Evaluation of Physical Security Risk for Potential Implementation of FLEX using Dynamic Simulation Methods

The requirements for United States nuclear power plants to maintain a large onsite physical security force contribute to their large operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability Program Physical Security Pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. This pathway will analyze and minimize the conservatisms built into current security postures in order to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within this pathway has successfully developed a dynamic force-on-force (FOF) modeling framework using various computer simulation tools and integrated them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This document provides an overview of lessons learned in applying a dynamic computational framework that links results from a commercially available FOF simulation tool, a commercially available thermal-hydraulic tool, and EMRALD to an operating commercial nuclear power plant. This process of including plant procedures and multiple analysis results is being called Modeling and Analysis for Safety Security using Dynamic EMRALD Framework. Previous reports described how a user could integrate their plant-specific FOF models with the dynamic simulation tool EMRALD, model operator actions, integrate with probabilistic risk assessment tools, such as Computer Aided Fault Tree Analysis System or Systems Analysis Programs for Hands-on Integrated Reliability Evaluations, and with thermal-hydraulic tools, such as RELAP-5. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report documents the results of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. The purpose of this study was to verify that results achieved using generic models are similar to actual plant results and to refine our guidance of the use of the framework. Such an assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants. NOTE: The work performed in this report is based on a generic EMRALD model with actual plant data used for the analysis. However, only the generic model and general results of the analysis are in the report. No plant’s sensitive information is discussed in this report. The discussion shows examples of insights that can be obtained from the MASS-DEF methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prognosis of Wind Turbine Gearbox Bearing Failures Using SCADA and Modeled Data

Predictive maintenance and condition monitoring systems for wind turbines have seen increased adoption to minimize downtime, reducing operation and maintenance costs. On today’s wind power plants, the integrated supervisory control and data acquisition (SCADA) system provides low- frequency operational data that can be leveraged to quantify a wind turbine’s health. The aim of this study is to utilize machine-learning techniques to predict axial cracking failures in wind turbine gearbox bearings up to 1 month ahead of time. The failures are assumed to have occurred when the investigated bearing was replaced. While current SCADA systems show the overall condition of a wind turbine, often they do not allow for the investigation of specific gearbox bearings’ health. To enrich bearing fault signatures, additional data are computed through physics-based models using gearbox design information. Based on SCADA data, modeled data, and bearing failure log data from an actual wind plant, the performances of different machine-learning models on unseen data are then evaluated using industry-standard metrics such as precision, recall, and F1 score. Results show the overall system performance enhancement in predicting bearing failure when modeled data are included with SCADA data. The reduction in terms of false alarms is about 50%, and improvement in terms of precision and F1 score is about 33% and 12% respectively, based on the best modeling case in this study.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Refining Processing Engines from SAPHIRE: Initialization of Fault Tree/Event Tree Solver

SAPHIRE has been extensively employed for over 35 years to model risk-important systems and quantify risk models. As a well-established and thoroughly documented Probabilistic Risk Assessment (PRA) tool, SAPHIRE has continuously tracked computational trends and received regular updates. Despite its ongoing evolution, there remains a need for further enhancements, particularly in dealing with the quantification of exceptionally large models. These improvements could take the form of algorithmic advancements, harnessing the power of parallel computing, and exploring the potential benefits of cloud computing solutions. Considering these aspirations, the notion of a remote solve option was introduced and subsequently evolved into a dedicated project within the SAPHIRE development team. A significant outcome of this initiative is SAPHSOLVE, an engine extracted from the SageRisk API designed specifically for remote solving capabilities. The ongoing project is nearing its culmination, marked by a series of discoveries that have brought undocumented aspects to light. Among these revelations is the intricacy of the input and output format for the SAPHSOLVE engine. This document serves the crucial purpose of meticulously delineating the precise formats for both input and output, as they form an indispensable foundation. The importance of documenting these formats cannot be overstated, as it is a pivotal step in facilitating rigorous testing and comparison. Whether it involves scrutinizing SAPHSOLVE results against those of the internal integrated solver or other external solvers, the ability to construct models or transform existing ones into a compatible SAPHSOLVE format is imperative. Chapter 1 offers a succinct introduction to both SAPHIRE and SAPHSOLVE, followed by Chapter 2 which outlines the roadmap for enhancing SAPHSOLVE. The core of this report is Chapter 3, which intricately elucidates the intricacies of the input and output file formats. To provide a tangible illustration of these formats, a rudimentary example has been compiled and is available in Appendix. SAPHSOLVE represents a novel external solving mechanism developed by the SAPHIRE team, although it has not yet reached the full spectrum of capabilities possessed by SAPHIRE's internal solver. However, the SAPHIRE team has set a comprehensive course for incorporating the functionalities of SAPHSOLVE. A comprehensive outlook on the future of SAPHSOLVE is expounded upon in Chapter 4.

97 MATHEMATICS AND COMPUTING↗

Development and assessment of a reactor system prognosis model with physics-guided machine learning

Autonomous control systems provide recommendations to help operators in decision-making during plant operations ranging from normal operation to accident management. An important step of autonomous control is prognosis. In nuclear engineering domain, prognosis is the process of predicting future conditions of a system or equipment based on present signs and symptoms of a fault. The prognosis model allows predicting future reactor states for possible candidate control strategies so that the outcomes can be evaluated to determine the best control strategy. The prognosis model requires representing direct relationships between the symptoms and the predictions. In nuclear engineering, computational simulations are approximate representations of the operation of the real system. However, prognosis with computational simulations requires high computation power and time due to possible large number of scenarios. Necessary computation resources can be reduced with machine learning (ML) approach for fast predictions by building a surrogate function using the simulation data. A critical issue is, ML models are ignorant of physical knowledge, and these models approximate statistical relationships between the system variables. This ignorance can produce results that are inconsistent with physical laws, even if an optimal result is achieved from a mathematical point of view. Physics-guided machine learning (PGML) is an approach to tackle this issue. Here, this work formulates and illustrates a framework to guide development and assessment of the ML-based prognosis model for autonomous control systems. The development of the prognosis model considers the training of a ML model which consists of optimizing many aspects of the ML approach. The assessment of the prognosis model considers training data limitations and uncertainties of the ML approach. Prognosis models with standalone ML and PGML are developed and assessed on the loss-of-flow scenario of Experimental Breeder Reactor II. The results indicate that PGML based prognosis model has the best performance compared to other prognosis models.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multiple aspects maintenance ontology-based intelligent maintenance optimization framework for safety-critical systems

Abstract Maintenance optimization is a process for improving the efficiency of maintenance strategies and activities, considering various aspects of the target system and components, such as the probabilities of system failures and the cost of repair and replacement of a failed component. The improvement of maintenance optimization algorithms generally requires information from various data sources. For example, it may require the system risk information derived from risk analysis tools or the residual lifetime of a component from fault prognosis tools. The requirements of data acquisition (DAQ) and aggregation pose new challenges for maintenance management systems (MMSs) that implement and use these maintenance optimization algorithms. This paper proposes a multiple aspects maintenance ontology-based framework to facilitate DAQ from MMSs, online monitoring systems, fault detection and discrimination tools, risk assessment tools, decision-making tools, and component identification tools, and accelerate the implementation and verification of contemporary maintenance optimization models and algorithms. The proposed framework consists of a multi-aspect maintenance ontology with critical information for maintenance optimization and application interfaces for collecting information from various data sources, such as fault prognosis tools, online monitoring tools, risk assessment tools, and decision-making algorithms. In addition, this paper proposes a heuristic method for integrating concepts and properties from other existing ontologies into the proposed framework when the existing ontology is not fully compatible with the ontology under construction. Finally, the paper verifies the proposed ontology framework using a feedwater system designed for nuclear power plants with valves and filters as the components under maintenance.

Diao, Xiaoxu (ORCID:0000000346726352)↗

Event Detection and Classification Using Machine Learning Applied to PMU Data for the Western US Power System

Smart grid technology enhances our comprehension and reliability of the power grid, leveraging Phasor Measurement Unit (PMU) data—time-synchronized, high-frequency measurements gathered across the US power grid. This paper employs machine learning techniques to effectively analyze the vast PMU data in Wide Area Monitoring Systems (WAMS) for power grid event detection and classification. Analyzing several months of real-world PMU data, the paper focuses on machine learning for fast, precise event detection and classification, corroborated by utility event logs. Practical challenges like feature extraction, dimensionality reduction, and model selection are addressed. A novel feature yielding improved results is discovered, and a supplementary algorithm for detecting small power grid faults is developed. The final algorithm is validated using a month-long real PMU data set, demonstrating its capability in accurately identifying power grid events in near real-time.

machine learning, event detection, PMU↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

EMIS↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytics-at-scale of Sensor Data for Digital Monitoring in Nuclear Plants: 2nd Annual Report

For economic reasons, the nuclear industry is witnessing premature closure of nuclear power plants, despite excellent safety records. Operations and Maintenance (O&M) activities are some of the largest costs in operating legacy light-water plants. By reducing O&M costs, nuclear energy can become more economically competitive with other energy sources. This can be achieved by leveraging machine-learning and artificial intelligence technologies to develop data-driven algorithms to better diagnose potential faults within the system. Improved accuracy of the models can lead to a reduction in unnecessary maintenance, thus reducing costs associated with parts, labor, and unnecessary planned, forced, or extended outages. To address these challenges, the goal of this project is to perform research and development in the area of digital monitoring, i.e., the application of advanced sensor technologies (particularly wireless sensor technologies) and data science based analytic capabilities, to advance online monitoring and predictive maintenance in nuclear plants and improve plant performance (efficiency gain and economic competitiveness). This report summarizes the fiscal year 2020 research progress encompassing (1) different wireless vibration sensor and data indicators used to assess the health of a plant asset; (2) development of diagnostic models for fault detection; and (3) development of prognostic models for estimating the health of the system up to 7 days ahead.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applied Research and Development to Support Open-Water Testing at PacWave

This report presents the findings from Task 7 of the project, which focused on improving the performance and reliability of wave energy converters (WECs) under real-world conditions, particularly in the presence of marine growth (biofouling) and system faults. The work was conducted using the RM3 point absorber WEC model, a marine current turbine based on the SHARKS project model, and the WEC-Sim simulation platform, and it included both modeling and control system development.

16 TIDAL AND WAVE POWER↗

Explainable AI for Multivariate Time Series Pattern Exploration: Latent Space Visual Analytics With Temporal Fusion Transformer and Variational Autoencoders in Power Grid Event Diagnosis

Detecting and analyzing complex patterns in multivariate time-series data is crucial for decision-making in urban and environmental system operations. However, challenges arise from the high dimensionality, intricate complexity, and interconnected nature of complex patterns, which hinder the understanding of their underlying physical processes. Existing AI methods often face limitations in interpretability, computational efficiency, and scalability, reducing their applicability in real-world scenarios. This paper proposes a novel visual analytics framework that integrates two generative AI models, Temporal Fusion Transformer (TFT) and Variational Autoencoders (VAEs), to reduce complex patterns into lower-dimensional latent spaces and visualize them in 2D using dimensionality reduction techniques such as PCA, t-SNE, and UMAP with DBSCAN. These visualizations, presented through coordinated and interactive views and tailored glyphs, enable intuitive exploration of complex multivariate temporal patterns, identifying patterns’ similarities and uncover their potential correlations for a better interpretability of the AI outputs. The framework is demonstrated through a case study on power grid signal data, where it identifies multi-label grid event signatures, including faults and anomalies with diverse root causes. Additionally, novel metrics and visualizations are introduced to validate the models and assess the performance, efficiency, and consistency of latent maps generated by VAE, which have been utilized in prior studies for latent space cartography and used as a benchmark in this study, and the emerging TFT architecture under various configurations. These analyses provide actionable insights for model parameter tuning and reliability improvements. Comparative results highlight that TFT achieves shorter run times and superior scalability to diverse time-series data shapes compared to VAE. This work advances fault diagnosis in multivariate time series, fostering explainable AI to support critical system operations.

Explainable AI↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrating Survival Analysis with Bayesian Statistics to Forecast the Remaining Useful Life of a Centrifugal Pump Conditional to Multiple Fault Types

To improve the viability of nuclear power plants, there is a need to reduce their operational costs. Operational costs account for a significant portion of a plant’s yearly budget, due to their scheduled-based maintenance approach. In order to reduce these costs, proactive methods are required that estimate and forecast the state of a machine in real time to optimize maintenance schedules. In this research, we use Bayesian networks to develop a framework that can forecast the remaining useful life of a centrifugal pump. To do so, we integrate survival analysis with Bayesian statistics to forecast the health of the pump conditional to its current state. We complete our research by successfully using the Bayesian network on a case study. This solution provides an informed probabilistic viewpoint of the pumping system for the purpose of predictive maintenance.

42 ENGINEERING↗