Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection Challenges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Interfacial engineering of gallium indium phosphide photoelectrodes for hydrogen evolution with precious metal and non-precious metal based catalysts

Gallium indium phosphide (GaInP 2 ) is a semiconductor with promising optical and electronic properties to serve as the large bandgap, top junction in a dual absorber tandem solar water splitting device. Poor intrinsic catalytic ability and surface corrosion in aqueous electrolyte remain key obstacles. Significant progress has been made developing thin-film protection layers and active catalysts for photoelectrochemical devices, but combining these into a catalytic protection layer that can provide long-term stability without sacrificing performance has proven difficult due, in large part, to challenges in developing active and stable interfaces. In this work, we demonstrate that a nanoscale molybdenum disulfide (MoS 2 ) film functions both as an effective protection layer and excellent hydrogen evolution catalyst for GaInP 2 photocathodes, with only a ~10% loss in initial light-limited current density after 100 h, and a photocurrent onset potential better than that of the same state-of-the-art device with a platinum-ruthenium catalyst. Using transient photoreflectance spectroscopy, we probed the carrier dynamics of these photocathodes and show that the MoS 2 coated device exhibits improved electron transfer at the surface interface compared to the PtRu catalyzed device. These MoS 2 protected devices are among the most active and stable single-absorber photocathodes for solar water splitting to date and offer a promising pathway towards generating hydrogen with high efficiency and significant longevity.

08 HYDROGEN↗

Implementing Admittance Relaying for Microgrid Protection

An earlier study evaluated issues with microgrid protection. This highlighted the difficulties with microgrid protection, which include: 1. lack of fault current from inverter-interfaced generation, 2. varying fault current between grid-connected and islanded modes, 3. potential for normally-meshed operation and 4. unbalanced operation due to single-phase loads. It is worth noting that not all microgrid designs will include all these challenges. For example, microgrids could choose to omit meshed operation. Previous work identified differential protection based on the discrete S-transform for line protection and admittance protection for load protection as possible solutions . However, some severe limitations were identified. This included the potential for blinding of the discrete S-transform protection when fault contribution on either end of the line is similar, and loss of protection selectivity for admittance protection in the case of upstream line-ground faults. This report investigates admittance protection as a solution for line and load protection in greater detail by comparing analytical and simulated results. Section 2 describes the protection schemes analyzed and the behavior of inverter-interfaced microgrids under faults in more detail. Section 3 derives sequence networks for the fault cases considered. Section 4 presents a transient model constructed to validate the impedances calculated from the sequence networks. Section 5 compares the results from the sequence networks and transient model. Last, Section 6 presents the conclusions of this study in terms of the suitability of admittance relaying for protection of inverter-interfaced microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic State Estimation for Radial Microgrid Protection

Dynamic state estimation (DSE) is a generalization of differential protection that offers a reduced likelihood of misoperation, particularly in the case of devices with nonlinear characteristics such as transformers which are being energized. It is also useful in cases where distance protection performs poorly, such as transmission lines with series compensation or mutually coupled transmission lines. DSE has been previously applied to microgrid branch protection. This study investigates the use of DSE for protection of radial portions of a microgrid or distribution system. This can be a challenge in microgrids or distribution systems with distributed generation on account of lack of fault current from inverter-interfaced generation, varying fault current between grid- connected and islanded modes, the potential for normally-meshed operation and unbalanced operation due to single-phase loads. Admittance relaying has been investigated as a solution for protection of microgrids, though it has been observed to have issues with grounded-wye connected loads, and additional relaying is necessary to prevent misoperation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Study and Model Predictive Control of a Lean-Burn Gasoline Engine Coupled With a Passive Selective Catalytic Reduction System

Lean-burn gasoline engines have reflected 10–20% engine efficiency gain over stoichiometric engines and are widely considered as a promising technology for meeting the 54.5 miles-per-gallon (mpg) corporate average fuel economy standard by 2025. Nonetheless, nitrogen oxides (NO x ) emissions control for lean-burn gasoline for meeting the stringent Environmental Protection Agency tier 3 emission standards has been one of the main challenges toward the commercialization of highly efficient lean-burn gasoline engines in the United States. Passive selective catalytic reduction (SCR) systems, which consist of a three-way catalyst (TWC) and SCR, have demonstrated great potentials of effectively reducing NO x emissions for lean gasoline engines at low cost. Yet, passive SCR operation may cause significant fuel penalty since rich engine combustion is required for ammonia generation. The purpose of this study is to develop a model-predictive control (MPC) scheme for a lean-burn gasoline engine coupled with a passive SCR system to minimize the total equivalent fuel penalty associated with passive SCR operation while satisfying stringent NO x and ammonia (NH 3 ) emissions requirements. Simulation results demonstrate that the MPC approach can reduce the fuel penalty by 43.9% in a simulated US06 cycle and 28.0% in a simulated urban dynamometer driving schedule (UDDS) cycle, respectively, compared to the baseline control, while achieving over 97% DeNO x efficiency and less than 15 ppm tailpipe ammonia slip. The proposed MPC controller can potentially enable highly efficient lean-burn gasoline engines while meeting the stringent Environmental Protection Agency tier 3 emission standards.

33 ADVANCED PROPULSION SYSTEMS↗

In Situ MOF Pyrolysis Construction of Hierarchical Porous Co‐Nanoparticles/Carbon Cloth Composites for Enhanced Electromagnetic Wave Shielding and Absorption

The development of high-performance electromagnetic protection materials integrating broadband absorption and effective shielding capabilities is hindered by challenges in simultaneously optimizing multiple electromagnetic properties through conventional material designs. This study pioneers a hierarchical porous Co nanoparticle/carbon cloth (Co/CC) composite via controlled annealing of a Co-MOF precursor on carbon cloth. The Co-MOF served a dual role as both magnetic source and pore-forming agent, enabling in situ generation of uniformly dispersed Co nanoparticles and creation of abundant pores/interfaces on the CC fibers during pyrolysis. This unique architecture synergistically enhanced dielectric loss (via interfacial/dipolar polarization) and magnetic loss (via natural resonance, exchange interactions, and eddy currents), significantly improving impedance matching. The hierarchical pores further functioned as integrated “absorption–reflection” units for efficient electromagnetic energy attenuation. Consequently, the Co/CC composite annealed at 800°C (Co/CC-800) achieves minimum reflection loss (−40.69 dB) and 120% effective absorption bandwidth extension (6.16 GHz) as a filler, and exhibits superior electromagnetic interference shielding effectiveness (46.66 dB) as an integrated component. Significantly, Co/CC-800 demonstrated robust photothermal and electrothermal conversion capabilities, ensuring operational stability in ice-covered and humid harsh environments. This work pioneers a pore-structure-mediated strategy to harmonize dielectric–magnetic synergy, providing a new paradigm for designing advanced multifunctional electromagnetic protection materials.

dielectric‐magnetic synergy↗

Decommissioning of obsolete Nuclear Facilities in the UJV Rez, a. s. - 19027

UJV Rez, a. s. (further also UJV) is a leading institution in all areas of nuclear R and D in the Czech Republic and has had a dominant position in the nuclear program since it was established in 1955 as the Nuclear Research Institute Rez. The activities of UJV encompass nuclear physics, chemistry, nuclear power and many other topics. The main issues addressed at UJV in past decades have included research, development and services for NPPs, the fuel cycle and irradiation services for research and development in the industrial sector and medicine. UJV also manages most institutional radioactive wastes (RAW) produced in the Czech Republic (approx. 90 %). After more than 60 years of activities of the UJV in the nuclear field, there were obsolete nuclear facilities to be decommissioned. Decommissioning of nuclear facilities UJV is the only ongoing decommissioning project in the Czech Republic. Preparations for decommissioning began in 1996. Safety analysis report (SAR) was performed comprising the identification and characterization of potential sources of risk, potentially exposed receptors and exposure pathways, potential chemical compounds, radionuclides and media of concern. The results of the SAR enabled to determine the priorities of the decommissioning, the decommissioning the expenses and as well as project implementation. The decommissioning project was revised on the base of information obtained during decommissioning. The decommissioning was divided into two phases according to the level of risk and the financing limitations. The Ministry of Finance significantly financially contributed the decommissioning, although the UJV also contributed a considerable amount. Overall cost is close to the amount of Eur 27 million. Decommissioning started in 2003 and will be finished in 2018. Almost all facilities have already been successfully decommissioned. In the following table, the status of decommissioning of facilities is described. 1) Reloading site for RAW storage (Building 211/6): last item in progress 2003 - 2018; 2) Special Sewage System: decommissioned 2004 - 2005, reused; 3) Liquid RAW storage tanks (Building 211/3): decontaminated 2004 - 2013, reused; 4) Technology for RAW treatment (Building 241): decommissioned 2003 - 2011; 5) Contaminated equipment (Building 250): decommissioned 2003 - 2016; 6) Systems for storage of sealed sources (Building 261); decommissioned 2003 - 2005; 7) Decay tanks (Building 211/5); decommissioned 2003 - 2014, reused; 8) Old bituminating unit (Building 211/3); decommissioned 2004 - 2008; 9) Surface RAW storage site; decommissioned 2009 - 2014. Later, other unused decommissioning facilities, which were not included in the decommissioning project financed by the state, were included. These facilities are continuously decommissioned and financed from own resources of UJV. These facilities are like facilities already decommissioned: radiochemical laboratories, (including glove boxes), liquid RW storage tanks (including sewage systems), liquid RW treatment technology, hot cells, accumulated RW, etc. Realization started 2016 and expected duration is till 2026. Estimated budget is approximately Eur 17 million. The decommissioning of nuclear facilities in UJV is being carried out on the high level of radiation protection and up to now there was no extraordinary event or accident, although some challenges we were forced to address. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Reactor Safeguards Program Roadmap

The Advanced Reactor Safeguards (ARS) program was established in 2020 as part of appropriations for the Advanced Reactor Demonstration Program (ARDP) through the Office of Nuclear Energy in the Department of Energy. The goal of this program is to help address near term challenges that advanced nuclear reactor vendors face in meeting domestic Material Control and Accountancy (MC&A) and Physical Protection System (PPS) requirements for U.S. construction. Existing regulations for safeguards and security, as outlined in the Code of Federal Regulations, were written for large light water reactors, and some of the requirements are not suited to smaller, safer advanced reactor designs. The ARS program seeks to remove roadblocks in the deployment of new and advanced reactors by solving regulatory challenges, reducing safeguards and security costs, and utilizing the latest technologies and approaches for robust plant monitoring and protection. Safeguards and Security by Design (SSBD), or the consideration of safeguards and security requirements early in the design process, is an overarching principle that guides this program. This roadmap discusses the goals of the ARS program, current research, and program plan for the next five years.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

A Theoretical Analysis: Physical Unclonable Functions and The Software Protection Problem

Physical Unclonable Functions (PUFs) or Physical One Way Functions (P-OWFs) are physical systems whose responses to input stimuli (i.e., challenges) are easy to measure (within reasonable error bounds) but hard to clone. This property of unclonability is due to the accepted hardness of replicating the multitude of uncontrollable manufacturing characteristics and makes PUFs useful in solving problems such as device authentication, software protection, licensing, and certified execution. In this paper, we focus on the effectiveness of PUFs for software protection and show that traditional non-computational (black-box) PUFs cannot solve the problem against real world adversaries in offline settings. Our contributions are the following: We provide two real world adversary models (weak and strong variants) and present definitions for security against the adversaries. We continue by proposing schemes secure against the weak adversary and show that no scheme is secure against a strong adversary without the use of trusted hardware. Finally, we present a protection scheme secure against strong adversaries based on trusted hardware.

97 MATHEMATICS AND COMPUTING↗

Challenges to Evaluating Ecological Risks in Performance Assessments - 18424

Performance assessments (PAs), whether probabilistic or deterministic, have largely focused on evaluating human health effects of radionuclides. In the past, it was asserted that protecting human health would automatically protect the environment. This blanket assertion has been questioned, so tools and methodologies to directly estimate non-human biota dose have been developed and made available since the early 2000's. For example, the Biota Dose Assessment Committee (BDAC) guidance led to the development of the RESRAD-BIOTA (RESRAD stands for Residual Radioactive materials) software to implement this guidance. The BDAC was a US Department of Energy (DOE) led working group with members from academia and consultancies in addition to DOE technical staff. Parallel efforts have been in place in Europe with the development of the ERICA tool (Environmental Risk from Ionising Contaminants: Assessment and Management). More recently, interpretation of the requirements of US Department of Energy (DOE) Order O458.1 have led some waste management facilities to include ecological risks in addition to human health effects in their PAs. We have recently developed methodologies to assess ecological risks within probabilistic PAs (PPAs) for two Federal facilities. One of the challenges in applying the non-human biota assessment models to PPAs is that ecological risk assessments following US Environmental Protection Agency (EPA) or DOE guidance start with protective screening assessments before moving into more site-specific ecological risk assessments. Conservative assumptions bias the screening assessments and greatly overestimate the risks posed by contaminants. However, although the screens are biased they can be useful in ruling out model spatial domain areas or types of biota from requiring further assessment. In some cases, the results of the screen could entirely rule out ecological risks from further assessment. For a more refined and unbiased estimate of dose to non-human biota, one would typically conduct site-specific studies to better define exposure through the food web or adverse effects based on eco-toxicity studies of environmental, and generally weathered, contaminant mixtures. However, for PPAs that consider future site conditions after the loss of institutional control, such site-specific studies are not possible. Rather, site-specific future ecological risk models use probabilistic inputs that result in a distribution of population doses or exposures and calculate the distribution of possible adverse effects to ecological populations. This approach considers both radionuclide and chemical inventory. For both Federal facilities, the model spatial domains include riparian and aquatic environments located downstream of the waste management site. These riparian and aquatic environments represent linear exposure elements for some wildlife populations and require special consideration of exposures to individuals and to populations along such spatial domains. At a minimum, wildlife foraging should be focused along the axis of such water bodies. Another challenge is how to incorporate ecologically relevant spatial scales into models that have contaminant transport as the primary focus. Riparian and aquatic environments also have threatened and endangered (T and E) species, which necessitate greater levels of protection given their rarity. A final challenge for conducting ecological risk assessments is how to evaluate T and E species in the future. This might be addressed by evaluating potential for impacts on individuals of feeding guilds with species that are currently threatened or endangered. We also have to consider how ecological populations might change as a result of climate change. It is a more difficult problem to predict what species might become rare in the future, and how to best assess future populations of threatened or endangered species. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize the R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.

97 MATHEMATICS AND COMPUTING↗

The efficacy of post porosity plasma protection against vacuum-ultraviolet damage in porous low-k materials

As of today, plasma damage remains as one of the main challenges to the reliable integration of porous low-k materials into microelectronic devices at the most aggressive node. One promising strategy to limit damage of porous low-k materials during plasma processing is an approach we refer to as post porosity plasma protection (P4). In this approach, the pores of the low-k material are filled with a sacrificial agent prior to any plasma treatment, greatly minimizing the total damage by limiting the physical interactions between plasma species and the low-k material. Interestingly, the contribution of the individual plasma species to the total plasma damage is not fully understood. In this study, we investigated the specific damaging effect of vacuum-ultraviolet (v-UV) photons on a highly porous, k = 2.0 low-k material and we assessed the P4 protective effect against them. It was found that the impact of the v-UV radiation varied depending upon the v-UV emission lines of the plasma. More importantly, we successfully demonstrated that the P4 process provides excellent protection against v-UV damage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The theory behind, and the challenges of, conserving nature's stage in a time of rapid change

Most conservation planning to date has focused on protecting today's biodiversity with the assumption that it will be tomorrow's biodiversity. However, modern climate change has already resulted in distributional shifts of some species and is projected to result in many more shifts in the coming decades. As species redistribute and biotic communities reorganize, conservation plans based on current patterns of biodiversity may fail to adequately protect species in the future. One approach for addressing this issue is to focus on conserving a range of abiotic conditions in the conservation-planning process. By doing so, it may be possible to conserve an abiotically diverse "stage" upon which evolution will play out and support many actors (biodiversity). We reviewed the fundamental underpinnings of the concept of conserving the abiotic stage, starting with the early observations of von Humboldt, who mapped the concordance of abiotic conditions and vegetation, and progressing to the concept of the ecological niche. We discuss challenges posed by issues of spatial and temporal scale, the role of biotic drivers of species distributions, and latitudinal and topographic variation in relationships between climate and landform. For example, abiotic conditions are not static, but change through time-albeit at different and often relatively slow rates. In some places, biotic interactions play a substantial role in structuring patterns of biodiversity, meaning that patterns of biodiversity may be less tightly linked to the abiotic stage. Furthermore, abiotic drivers of biodiversity can change with latitude and topographic position, meaning that the abiotic stage may need to be defined differently in different places. Lastly, we conclude that protecting a diversity of abiotic conditions will likely best conserve biodiversity into the future in places where abiotic drivers of species distributions are strong relative to biotic drivers, where the diversity of abiotic settings will be conserved through time, and where connectivity allows for movement among areas providing different abiotic conditions.

54 ENVIRONMENTAL SCIENCES↗

Highly Selective Methane to Methanol Conversion on Inverse SnO 2 /Cu 2 O/Cu(111) Catalysts: Unique Properties of SnO 2 Nanostructures and the Inhibition of the Direct Oxidative Combustion of Methane

Direct methane to methanol (CH 4 → CH 3 OH) conversion in heterogeneous catalysis has been a long-standing challenge due to the difficulties in equalizing the activation of methane and protection of the methanol product at the same reaction conditions. Here, we report an inverse catalyst, consisting of small structures of SnO 2 (0.5-1 nm in size) dispersed on Cu 2 O/Cu(111), for highly selective CH 3 OH production from CH 4 . This system was investigated by combining theoretical [density functional theory calculations (DFT), kinetic Monte Carlo simulations (KMC)] and experimental methods [scanning tunneling microscopy (STM), ambient-pressure X-ray photoelectron spectroscopy (AP-XPS)]. The DFT and AP-XPS studies showed that on SnO 2 /Cu 2 O/Cu(111) the conversion of CH 4 by oxygen (O 2 ) preferred complete combustion to carbon dioxide (CO 2 ). The addition of water (H 2 O) enhanced the production of CH 3 OH to nearly 100% selectivity in KMC simulations. This trend was consistent with results of AP-XPS. The presence of water in the reaction environment rendered an extremely high amount of methoxy species (*CH 3 O), a precursor for CH 3 OH production. Further, the high CH 3 OH selectivity of SnO 2 /Cu 2 O/Cu(111) reflected the unique atomic and electronic structure of the supported SnO 2 nanoparticles. As a result, the O 2 adsorption and dissociation, and thus the full combustion of CH 4 to CO 2 , was completely suppressed; while the H 2 O dissociative adsorption was still feasible, providing active hydroxyl species for a truly selective CH 4 to CH 3 OH conversion.

03 NATURAL GAS↗

Photoexcitation of bulk polarons in rutile TiO 2

The excitation of surface-localized polaronic states has recently been discussed as an additional photocatalytic channel to band gap excitation for rutile TiO 2 . A contribution from photoexcitation of bulk polarons could, in principle, provide a greater contribution because of their higher number and their protection from oxidation. However, determining such a contribution to the photoyield is challenging and has not been achieved thus far. In this work, we use two photon photoemission spectroscopy measurements to separate bulk and surface polaron photoexcitation. We find that bulk polarons are less bound by 0.2 eV compared with polarons at the surface, consistent with our results of hybrid density functional theory calculations. Because the excited state is also shifted to higher energy, bulk polarons have the same photoexcitation resonance energy as at the surface (3.6 eV) with a threshold at 3.1 eV. This is degenerate with the band gap, suggesting that bulk polarons could also provide an additional contribution to the photoyield.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data Security Defense: Modeling and Detection of Synchrophasor Data Spoofing Attack for Grid Edge

Data security and cyberattack have become critical issues in the distributed power system where adversaries can swap the source information of sensors or even spoof and alter measurements. However, the cyber security of the power system is challenged by the unpredictability and stealth of the spoofing attacks. Here, to protect the data security at the grid edge, this paper developed a synchrophasor data spoofing attack detection framework based on the time-frequency feature extraction techniques including the short-time Fourier transform (STFT) and object detection network for real-time synchrophasor data categorization and spoofing attack localization. The proposed approach outperforms earlier work in terms of spoofing attack detection and offers a vital localization function employing distributed synchrophasor sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating AEAD Ciphers into Software-Defined-Storage Systems

The use of software-defined storage (SDS) systems to store sensitive data is becoming increasingly prevalent. However, these systems primarily implement security measures to ensure the confidentiality and availability of stored data, with limited consideration for the protection of its integrity. This paper outlines why this is a harmful development, as well as how integrity-protecting measures can be included into SDS systems. To demonstrate the practical challenges and opportunities of such measures, we integrated "authenticated encryption with associated data" (AEAD) ciphers into the widely used SDS system Ceph, specifically, into its block storage interface, to secure the integrity of stored data and metadata. Ultimately, we identify the characteristics that an SDS system should possess to adopt our methodology.

Mohren, David [University of New Brunswick, Canada↗

Roll-to-roll atomic layer deposition process for flexible electronics encapsulation applications

At present flexible electronic devices are under extensive development and, among them, flexible organic light-emitting diode displays are the closest to a large market deployment. One of the remaining unsolved challenges is high throughput production of impermeable flexible transparent barrier layers that protect sensitive light-emitting materials against ambient moisture. The present studies deal with the adaptation of the atomic layer deposition (ALD) process to high-throughput roll-to-roll production using the spatial ALD concept. We report the development of such a process for the deposition of 20 nm thickness Al{sub 2}O{sub 3} diffusion barrier layers on 500 mm wide polymer webs. The process uses trimethylaluminum and water as precursors at a substrate temperature of 105 °C. The observation of self-limiting film growth behavior and uniformity of thickness confirms the ALD growth mechanism. Water vapor transmission rates for 20 nm Al{sub 2}O{sub 3} films deposited on polyethylene naphthalate (PEN) substrates were measured as a function of substrate residence time, that is, time of exposure of the substrate to one precursor zone. Moisture permeation levels measured at 38 °C/90% relative humidity by coulometric isostatic–isobaric method were below the detection limit of the instrument (<5 × 10{sup −4} g/m{sup 2} day) for films coated at web moving speed of 0.25 m/min. Measurements using the Ca test indicated water vapor transmission rates ∼5 × 10{sup −6} g/m{sup 2} day. Optical measurements on the coated web showed minimum transmission of 80% in the visible range that is the same as the original PEN substrate.

36 MATERIALS SCIENCE↗