Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Detecting fractionalization in critical spin liquids using color centers

Quantum spin liquids are highly entangled ground states of insulating spin systems, in which magnetic ordering is prevented down to the lowest temperatures due to quantum fluctuations. One of the most extraordinary characteristics of quantum spin liquid phases is their ability to support fractionalized, low-energy quasiparticles known as spinons, which carry spin-1/2 but bear no charge. Relaxometry based on color centers in crystalline materials—of which nitrogen-vacancy (NV) centers in diamond are a well-explored example—provides an exciting new platform to probe the spin spectral functions of magnetic materials with both energy and momentum resolution and to search for signatures of these elusive, fractionalized excitations. In this work, we theoretically investigate the color-center relaxometry of two archetypal quantum spin liquids: the two-dimensional U(1) quantum spin liquid with a spinon Fermi surface and the spin-1/2 antiferromagnetic spin chain. The former is characterized by a metallic, spin-split ground state of mobile, interacting spinons, which closely resembles a spin-polarized Fermi liquid ground state but with neutral quasiparticles. We show that the observation of the Stoner continuum and the collective spin wave mode in the spin spectral function would provide a strong evidence for the existence of spinons and fractionalization. In one dimension, mobile spinons form a Luttinger liquid ground state. We show that the spin spectral function exhibits strong features representing the collective density and spin-wave modes, which are broadened in an algebraic fashion with an exponent characterized by the Luttinger parameter. The possibilities of measuring these collective modes and detecting the power-law decay of the spectral weight using NV relaxometry are discussed. We also examine how the transition rates are modified by marginally irrelevant operators in the Heisenberg limit. Published by the American Physical Society 2024

Takei, So (ORCID:0000000191771895)↗

Hardware-Efficient Quantum Optimization Layered Algorithms and Experiments

Quantum optimization algorithms, such as QAOA, that implement parametrized stochastic optimization solvers attempt to identify low-energy solutions of Ising systems by exploiting available quantum effects in noisy-intermediate scale machines. Engineering a well-performing parametrized quantum optimization circuit is indeed an exercise in balancing the trade-off between expressivity and implementation complexity. We show that, for MaxCut QAOA circuits defined on native hardware topology (Rigetti’s Aspen Quantum Processors), error-mitigation techniques recover simulated features of the noiseless theory. Moreover, we explore a design space for QAOA-like ansatze that perform well in theory as well as in hardware for fully-connected problems. We also discuss how efficient coherence and entanglement detection methods that could be coupled with quantum optimization experiments require only linear overhead in benchmarking time.

quantum computing↗

Self-Calibration and Laser Energy Monitor Validations for a Double-Pulsed 2-Micron CO2 Integrated Path Differential Absorption Lidar Application

Double-pulsed 2-micron integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photo-electromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-micron IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.

Refaat, Tamer F.↗

State-to-State Molecular Reactions in the Ultracold Regime (Final Scientific Report)

We have achieved the proposed goal to experimentally probe the AB + CD and AB + C types of reactions with state-to-state resolution, which we also compared to advanced theoretical calculations to help elucidate the role of quantum mechanics in the processes of bond breakage and formation. Our approach uses reactants that are prepared at ultracold temperatures (< 1µK) such that the quantum effects of translational motion are an important factor. Specific example reactions, including the potassium-rubidium metathesis reaction KRb + KRb → K 2 + Rb 2 as well as the atom exchange reaction Rb + KRb → Rb2 + K, are chosen because the technology of quantum internal and motional state control of these types of molecules is particularly advanced. The results for the entire funding period are fruitful. For the majority of this grant, we have constructed a one-of-the-kind quantum degenerate gas apparatus that integrates ion detection and velocity map imaging capabilities, allowing us to explore the KRb + KRb → K 2 + Rb 2 bimolecular reaction in detail. Specifically, we first verified such a reaction indeed proceed at ultracold temperatures by direct detection of reaction products. We then mapped out the complete product state distribution, which was compared to a state-counting model based on statistical theory. Our results show an overall agreement with the statistical state counting model, but also reveal several deviating state-pairs. An exact quantum calculation for molecule-molecule collisions, that is needed to understand these deviations, is however beyond the current state-of-the-art. Beside scrutinizing the reaction products, we also directly observe the reaction intermediate complex, which was quite a surprise to us. The intermediate complexes are long-lived and can interact with the inferred light that we use to trap the ultracold gas. After molecule-molecule collisions, we then explored the more theoretically tractable Rb + KRb reaction, which is endothermic. Surprisingly, we observed an exceedingly long-lived KRb$^*_2$ collisional complexes, with our experimentally measured complex lifetime deviating from conventional theoretical calculations by five orders of magnitude. This discrepancy has motivated many explorations of possible underlying causes, though no model yet captures this phenomenon completely. In the final year and the work that continues today, we extend upon these atom-molecule collision experiments to explore the origin of the long-lived KRb$^*_2$ complex lifetime and develop means to control the outcome of the reaction complex. The 5-year funded work advanced our understanding of chemical reactions at the lowest possible temperatures and at the same time opened up many new questions that are beyond our initial imaginations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UV hybrid photon detector based on GaN photocathodes and Si low gain avalanche diode

Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.

47 OTHER INSTRUMENTATION↗

Enhanced detection of volatile organic compounds (VOCs) by caffeine modified carbon nanotube junctions

Detection of vapor phase analytes and gas molecules is primarily essential for numerous applications including medical diagnostic, environmental monitoring, chemical threat detection, food quality control, and chemical warfare agents. Here, we developed Caffeine functionalized carbon nanotubes (CNTs) random network based vapor quantum resistive sensors (vQRSs) for volatile organic compounds (VOCs) detection. The localized transmission electron microscopy (TEM) image and energy dispersive X-ray spectroscopy (EDS) confirm migration of caffeine to CNT–CNT junction (CNTj). We have recorded more than one order of magnitude higher sensitivity and unique selectivity towards selective VOCs (e.g., acetone, toluene, ethanol, methanol, etc.) with short response time (few seconds) for caffeine modified CNT junction (Caf-CNTj) vQRSs. Molecular dynamics (MD) calculations suggest that the sensitivity of the sensor is diffusion limited, with an advective contribution for ethanol. Furthermore, the designed Caf-CNTj sensors can potentially be important candidate to be a part of electronic nose used for various application such as breath analysis and food quality monitoring.

36 MATERIALS SCIENCE↗

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging the electronic and magnetic structure of topological-superconductor proximity systems (Final Report)

The primary goals of the projects supported by this grant involved developing methods to detect and control electronic states that can aid in the construction of quantum-information devices, including quantum computers. Two types of materials are needed to create these electronic states: superconductors and topological insulators. The interplay of the quantum mechanics of these materials can give rise to elusive states known as Majorana fermions. Majorana Fermions have incredible potential for quantum technology; they can in principle encode quantum information non-locally, and can thus form the basis of especially robust qubits – the basic building blocks of quantum computers. A centerpiece goal of this work was to develop a Majorana detection tool called a Scanning Majorana Microscope. This tool was successfully developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Short-cavity squeezing in barium

Broadband phase sensitive noise and squeezing were experimentally observed in a system of barium atoms interacting with a single mode of a short optical cavity. Squeezing of 13 +/- 3 percent was observed. A maximum possible squeezing of 45 +/- 8 percent could be inferred for out experimental conditions, after correction for measured loss factors. Noise reductions below the quantum limit were found over a range of detection frequencies 60-170 MHz and were best for high cavity transmission and large optical depths. The amount of squeezing observed is consistent with theoretical predictions from a full quantum statistical model of the system.

Hope, D. M.↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Goodrich, Justin C. [Brookhaven National Laborator↗

Characterizing Rocky and Gaseous Exoplanets with 2 m Class Space-based Coronagraphs

Several concepts now exist for small, space-based missions to directly characterize exoplanets in reflected light. While studies have been performed that investigate the potential detection yields of such missions, little work has been done to understand how instrumental and astrophysical parameters will affect the ability of these missions to obtain spectra that are useful for characterizing their planetary targets. Here, we develop an instrument noise model suitable for studying the spectral characterization potential of a coronagraph-equipped, space-based telescope. We adopt a baseline set of telescope and instrument parameters appropriate for near-future planned missions like WFIRST-AFTA, including a 2 m diameter primary aperture, an operational wavelength range of 0.4–1.0 μm, and an instrument spectral resolution of λ/Δλ =70, and apply our baseline model to a variety of spectral models of different planet types, including Earth twins, Jupiter twins, and warm and cool Jupiters and Neptunes. With our exoplanet spectral models, we explore wavelength-dependent planet–star flux ratios for main-sequence stars of various effective temperatures and discuss how coronagraph inner and outer working angle constraints will influence the potential to study different types of planets. For planets most favorable to spectroscopic characterization—cool Jupiters and Neptunes as well as nearby super-Earths—we study the integration times required to achieve moderate signal-to-noise ratio spectra. We also explore the sensitivity of the integration times required to either detect the bottom or presence of key absorption bands (for methane, water vapor, and molecular oxygen) to coronagraph raw contrast performance, exozodiacal light levels, and the distance to the planetary system. Decreasing detector quantum efficiency at longer visible wavelengths makes the detection of water vapor in the atmospheres of Earth-like planets extremely challenging, and also hinders detections of the 0.89 μm methane band. Additionally, most modeled observations have noise dominated by dark currents, indicating that improving CCD performance could substantially drive down requisite integration times. Finally, we briefly discuss the extension of our models to a more distant future Large UV-Optical-InfraRed (LUVOIR) mission.

Astrobiology↗

Vector Electrometry in a Wide-Gap-Semiconductor Device Using a Spin-Ensemble Quantum Sensor

Nitrogen-vacancy (N-V) centers in diamond work as a quantum electrometer. Using an ensemble state of N-V centers, we propose vector electrometry and demonstrate measurements in a diamond electronic device. A transverse electric field applied to the N-V axis under a high voltage is measured, while applying a transverse magnetic field. The response of the energy-level shift against the electric field is significantly enhanced compared with that against an axial magnetic field. Repeating the measurement of the transverse electric field for multiple N-V axes, our team obtains the components of the electric field generated in the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗