Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A comparative analysis of residual stresses from friction stir processing of aluminum cast 380 and wrought 7075 alloy sheets: experimental characterization and modeling

Residual stresses are often overlooked in friction stir processing (FSP), but their significant impact on fatigue performance necessitates their consideration in optimizing processing parameters. The first step in this effort is understanding how process conditions influence residual stress distributions, especially across different alloys. This study focuses on determining and explaining the through-thickness residual stress variations and the effect of process temperature on the residual stress magnitude in wrought AA7075 and cast AA380.0 alloys. Additionally, for AA380.0, the impact of a second FSP pass was investigated. To achieve this, hole-drilling electronic speckle pattern interferometry (ESPI) and the thermal pseudo-mechanical (TPM) model within finite element analysis were employed to study the 3D distributions of in-plane residual stresses in processed samples under various conditions. A key finding was the varying impact of process temperatures on residual stress magnitudes. Higher process temperatures reduced stresses in AA380.0 but increased them in AA7075. Additionally, the through-thickness stress distributions differed between the two alloys. Further analysis revealed that yield stresses are crucial in explaining these phenomena and the effects of additional FSP passes. Further, this fundamental understanding will be vital in guiding the efforts to mitigate residual stresses and assess their impact on the performance of FSP aluminum alloys.

36 MATERIALS SCIENCE↗

Semiconductor grade, solar silicon purification project

Experimental apparatus and procedures used in the development of a 3-step SiF2(x) polymer transport purification process are described. Both S.S.M.S. and E.S. analysis demonstrated that major purification had occured and some samples were indistinguishable from semiconductor grade silicon (except possibly for phosphorus). Recent electrical analysis via crystal growth reveals that the product contains compensated phosphorus and boron. The low projected product cost and short energy payback time suggest that the economics of this process will result in a cost less than the goal of $10/Kg(1975 dollars). The process appears to be readily scalable to a major silicon purification facility.

Ingle, W. M.↗

Spatial mapping of dissolved methane using an in situ sensor in Puget Sound

Release of methane, as gas bubbles or in the dissolved phase, from the seafloor has been observed in coastal waters (< 200 m) and deep ocean basins (> 1000 m). Methane dissolution within the water column affects the geochemistry of the surrounding water, leading to localized oxygen loss and potential escape to the atmosphere, particularly from shallower sites. Traditional methods for detecting and quantifying dissolved methane rely on collecting discrete water samples for ship- or land-based ex situ analysis and post processing. Here, we report on the use of a reduced response time, in situ methane sensor, the Sensor for Aqueous Gases in the Environment (SAGE), for detecting and quantifying dissolved methane concentrations in a wide range of seafloor environments. During a Fall 2022 research cruise on the R/V Thomas G. Thompson in Puget Sound, SAGE was integrated onto a towed conductivity/temperature/depth rosette and deep-sea camera system with live-stream 1 Hz telemetry and used to spatially map the concentration of methane approximately 1 m above the seafloor. The site had been previously identified as an active methane plume field characterized by gas bubbles, fluid venting, and a faulted seabed. The widespread background dissolved concentration of methane measured by SAGE was 83 nM, and a range of 78–670 nM was observed throughout the survey. The results highlight the capacity of SAGE to map the spatial and temporal variability of dissolved methane concentrations in situ and to identify and localize sites of variable methane emissions from the seafloor.

Padilla, Alexandra M. [Woods Hole Oceanographic In↗

Liquid Scintillation Counting of Environmental Radioisotopes: A Review of the Impact of Background Reduction

Liquid scintillation counting (LSC) is a versatile and commonplace method for radiometric measurement of charged particle emitting radionuclides. The LSC method provides utility in a range of environmental science applications including hydrological studies of water transport, anthropogenic releases of radionuclides into the environment, and vertical mixing rates within oceans. Instrumental measurement background is one limiting factor of radiometric measurement sensitivity. As part of the development of a custom low background LSC system located in a shallow underground laboratory at Pacific Northwest National Laboratory, a number of measurement applications of LSC have been considered and are summarized here. The focus is on determining which aspects of such measurements would gain the greatest benefit from the reduction of LSC backgrounds by a factor of 10-100 relative to values reported in the literature. Examples of benefits include lowering the minimum detectable activity, reducing the sample size required, and shortening the elapsed timeline of the processing and analysis sequence. In particular tritium, strontium, and actinium isotopes are examined as these isotopes cover a range of requirements related to the LSC measurement method (e.g., 3H: low energy; Sr: spectral deconvolution; Ac: alpha/beta discrimination).

actinium↗

Improving Photostability of Cesium-Doped Formamidinium Lead Triiodide Perovskite

Using time-resolved in situ X-ray photoelectron spectroscopy, we identify and suppress rapid degradation mechanisms for cesium-stabilized formamidinium lead iodide perovskite materials used in state-of-the-art photovoltaics. Accelerated degradation under high light intensity and heating reveals a photocatalytic reaction pathway responsible for rapid decomposition in iodide-rich compositions and a slower pathway for more stoichiometric samples. Using Avrami–Erofe’ev kinetic analysis, we find that the fast process is consistent with a 2D crystallization and growth mechanism fueled by excess halide salt at grain boundaries and surfaces. Moreover, the rate of decomposition varies dramatically with the wavelength of light used to illuminate the thin films. Furthermore, our results reveal the photodegradation mechanisms of PbI 2 and excess iodide and provide a path to increasing perovskite stability under photoexcitation.

14 SOLAR ENERGY↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A comparative study on shock compression of nanocrystalline Al and Cu: Shock profiles and microscopic views of plasticity

Shock compressions of nanocrystalline (nc) metals Al and Cu with the same grain size and texture are studied by using molecular dynamics simulations. Results have revealed that the shock front of both Al and Cu can be divided into three stages: elastic, grain-boundary-mediated, and dislocation-mediated plastic deformation. The transition planes among these three stages are proven to be non-planar by two-dimensional shock response analysis, including local stress, shear, temperature, and atom configuration. The difference between shocked Al and Cu is that the rise rate of the elastic stage of Cu is slightly higher than that of Al, and that the shock-front width of Al is wider than Cu at the same loading conditions. For the plastic stage, the dislocation density of shocked Al is lower than Cu, and the contribution of grain-boundary-mediated plasticity to shock front and strain for nc Al is more pronounced than for nc Cu. These results are explained through intrinsic material properties and atomistic analysis of the plastic process. In the case of the shocked Al sample, partial dislocations, perfect dislocations, and twins are observed, but few evidence of perfect dislocations and twins are observed in the shocked Cu.

36 MATERIALS SCIENCE↗

Determination of the Spin and Parity of the Z c ( 3900 )

In this paper, the spin and parity of the Z c (3900) ± state are determined to be J P = 1 + with a statistical significance larger than 7σ over other quantum numbers in a partial wave analysis of the process e + e - &rarr; &pi; + &pi; - J/Ψ. We use a data sample of 1.92 fb -1 accumulated at $ \sqrt{s}=4.23 $ and 4.26 GeV with the BESIII experiment. When parametrizing the Z c (3900) ± with a Flatté-like formula, we determine its pole mass M pole = (3881.2±4.2 stat ±52.7 syst ) MeV/c 2 and pole width Γ pole = (51.8± 4.6 stat ± 36.0 syst ) MeV. Finally, we also measure cross sections for the process e + e - &rarr; Z c (3900) + &pi; - + c.c. &rarr; J/Ψ&pi; + &pi; - and determine an upper limit at the 90% confidence level for the process e + e - &rarr; Z c (4020) + &pi; - + c.c. &rarr; J/Ψ &pi; + &pi; - .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2012-13 Blue Room Low Enriched Uranium Sample Irradiation, Associated Gas Handling System, and Subsequent Separation Chemistry

An irradiation experiment was designed for the production of 100 mCi of medical isotope Mo-99 from a Low Enriched Uranium (LEU) solution. 300 mL of 150 gU/L LEU sulfate solution (pH1) was prepared and irradiated at the LANSCE Blue Room facility. The apparatus designed for the irradiation included a gas handling system, in which safe operation could be controlled by monitoring change in gas pressure. The gas handling system also contained a hydrogen oxygen recombiner, to recombine the gases generated through radiolysis of water, and an iodine trap, primarily for I-131. Pressure transients were observed during irradiation, which could be controlled by increasing the flow rate of the circulating pump. After irradiation the LEU solution was transferred to a hot cell facility for subsequent Mo-99 recovery using a titania column separation process, with samples also subsequently shipped to a radiochemical laboratory for further analysis. Gamma spectroscopy analysis revealed that ca. 70 mCi of Mo-99 was present at end of beam, in good agreement with the predicted value when actual beam history was included into the calculation. There was 80-85 % recovery of Mo-99 through a titania column separation, excluding losses through radioactive decay. The % Mo-99 recovery was lower than observed previously for the 1 mCi Mo-99 production (Target 4) experiments undertaken at LANL using the same separation apparatus, with on this occasion evidence of lower oxidation state molybdenum remaining irreversibly bound to the titania column. Subsequent postmortem analysis of the Blue room apparatus revealed that there had been no leaks in the gas handling system, the hydrogen and oxygen recombination appeared to work efficiently, and recovery of irradiated uranium trapped in the system allowed for >99% uranium mass balance.

07 ISOTOPE AND RADIATION SOURCES↗

Data Validation Package April 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites August 2016

This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Complete sample sets were collected from 42 of 48 planned locations (9 of 9 former mill site wells, 13 of 13 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Locations R6-M3, SW00-01, Seep 1, Seep 2, and Seep 5 were not sampled due to insufficient water availability. A partial sample was collected at location R4-M3 due to insufficient water. All samples from the permeable reactive barrier wells were filtered as specified in the program directive. Duplicate samples were collected from surface water location Sorenson and from monitoring wells 92-07 and RlO-Ml. Water levels were measured at all sampled wells and an additional set of wells. See Attachment2, Trip Report for additional details. The contaminants of concern (COCs) for the Monticello sites are arsenic, manganese, molybdenum, nitrate+ nitrite as nitrogen (nitrate+ nitrite as N), selenium, uranium, and vanadium. Locations with COCs that exceeded remediation goals are listed in Table 1 and Table 2. Time-concentration graphs of the COCs for all groundwater and surface water locations are included in Attachment 3, Data Presentation. An assessment of anomalous data is included in Attachment 4.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package October 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites January 2017

Sampling Period: October 10–12, 2016. This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Samples were collected from 54 of 64 planned locations (16 of 17 former mill site wells, 15 of 18 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 3 of 3 bedrock wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations).

54 ENVIRONMENTAL SCIENCES↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Apollo 12 soil and breccia

Apollo 12 lunar soil and breccia core tube and surface samples optical and electron microscope and microprobe analysis, relating data to geologic processes

Clanton, U. S.↗

Low-gravity homogenization and solidification of aluminum antimonide

The III-V semiconducting compound AlSb shows promise as a highly efficient solar cell material, but it has not been commercially exploited because of difficulties in compound synthesis. Liquid state homogenization and solidification of AlSb were carried out in the Apollo-Soyuz Test Project Experiment MA-044 in the hope that compositional homogeneity would be improved by negating the large density difference between the two constituents. Post-flight analysis and comparative characterization of the space-processed and ground-processed samples indicate that there are major homogeneity improvements in the low-gravity solidified material.

Ang, C.-Y.↗

Microfossils in the Antarctic cold desert: Possible implications for Mars

In the Ross Desert of Antarctica, the principal life form is the cryptoendolithic microbial community in the near-surface layers of porous sandstone rocks. Biological, geological, and climatic factors interact in a complex and precarious balance, making life possible in an otherwise hostile environment. Once this balance is tipped, fossilization sets in. In the reverse case, new colonization of the rock surface may be initiated. As a result, fossilization is contemporary with modern life and both may be simultaneously present in a mosaic pattern. Also, different stages of fossilization are present. The process of fossilization takes place in a nonaquatic environment. If primitive life ever appeared on Mars, it is possible that with increasing aridity, life withdrew into an endolithic niche similar to that in the Antarctic desert. Fossilization in a nonaquatic environment may have set in with the result that traces of past life could be preserved. If such was the case, the study of the fossilization process in Antarctica may hold useful information for the analysis of Martian samples for microfossils.

Friedmann, E. I.↗

Automated Drug Identification for Urban Hospitals

Many urban hospitals are becoming overloaded with drug abuse cases requiring chemical analysis for identification of drugs. In this paper, the requirements for chemical analysis of body fluids for drugs are determined and a system model for automated drug analysis is selected. The system as modeled, would perform chemical preparation of samples, gas-liquid chromatographic separation of drugs in the chemically prepared samples, infrared spectrophotometric analysis of the drugs, and would utilize automatic data processing and control for drug identification. Requirements of cost, maintainability, reliability, flexibility, and operability are considered.

Shirley, Donna L.↗

Influence of Microgravity on Bacterial Pathogen Virulence and Immune Cell Function—Relevance for Infectious Disease Risk During Spaceflight

Spaceflight has measurable impacts on astronaut immune profiles as well as the virulence patterns of bacterial pathogens. Data with respect to human immunity indicate diminished T and NK cell function, altered cytokine profiles, persistent inflammation, and latent herpesvirus reactivation. Furthermore, evaluation of International Space Station (ISS) crewmembers gives evidence of compromised immunity, including atypical allergy, infectious disease, and dermatitis. Data with respect to certain human bacterial pathogens suggest modified virulence that may be enhanced. It is therefore critical to examine this interaction of immune dysregulation and increased microbial virulence and whether it might synergistically increase the risk of infectious disease to crew members. The goal of this study is to use modeled microgravity to study the impact of medically significant ISS bacteria that may have altered virulence on the immune response of the host. This study consists of two primary aims to assess this relationship. First, immune cells will be collected from healthy test subjects and cultured in static or in modeled microgravity conditions together with either control pathogens or with microgravity conditioned pathogens that were grown in bioreactors. Second, immune cells will be collected from astronauts before, during, and after flight and co-cultured with the control or the microgravity conditioned bacteria. Three pathogens were selected for this investigation: Pseudomonas aeruginosa , Salmonella enterica serovar Enteritidis and Burkholderia cepacia . Previously, the optimal cell to bacteria ratios that produce the greatest immune cell responses have been derived for these three bacteria. Cellular activation, as determined by the induction of cell surface activation markers and cytokine profiles, will be measured. Interactions between cells and bacteria will be assessed using fluorescent and electron microscopy techniques. This study will provide critical information to help understand how microgravity alters microbial virulence and the associated infectious disease risk to crewmembers during spaceflight missions. Over the past year, the Immunology and Microbiology laboratories at NASA Johnson Space Center have collaborated to process the astronaut subject samples to complete the last year of the flight portion of this study. This included the completion of four astronaut subjects full mission sampling sets. Sample processing included innate and adaptive cell flow cytometry as well as analysis of cytokine concentrations in the supernatant. The ground control segment of the study will take place during FY25 which involves parallel infections run under static and clinostat conditions. The acquired data sets over this 3-year study are now being analyzed to provide a comprehensive set of results and conclusions that will contribute to a more effective risk assessment for astronauts during spaceflight regarding this host-pathogen context.

Immunology↗