Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A volatile organics concentrator for use in monitoring Space Station water quality

The process used to identify, select, and design an approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment is discerned. The trade analysis leading to the recommended volatile organics concentrator (VOC) concept to be tested in a breadboard device is presented. The system covers the areas of gases, volatile separation from water, and water removal/gas chromatograph/mass spectrometer interface. Five options for potential use in the VOC and GC/MS system are identified and ranked, and also nine options are presented for separation of volatiles from the water phase. Seven options for use in the water removal/GC column and MS interface are also identified and included in the overall considerations. A final overall recommendation for breadboard VOC testing is given.

Ehntholt, Daniel J.↗

Compositional analysis of projectile residues on LDEF instrument AO187-1

Impact craters greater than 30 microns and associated projectile residues were analyzed by Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Analysis (EDXA). Objectives were to analyze a statistically significant number of projectiles to evaluate their chemical variability and possible clustering into discrete particle types. Bay A11 exposed six collector surfaces of anodized 1100-T4 (greater than 99 percent pure) aluminum sheets, 0.32 cm thick, yielding an exposed surface area of 1.1 sq. m. Four of the six panels have been retained at JSC, and were optically scanned, one (A11E00E) was prepared for SEM/EDX analysis. Bay A03 was occupied by high purity (99.99 percent) gold sheets, 0.5 mm thick, yielding an exposed surface area of 0.85 sq. m. Sample processing included the optical scanning (6X), labeling, and dislodging (by a punch-die device) of each individual impact greater than 75 microns for the aluminum and 30 microns for the gold. The 209 craters were dislodged form A11E00E, having crater diameters up to 3500 microns. Optical examination of the gold surfaces detected 238 craters, 198 of which were retained at JSC and analyzed via SEM/EDX. The analytical procedures included maximizing the geometric efficiency (take-off angles), using relatively long count times (500-1000 sec) and sufficiently high accelerating currents (25-30Kev). Despite diligent examination, a large number of craters did not exhibit measurable signals above background. Detectable resides were classified as either micrometeoritic or as man-made debris.

Bernhard, Ronald P.↗

Fixture For Sampling Volatile Materials In Containers

Fixture based on T-connector enables mass-spectrometric analysis of volatile contents of cylindrical containers without exposing contents to ambient conditions. Used to sample volatile contents of pressurized containers, contents of such enclosed processing systems as gas-phase reactors, gases in automotive emission systems, and gas in hostile environments.

Melton, Donald↗

BOREAS TE-5 Diurnal CO2 Canopy Profile Data

The BOREAS TE-5 team collected several data sets to investigate the vegetation-atmosphere CO2 and H2O exchange processes. These data were collected to provide detailed information within the canopy during times when TE-05 sampled canopy CO2 for carbon and oxygen isotope analysis. These measurements were made in both the NSA and SSA at the OJP, OBS, UBS, and OA sites from 25-May1994 to 08-Sep1994. CO2 profile data were not collected at SSA-OA during the first IFC. The data are available in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

Hall, Forrest G.↗

Insight into Primordial Solar System Oxygen Reservoirs from Returned Cometary Samples

The recent successful rendezvous of the Stardust spacecraft with comet Wild-2 will be followed by its return of cometary dust to Earth in January 2006. Results from two separate dust impact detectors suggest that the spacecraft collected approximately the nominal fluence of at least 1,000 particles larger than 15 micrometers in size. While constituting only about one microgram total, these samples will be sufficient to answer many outstanding questions about the nature of cometary materials. More than two decades of laboratory studies of stratospherically collected interplanetary dust particles (IDPs) of similar size have established the necessary microparticle handling and analytical techniques necessary to study them. It is likely that some IDPs are in fact derived from comets, although complex orbital histories of individual particles have made these assignments difficult to prove. Analysis of bona fide cometary samples will be essential for answering some fundamental outstanding questions in cosmochemistry, such as (1) the proportion of interstellar and processed materials that comprise comets and (2) whether the Solar System had a O-16-rich reservoir. Abundant silicate stardust grains have recently been discovered in anhydrous IDPs, in far greater abundances (200 5,500 ppm) than those in meteorites (25 ppm). Insight into the more subtle O isotopic variations among chondrites and refractory phases will require significantly higher precision isotopic measurements on micrometer-sized samples than are currently available.

Brownlee, D. E.↗

Tracking of cells with a compact microscope imaging system with intelligent controls

A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to auto-focus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

McDowell, Mark↗

Effect of the Presence of Chlorates and Perchlorates on the Pyrolysis of Organic Compounds: Implications for Measurements Done with the SAM Experiment Onboard the Curiosity Rover

The Mars Science Laboratory (MSL) Curiosity Rover carries a suite of instruments, one of which is the Sample Analysis at Mars (SAM) experiment. SAM is devoted to the in situ molecular analysis of gases evolving from solid samples collected by Curiosity on Mars surface/sub-surface. Among its three analytical devices, SAM has a gaschromatograph coupled to a quadrupole mass spectrometer (GC-QMS). The GC-QMS is devoted to the separation and identification of organic and inorganic material. Before proceeding to the GC-QMS analysis, the solid sample collected by Curiosity is subjected to a thermal treatment thanks to the pyrolysis oven to release the volatiles into the gas processing system. Depending on the sample, a derivatization method by wet chemistry: MTBSTFA of TMAH can also be applied to analyze the most refractory compounds. The GC is able to separate the organic molecules which are then detected and identified by the QMS (Figure 1). For the second time after the Viking landers in 1976, SAM detected chlorinated organic compounds with the pyrolysis GC-QMS experiment. The detection of perchlorates salts (ClO4-) in soil at the Phoenix Landing site suggests that the chlorohydrocarbons detected could come from the reaction of organics with oxychlorines. Indeed, laboratory pyrolysis experiments have demonstrated that oxychlorines decomposed into molecular oxygen and volatile chlorine (HCl and/or Cl2) when heated which then react with the organic matter in the solid samples by oxidation and/or chlorination processes.

Millan, M.↗

The Oxidation State of Sulfur in Apollo Samples 71035 and 71055

Lunar apatites contain 100s-1000s ppm sulfur [1-3]. This was initially puzzling because lunar basalts are thought to form, including at the time of apatite crystallization, in low oxygen fugacity (fO2) conditions where sulfur exists in its reduced form (S2-), a substitution not previously observed in natural apatite. It has been recently shown, using S-XANES measurements of the oxidation state of sulfur in apatites and proximal mesostasis in the lunar basalts 12039 and 10044, that sulfur is indeed present as S2- in both the mesostasis glass and apatite when measurements were performed far from cracks or pits in the thin section [4]. This observation is consistent with other mineralogical indications of the low fO2 during formation of these samples (~IW-1) such as the presence of Fe-metal, ulvöspinel, ilmenite, fayalite, and silica in the thin sections. In the same study, in addition to clear spectral evidence for the dominance of S2-, analyses of apatite grains in both samples that occurred near cracks or pits in the thin section sometimes revealed non-negligible spectral evidence (e.g., S6+/ΣS > 0.03; [4]) for the presence of S6+. Because S6+ was not observed in the mesostasis glass near the apatite grains measured, or in any phase far from cracks or pits in the studied thin sections, this S6+ was interpreted as either primary S2- in the sulfide altered to S6+ in the thin section, or S6+ of secondary origin, deposited in the fractures of the samples [4, 5]. Whether this is of lunar or terrestrial origin is unknown but has implications for lunar petrogenesis if lunar [e.g., 5], or sample handling and curation if terrestrial. To test between lunar and terrestrial origins for observed S6+ in Apollo-era thin sections, we will measure the oxidation state of sulfur in apatite and associated phases in a specially frozen sample from a boulder sampled at Station 1A during the Apollo 17 mission as part of the NASA Apollo Next Generation Sample Analysis (ANGSA) program. Here, we present “control” measurements of samples 71035 and 71055, using Apollo era thin sections of aliquots of these rocks that were processed upon return to Earth and since stored under N2 atmospheres at room temperature. These will be compared to measurements using newly made thin sections of aliquots of the same rocks (71035 and 71055). In addition, 71036, which has been in cold storage (-20℃) since the return of the Apollo 17 mission to Earth, has been recently made available through the ANGSA program. With 71036 we can test the effect of storage temperature on potential oxidation of S2- to S6+ in the relatively oxidizing and warm conditions of Earth’s surface.

apollo↗

Demonstration of a Lunar Water Extraction and Quantification Technique in a Relevant Environment

The presence of water ice in permanently shadowed regions on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. The first step toward utilizing lunar water ice to advance human space exploration will be to determine the abundance, accessibility, and distribution of this valuable resource. This paper will describe the most recent test results from the Light Water Analysis and Volatile Extraction (Light WAVE) system that was designed to capture icy regolith samples acquired from a drill. Regolith samples are then weighed, sealed, and heated to release volatiles. Volatiles are captured in a volume with a known temperature and the ideal gas law is used to determine the total quantity of volatiles in the volume. The composition of the volatile mixture is determined using a mass spectrometer so that each volatile can be quantified. By quantifying the amount of water extracted from the regolith sample, and acquiring the mass of the sample, water concentration by mass can be determined. The goal of recent testing was to determine the accuracy of water quantification using a combination of ideal gas law and mass spectrometer analysis. The Light WAVE system maybe applied to future water ice investigation missions without an inherent limit to the number of samples that can be processed, and the system may also enable lunar water sample return.

Aaron J Paz↗

Containerless Processing of Glass Forming Melts in Space

The major objectives of this work are: (1) obtain quantitative evidence for the suppression of heterogeneous nucleation/crystallization in containerless melts in micro-g; (2) study melt homogenization in the absence of gravity driven convection; (3) develop the procedures for preparing precursor samples suitable for flight experiments; (4) perform comparative property analysis of glasses melted on Earth and in micro-g; (5) determine the feasibility of preparing glass shells in micro-g for use as laser fusion targets; and (6) assess the operational performance of the single axis acoustic levitator/furnace apparatus for processing multicomponent, glass forming melts in micro-g. Ways of obtaining these goals are discussed.

Day, D. D.↗

Progress of the NASA/USGS Lunar Regolith Simulant Project

Beginning in 2004 personnel at MSFC began serious efforts to develop a new generation of lunar simulants. The first two products were a replication of the previous JSC-1 simulant under a contract to Orbitec and a major workshop in 2005 on future simulant development. Beginning in 2006 the project refocused its efforts and approached simulant development in a new and more comprehensive manner, examining new approaches in simulant development and ways to more accurately compare simulants to actual lunar materials. This led to a multi-year effort with five major tasks running in parallel. The five tasks are Requirements, Lunar Analysis, Process Development, Feed Stocks, and Standards. Major progress has been made in all five areas. A substantial draft of a formal requirements document now exists and has been largely stable since 2007. It does evolve as specific details of the standards and Lunar Analysis efforts proceed. Lunar Analysis has turned out to be vastly more difficult than anticipated. After great effort to mine existing published and gray literature, the team has realized the necessity of making new measurements of the Apollo samples, an effort that is currently in progress. Process development is substantially ahead of expectations in 2006. It is now practical to synthesize glasses of appropriate composition and purity. It is also possible to make agglutinate particles in significant quantities. A series of minerals commonly found on the Moon has been synthesized. Separation of mineral constituents from starting rock material is also proceeding. Customized grinding and mixing processes have been developed and tested are now being documented. Identification and development of appropriate feedstocks has been both easier and more difficult than anticipated. The Stillwater Mining Company, operating in the Stillwater layered mafic intrusive complex of Montana, has been an amazing resource for the project, but finding adequate sources for some of the components remains a difficult problem. For example the ratio of clino- to ortho-pyroxenes in the Stillwater is not an exact match for lunar materials. One of the sources being examined as an alternative pyroxene source is the Bushveld Complex in South Africa. Standards have been a major success for the project. The Figure of Merit algorithms have been created, tested, and are being considered for an ISO standard. Agreement has been reached in the community about how to make many of the critical measurements. There remains much work to do: (1) driving down the cost of simulants remains a major obstacle; (2) documentation and cost data analysis have not kept up with progress; (3) educating users in the complexity of the lunar regolith and the use of simulants remains a major task. In summary the project has made enormous progress and is successfully placing simulant development and use on a rigorous, scientifically defensible, engineering basis.

Rickman, Doug↗

Integrated Analysis of Interferometric SAR, Satellite Altimetry and Hydraulic Modeling to Quantify Louisiana Wetland Dynamics

Wetland loss in Louisiana has been accelerating due primarily to anthropogenic and nature processes, and is being advocated as a problem with national importance. Accurate measurement or modeling of wetland-wide water level changes, its varying extent, its storage and discharge changes resulting in part from sediment loads, erosion and subsidence are fundamental to assessment of hurricane-induced flood hazards and wetland ecology. Here, we use innovative method to integrate interferometric SAR (InSAR) and satellite radar altimetry for measuring absolute or geocentric water level changes and applied the methodology to remote areas of swamp forest in coastal Louisiana. Coherence analysis of InSAR pairs suggested that the HH polarization is preferred for this type of observation, and polarimetric analysis can help to identi:fy double-bonnce backscattering areas in the wetland. Envisat radar altimeter-measured 18- Hz (along-track sampling of 417 m) water level data processed with regional stackfile method have been used to provide vertical references for water bodies separated by levees. The high-resolution (approx.40 m) relative water changes measured from ALOS PALSAR L-band and Radarsat-l C-band InSAR are then integrated with Envisat radar altimetry to obtain absolute water level. The resulting water level time series were validated with in situ gauge observations within the swamp forest. Furthermore, we compare our water elevation changes with 2D flood modeling from LISFLOOD hydrodynamic model. Our study demonstrates that this new technique allows retrospective reconstruction and concurrent monitoring of water conditions and flow dynamics in wetlands, especially those lacking gauge networks.

Lee, Hyongki↗

Regolith Volatile Characterization (RVC) in RESOLVE

Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

Captain, Janine↗

Mars Exploration Architecture

The architecture of NASA's program of robotic Mars exploration missions received an intense scrutiny during the summer months of 1998. We present here the results of that scrutiny, and describe a list of Mars exploration missions which are now being proposed by the nation's space agency. The heart of the new program architecture consists of missions which will return samples of Martian rocks and soil back to Earth for analysis. A primary scientific goal for these missions is to understand Mars as a possible abode of past or present life. The current level of sophistication for detecting markers of biological processes and fossil or extant life forms is much higher in Earth-based laboratories than possible with remotely deployed instrumentation, and will remain so for at least the next decade. Hence, bringing Martian samples back to Earth is considered the best way to search for the desired evidence. A Mars sample return mission takes approximately three years to complete. Transit from Earth to Mars requires almost a single year. After a lapse of time of almost a year at Mars, during which orbital and surface operations can take place, and the correct return launch energy constraints are met, a Mars-to-Earth return flight can be initiated. This return leg also takes approximately one year. Opportunities to launch these 3-year sample return missions occur about every 2 years. The figure depicts schedules for flights to and from Mars for Earth launches in 2003, 2005, 2007 and 2009. Transits for less than 180 deg flight angle, measured from the sun, and more than 180 deg are both shown.

Jordan, James F.↗

Purification of Carbon Nanotubes: Alternative Methods

Traditional carbon nanotube purification process involves nitric acid refluxing and cross flow filtration using surfactant TritonX. This is believed to result in damage to nanotubes and surfactant residue on nanotube surface. Alternative purification procedures involving solvent extraction, thermal zone refining and nitric acid refiuxing are used in the current study. The effect of duration and type of solvent to dissolve impurities including fullerenes and P ACs (polyaromatic compounds) are monitored by nuclear magnetic reasonance, high performance liquid chromatography, and thermogravimetric analysis. Thermal zone refining yielded sample areas rich in nanotubes as seen by scanning electric microscopy. Refluxing in boiling nitric acid seem to improve the nanotube content. Different procedural steps are needed to purify samples produced by laser process compared to arc process. These alternative methods of nanotube purification will be presented along with results from supporting analytical techniques.

Files, Bradley↗

Manual control models of industrial management

The industrial engineer is often required to design and implement control systems and organization for manufacturing and service facilities, to optimize quality, delivery, and yield, and minimize cost. Despite progress in computer science most such systems still employ human operators and managers as real-time control elements. Manual control theory should therefore be applicable to at least some aspects of industrial system design and operations. Formulation of adequate model structures is an essential prerequisite to progress in this area; since real-world production systems invariably include multilevel and multiloop control, and are implemented by timeshared human effort. A modular structure incorporating certain new types of functional element, has been developed. This forms the basis for analysis of an industrial process operation. In this case it appears that managerial controllers operate in a discrete predictive mode based on fast time modelling, with sampling interval related to plant dynamics. Successive aggregation causes reduced response bandwidth and hence increased sampling interval as a function of level.

Crossman, E. R. F. W.↗

Program Collects And Analyzes Thermoelectric Data

Large gradient seebeck coefficient measurement computer program gathers many channels of data, performs analysis, and plots each set of data simutaneously. User can modify code to alter number of channels of data collected and sampling rate and equations that process data. Written in HP Basic. Program also adaptable to other types of data.

Chmielewski, Art B.↗