Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Radio and X-ray observations of the radio halo source in A1367

Radio and X-ray observations of the 'radio halo' in A1367 are presented. The radio spectral index distribution is derived combining data at 610 and 1415 MHz taken with the Westerbork Synthesis Radio Telescope (WSRT). A high-resolution Very Large Array (VLA) map allows us to discriminate between the extended cluster emission and a triple radio source associated with a background stellar object (most probably a QSO) which appears projected onto it. X-ray observations taken with the high-resolution imager on board the Einstein satellite reveal an X-ray source associated with this background object. A second weak X-ray enhancement is found projected onto the extended radio component. Inverse Compton scattering of the synchrotron-emitting particles provides a possible interpretation of such a source. The presence of large-scale magnetic fields and particle acceleration due to the turbulent motion of galaxies through the intergalactic medium is discussed in relationship to the observed peculiarities of the galaxies found in this region.

Gavazzi, G.↗

Constellation X-Ray Mission and Support

This Fourth Annual Report summarizes work performed by the Smithsonian Astrophysical Observatory (SAO) for NASA Goddard Space Flight Center (GSFC) under Cooperative Agreement NCC5-368. The Agreement is entitled Constellation X-ray Mission Study and SAO continues to perform work under the overall direction of Dr. Harvey Tananbaum, the SAO Principal Investigator for the program. Mr. Robert Rasche is the SAO Program Manager and is responsible for day-to-day program management at SAO and coordination with GSFC. The report summarizes the main areas of SAO activity. Most of the work has been done jointly with personnel from GSFC and Marshall Space Flight Center (MSFC). We describe SAO participation in these efforts. As is appropriate to a Cooperative Agreement, SAO continued to work with GSFC in an integrated team mode. SAO was involved in the overall mission management, technology development, scientific direction, and mission definition. While formal overall management responsibility resides with GSFC, scientific lead and subordinate responsibilities continue to be shared by GSFC and SAO. The work performed by SAO is consistent with the SAO proposal 'Constellation X-ray Mission Study and Optics Development' dated September 1997, which was the basis for establishing the Cooperative Agreement under which SAO is currently funded. Over time, the scope of the effort has expanded somewhat to accommodate the needs of the project. Work, except for meeting support and high priority program tasks, has been at a level of effort. Priorities and work progress have been closely coordinated with the Constellation-X Project Formulation Manager at GSFC. Funding limitations constrained the work accomplished during this period. Nonetheless, a significant amount of work was accomplished. Under the Agreement, SAO performed work in seven major areas of activity. These areas related to: Constellation X-ray Mission Facility Definition Team and Study Management; Science Support; Spectroscopy X-ray Telescope (SXT); Systems Engineering; Travel in Support of the Work Effort; In-house Management and Coordination.

Grady, Jean↗

Transition dynamics for Mu acceptor states in Si{sub 1–x}Ge{sub x} alloys

We use the longitudinal field muon spin relaxation technique to observe charge-state and site-change transitions of muonium in Si{sub 1–x}Ge{sub x} alloys. In this project, we examine the temperature and magnetic field dependences of the relaxation rates for Si{sub 1–x}Ge{sub x} samples (x = 0.77, 0.81, and 0.84), in the composition range where the acceptor level lies within the band gap. This study particularly focuses on the relaxation rates for Si{sub 0.19}Ge{sub 0.81} to identify various cyclic charge-state and site-change processes as a function of both temperature and magnetic field. We extract the paramagnetic hyperfine constant and the relevant transition rate parameters for site changes and charge-state transitions involving Mu acceptor states for this sample. At small x, a site change dominates the transition out of the neutral T-site acceptor state, while in higher Ge content alloys hole ionization becomes the dominant transition out of the Mu{sub T}{sup 0}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical thermonuclear reactions in classical novae and type I X-ray bursts

The goal of this project was to experimentally constrain the nuclear reaction rates whose uncertainties have the largest impact on models of classical novae and Type-I X-ray bursts. These astrophysical events occur when a white dwarf or neutron star, respectively, accretes hydrogen and helium from a companion star until a thermonuclear runaway ensues. The primary reactions of interest to this project for novae and X-ray bursts are 30 P(ρ,γ) 31 S and 15 O(α,γ) 19 Ne. The project methodology was to develop a new radiation detection system in two phases to measure the low-energy beta-delayed particle emissions of 31 Cl and 20 Mg at the National Superconducting Cyclotron Laboratory (NSCL) in order to constrain these two reaction rates. In particular, a gas-filled charged-particle detector was to be designed, constructed and operated, in concert with the SeGA array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Report: Nanoscale Dynamical Heterogeneity in Complex Magnetic Materials

A magnetic object can be demagnetized by dropping it on a hard surface, but what does ‘demagnetized’ actually mean? In 1919 Heinrich Barkhausen proved the existence of magnetic domains, which are regions of uniform magnetization that are much larger than atoms but much smaller than a macroscopic object. A material is fully magnetized when domain magnetizations are aligned, while it is demagnetized when the domain magnetizations are randomly oriented and the net magnetization is zero. The heterogeneity of a demagnetized object leads to interesting questions. Magnets are unstable when their poles align, and stable when their poles anti-align, so why is the magnetized state ever stable? What do domains look like? What is the structure of a domain wall? How does the magnetized state transform to the demagnetized state? How do domains appear and disappear? What are the statistical properties of domains and how do these vary as the domain pattern evolves? Some of these questions remain the focus of intense study nearly a century after Barkhausen’s discovery. For example, just a few years ago a new kind of magnetic texture called a skyrmion was discovered. A skyrmion is a magnetic domain that is a nanometer-scale, topologically protected vortex. ‘Topologically protected’ means that skyrmions are hard to destroy and so are stable for extended periods. Skyrmions are characterized by integral quantum numbers and are observed to move with little dissipation and so could store and process information with very low power input. Our research project uses soft x-rays, which offer very high magnetic contrast, to probe magnetic heterogeneity and to measure how it evolves in time under external influences. We will condition a soft x-ray beam so that the wave fronts will be coherent, that is, they will be smooth and well-defined. When coherent soft x-ray beam interacts with a magnetic material, the magnetic heterogeneity is imprinted onto the wave fronts and projected into a diffraction pattern. These patterns will be analyzed to understand the structure, motion, and statistical properties of magnetic textures and their boundaries. Over the period covered by this grant we will study a) the structure, phase behaviors, and motion of skyrmions in various thin film materials, and 2) the statistical properties of Barkhausen cascades, which are a key factor in how magnetization varies.

36 MATERIALS SCIENCE↗

Spectroscopy of Low Mass X-Ray Binaries: New Insights into Accretion

This project is to observe two low mass X-ray binaries, chosen for their X-ray brightness, low column density, and diversity of accretion behavior. The high spectral resolution of the RGS, the broad energy range and tremendous collecting power of EPIC, and simultaneous optical monitoring with the OM are particularly well-suited to these studies. observation of one of the two objects has taken place and the data were received in late November. The second object is yet to be observed. Over the next year we will: investigate the physical conditions of the emitting gas using emission and recombination line diagnostics to determine temperatures, densities, elemental abundances, and ionization structure; study the behavior of emission features as a function of binary orbit; and test and improve models of X-ray line emission developed by us over the past decade. We will gain insight on both the geometry of the accretion flow and on the evolutionary history of LMXBs.

DilVrtilek, Saeqa↗

Spectroscopy of Low Mass X-Ray Binaries: New Insights into Accretion

This project is to observe two low mass X-ray binaries, chosen for their X-ray brightness, low column density, and diversity of accretion behavior. The high spectral resolution of the RGS, the broad energy range and tremendous collecting power of EPIC, and simultaneous optical monitoring with the OM are particularly well-suited to these studies. The second of two objects was not observed until September of 2002. Data analysis for the new observation is underway. over the next year we will: investigate the physical conditions of the emitting gas using emission and recombination line diagnostics to determine temperatures, densities, elemental abundances, and ionization structure; study the behavior of emission features as a function of binary orbit; and test and improve models of X-ray line emission developed by us over the past decade. We will gain insight on both the geometry of the accretion flow and on the evolutionary history of LMXBs.

Vrtilek, Saeqa Dil↗

Spectroscopy of Low Mass X-Ray Binaries: New Insights into Accretion

This project is to observe two low mass X-ray binaries, chosen for their X-ray brightness, low column density, and diversity of accretion behavior. The high spectral resolution of the RGS, the broad energy range and tremendous collecting power of EPIC, and simultaneous optical monitoring with the OM are particularly well-suited to these studies. The second of two objects was observed on September of 2002. Data analysis for both observation has been completed: an investigation of the physical conditions of the emitting gas using emission and recombination line diagnostics to determine temperatures, densities, elemental abundances, and ionization structure. A study of behavior of the emission features as a function of binary orbit shows modulated behavior in one of the systems. A paper on "High-resolution observations of low-mass X-ray binaries" is near completion. The paper includes observations with the Chandra HETG that are not yet completed.

DilVrtilek, Saeqa↗

X-Ray Oscillations in AM Herculis Binaries

Presents a final analysis of a research project at the Space Telescope Science Institute with funding from NASA. The project used the Rossi X-Ray Timing Explorer (RXTE) to detect both high (1-3 s) and low (approx. 600 s) frequency quasi-periodic oscillations (QPOs) from 6 AM Herculis binaries. Simultaneous optical observations of QPOs were used in making sensitive analyses of these QPOs. Observations of 6 binaries enabled a test of the relationship of frequency and magnetic field strength for the high frequency QPOs and observations of binaries of different orbital periods enabled the distinction between the two competing models of low frequency oscillations.

Barrett, Paul↗

Ares I-X Flight Data Evaluation: Executive Overview

NASA's Constellation Program (CxP) successfully launched the Ares I-X flight test vehicle on October 28, 2009. The Ares I-X flight was a developmental flight test to demonstrate that this very large, long, and slender vehicle could be controlled successfully. The flight offered a unique opportunity for early engineering data to influence the design and development of the Ares I crew launch vehicle. As the primary customer for flight data from the Ares I-X mission, the Ares Projects Office (APO) established a set of 33 flight evaluation tasks to correlate flight results with prospective design assumptions and models. The flight evaluation tasks used Ares I-X data to partially validate tools and methodologies in technical disciplines that will ultimately influence the design and development of Ares I and future launch vehicles. Included within these tasks were direct comparisons of flight data with preflight predictions and post-flight assessments utilizing models and processes being applied to design and develop Ares I. The benefits of early development flight testing were made evident by results from these flight evaluation tasks. This overview provides summary information from assessment of the Ares I-X flight test data and represents a small subset of the detailed technical results. The Ares Projects Office published a 1,600-plus-page detailed technical report that documents the full set of results. This detailed report is subject to the International Traffic in Arms Regulations (ITAR) and is available in the Ares Projects Office archives files.

Huebner, Lawrence D.↗

Adjustable Grazing-Incidence X-Ray Optics

With its unique subarcsecond imaging performance, NASA's Chandra X-ray Observatory illustrates the importance of fine angular resolution for x-ray astronomy. Indeed, the future of x-ray astronomy relies upon x-ray telescopes with comparable angular resolution but larger aperture areas. Combined with the special requirements of nested grazing-incidence optics, mass, and envelope constraints of space-borne telescopes render such advances technologically and programmatically challenging. The goal of this technology research is to enable the cost-effective fabrication of large-area, lightweight grazing-incidence x-ray optics with subarcsecond resolution. Toward this end, the project is developing active x-ray optics using slumped-glass mirrors with thin-film piezoelectric arrays for correction of intrinsic or mount-induced distortions.

O'Dell, Stephen L.↗

Characterizing the modulation transfer function for X-ray radiography in high energy density experiments

Here, the Modulation Transfer Function ( MTF ) is an established means for characterizing imaging performance of X-ray radiography systems. We report on experiments using high energy, laser-driven X-ray radiography systems that assess performance using MTF values measured with the knife-edge projection method. The broadband, hard X-ray systems under study use line-projection imaging produced by narrowing the laser-generated X-ray source with a slit. We find that good contrast resolution can be achieved (the MTF = 0.5 at 75 μm wavelength) and that this performance is reproduced on different laser facilities. We also find that the MTF is sensitive both to the thickness of the line-projection slit and to the backing material thickness under the knife-edge. Both these sensitivities are due to a common mechanism, namely induced changes in the spectrally-averaged spatial widths of the X-ray source. The same line-projection system is also used on experimental campaigns measuring Rayleigh-Taylor instability growth by dynamically imaging sinusoidal, high Z micro-targets with wavelengths of 100 μm or less. By applying the measured MTF values to correct the ripple target contrast measurements, we can predict ripple growth to approximately 10% accuracy.

47 OTHER INSTRUMENTATION↗

X-33 Environmental Impact Statement: A Fast Track Approach

NASA is required by the National Environmental Policy Act (NEPA) to prepare an appropriate level environmental analysis for its major projects. Development of the X-33 Technology Demonstrator and its associated flight test program required an environmental impact statement (EIS) under the NEPA. The EIS process is consists of four parts: the "Notice of Intent" to prepare an EIS and scoping; the draft EIS which is distributed for review and comment; the final ETS; and the "Record of Decision." Completion of this process normally takes from 2 - 3 years, depending on the complexity of the proposed action. Many of the agency's newest fast track, technology demonstration programs require NEPA documentation, but cannot sustain the lengthy time requirement between program concept development to implementation. Marshall Space Flight Center, in cooperation with Kennedy Space Center, accomplished the NEPA process for the X-33 Program in 13 months from Notice of Intent to Record of Decision. In addition, the environmental team implemented an extensive public involvement process, conducting a total of 23 public meetings for scoping and draft EIS comment along with numerous informal meetings with public officials, civic organizations, and Native American Indians. This paper will discuss the fast track approach used to successfully accomplish the NEPA process for X-33 on time.

McCaleb, Rebecca C.↗

Search for x ray emitting young stars outside of massive molecular clouds

This project is intended to determine whether X-ray surveys of the sky can uncover previously unrecognized populations of pre-main sequence stars outside of large well-known star forming regions. X-ray observations of large regions such as the Taurus-Auriga complex, Orion molecular cloud, Ophiuchi and Chamaeleon clouds had revealed that low mass pre-main sequence emit X-rays 10(exp 2)-10(exp 4) above main sequence levels, and that X-ray surveys select a large population of 'weak' T Tauri stars that are not easily found in traditional optical and infrared surveys. The present project sought to find 'weak' T Tauri stars around smaller and more distant molecular clouds. X-ray surveys potentially could elucidate the star forming capabilities of small clouds, which are not well understood.

Feigelson, Eric D.↗

Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Iron Project

Recent advances in theoretical atomic physics have enabled large-scale calculation of atomic parameters for a variety of atomic processes with high degree of precision. The development and application of these methods is the aim of the Iron Project. At present the primary focus is on collisional processes for all ions of iron, Fe I - FeXXVI, and other iron-peak elements; new work on radiative processes has also been initiated. Varied applications of the Iron Project work to X-ray astronomy are discussed, and more general applications to other spectral ranges are pointed out. The IP work forms the basis for more specialized projects such as the RmaX Project, and the work on photoionization/recombination, and aims to provide a comprehensive and self-consistent set of accurate collisional and radiative cross sections, and transition probabilities, within the framework of relativistic close coupling formulation using the Breit-Pauli R-Matrix method. An illustrative example is presented of how the IP data may be utilized in the formation of X-ray spectra of the K alpha complex at 6.7 keV from He-like Fe XXV.

Pradhan, Anil K.↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗