials exhibit reflective and transmissive resonances as described by the stack's transmission function. If an electric field is applied normal to the stack's layers, phenomena such as the electro-optic effect and/or the quantum-confined Stark effect may be employed to change the effective refractive index within the stack. This refractive index change alters the stack's transmission function and modulates the phase and group velocity of the transmitted optical signal. By varying the parameters that describe the stack's specific construction and operation, such as number of layers within the stack, refractive indexes of stack materials, layer thicknesses, and combinations of periodic verses non-periodic layer repetitions, custom transmittance functions may be generated. The transmitted optical signal carrier frequency and bandwidth must be carefully selected to maximize transmission and to minimize absorption. A computational optimization of the variables describing the stack's construction strives to maximize the amount of optical signal modulation verses applied voltage. Trade-offs between methods of increasing device performance verses the limitations of fabrication technologies are considered.

Keys, Andrew S.↗

X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n= 1 -{delta}+i {beta}. The real part of the refractive index, specifically the refractive index decrement ({delta}), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine {delta}. At each x-ray photon energy, the absolute percent difference in {delta} between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient {mu}, and hence {beta}, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the {delta} of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the {mu} of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the {delta} of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of {mu}. Polymethyl methacrylate, a commonly used tissue substitute, exhibited {delta} greater than fibroglandular tissue by {approx}12%. The A-150 plastic closely approximated the skin. Several materials exhibited {delta} between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between {delta} and {mu} for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the {delta} and {mu} of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited {delta} greater than calcium hydroxyapatite by {approx}23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-fiber plasmonic interferometer for multi-parameter sensing

We demonstrate a novel miniature multi-parameter sensing device based on a plasmonic interferometer fabricated on a fiber facet in the optical communication wavelength range. This device enables the coupling between surface plasmon resonance and plasmonic interference in the structure, which are the two essential mechanisms for multi-parameter sensing. We experimentally show that these two mechanisms have distinctive responses to temperature and refractive index, rendering the device the capability of simultaneous temperature and refractive index measurement on an ultra-miniature form factor. A high refractive index sensitivity of 220 nm per refractive index unit (RIU) and a high temperature sensitivity of –60 pm/ °C is achieved with our device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anisotropic index of refraction and structural properties of hexagonal boron nitride epilayers probed by spectroscopic ellipsometry

The anisotropic index of refraction of 200 μm thick boron-10 enriched hexagonal boron nitride (h-BN) freestanding epilayers grown by metalorganic chemical vapor deposition has been measured using spectroscopic ellipsometry in the UV (4.0–5.1 eV) spectral range. It was found that the index of refraction for the polarization mode with an electric field perpendicular to the c-axis (ordinary, n o ) is much higher than that with an electric field parallel to the c-axis (extraordinary, n e ). By inclusion of turbostratic- (t-) phase layers within h-BN having an average inclination angle (θ) with respect to the ideal c-plane, a simple method for quantifying θ has been deduced. Our results revealed that the presence of t-phase layers decreases the optical anisotropy of h-BN and that a signature of improved crystalline quality is an increase in the ordinary index of refraction (n o ) as a result of the average incline angle θ approaching 0° and predicted that n o = 2.7 and n e = 1.5 at 280 nm for single crystalline h-BN epilayers. More importantly, our results demonstrated that spectroscopic ellipsometry is an effective technique for characterizing the crystalline quality of h-BN epilayers with the advantages of being noninvasive and highly sensitive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Index of Refraction on Radiation Characteristics in a Heated Absorbing, Emitting, and Scattering Layer

The effect of the index of refraction on the temperature distribution and radiative heat flux in semitransparent materials, such as some ceramics, is investigated analytically. In the case considered here, a plane layer of a ceramic material is subjected to external radiative heating incident on each of its surfaces; the material emits, absorbs, and isotropically scatters radiation. It is shown that, for radiative equilibrium in a gray layer with diffuse interfaces, the temperature distribution and radiative heat flux for any index of refraction can be obtained in a simple manner from the results for an index of refraction of unity.

Siegel, R.↗

Exciton effects in the index of refraction of multiple quantum wells and superlattices

Theoretical calculations of the index of refraction of multiple quantum wells and superlattices are presented. The model incorporates both the bound and continuum exciton contributions for the gamma region transitions. In addition, the electronic band structure model has both superlattice and bulk alloy properties. The results indicate that large light-hole masses, i.e., of about 0.23, produced by band mixing effects, are required to account for the experimental data. Furthermore, it is shown that superlattice effects rapidly decrease for energies greater than the confining potential barriers. Overall, the theoretical results are in very good agreement with the experimental data and show the importance of including exciton effects in the index of refraction.

Kahen, K. B.↗

Wave-Based Subsurface Guide Star

Astronomical or optical guide stars are either natural or artificial point sources located above the Earth's atmosphere. When imaged from ground-based telescopes, they are distorted by atmospheric effects. Knowing the guide star is a point source, the atmospheric distortions may be estimated and, deconvolved or mitigated in subsequent imagery. Extending the guide star concept to wave-based measurement systems to include acoustic, seismo-acoustic, ultrasonic, and radar, a strong artificial scatterer (either acoustic or electromagnetic) may be buried or inserted, or a pre-existing or natural sub-surface point scatterer may be identified, imaged, and used as a guide star to determine properties of the sub-surface volume. That is, a data collection is performed on the guide star and the sub-surface environment reconstructed or imaged using an optimizer assuming the guide star is a point scatterer. The optimization parameters are the transceiver height and bulk sub-surface background refractive index. Once identified, the refractive index may be used in subsequent reconstructions of sub-surface measurements. The wave-base guide star description presented in this document is for a multimonostatic ground penetrating radar (GPR) but is applicable to acoustic, seismo-acoustic, and ultrasonic measurement systems operating in multimonostatic, multistatic, multibistatic, etc., modes.

42 ENGINEERING↗

Eigenfrequencies and eigenmodes of a ring optical resonator with thin dielectric plates

A ring optical resonator containing arbitrarily placed dielectric plates is considered. The resonator inhomogeneity introduced by the plates is insignificant: the thickness of plates and the excess of their refractive index over the average refractive index of the resonator obey the condition of smallness. It is shown that the eigenfrequency spectrum of this resonator is simple and represents an equidistant sequence of weakly split frequency doublets. Splitting in each doublet is found. Modes in the form of perturbed standing waves are quantitatively described. The formalism of the shift matrices along the trajectories of the differential equation, which makes it possible to obtain the result in the simplest way, is used to solve the above spectral problem. (resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vacuum energy and the spacetime index of refraction: A new synthesis

In 1+3 (threading) formulation of general relativity spacetime behaves analogous to a medium with a specific index of refraction with respect to the light propagation. Accepting the reality of zero-point energy, through the equivalence principle, we elevate this analogy to the case of virtual photon propagation in a quantum vacuum in a curved background spacetime. Employing this new idea (conjecture) one could examine the response of vacuum energy to the presence of a weak stationary gravitational field in its different quantum field theoretic manifestations such as Casimir effect and Lamb shift. As an evidence in favor of the proposed conjecture, employing quantum field theory in curved spacetime, we explicitly calculate the effect of a weak static gravitational field on virtual massless scalar particles in a Casimir apparatus. It is shown that, as expected from the proposed conjecture, both the frequency and renormalized energy of the virtual scalar field are affected by the gravitational field through its index of refraction. Generalizations to weak stationary spacetimes and virtual photons are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methodology to Account for Radiation and Temperature Influences on Optical Fibers compaction and Index of Refraction

The effects of radiation induced compaction and index of refraction change can cause significant drift in the measurements from intrinsic fiber optic temperature sensors. The work presented here aims to develop and test a methodology to measure these macroscopic properties that are responsible for the drift in order to correct the measurement. This report discusses the measurement methodology, theory, and sensor construction. Preliminary results from the first irradiation test using this sensor are provided here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter constraints from a cosmic index of refraction

The dark matter candidates of particle physics invariably possess electromagnetic interactions, if only via quantum fluctuations. Taken en masse, dark matter can thus engender an index of refraction which deviates from its vacuum value. Its presence is signaled through frequency-dependent effects in the propagation and attenuation of light. We discuss theoretical constraints on the expansion of the index of refraction with frequency, the physical interpretation of the terms, and the particular observations needed to isolate its coefficients. This, with the advent of new opportunities to view gamma-ray bursts at cosmological distance scales, gives us a new probe of dark matter and a new possibility for its direct detection. As a first application we use the time delay determined from radio afterglow observations of distant gamma-ray bursts to realize a direct limit on the electric charge-to-mass ratio of dark matter of |{epsilon}|/M<1x10{sup -5} eV{sup -1} at 95% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗