Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

History of satellite break-ups in space

By 28 June 1961 the 1st Aerospace Control Squadron had cataloged 115 Earth orbiting satellites from data supplied by a rather diverse collection of radar and optical sensors. On 29 June 1961, the Able Star rocket of the 1961 Omicron launch exploded causing a quantum jump in the number of Earth orbiting objects. Since that time there have been 69 Earth orbiting satellites break up in space whose debris remained in orbit long enough for orbital elements to be developed. A list of the 69 breakups is provided. The debris from some of the lower altitude breakups has all decayed. Among the 69 breakups, 44 have cataloged debris remaining in orbit. As of 1 July 1982, the size of the cataloged orbiting population was exactly 4700. Forty-nine percent of these objects are fragments of the forty-four breakups. For each breakup the various orbits of its debris represent a family of orbits that are related in characteristics due to their common impulse launch. A few examples are shown of how the families are oriented in space.

Gabbard, J.↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Experience with 800 x 800 virtual phase and 500 x 500 three-phase CCD imagers

A description of the Galileo/Institute for Astronomy charge-coupled device (CCD) imaging system and its initial operation has been presented previously. Originally designed to operate a 500 x 500 backside illuminated three-phase CCD, the system has been modified to allow use of either the 500 x 500 sensor or the TI 800 x 800 virtual phase CCD. The modifications for the operation of the virtual phase CCD and current system performance with each type of sensor are discussed. A description is given of the implementation of various techniques discovered at the Jet Propulsion Laboratory that improve imager performance. These techniques include tri-level clocking of the virtual phase CCD to eliminate spurious charge generation in the serial register, the use of ultraviolet light flood with the backside thinned 500 x 500 three-phase device to dramatically improve the quantum efficiency in the blue, and the practical elimination of deferred charge in the three-phase device. Results of astronomical observations with each sensor are presented.

Hlivak, R. J.↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Magnetic‐Field‐Switchable Laser via Optical Pumping of Rubrene

Abstract Volumetric optical imaging of magnetic fields is challenging with existing magneto‐optical materials, motivating the search for dyes with strong magnetic field interactions, distinct emission spectra, and an ability to withstand high photon flux and incorporation within samples. Here, the magnetic field effect on singlet‐exciton fission is exploited to demonstrate spatial imaging of magnetic fields in a thin film of rubrene. Doping rubrene with the high‐quantum yield dye dibenzotetraphenylperiflanthene (DBP) is shown to enable optically pumped, slab waveguide lasing. This laser is magnetic‐field‐switchable: when operated just below the lasing threshold, application of a 0.4 T magnetic field switches the device between nonlasing and lasing modes, accompanied by an intensity modulation of +360%. This is thought to be the first demonstration of a magnetically switchable laser, as well as the largest magnetically induced change in emission brightness in a singlet‐fission material to date. These results demonstrate that singlet‐fission materials are promising materials for magnetic sensing applications and could inspire a new class of magneto‐optical modulators.

36 MATERIALS SCIENCE↗

Searching for axion dark matter with array-scalable single magnon detectors

We introduce an array-scalable, magnon-based detector to search for the spin-dependent interactions of electron-coupled axion dark matter with mass in the 1−100 μ⁢eV range. These axions can excite single magnons in magnetic targets, such as yttrium iron garnet (YIG) spheres, which are subsequently sensed by the detector. In our concept, this sensing is implemented by coupling the magnons in the YIG spheres to magnetic-field-resilient single-electron charge-qubits, whose state is then interrogated with a quantum nondemolition measurement. Using standard superconducting fabrication techniques, it is possible to integrate many YIG sphere-qubit sensors, forming a large detector array. We outline the detector design and operation for our concept, and determine its sensitivity to axion dark matter. We find that using available technology can already exceed the sensitivity of previous ferromagnetic haloscopes, and further improvements in performance would search for electron-coupled axion dark matter in unexplored parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and evaluation of television tubes for space astronomy

An improved vidicon image sensor for space astronomy applications is developed that features reliably sealed ultraviolet transmitting windows and achieves acceptable photocathode quantum efficiency on these MgF2 windows. New preamplifier designs improve the dynamic range by reduction of the readout noise.

Spitzer, L.↗

Laser Remote Sensing at NASA

NASA is developing active remote sensors to monitor the health of Planet Earth and for exploration of other planets. Development and deployment of these remote sensors can have a huge economic impact. Lasers for these active remote sensors span the spectral range from the ultraviolet to the mid infrared spectral regions. Development activities range from quantum mechanical modeling and prediction of new laser materials to the design, development, and demonstration be deployed in the field.

Barnes, Norman P.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

Performance of the QWIP Focal Plane Arrays for NASA's Landsat Data Continuity Mission

The focal plane assembly for the Thermal Infrared Sensor (TIRS) instrument on NASA's Landsat Data Continuity Mission (LDCM) consists of three 512 x 640 GaAs Quantum Well Infrared Photodetector (QWIP) arrays. The three arrays are precisely mounted and aligned on a silicon carrier substrate to provide a continuous viewing swath of 1850 pixels in two spectral bands defined by filters placed in close proximity to the detector surfaces. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). QWIP arrays were evaluated from four laboratories; QmagiQ, (Nashua, NH), Army Research Laboratory, (Adelphi, MD}, NASA/ Goddard Space Flight Center, (Greenbelt, MD) and Thales, (Palaiseau, France). All were found to be suitable. The final discriminating parameter was the spectral uniformity of individual pixels relative to each other. The performance of the QWIP arrays and the fully assembled, NASA flight-qualified, focal plane assembly will be reviewed. An overview of the focal plane assembly including the construction and test requirements of the focal plane will also be described.

Jhabvala, M.↗

Fluorescent compositions

A fluorescent composition includes at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Holographic wavefront sensors

A brief historical review of the first designs of holographic wavefront sensors (WFS’s) and the concepts lying in their basis is presented. The main directions in the development of these sensors are highlighted and considered. One of these directions implies a two-stage transition from the use of several separate measuring channels with holograms filtering only one Zernike mode: first to the use of one channel with a multiplexed hologram filtering several first Zernike modes, and then to filtering the entire set of Zernike modes with the aid of one combined multiplexed hologram. Another line of research in this field (related to the first one) is the optimisation of the filter hologram structure in order to reduce cross-modulation interferences, increase multiplexing level, etc. One more line of research implements principles of dynamic holography by introducing spatial light modulators into the WFS composition. Hence, the advantages of time multiplexing of holograms can be used. The approach developed by G. Andersen’s team, aimed at adapting the holographic WFS design for operation as an element of adaptive optical system with a zonal corrector, as well as an approach implying development of hybrid holographic sensors, are considered separately. The results of the authors’ studies of holographic WFS’s with application of the methods of Fourier holography (i.e., holography of focused beams, in particular, using diffuse scatterers in a hologram recording channel) are also reported. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress towards a space-borne quantum gravity gradiometer

Quantum interferometer gravity gradiometer for 3D mapping is a project for developing the technology of atom interferometer-based gravity sensor in space. The atom interferometer utilizes atomic particles as free fall test masses to measure inertial forces with unprecedented sensitivity and precision. It also allows measurements of the gravity gradient tensor components for 3D mapping of subsurface mass distribution. The overall approach is based on recent advances of laser cooling and manipulation of atoms in atomic and optical physics. Atom interferometers have been demonstrated in research laboratories for gravity and gravity gradient measurements. In this approach, atoms are first laser cooled to micro-kelvin temperatures. Then they are allowed to freefall in vacuum as true drag-free test masses. During the free fall, a sequence of laser pulses is used to split and recombine the atom waves to realize the interferometric measurements. We have demonstrated atom interferometer operation in the Phase I period, and we are implementing the second generation for a complete gradiometer demonstration unit in the laboratory. Along with this development, we are developing technologies at component levels that will be more suited for realization of a space instrument. We will present an update of these developments and discuss the future directions of the quantum gravity gradiometer project.

laser cooling↗