Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Habitat quality influences trade-offs in animal movement along the exploration–exploitation continuum

Abstract To successfully establish itself in a novel environment, an animal must make an inherent trade-off between knowledge accumulation and exploitation of knowledge gained (i.e., the exploration–exploitation dilemma). To evaluate how habitat quality affects the spatio-temporal scale of switching between exploration and exploitation during home range establishment, we conducted experimental trials comparing resource selection and space-use of translocated animals to those of reference individuals using reciprocal translocations between habitat types of differing quality. We selected wild pigs ( Sus scrofa ) as a model species to investigate hypotheses related to the movement behavior of translocated individuals because they are globally distributed large mammals that are often translocated within their introduced range to facilitate recreational hunting. Individuals translocated to higher quality habitat (i.e. higher proportions of bottomland hardwood habitats) exhibited smaller exploratory movements and began exploiting resources more quickly than those introduced to lower quality areas, although those in lower-quality areas demonstrated an increased rate of selection for preferred habitat as they gained knowledge of the landscape. Our data demonstrate that habitat quality mediates the spatial and temporal scale at which animals respond behaviorally to novel environments, and how these processes may determine the success of population establishment.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancement in the structure quality of ZnO nanorods by diluted Co dopants: Analyses via optical second harmonic generation

We report a systematic study about the effect of cobalt concentration in the growth solution over the crystallization, growth, and optical properties of hydrothermally synthesized Zn{sub 1−x}Co{sub x}O [0 ≤ x ≤ 0.40, x is the weight (wt.) % of Co in the growth solution] nanorods. Dilute Co concentration of 1 wt. % in the growth solution enhances the bulk crystal quality of ZnO nanorods, and high wt. % leads to distortion in the ZnO lattice that depresses the crystallization, growth as well as the surface structure quality of ZnO. Although, Co concentration in the growth solution varies from 1 to 40 wt. %, the real doping concentration is limited to 0.28 at. % that is due to the low growth temperature of 80 °C. The enhancement in the crystal quality of ZnO nanorods at dilute Co concentration in the solution is due to the strain relaxation that is significantly higher for ZnO nanorods prepared without, and with high wt. % of Co in the growth solution. Second harmonic generation is used to investigate the net dipole distribution from these coatings, which provides detailed information about bulk and surface structure quality of ZnO nanorods at the same time. High quality ZnO nanorods are fabricated by a low-temperature (80 °C) hydrothermal synthesis method, and no post synthesis treatment is needed for further crystallization. Therefore, this method is advantageous for the growth of high quality ZnO coatings on plastic substrates that may lead toward its application in flexible electronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field quality of the 4.5 m-long MQXFA pre-series magnets for the HL-LHC Upgrade as observed during magnet assembly

We report that the U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb 3 Sn quadrupole magnets for the HL-LHC upgrade at CERN. Five pre-series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements on the coil-pack sub-assembly and magnets after loading to track the field quality for two purposes. First, it serves as a quality assurance tool to check if the magnetic field quality is on track to meet the acceptance criteria. Magnetic measurements are used to understand if magnetic shims are needed to compensate low-order field errors and to meet the field quality targets. Second, the measurements during the assembly stage can also help understand the field quality, especially the geometric field errors, for Nb 3 Sn accelerator magnets. Here we summarize the measurement results of the pre-series MQXFA magnets, including the magnetic axis and twist angle. The results will provide useful feedback for the series production of Nb 3 Sn magnets and on the optimization of field quality of accelerator magnets based on the wind-and-react Nb 3 Sn technology.

43 PARTICLE ACCELERATORS↗

Hydrologic and water quality impacts of biofuel feedstock production in the Ohio River Basin

Abstract This study addresses the uncertainties related to potential changes in land use and management and associated impacts on hydrology and water quality resulting from increased production of biofuel from the conventional and cellulosic feedstock. The Soil Water Assessment Tool ( SWAT ) was used to assess the impacts on regional and field scale evapotranspiration, soil moisture content, stream flow, sediment, and nutrient loadings in the Ohio River Basin. The model incorporates spatially and temporally detailed hydrologic, climate and agricultural practice data that are pertinent to simulate biofuel feedstock production, watershed hydrology and water quality. Three future biofuel production scenarios in the region were considered, including a feedstock projection from the DOE Billion‐Ton (BT2) Study, a change in corn rotations to continuous corn, and harvest of 50% corn stover. The impacts were evaluated on the basis of relative changes in hydrology and water quality from historical baseline and future business‐as‐usual conditions of the basin. The overall impact on water quality is an order of magnitude higher than the impact on hydrology. For all the three future scenarios, the sub‐basin results indicated an overall increase in annual evapotranspiration of up to 6%, a decrease in runoff up to 10% and minimal change in soil moisture. The sediment and phosphorous loading at both regional and field levels increased considerably (up to 40–90%) for all the biofuel feedstock scenario considered, while the nitrogen loading increased up to 45% in some regions under the BT2 Study scenario, decreased up to 10% when corn are grown continuously instead of in rotations, and changed minimally when 50% of the stover are harvested. Field level analyses revealed significant variability in hydrology and water quality impacts that can further be used to identify suitable locations for the feedstock productions without causing major impacts on water quantity and quality.

09 BIOMASS FUELS↗

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of the beam quality index of high-energy photon beams under nonstandard reference conditions

Purpose: At some modern radiotherapy machines it is not possible to achieve reference conditions for the measurement of beam quality indices used in dosimetry codes of practice, such as IAEA TRS-398 and AAPM TG-51. This work aims at providing self-consistent and simpler expressions and more accurate fits for a limited range of beams of interest than have been proposed previously for deriving these beam quality indices from measurements. Methods: The starting point is a formula proposed by Sauer [Med. Phys. 36, 4168-4172 (2009)] for deriving the beam quality index used in IAEA TRS-398, TPR{sub 20,10}, from a measurement of the tissue phantom ratio at depths of 20 cm and 10 cm in water for an s Multiplication-Sign s cm{sup 2} (equivalent) square field, TPR{sub 20,10}(s). First, a self-consistent version of this formula is established followed by a simpler version by making a linear approximation. A similar approach is proposed to derive the beam quality index used in AAPM TG-51, %dd(10){sub X}, from a measurement of PDD{sub 10}(s), the percentage depth dose at 10 cm for a square field with size s. All models were fitted to subsets of relevant data from BJR supplement 25. Results: The linear models for TPR{sub 20,10}(s) and exponential models for PDD{sub 10}(s) as a function of the (equivalent) square field size can reproduce the beam quality within 0.3% and beam quality correction factors within 0.05% for square field sizes ranging from 4 cm to 12 cm and nominal photon energies from 4 MV to 12 MV. For higher energy beams the errors are only slightly worse but for %dd(10){sub X}, an additional uncertainty component has to be considered for the electron contamination correction. Conclusions: The models proposed here can be used in practical recommendations for the dosimetry of small and nonstandard fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci—Fri AM: Mountain — 02: A comparison of dose reduction methods on image quality for cone beam CT

Modern radiotherapy uses highly conformai dose distributions and therefore relies on daily image guidance for accurate patient positioning. Kilovoltage cone beam CT is one technique that is routinely used for patient set-up and results in a high dose to the patient relative to planar imaging techniques. This study uses an Elekta Synergy linac equipped with XVI cone beam CT to investigate the impact of various imaging parameters on dose and image quality. Dose and image quality are assessed as functions of x-ray tube voltage, tube current and the number of projections in the scan. In each case, the dose measurements confirm that as each parameter increases the dose increases. The assessment of high contrast resolution shows little dependence on changes to the image technique. However, low contrast visibility suggests a trade off between dose and image quality. Particularly for changes in tube potential, the dose increases much faster as a function of voltage than the corresponding increase in low contrast image quality. This suggests using moderate values of the peak tube voltage (100 – 120 kVp) since higher values result in significant dose increases with little gain in image quality. Measurements also indicate that increasing tube current achieves the greatest degree of improvement in the low contrast visibility. The results of this study highlight the need to establish careful imaging protocols to limit dose to the patient and to limit changes to the imaging parameters to those cases where there is a clear clinical requirement for improved image quality.

60 APPLIED LIFE SCIENCES↗

The image quality of ion computed tomography at clinical imaging dose levels

Purpose: Accurately predicting the range of radiotherapy ions in vivo is important for the precise delivery of dose in particle therapy. Range uncertainty is currently the single largest contribution to the dose margins used in planning and leads to a higher dose to normal tissue. The use of ion CT has been proposed as a method to improve the range uncertainty and thereby reduce dose to normal tissue of the patient. A wide variety of ions have been proposed and studied for this purpose, but no studies evaluate the image quality obtained with different ions in a consistent manner. However, imaging doses ion CT is a concern which may limit the obtainable image quality. In addition, the imaging doses reported have not been directly comparable with x-ray CT doses due to the different biological impacts of ion radiation. The purpose of this work is to develop a robust methodology for comparing the image quality of ion CT with respect to particle therapy, taking into account different reconstruction methods and ion species. Methods: A comparison of different ions and energies was made. Ion CT projections were simulated for five different scenarios: Protons at 230 and 330 MeV, helium ions at 230 MeV/u, and carbon ions at 430 MeV/u. Maps of the water equivalent stopping power were reconstructed using a weighted least squares method. The dose was evaluated via a quality factor weighted CT dose index called the CT dose equivalent index (CTDEI). Spatial resolution was measured by the modulation transfer function. This was done by a noise-robust fit to the edge spread function. Second, the image quality as a function of the number of scanning angles was evaluated for protons at 230 MeV. In the resolution study, the CTDEI was fixed to 10 mSv, similar to a typical x-ray CT scan. Finally, scans at a range of CTDEI’s were done, to evaluate dose influence on reconstruction error. Results: All ions yielded accurate stopping power estimates, none of which were statistically different from the ground truth image. Resolution (as defined by the modulation transfer function = 10% point) was the best for the helium ions (18.21 line pairs/cm) and worst for the lower energy protons (9.37 line pairs/cm). The weighted quality factor for the different ions ranged from 1.23 for helium to 2.35 for carbon ions. For the angle study, a sharp increase in absolute error was observed below 45 distinct angles, giving the impression of a threshold, rather than smooth, limit to the number of angles. Conclusions: The method presented for comparing various ion CT modalities is feasible for practical use. While all studied ions would improve upon x-ray CT for particle range estimation, helium appears to give the best results and deserves further study for imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time

Purpose: The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. Methods: For three nasopharyngeal patients, the authors generated treatment plans for nine different delivery scenarios using dedicated optimization methods. They compared these scenarios according to dose characteristics, number of beam directions, and estimated delivery times. In particular, the authors generated the following treatment plans: (1) a 4π plan, which is a not sequenced, fluence optimized plan that uses beam directions from approximately 1400 noncoplanar directions and marks a theoretical upper limit of the treatment plan quality, (2) a coplanar 2π plan with 72 coplanar beam directions as pendant to the noncoplanar 4π plan, (3) a coplanar VMAT plan, (4) a coplanar step and shoot (SnS) plan, (5) a beam angle optimized (BAO) coplanar SnS IMRT plan, (6) a noncoplanar BAO SnS plan, (7) a VMAT plan with rotated treatment couch, (8) a noncoplanar VMAT plan with an optimized great circle around the patient, and (9) a noncoplanar BAO VMAT plan with an arbitrary trajectory around the patient. Results: VMAT using optimized noncoplanar irradiation trajectories reduced the mean and maximum doses in organs at risk compared to coplanar VMAT plans by 19% on average while the target coverage remains constant. A coplanar BAO SnS plan was superior to coplanar SnS or VMAT; however, noncoplanar plans like a noncoplanar BAO SnS plan or noncoplanar VMAT yielded a better plan quality than the best coplanar 2π plan. The treatment plan quality of VMAT plans depended on the length of the trajectory. The delivery times of noncoplanar VMAT plans were estimated to be 6.5 min in average; 1.6 min longer than a coplanar plan but on average 2.8 min faster than a noncoplanar SnS plan with comparable treatment plan quality. Conclusions: The authors’ study reconfirms the dosimetric benefits of noncoplanar irradiation of nasopharyngeal tumors. Both SnS using optimized noncoplanar beam ensembles and VMAT using an optimized, arbitrary, noncoplanar trajectory enabled dose reductions in organs at risk compared to coplanar SnS and VMAT. Using great circles or simple couch rotations to implement noncoplanar VMAT, however, was not sufficient to yield meaningful improvements in treatment plan quality. The authors estimate that noncoplanar VMAT using arbitrary optimized irradiation trajectories comes at an increased delivery time compared to coplanar VMAT yet at a decreased delivery time compared to noncoplanar SnS IMRT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol

Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoring function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.

60 APPLIED LIFE SCIENCES↗

Improved quality of intrafraction kilovoltage images by triggered readout of unexposed frames

Purpose: The gantry-mounted kilovoltage (kV) imager of modern linear accelerators can be used for real-time tumor localization during radiation treatment delivery. However, the kV image quality often suffers from cross-scatter from the megavoltage (MV) treatment beam. This study investigates readout of unexposed kV frames as a means to improve the kV image quality in a series of experiments and a theoretical model of the observed image quality improvements. Methods: A series of fluoroscopic images were acquired of a solid water phantom with an embedded gold marker and an air cavity with and without simultaneous radiation of the phantom with a 6 MV beam delivered perpendicular to the kV beam with 300 and 600 monitor units per minute (MU/min). An in-house built device triggered readout of zero, one, or multiple unexposed frames between the kV exposures. The unexposed frames contained part of the MV scatter, consequently reducing the amount of MV scatter accumulated in the exposed frames. The image quality with and without unexposed frame readout was quantified as the contrast-to-noise ratio (CNR) of the gold marker and air cavity for a range of imaging frequencies from 1 to 15 Hz. To gain more insight into the observed CNR changes, the image lag of the kV imager was measured and used as input in a simple model that describes the CNR with unexposed frame readout in terms of the contrast, kV noise, and MV noise measured without readout of unexposed frames. Results: Without readout of unexposed kV frames, the quality of intratreatment kV images decreased dramatically with reduced kV frequencies due to MV scatter. The gold marker was only visible for imaging frequencies ≥3 Hz at 300 MU/min and ≥5 Hz for 600 MU/min. Visibility of the air cavity required even higher imaging frequencies. Readout of multiple unexposed frames ensured visibility of both structures at all imaging frequencies and a CNR that was independent of the kV frame rate. The image lag was 12.2%, 2.2%, and 0.9% in the first, second, and third frame after an exposure. The CNR model predicted the CNR with triggered image readout with a mean absolute error of 2.0% for the gold marker. Conclusions: A device that triggers readout of unexposed frames during kV fluoroscopy was built and shown to greatly improve the quality of intratreatment kV images. A simple theoretical model successfully described the CNR improvements with the device.

60 APPLIED LIFE SCIENCES↗

Accuracy-Based Annotation Quality Score (ABAQS) v1.0

Assessing genome annotation quality is crucial for downstream analyses, but current methods are inadequate for eukaryotes. We present Accuracy-Based Annotation Quality Score (ABAQS), a novel, minimal-data-driven method that comprehensively assesses annotation quality. ABAQS evaluates multiple factors, including genome completeness, gene model validity, and protein profile accuracy, outperforming other metrics like BUSCO and PSAURON. We applied ABAQS to over 2500 eukaryotic genomes and showed its robustness and effectiveness in evaluating genome annotation quality, making it a valuable tool for researchers working with genomic data. ABAQS reveals significant variation in annotation quality and highlights the importance of filtering in improving annotation quality and accuracy.

Haridas, Sajeet [Lawrence Berkeley National Labora↗

The History of Quality in Industry

The quality movement’s long history traces back to the Industrial Revolution and continues through the more modern concepts of Total Quality Management (TQM). This report provides an overview of the history of quality in industry, from its roots through its later movements, including quality inspections, the statistical quality control methods championed by W. Edwards Deming and others, and the influence of Japanese quality management on current American industrial practices.

Kolb, Rachel R.↗

Comparison of Data Quality of NOAA's ISIS and SURFRAD Networks to NREL's SRRL-BMS

This report provides analyses of broadband solar radiometric data quality for the National Oceanic and Atmospheric Administration's Integrated Surface Irradiance Study and Surface Radiation Budget Network (SURFRAD) solar measurement networks. The data quality of these networks is compared to that of the National Renewable Energy Laboratory's Solar Radiation Research Laboratory Baseline Measurement System (SRRL-BMS) native data resolutions and hourly averages of the data from the years 2002 through 2013. This report describes the solar radiometric data quality testing and flagging procedures and the method used to determine and tabulate data quality statistics. Monthly data quality statistics for each network were plotted by year against the statistics for the SRRL-BMS. Some of the plots are presented in the body of the report, but most are in the appendix. These plots indicate that the overall solar radiometric data quality of the SURFRAD network is superior to that of the Integrated Surface Irradiance Study network and can be comparable to SRRL-BMS.

14 SOLAR ENERGY↗

Non-conformity Scores for High-Quality Uncertainty Quantification from Conformal Prediction

High-quality uncertainty quantification (UQ) is a critical component of enabling trust in deep learning (DL) models and is especially important if DL models are to be deployed in high-consequence applications. Conformal prediction (CP) methods represent an emerging nonparametric approach for producing UQ that is easily interpretable and, under weak assumptions, provides a guarantee regarding UQ quality. This report describes the research outputs of an Exploratory Express Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. This project focused on how best to implement CP methods for DL models. This report introduces new methodology for obtaining high-quality UQ from DL models using CP methods, describes a novel system of assessing UQ quality, and provides experimental results that demonstrate the quality of the new methodology and utility of the UQ quality assessment system. Avenues for future research and discussion of potential impacts at Sandia and in the wider research community are also given.

97 MATHEMATICS AND COMPUTING↗

Co-benefits of global and regional greenhouse gas mitigation for US air quality in 2050

Policies to mitigate greenhouse gas (GHG) emissions will not only slow climate change but can also have ancillary benefits of improved air quality. Here we examine the co-benefits of both global and regional GHG mitigation for US air quality in 2050 at fine resolution, using dynamical downscaling methods, building on a previous global co-benefits study (West et al., 2013). The co-benefits for US air quality are quantified via two mechanisms: through reductions in co-emitted air pollutants from the same sources and by slowing climate change and its influence on air quality, following West et al. (2013). Additionally, we separate the total co-benefits into contributions from domestic GHG mitigation vs. mitigation in foreign countries. We use the Weather Research and Forecasting (WRF) model to dynamically downscale future global climate to the regional scale and the Sparse Matrix Operator Kernel Emissions (SMOKE) program to directly process global anthropogenic emissions to the regional domain, and we provide dynamical boundary conditions from global simulations to the regional Community Multi-scale Air Quality (CMAQ) model. The total co-benefits of global GHG mitigation from the RCP4.5 scenario compared with its reference are estimated to be higher in the eastern US (ranging from 0.6 to 1.0 µg m -3 ) than the west (0–0.4 µg m -3 ) for fine particulate matter (PM 2.5 ), with an average of 0.47 µg m -3 over the US; for O 3 , the total co-benefits are more uniform at 2–5 ppb, with a US average of 3.55 ppb. Comparing the two mechanisms of co-benefits, we find that reductions in co-emitted air pollutants have a much greater influence on both PM 2.5 (96 % of the total co-benefits) and O 3 (89 % of the total) than the second co-benefits mechanism via slowing climate change, consistent with West et al. (2013). GHG mitigation from foreign countries contributes more to the US O 3 reduction (76 % of the total) than that from domestic GHG mitigation only (24 %), highlighting the importance of global methane reductions and the intercontinental transport of air pollutants. For PM 2.5 , the benefits of domestic GHG control are greater (74 % of total). Since foreign contributions to co-benefits can be substantial, with foreign O 3 benefits much larger than those from domestic reductions, previous studies that focus on local or regional co-benefits may greatly underestimate the total co-benefits of global GHG reductions. We conclude that the US can gain significantly greater domestic air quality co-benefits by engaging with other nations to control GHGs.

54 ENVIRONMENTAL SCIENCES↗

Impacts of air pollutants from fire and non-fire emissions on the regional air quality in Southeast Asia

Severe haze events in Southeast Asia caused by particulate pollution have become more intense and frequent in recent years, degrading air quality, threatening human health, and interrupting economic and societal activities. Widespread biomass burning activities are a major source of severe haze events in Southeast Asia. On the other hand, particulate pollutants from human activities other than biomass burning also play an important role in degrading air quality in Southeast Asia. In this study, numerical simulations have been conducted using the Weather Research and Forecasting (WRF) model coupled with a chemistry component (WRF-Chem) to quantitatively examine the contributions of aerosols emitted from fire (i.e., biomass burning) versus non-fire (including fossil fuel combustion, road and industrial dust, land use, and land change, etc.) sources to the degradation of air quality and visibility over Southeast Asia. These simulations cover a time period from 2002 to 2008 and were respectively driven by emissions from: (a) fossil fuel burning only, (b) biomass burning only, and (c) both fossil fuel and biomass burning. Across ASEAN 50 cities, these model results reveal that 39&thinsp;% of observed low visibility days can be explained by either fossil fuel burning or biomass burning emissions alone, a further 20&thinsp;% by fossil fuel burning alone, a further 8&thinsp;% by biomass burning alone, and a further 5&thinsp;% by a combination of fossil fuel burning and biomass burning. The remaining 28&thinsp;% of observed low visibility days remain unexplained, likely due to emissions sources that have not been accounted for. Further analysis of 24-hr PM 2.5 Air Quality Index (AQI) indicates that comparing to the simulated result of the case with stand-alone non-fire emissions, the case with coexisting fire and non-fire PM 2.5 can substantially increase the chance of AQI being in the moderate or unhealthy pollution level from 23&thinsp;% to 34&thinsp;%. The premature mortality among major Southeast Asian cities due to degradation of air quality by particulate pollutants is estimated to increase from ~&thinsp;4110 per year in 2002 to ~&thinsp;6540 per year in 2008. In addition, we demonstrate the importance of certain missing non-fire anthropogenic aerosol sources including anthropogenic fugitive and industrial dusts in causing urban air quality degradation. An exploratory experiment of using machine learning algorithms to forecasting the occurrence of haze events in Singapore is also demonstrated in this study. All these results suggest that besides minimizing biomass burning activities, an effective air pollution mitigation policy for Southeast Asia needs to consider controlling emissions from non-fire anthropogenic sources.

Lee, Hsiang-He (ORCID:0000000251407324)↗

Flight evaluations of the effect of advanced control systems and displays on the handling qualities of a general aviation airplane.

Flight tests have shown that, by means of improved displays and advanced control systems, it is possible to transform a typical light airplane into a flying machine that borders on being perfect from a handling-qualities standpoint. A flight-director display and an attitude-command control system used in combination transformed a vehicle with poor handling qualities during ILS approaches in turbulent air into a vehicle with extremely good handling qualities. The attitude-command control system also improved the ride qualities of the airplane. A rate-command control system was less beneficial than an attitude-command control system. Although this paper deals primarily with general aviation aircraft, the results presented pertain to other types of aircraft. Short-takeoff-and-landing (STOL) aircraft would be a natural application of the control systems because, as a result of their low speeds, they encounter many of the handling-qualities problems noted on light aircraft. The improved ride qualities should be of interest to all airline operations, and for STOL aircraft in particular, because of their prolonged exposure to low-altitude turbulence.

Loschke, P. C.↗