Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

First measurement of the CP -violating phase $ {\phi}_s^{d\overline{d}} $ in B s o → (K + π – )(K – π + ) decays

A flavour-tagged decay-time-dependent amplitude analysis of B s o → (K + π – )(K – π + ) decays is presented in the K ± π ∓ mass range from 750 to 1600MeV/c 2 . The analysis uses pp collision data collected with the LHCb detector at centre-of-mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3.0 fb –1 . Several quasi-two-body decay modes are considered, corresponding to K ± π ∓ combinations with spin 0, 1 and 2, which are dominated by the K o * (800)0 and K o * (1430) o , the K*(892) o and the K 2 * (1430) o resonances, respectively. The longitudinal polarisation fraction for the B 0 s → K*(892)°K¯*(892) 0 decay is measured as f L = 0.208 ± 0.032 ± 0.046, where the first uncertainty is statistical and the second is systematic. The first measurement of the mixing-induced CP -violating phase, $ {\phi}_s^{d\overline{d}} $, in b → dd¯s transitions is performed, yielding a value of $ {\phi}_s^{d\overline{d}} $ = –0.10 ± 0.13 (stat) ± 0.14 (syst) rad.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jet thermalization in QCD kinetic theory

We perform numerical studies in the framework of QCD kinetic theory to investigate the energy and angular profiles of a high energy parton — as a proxy for a jet produced in heavy ion collisions — passing through a Quark-Gluon Plasma (QGP). We find that the fast parton loses energy to the plasma mainly via a radiative turbulent quark and gluon cascade that transports energy locally from the jet down to the temperature scale where dissipation takes place. In this first stage of the system time evolution, the angular structure of the turbulent cascade is found to be relatively collimated. However, when the lost energy reaches the plasma temperature it is rapidly transported to large angles w.r.t. the jet axis and thermalizes. We investigate the contribution of the soft jet constituents to the total jet energy. We show that for jet opening angles of about 0.3 rad or smaller, the effect is negligible. Conversely, larger opening angles become more and more sensitive to the thermal component of the jet and thus to medium response. Our result showcases the importance of the jet cone size in mitigating or enhancing the details of dissipation in jet quenching observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of prostate cancer detection combining a computer-aided diagnostic system with TRUS-MRI targeted biopsy

Purpose: To validate a novel consensus method, called target-in-target, combining human analysis of mpMRI with automated CAD system analysis, with the aim to increasing the prostate cancer detection rate of targeted biopsies. Methods: A cohort of 420 patients was enrolled and 253 patients were rolled out, due to exclusion criteria. 167 patients, underwent diagnostic 3T MpMRI. Two expert radiologists evaluated the exams adopting PI-RADSv2 and CAD system. When a CAD target overlapped with a radiologic one, we performed the biopsy in the overlapping area which we defined as target-in-target. Targeted TRUS-MRI fusion biopsy was performed in 63 patients with a total of 212 targets. The MRI data of all targets were quantitatively analyzed, and diagnostic findings were compared to pathologist’s biopsy reports. Results: CAD system diagnostic performance exhibited sensitivity and specificity scores of 55.2% and 74.1% [AUC = 0.63 (0.54 ÷ 0.71)] , respectively. Human readers achieved an AUC value, in ROC analysis, of 0.71 (0.63 ÷ 0.79). The target-in-target method provided a detection rate per targeted biopsy core of 81.8 % vs. a detection rate per targeted biopsy core of 68.6 % for pure PI-RADS based on target definitions. The higher per-core detection rate of the target-in-target approach was achieved irrespective of the presence of technical flaws and artifacts. Conclusions: A novel consensus method combining human reader evaluation with automated CAD system analysis of mpMRI to define prostate biopsy targets was shown to improve the detection rate per biopsy core of TRUS-MRI fusion biopsies. Results suggest that the combination of CAD system analysis and human reader evaluation is a winning strategy to improve targeted biopsy efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Safety in Interventional Radiology: A CIRSE IR Checklist

Interventional radiology (IR) is an invasive speciality with the potential for complications as with other invasive specialities. The World Health Organization (WHO) produced a surgical safety checklist to decrease the morbidity and mortality associated with surgery. The Cardiovascular and Interventional Society of Europe (CIRSE) set up a task force to produce a checklist for IR. Use of the checklist will, we hope, reduce the incidence of complications after IR procedures. It has been modified from the WHO surgical safety checklist and the RAD PASS from Holland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dispersion Characteristics and Phase Index of One-Dimensional Magnetized Ferrite Photonic Crystals in Transverse Magnetization Configuration for TE Modes

The dispersion characteristics and phase index of magnetized one-dimensional ferrite photonic crystals in transverse magnetization for transverse electric modes are investigated. The dispersion relation and expression for phase index are derived by using transfer matrix method. The effects of structural parameters such as external magnetic fields, filling factor, and β on dispersion properties and phase index are investigated. The dielectric nature of the considered magnetized ferrite photonic crystal structure is demonstrated. Also, the band structure for ω < 1.5 × 10{sup 10} rad s{sup − 1} is strongly affected by external magnetic fields. It is observed that phase index occurs in the form of lobes and is found to be controlled by external magnetic field, β, and filling factor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A chromatography chemistry for purifying $\mathrm{Pa}$ from $\mathrm{U-Nb}$ metal alloys

Here we present a chromatography chemistry for purifying protactinium from uranium metal alloys containing weight-percent concentrations of niobium. Niobium is precipitated in 9 M HCl without the co-precipitation of Pa as demonstrated by gamma-ray spectrometry. Protactinium is further purified using Bio-Rad™ anion resin AG® 1-X8 and 9 M HCl + 0.0128 M HF. A Pa/Nb separation factor of 85,000 and a 90% Pa recovery is demonstrated, which is amenable to 231 Pa concentration determination by isotope dilution and 231 Pa/ 235 U model age calculation for nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Application of HRGS for forensic characterization of uranium oxides, pure uranium metals and uranium alloys

A nondestructive iterative method for uranium-bearing material characterization with HRGS developed earlier in (J. appl. Rad. Isotopes, 166 (2020) 109433) is applied to determine matrix densities and uranium isotope masses of a variety of uranium materials, namely uranium ore, UO 2 and U 3 O 8 powders, fuel elements in the form of UO2 microspheres, uranium metal and uranium alloys. It is shown that U 3 O 8 powders with uranium mass fraction of about 84% can be distinguished from the powders of UO 2 with uranium mass fraction of about 87%; uranium products in the form of liquid or loose powder with matrix density of 0.5-2.0 g/cm 3 can be distinguished from uranium products in the form of compacted fuel elements with matrix density of 6.0-10.0 g/cm 3 and from pure metal uranium and uranium alloys with matrix density of 14.0- 19.0 g/cm 3 . In fuel microspheres based on UO2 the uranium mass fraction 88.02% measured by HRGS is consistent, within the measurement uncertainties, with the results of isotope dilution mass spectrometry 87.76±0.64 % and also is confirmed by X-ray diffraction technique. The uranium mass fraction of the uranium ore estimated as 0.08% by HRGS is consistent, within the measurement uncertainties, with the value 0.09±0.01% determined with WDXRF. Densities of two different uranium metal samples, estimated as 18.42 g/cm 3 and 19.33 g/cm 3 by HRGS are consistent with values 18.24±0.55 g/cm 3 and 18.86±0.59 g/cm 3 , respectively, obtained by the gas pycnometry technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗

Enhance the performance of organic solar cells by nonfused ring electron acceptors bearing a pendent perylenediimide group

A new nonfused ring electron acceptor PDI-DO-2F is designed and synthesized by attaching perylenediimide (PDI) unit as a pendent group to the central donor core. Compared with the control molecule DO-2F, the introduction of PDI lateral substituent can greatly enhance the solubility and decrease the crystallinity of the resulted acceptor. The PBDB-T:PDI-DO-2F blend film exhibits a much better morphology with higher and more balanced carrier mobility in contrast to PBDB-T:DO-2F one. PDI-DO-2F based organic solar cells (OSCs) give a power conversion efficiency (PCE) of 11.78%, higher than DO-2F based ones (9.82%). Furthermore, PDI-DO-2F based OSCs shows a ΔE non-rad value of 0.23 eV, which is significantly lower than the DO-2F based ones (0.28 eV). More importantly, the addition of PDI-DO-2F as the third component to the PBDB-T:DO-2F binary system can optimize the morphology of blend films and improve the shelf stability of devices. Finally, the PBDB-T:DO-2F:PDI-DO-2F based ternary OSCs achieve a higher PCE of 13.82%.

14 SOLAR ENERGY↗

Utilization of optical sensors for phasor measurement units

With the help of GPS signals for synchronization, increasingly ubiquitous phasor measurement units (PMUs) provide power grid operators unprecedented system monitoring and control opportunities. However, the performance of PMUs is limited by the inherent deficiencies in traditional transformers. To address these issues, an optical sensor is used in PMU for signal acquisition to replace the traditional transformers. This is the first time the utilization of an optical sensor in PMUs has ever been reported. The accuracy of frequency, angle, and amplitude are evaluated via experiments. Lastly, the optical sensor based PMU can achieve the accuracy of 9.03 × 10 –4 Hz for frequency, 6.38 × 10 –3 rad for angle and 6.73 × 10 –2 V for amplitude with real power grid signal, demonstrating the practicability of optical sensors in future PMUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of strain in ion implanted 4H-SiC by fringes observed in synchrotron X-ray topography

A novel high energy implantation system has been successfully developed to fabricate 4H-SiC superjunction devices for medium and high voltage via implantation of dopant atoms with multi-energies ranging from 13 to 66 MeV. The significantly higher levels of energy used compared to conventional implantation processes, necessitates detailed characterization of the lattice damage caused by implantation. To achieve this by employing the novel high energy system, 4H-SiC wafer with 12 μm epilayers were blanket implanted by 13.8–65.7 MeV Al atoms. The lattice damages induced by the implantation were primarily characterized by Synchrotron X-ray Plane Wave Topography (SXPWT) and Reciprocal Space Mapping (RSM). Topographs reveal fringe contrast akin to multiple asymmetric diffraction peaks with an angular separation of only 2″ (arcseconds) observed on rocking curves, indicating inhomogeneous strain distribution across the implanted layer. The strain profile of the implanted layer was extracted from the fringe contrast by applying Rocking-curve Analysis by Dynamical Simulation (RADS). In conclusion, the maximum strain value is similar to that measured on the RSM.

A1. Characterization↗

Structural transition in rare earth doped zirconium oxide: A positron annihilation study

Graphical abstract: New microstructural analysis and phase transition of rare earth doped mixed oxide compounds such as: Sm{sub 2−x}Dy{sub x}Zr{sub 2}O{sub 7} (where x = 0.0 ≤ x ≥ 2.0) that are potentially useful as solid oxide fuels, ionic conductors, optoelectronic materials and most importantly as radiation resistant host for high level rad-waste disposal, structural transition in the system is reported through positron annihilation spectroscopy as there is an indication in the X-ray diffraction analysis. Highlights: ► Zirconium oxide material doped with rare earth ions. ► The method of positron annihilation spectroscopy suggests a phase transition in the system. ► The crystal structure transformation from pure pyrochlore to defect fluorite type of structure is shown by X-ray diffraction results. -- Abstract: A series of compounds with the general composition Sm{sub 2−x}Dy{sub x}Zr{sub 2}O{sub 7} (where 0 ≤ x ≥ 2.0) were synthesized by chemical route and characterized by powder X-ray diffraction (XRD) analysis. The rare earth ion namely Sm{sup +3} in the compound was gradually replaced with another smaller and heavier ion, Dy{sup +3} of the 4f series, there by resulting in order–disorder structural transition, which has been studied by positron annihilation lifetime and Doppler broadening spectroscopy. This study reveals the subtle electronic micro environmental changes in the pyrochlore lattice (prevalent due to the oxygen vacancy in anti-site defect structure of the compound) toward its transformation to defect fluorite structure as found in Dy{sub 2}Zr{sub 2}O{sub 7}. A comparison of the changes perceived with PAS as compared to XRD analysis is critically assayed.

36 MATERIALS SCIENCE↗

Superemission of Cr nanolayers

Highlights: • Development of novel nanodevices for superemission generation. • Development of nanolasers based on metal nanofilms. • Development of theory of nanolasers based on metal nanofilms. - Abstract: We continue our studies of metal nanolayers started earlier [1]. Presently, we investigate absorption, emission and superemission in Cr nanolayers. We provide experimental estimates of the energy density and power density of superemission of Cr nanolayers, along with estimates of the diffraction-limited light divergence. We report that the divergence of the superemission along the direction normal to the nanolayer corresponds to that of a point source, with the divergence angle of ca. 0.2 rad. Additionally, we report surprising long-range transfer of the excitation energy in Cr metal films, at macroscopic distances of 1 cm.

36 MATERIALS SCIENCE↗

Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of fast neutron direction in segmented organic detectors using deep learning

A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. Here, the model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved with 100 neutron detection events in a segmented cubic organic scintillator detector with a side length of 46 mm. To reconstruct the source direction with the same angular resolution as the double-scatter algorithm, the deep learning method requires 75% fewer events. Application of this method could augment the operation of segmented detectors operated in the neutron scatter camera configuration for applications such as special nuclear material detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-pole wigglers at NSLS-II

The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. Here, this paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.

36 MATERIALS SCIENCE↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

Integration of high confinement, high poloidal beta plasma with dual radiated power and detachment controls for divertor protection and ELM suppression

Divertor detachment without serious core confinement quality loss in DIII-D’s high poloidal β scenario has been combined with impurity-induced ELM mitigation without disruption. Use of Ne previously granted access to a detached, non-ELMing regime that retained high confinement quality due to stimulation of Internal Transport Barrier (ITB) growth, but suffered from on-going core fuel dilution and high disruptivity. Excess Ne accumulation in the core plasma has now been avoided by feeding back core radiated power ($P_{rad}$) measurements to control Ne seeding, rather than using attachment fraction ($A_{frac}$) control with Ne; this also reduces disruptivity. At the same time, N 2 seeding is used in a feedback loop with $A_{frac}$ measurements, which previously posed low disruption risk. In this way, the effect of Ne in the core is managed while avoiding excess seeding, and N 2 acts to correct for any excess heat exhaust that might interfere with detachment. The average Ne flow rate was 38% of what was used in pure Ne $A_{frac}$ control, plus average N 2 flow that was 43% of pure N 2 $A_{frac}$ control, even while meeting an even deeper detachment target. Meanwhile, a steep pressure gradient in the core plasma reduces sensitivity to impurity-induced degradation of the pedestal and reasonable confinement quality was maintained despite operational challenges that blocked formation of an ITB in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗