Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Preliminary Neutronics Design and Analysis of the Fast Modular Reactor

General Atomics is developing a new 100-MW(thermal) fast modular reactor (FMR) that provides safe, carbon-free electricity and is capable of incremental capacity additions. The modular design allows it to be factory built and assembled onsite to keep the capital cost low, while the use of dry cooling facilitates siting to complement renewables in nearly any location. The FMR uses high-assay low-enriched uranium-dioxide fuel encapsulated by recognized irradiationresistant silicon carbide composite (SiGA®) cladding that is derisked in the current accident-tolerant fuel program. The FMR fuel assembly is a hexagonal fuel bundle of 120 fuel rods. The total length of the fuel assembly is less than 4 m, with an active fuel length of 1.8 m. The fuel assemblies are configured in an annular core that is located and supported by the reactor internals. The coolant material is helium at a normal operating pressure of 7 MPa. The core is surrounded by zirconium silicide (Zr 3 Si 2 ) and graphite reflector blocks. The fuel, coolant, internals, and reflectors are contained within a reactor pressure vessel. Here, the preliminary nuclear design and analysis established the arrangement of the active core and reflector blocks. The nuclear design analyses of the FMR defined the design parameters, such as fuel enrichments, excess reactivity, fueling scheme, fuel cycle, power distribution, and control rod worth. The preliminary conceptual design determined the three-batch fueling scheme with the allowable total power peaking factor of 1.5. The average discharge burnup is 100 GW days per ton of uranium.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulating Scintillator Light Collection Using Measured Optical Reflectance

To accurately predict the light collection from a scintillating crystal through Monte Carlo simulations, it is crucial to know the angular distribution from the surface reflectance. Current Monte Carlo codes allow the user to set the optical reflectance to a linear combination of backscatter spike, specular spike, specular lobe, and Lambertian reflections. However, not all light distributions can be expressed in this way. In addition, the user seldom has the detailed knowledge about the surfaces that is required for accurate modeling. We have previously measured the angular distributions within BGO crystals and now incorporate these data as look-up-tables (LUTs) into modified Geant4 and GATE Monte Carlo codes. The modified codes allow the user to specify the surface treatment (ground, etched, or polished), the attached reflector (Lumirror(R), Teflon(R), ESR film, Tyvek(R), or TiO paint), and the bonding type (air-coupled or glued). Each LUT consists of measured angular distributions with 4o by 5o resolution in theta and phi, respectively, for incidence angles from 0? to 90? degrees, in 1o-steps. We compared the new codes to the original codes by running simulations with a 3 x 10 x 30 mm3 BGO crystal coupled to a PMT. The simulations were then compared to measurements. Light output was measured by counting the photons detected by the PMT with the 3 x 10, 3 x 30, or 10 x 30 mm2 side coupled to the PMT, respectively. Our new code shows better agreement with the measured data than the current Geant4 code. The new code can also simulate reflector materials that are not pure specular or Lambertian reflectors, as was previously required. Our code is also more user friendly, as no detailed knowledge about the surfaces or light distributions is required from the user.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the first mechanically-coupled twisting heliostat: encircled energy vs angle of incidence, and closed loop tracking

The first automatic twisting heliostat, with 8 m2 reflector, was completed and tested on-sun in January 2024. It was set up on a target-oriented dual-axis mount, with the target-axis aimed at a target 113 m to the west. The shape-twisting is purely automatic, made by a mechanical cam coupling to the cross-axis, which turns as the angle of incidence of the sun’s rays on the reflector. Three unsaturated images taken at different times of day were recorded of the sun on the target, reflected at angles of incidence of 5°, 49° and 68°. The measured FWHM of three images is very similar, about 1.09 m or 9.5 mrad, only slightly larger than an ideal solar disc, indicating that the different twisted reflector shapes are close to the ideal biconics needed to image the sun. The encircled energy measured for all three images was similar, 87% within approximately 1.30 m diameter. We report here also on a novel, tracking camera that employs a semitransparent beamsplitter fixed perpendicular to the mirror surface and to the plane of incidence. Over 2.5 hours of measurement of closed loop tracking, errors were ≤ 0.36 mrad rms, in both tracking axes.

14 SOLAR ENERGY↗

SU-F-T-183: Design of a Beam Shaping Assembly of a Compact DD-Based Boron Neutron Capture Therapy System

Purpose: To design a beam shaping assembly (BSA) to shape the 2.45-MeV neutrons produced by a deuterium-deuterium (DD) neutron generator and to optimize the beam output for boron neutron capture therapy of brain tumors Methods: MCNP is used for this simulation study. The simulation model consists of a neutron surface source that resembles an actual DD source and is surrounded by a BSA. The neutron source emits 2.45-MeV neutrons isotropically. The BSA is composed of a moderator, reflector, collimator and filter. Various types of materials and geometries are tested for each component to optimize the neutron output. Neutron characteristics are measured with an 2×2×2-cm{sup 3} air-equivalent cylinder at the beam exit. The ideal BSA is determined by evaluating the in-air parameters, which include epithermal neutron per source neutron, fast neutron dose per epithermal neutron, and photon dose per epithermal neutron. The parameter values are compared to those recommended by the IAEA. Results: The ideal materials for reflector and thermal neutron filter were lead and cadmium, respectively. The thickness for reflector was 43 cm and for filter was 0.5 mm. At present, the best-performing moderator has 25 cm of AlF{sub 3} and 5 cm of MgF{sub 2}. This layout creates a neutron spectrum that has a peak at approximately 10 keV and produces 1.35E-4 epithermal neutrons per source neutron per cm{sup 2}. Additional neutron characteristics, fast neutrons per epithermal neutron and photon per epithermal neutron, are still under investigation. Conclusion: Working is ongoing to optimize the final layout of the BSA. The neutron spectrum at the beam exit window of the final configuration will have the maximum number of epithermal neutrons and limited photon and fast neutron contaminations within the recommended values by IAEA. Future studies will also include phantom experiments to validate the simulation results.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron-beam-shaping assembly for boron neutron-capture therapy

A neutron-beam-shaping assembly consisting of a moderator, a reflector, and an absorber is used to form a therapeutic neutron beam for the boron neutron-capture therapy of malignant tumors at accelerator neutron sources. A new structure of the moderator and reflector is proposed in the present article, and the results of a numerical simulation of the neutron spectrum and of the absorbed dose in a modified Snyder head phantom are presented. The application of a composite moderator and of a composite reflector and the implementation of neutron production at the proton energy of 2.3MeV are shown to permit obtaining a high-quality therapeutic neutron beam.

43 PARTICLE ACCELERATORS↗

Distant Observer™ [SWR-12-09]

Distant Observer™ (DO) is an optical measurement tool, designed for parabolic trough solar collectors, that determines reflector slope error, absorber position error, and the combined errors based on images of the receiver-tube reflection taken from different angles. We have demonstrated that DO can provide a measurement accuracy of 0.25 mrad for the slope and receiver position errors. DO has two implementation versions: ground-based and drone-driven. As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. The Distant Observer™ (DO) tool, developed by engineers at NREL, is a fast and highly accurate tool that provides complete characterization of the performance of the optical components which include the mirror panels and thermal receiver. This tool is very useful for testing both prototype and operational modules. The Distant Observer™ is an optical measurement tool for parabolic solar collectors that measures reflector slope error, absorber position error and the combined errors. Reflector slope errors occur for many reasons including imperfection in structural frame design, manufacturing and assembly. Absorber position error can be caused by poor structural design, poor installation, sag from the absorber weight, or change in the structure over time.

Ihas, Benjamin↗

Two-Exponential Rossi-Alpha Analysis of Copper- and Polyethylene-Reflected Plutonium

The prompt neutron decay constant $\mathcal{α}$, which is used to infer reactivity, is estimated using the Rossi-alpha technique that is predicated on fitting Rossi-alpha histograms. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector-induced phenomenon. Recent work also validated the two-exponential model for shields, a subset of reflectors, but not for reflectors in general. Ultimately, it is desirable to validate the two-exponential model for the general shield. This work will investigate if previous 3 He measurements of plutonium reflected by copper and polyethylene, and replacement measurements where the plutonium is replaced by 252 Cf are suitable for validating the new model. Since the 3 He detectors ( 3 He gas proportional counters embedded in a polyethylene matrix) inherently contain moderating/reflector material (to increase detection efficiency), this work also investigates the use of organic scintillation detectors that can directly detect fast, fission neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

Nano-crystalline silicon solar cell architecture with absorption at the classical 4n2 limit

We develop a periodically patterned conformal photonic-plasmonic crystal based solar architecture for a nano-crystalline silicon solar cell, through rigorous scattering matrix simulations. The solar cell architecture has a periodic array of tapered silver nano-pillars as the back-reflector coupled with a conformal periodic structure at the top of the cell. The absorption and maximal current, averaged over the entire range of wavelengths, for this solar cell architecture is at the semi-classical 4n{sup 2} limit over a range of common thicknesses (500-1500 nm) and slightly above the 4n{sup 2} limit for a 500 nm nc-Si cell. The absorption exceeds the 4n{sup 2} limit, corrected for reflection loss at the top surface. The photonic crystal cell current is enhanced over the flat Ag back-reflector by 60%, for a thick 1000 nm nc-Si layer, where predicted currents exceed 31 mA/cm{sup 2}. The conformal structure at the top surface focuses light within the absorber layer. There is plasmonic concentration of light, with intensity enhancements exceeding 7, near the back reflector that substantially enhances absorption.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dense Seismic Array Study of a Legacy Underground Nuclear Test at the Nevada National Security Site

The complex postdetonation geologic structures that form after an underground nuclear explosion are difficult to constrain because increased heterogeneity around the damage zone affects seismic waves that propagate through the explosion site. Generally, a vertical rubble-filled structure known as a chimney is formed after an underground nuclear explosion that is composed of debris that falls into the subsurface cavity generated by the explosion. Compared with chimneys that collapse fully, leaving a surface crater, partially collapsed chimneys can have remnant subsurface cavities left in place above collapsed rubble. The 1964 nuclear test HADDOCK, conducted at the Nevada test site (now the Nevada National Security Site), formed a partially collapsed chimney with no surface crater. Understanding the subsurface structure of these features has significant national security applications, such as aiding the study of suspected underground nuclear explosions under a treaty verification. In this study, we investigated the subsurface architecture of the HADDOCK legacy nuclear test using hybrid 2D–3D active source seismic reflection and refraction data. The seismic data were acquired using 275 survey shots from the Seismic Hammer (a 13,000 kg weight drop) and 65 survey shots from a smaller accelerated weight drop, both recorded by ~1000 three-component 5 Hz geophones. First-arrival, P-wave tomographic modeling shows a low-velocity anomaly at ~200 m depth, likely an air-filled cavity caused by partial collapse of the rock column into the temporary postdetonation cavity. A high-velocity anomaly between 20 and 60 m depth represents spall-related compaction of the shallow alluvium. Hints of low velocities are also present near the burial depth (~364 m). The reflection seismic data show a prominent subhorizontal reflector at ~300 m depth, a short-curved reflector at ~200 m, and a high-amplitude reflector at ~50 m depth. Comparisons of the reflection sections to synthetic data and borehole stratigraphy suggest that these features correspond to the alluvium–tuff contact, the partial collapse cavity, and the spalled layer, respectively.

58 GEOSCIENCES↗

Small Area Array-Based LED Luminaire Design

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency LED luminaire designs based on small area array-based gallium nitride diodes. Novel GaN-based LED array designs are described, specifically addressing the thermal, optical, electrical and mechanical requirements for the incorporation of such arrays into viable solid-state LED luminaires. This work resulted in the demonstration of an integrated luminaire prototype of 1000 lumens cool white light output with reflector shaped beams and efficacy of 89.4 lm/W at CCT of 6000oK and CRI of 73; and performance of 903 lumens warm white light output with reflector shaped beams and efficacy of 63.0 lm/W at CCT of 2800oK and CRI of 82. In addition, up to 1275 lumens cool white light output at 114.2 lm/W and 1156 lumens warm white light output at 76.5 lm/W were achieved if the reflector was not used. The success to integrate small area array-based LED designs and address thermal, optical, electrical and mechanical requirements was clearly achieved in these luminaire prototypes with outstanding performance and high efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HTR-PROTEUS Pebble Bed Experimental Program Core 4: Random Packing With a 1:1 Moderator-to-Fuel Pebble Ratio

In its deployment as a pebble bed reactor (PBR) critical facility from 1992 to 1996, the PROTEUS facility was designated as HTR-PROTEUS. This experimental program was performed as part of an International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on the Validation of Safety Related Physics Calculations for Low Enriched HTGRs. Within this project, critical experiments were conducted for graphite moderated LEU systems to determine core reactivity, flux and power profiles, reaction-rate ratios, the worth of control rods, both in-core and reflector based, the worth of burnable poisons, kinetic parameters, and the effects of moisture ingress on these parameters. One benchmark experiment was evaluated in this report: Core 4. Core 4 represents the only configuration with random pebble packing in the HTR-PROTEUS series of experiments, and has a moderator-to-fuel pebble ratio of 1:1. Three random configurations were performed. The initial configuration, Core 4.1, was rejected because the method for pebble loading, separate delivery tubes for the moderator and fuel pebbles, may not have been completely random; this core loading was rejected by the experimenters. Cores 4.2 and 4.3 were loaded using a single delivery tube, eliminating the possibility for systematic ordering effects. The second and third cores differed slightly in the quantity of pebbles loaded (40 each of moderator and fuel pebbles), stacked height of the pebbles in the core cavity (0.02 m), withdrawn distance of the stainless steel control rods (20 mm), and withdrawn distance of the autorod (30 mm). The 34 coolant channels in the upper axial reflector and the 33 coolant channels in the lower axial reflector were open. Additionally, the axial graphite fillers used in all other HTR-PROTEUS configurations to create a 12-sided core cavity were not used in the randomly packed cores. Instead, graphite fillers were placed on the cavity floor, creating a funnel-like base, to discourage ordering effects during pebble loading. Core 4 was determined to be acceptable benchmark experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

1.506-cm pitch↗

HTR-proteus pebble bed experimental program core 4: random packing with a 1:1 moderator-to-fuel pebble ratio

In its deployment as a pebble bed reactor (PBR) critical facility from 1992 to 1996, the PROTEUS facility was designated as HTR-PROTEUS. This experimental program was performed as part of an International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on the Validation of Safety Related Physics Calculations for Low Enriched HTGRs. Within this project, critical experiments were conducted for graphite moderated LEU systems to determine core reactivity, flux and power profiles, reaction-rate ratios, the worth of control rods, both in-core and reflector based, the worth of burnable poisons, kinetic parameters, and the effects of moisture ingress on these parameters. One benchmark experiment was evaluated in this report: Core 4. Core 4 represents the only configuration with random pebble packing in the HTR-PROTEUS series of experiments, and has a moderator-to-fuel pebble ratio of 1:1. Three random configurations were performed. The initial configuration, Core 4.1, was rejected because the method for pebble loading, separate delivery tubes for the moderator and fuel pebbles, may not have been completely random; this core loading was rejected by the experimenters. Cores 4.2 and 4.3 were loaded using a single delivery tube, eliminating the possibility for systematic ordering effects. The second and third cores differed slightly in the quantity of pebbles loaded (40 each of moderator and fuel pebbles), stacked height of the pebbles in the core cavity (0.02 m), withdrawn distance of the stainless steel control rods (20 mm), and withdrawn distance of the autorod (30 mm). The 34 coolant channels in the upper axial reflector and the 33 coolant channels in the lower axial reflector were open. Additionally, the axial graphite fillers used in all other HTR-PROTEUS configurations to create a 12-sided core cavity were not used in the randomly packed cores. Instead, graphite fillers were placed on the cavity floor, creating a funnel-like base, to discourage ordering effects during pebble loading. Core 4 was determined to be acceptable benchmark experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

reactivity worth measurements↗

Criticality Safety Evaluation on Generic Fissionable Materia Operations with up to 65 Grams Pu-239

This assessment establishes the criticality safety technical basis for generic fissionable material operations with up to 65 grams Pu-239 in various locations with all moderators and reflectors (including superior moderators and reflectors). These generic fissionable material operations are shown to be criticality safe with inadvertent criticality being incredible (or beyond extremely likely). Therefore, no controls on moderators and reflectors are required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

KiloPower Space Reactor Concept: Reactor Materials Study

This paper presents the logic and analysis used to produce an initial choice of fuel, reflector material and heat pipe placement for the Kilopower reactor concept. Kilopower is a small 4 kWt (1 kWe) space reactor system that uses a highly enriched uranium core with heat pipes to deliver thermal energy to Stirling engines to produce electricity. First, the paper presents the logic behind the initial selection of uranium metal as the base starting point for the fuel over a myriad of other fuel choices. Next, a material study was performed that examined the choices of potential alloy materials for uranium, choices for reflector material and choices for the location of the heat pipes. The results of the material study was a fuel choice of highly enriched uranium alloy with 7% molybdenum, a reflector choice of beryllium oxide, and a choice for the heat pipe placement at the edge of the fuel. This report is a companion document to heat pipe mechanical design performed by NASA Glenn Research and materials research/manufacturing design work performed by NASA Glenn and Y-12.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing Uncertainty and Repeatability in Time-Lapse VSP Monitoring of CO2 Injection in a Brine Aquifer, Frio Formation, Texas (A Case Study)

This study was done to assess the repeatability and uncertainty of time-lapse VSP response to CO 2 injection in the Frio formation near Houston Texas. A work flow was built to assess the effect of time-lapse injected CO 2 into two Frio brine reservoir intervals, the ‘C’ sand (Frio1) and the ‘Blue sand’ (Frio2). The time-lapse seismic amplitude variations with sensor depth for both reservoirs Frio1 and Frio2 were computed by subtracting the seismic response of the base survey from each of the two monitor seismic surveys. Source site 1 has been considered as one of the best sites for evaluating the time-lapse response after injection. For site 1, the computed timelapse NRMS levels after processing had been compared to the estimated time-lapse NRMS level before processing for different control reflectors, and for brine aquifers Frio1, and Frio2 to quantify detectability of amplitude difference. As the main interest is to analyze the time-lapse amplitude variations, different scenarios have been considered. Three different survey scenarios were considered: the base survey which was performed before injection, monitor1 performed after the first injection operation, and monitor2 which was after the second injection. The first scenario was base-monitor1, the second was basemonitor2, and the third was monitor1-monitor2. We considered three ‘control’ reflections above the Frio to assist removal of overburden changes, and concluded that third control reflector (CR3) is the most favorable for the first scenario in terms of NRMS response, and first control reflector (CR1) is the most favorable for the second and third scenarios in terms of NRMS response. The NRMS parameter is shown to be a useful measure to assess the effect of processing on time-lapse data. The overall NRMS for the Frio VSP data set was found to be in the range of 30% to 80% following basic processing. This could be considered as an estimated baseline in assessing the utility of VSP for CO 2 monitoring. This study shows that the CO 2 injection in brine reservoir Frio1 (the ‘C’ sand unit) does induce a relative change in amplitude response, and for Frio2 (the ‘Blue’ sand unit) an amplitude change has been also detected, but in both cases the uncertainty, as measured by NRMS indicates the reservoir changes are, at best, only slightly above the noise level, and often below the noise level of the overall data set.

54 ENVIRONMENTAL SCIENCES↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15) O₂ Fuel Rods (1.506-cm Pitch and 7-Tube Clusters) (Rev. 2)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗