Large HAWT wake measurement and analysis

From the theoretical fluid dynamics point of view, the wake region of a large horizontal-axis wind turbine has been defined and described, and numerical models of wake behavior have been developed. Wind tunnel studies of single turbine wakes and turbine array wakes have been used to verify the theory and further refine the numerical models. However, the effects of scaling, rotor solidity, and topography on wake behavior are questions that remain unanswered. In the wind tunnel studies, turbines were represented by anything from scaled models to tea strainers or wire mesh disks whose solidity was equivalent to that of a typical wind turbine. The scale factor compensation for the difference in Reynolds number between the scale model and an actual turbine is complex, and not typically accounted for. Though it is wise to study the simpler case of wakes in flat topography, which can be easily duplicated in the wind tunnel, current indications are that wind turbine farm development is actually occurring in somewhat more complex terrain. Empirical wake studies using large horizontal-axis wind turbines have not been thoroughly composited, and, therefore, the results have not been applied to the well-developed theory of wake structure. The measurement programs have made use of both in situ sensor systems, such as instrumented towers, and remote sensors, such as kites and tethered, balloonborne anemometers. We present a concise overview of the work that has been performed, including our own, which is based on the philosophy that the MOD-2 turbines are probably their own best detector of both the momentum deficit and the induced turbulence effect downwind. Only the momentum deficit aspects of the wake/machine interactions have been addressed. Both turbine power output deficits and wind energy deficits as measured by the onsite meteorological towers have been analyzed from a composite data set. The analysis has also evidenced certain topographic influences on the operation of spatially diverse wind turbines.

Miller, A. H.↗

Wind tower service lift

An apparatus used for maintaining a wind tower structure wherein the wind tower structure may have a plurality of legs and may be configured to support a wind turbine above the ground in a better position to interface with winds. The lift structure may be configured for carrying objects and have a guide system and drive system for mechanically communicating with a primary cable, rail or other first elongate member attached to the wind tower structure. The drive system and guide system may transmit forces that move the lift relative to the cable and thereby relative to the wind tower structure. A control interface may be included for controlling the amount and direction of the power into the guide system and drive system thereby causing the guide system and drive system to move the lift relative to said first elongate member such that said lift moves relative to said wind tower structure.

17 WIND ENERGY↗

Solar Receiver with Integrated Thermal Storage for a Supercritical Carbon Dioxide Power Cycle

This project endeavors to design and demonstrate an integrated CSP system that meets the Department of Energy’s 6¢/kW-hr LCOE goal. This design is based on the 10 MW e Supercritical Transformational Electric Power (STEP) engine specifications, but adaptable to any sCO 2 power module up to 10 MW e . The enabling technology to be tested is a new class of metal hydride based thermal energy storage materials which can store thermal energy in the hydrogen bonds between the metal hydride and hydrogen. This thermochemical energy storage solution provides a much greater energy density than sensible and latent energy storage enabling an integrated system design that closely linked the metal hydride to the power block. This allows the entire system to be mounted up tower to provide cost reductions.

14 SOLAR ENERGY↗

Capabilities and constraints of combustion diagnostics in microgravity

A significant scientific return from both existing and proposed microgravity combustion science experiments is substantially dependent on the availability of diagnostic systems for the collection of the required scientific data. To date, the available diagnostic instrumentation has consisted primarily of conventional photographic media and intrusive temperature and velocity probes, such as thermocouples and hot wire anemometers. This situation has arisen primarily due to the unique and severe operational constraints inherent in reduced gravity experimentation. Each of the various reduced gravity facilities is accompanied by its own peculiar envelope of capabilities and constraints. Drop towers, for example, pose strict limitations on available working volume and power, as well as autonomy of operation. In contrast, hardware developed for space flight applications can be somewhat less constrained in regards to the aforementioned quantities, but is additionally concerned with numerous issues involving safety and reliability.

Greenberg, Paul S.↗

Desalination of Impaired Water Using Geothermal Energy

Membrane distillation (MD) and nanofiltration (NF) are explored as a means to provide high quality water for on-site use at the Tuscarora geothermal power plant in northern Nevada. The plant uses a wet cooling tower, but decreasing flow from the wells providing makeup water necessitates exploration for alternative water or alternative cooling sources. Scenarios are explored to extend cooling water by (1) extracting fresh water from the geothermal brine, (2) upgrading the makeup-water quality to allow for increased cycles of concentration in the cooling tower, or (3) recovering water from the cooling tower blowdown. The preliminary cost analysis indicates that applying NF to extract water from the injection brine is the most attractive option of the scenarios examined. This approach may be useful for other plants as well. The estimated cost for the NF treatment of the injection brine ranges from $0.63/m3 to $0.45/m3 and provides a reduction in the current makeup well flows of 35% to 71%. Savings from the reduction in makeup well pumping and chemical treatment do not fully offset the estimated cost of the proposed treatment systems; the site will have to weigh the cost of these water treatment options versus alternatives in light of the diminishing flows from the existing cooling-water wells. Testing is planned to quantify the performance of the proposed NF and MD technologies and help refine the estimated system costs.

15 GEOTHERMAL ENERGY↗

A Synergistic Combination of Advanced Separation and Chemical Scale Inhibitor Technologies for Efficient Use of Imparied Water As Cooling Water in Coal-based Power Plants

Nalco Company is partnering with Argonne National Laboratory (ANL) in this project to jointly develop advanced scale control technologies that will provide cost-effective solutions for coal-based power plants to operate recirculating cooling water systems at high cycles using impaired waters. The overall approach is to use combinations of novel membrane separations and scale inhibitor technologies that will work synergistically, with membrane separations reducing the scaling potential of the cooling water and scale inhibitors extending the safe operating range of the cooling water system. The project started on March 31, 2006 and ended in August 30, 2010. The project was a multiyear, multi-phase project with laboratory research and development as well as a small pilot-scale field demonstration. In Phase 1 (Technical Targets and Proof of Concept), the objectives were to establish quantitative technical targets and develop calcite and silica scale inhibitor chemistries for high stress conditions. Additional Phase I work included bench-scale testing to determine the feasibility of two membrane separation technologies (electrodialysis ED and electrode-ionization EDI) for scale minimization. In Phase 2 (Technology Development and Integration), the objectives were to develop additional novel scale inhibitor chemistries, develop selected separation processes, and optimize the integration of the technology components at the laboratory scale. Phase 3 (Technology Validation) validated the integrated system's performance with a pilot-scale demonstration. During Phase 1, Initial evaluations of impaired water characteristics focused on produced waters and reclaimed municipal wastewater effluents. Literature and new data were collected and evaluated. Characteristics of produced waters vary significantly from one site to another, whereas reclaimed municipal wastewater effluents have relatively more uniform characteristics. Assessment to date confirmed that calcite and silica/silicate are two common potential cycle-limiting minerals for using impaired waters. For produced waters, barium sulfate and calcium sulfate are two additional potential cycle-limiting minerals. For reclaimed municipal wastewater effluents, calcium phosphate scaling can be an issue, especially in the co-presence of high silica. Computational assessment, using a vast amount of Nalco's field data from coal fired power plants, showed that the limited use and reuse of impaired waters is due to the formation of deposit caused by the presence of iron, high hardness, high silica and high alkalinity in the water. Appropriate and cost-effective inhibitors were identified and developed - LL99B0 for calcite and gypsum inhibition and TX-15060 for silica inhibition. Nalco's existing dispersants HSP-1 and HSP-2 has excellent efficacy for dispersing Fe and Mn. ED and EDI were bench-scale tested by the CRADA partner Argonne National Laboratory for hardness, alkalinity and silica removal from synthetic make-up water and then cycled cooling water. Both systems showed low power consumption and 98-99% salt removal, however, the EDI system required 25-30% less power for silica removal. For Phase 2, the EDI system's performance was optimized and the length of time between clean-in-place (CIP) increased by varying the wafer composition and membrane configuration. The enhanced EDI system could remove 88% of the hardness and 99% of the alkalinity with a processing flux of 19.2 gal/hr/m{sup 2} and a power consumption of 0.54 kWh/100 gal water. Bench tests to screen alternative silica/silicate scale inhibitor chemistries have begun. The silica/silicate control approaches using chemical inhibitors include inhibition of silicic acid polymerization and dispersion of silica/silicate crystals. Tests were conducted with an initial silica concentration of 290-300 mg/L as SiO{sub 2} at pH 7 and room temperature. A proprietary new chemistry was found to be promising, compared with a current commercial product commonly used for silica/silicate control. Additional pilot cooling tower testing confirmed the bench study. We also developed a molecule to inhibit calcium carbonate precipitation and calcium sulfate precipitation at high supersaturations. During Phase 3, a long-term test of the EDI system and scale inhibitors was done at Nalco's cooling tower water testing facility, producing 850 gallons of high purity water (90+% salt removal) at a rate of 220 L/day. The EDI system's performance was stable when the salt concentration in the concentrate compartment (i.e. the EDI waste stream) was controlled and a CIP was done after every 48 hours of operation time. A combination of EDI and scale inhibitors completely eliminated blowdown discharge from the Pilot cooling Tower. The only water-consumption came from evaporation, CIP and EDI concentrate. Silica Inhibitor was evaluated in the field at a western coal fired power plant.

01 COAL, LIGNITE, AND PEAT↗

In-Space Transportation for Geo Space Solar Satellites

Space solar power satellites have the potential to provide abundant quantities of electricity for use on Earth. One concept, the Sun Tower, can be assembled in geostationary orbit from pieces transferred from Earth. The cost of transportation from Earth is one of the major hurdles to space solar power. This study found that a two-stage rocket launch vehicle with autonomous solar-electric transfer can provide the transportation at prices close to the goal of $800/kg

Martin, James A.↗

FAST.Farm Development and Validation of Structural Load Prediction Against Large Eddy Simulations

FAST.Farm is a mid-fidelity engineering tool developed by the National Renewable Energy Laboratory targeted at accurately and efficiently predicting wind turbine power production and structural loading in wind farm settings, including wake interactions between turbines. FAST.Farm is based on several principles of the dynamic wake meandering (DWM) model, but also addresses limitations of previous DWM implementations. Previous FAST.Farm studies have shown the similarities and differences between FAST.Farm and large eddy simulations for rigid turbine cases. The objective of this work is to quantify the ability of FAST.Farm to accurately predict turbine structural response in a small wind farm. This is done by comparing FAST.Farm structural response to SOWFA-OpenFAST results for three laterally-aligned turbines. The purpose of this study is to characterize the similarities and differences between FAST.Farm and a higher fidelity model for predicting turbine structural response in a wind farm for differing atmospheric inflows. Strong statistical agreement was found between FAST.Farm and SOWFA-OpenFAST structural response for the non-waked upstream turbine, and good agreement was found for the downstream turbines for most structural quantities. Higher differences were seen for downstream turbines with low ambient turbulence intensity or yawed turbines, suggesting areas for FAST.Farm wake dynamics modeling improvements. For all cases and turbines, small statistical differences were seen between blade deflections and bending moments, with larger differences for tower-top and tower-base bending moments. Overall, the results establish confidence for applying FAST.Farm to wind farm power and loads analyses and identify areas where further model validations and model improvements should be targeted.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Potential errors in using one anemometer to characterize the wind power over an entire rotor disk

Wind data collected at four levels on a 90-m tower in a prospective wind farm area are used to evaluate how well the 10-m wind speed data with and without intermittent vertical profile measurements compare with the 90-m tower data. If a standard, or even predictable, wind speed profile existed, there would be no need for a large, expensive tower. This cost differential becomes even more significant if several towers are needed to study a prospective wind farm.

Simon, R. L.↗

Aerodynamic Testing of the Orion Launch Abort Tower Separation with Jettison Motor Jet Interactions

The aerodynamic database for the Orion Launch Abort System (LAS) was developed largely from wind tunnel tests involving powered jet simulations of the rocket exhaust plumes, supported by computational fluid dynamics (CFD) simulations. The LAS contains three solid rocket motors used in various phases of an abort to provide propulsion, steering, and Launch Abort Tower (LAT) jettison from the Crew Module (CM). This paper describes a pair of wind tunnel experiments performed at transonic and supersonic speeds to determine the aerodynamic effects due to proximity and jet interactions during LAT jettison from the CM at the end of an abort. The tests were run using two different scale models at angles of attack from 150deg to 200deg , sideslip angles from -10deg to +10deg , and a range of powered thrust levels from the jettison motors to match various jet simulation parameters with flight values. Separation movements between the CM and LAT included axial and vertical translations as well as relative pitch angle between the two bodies. The paper details aspects of the model design, nozzle scaling methodology, instrumentation, testing procedures, and data reduction. Sample data are shown to highlight trends seen in the results.

Rhode, Matthew N.↗

SECA Coal-Based Systems - FuelCell Energy, Inc.

The overall goal of this U.S. Department of Energy (DOE) sponsored project is the development of solid oxide fuel cell (SOFC) cell and stack technology suitable for use in highly-efficient, economically-competitive central generation power plant facilities fueled by coal synthesis gas (syngas). This program incorporates the following supporting objectives: • Reduce SOFC-based electrical power generation system cost to $700 or less (2007 dollars) for a greater than 100 MW Integrated Gasification Fuel Cell (IGFC) power plant, exclusive of coal gasification and CO 2 separation subsystem costs. • Achieve an overall IGFC power plant efficiency of at least 50%, from coal (higher heating value or HHV) to AC power (exclusive of CO 2 compression power requirement). • Reduce the release of CO2 to the environment in an IGFC power plant to no more than 10% of the carbon in the syngas. • Increase SOFC stack reliability to achieve a design life of greater than 40,000 hours. At the inception of the project, the efforts were focused on research, design and testing of prototype planar SOFC power generators for stationary applications. FuelCell Energy, Inc. successfully completed the initial stage of the project by meeting the program metrics, culminating in delivery and testing of a 3 kW system at National Energy Technology Laboratory (NETL). Subsequently, the project was re-aligned into a three phase effort with the main goal to develop SOFC technology for application in coal-fueled power plants with >90% carbon capture. Phase I of the Coal-based efforts focused on cell and stack size scale-up with concurrent enhancement of performance, life, cost, and manufacturing characteristics. Also in Phase I, design and analysis of the baseline (greater than 100 MW) power plant system—including concept identification, system definition, and cost analysis—was conducted. Phase II efforts focused on development of a ≥25 kW SOFC stack tower incorporating multiple stack building blocks of scaled-up cells, suitable for integration into a large-scale fuel cell power module. Activities in Phase II also included the development of the baseline system, factory cost estimate for the baseline plant’s power block, and conceptual design of a natural gas fueled sub-MW system to be used for testing and verification of the fuel cell stacks in a system environment. The specific objective for Phase III was the validation of the performance and robustness of stacks and scaled stack arrays suitable for use in large-scale power generation systems such as an IGFC with reliable, fail-safe operation being of paramount importance. The work culminated in the verification tests of a 60 kW SOFC stack module in a power plant facility. This final technical report summarizes the progress made during the project period. Significant progress was made in the areas of cell and stack technology development, stack module design, sub-scale module tests, Baseline Power Plant system development and Proof-of- Concept Module unit design. The development of this technology will significantly advance the nation’s energy security and independence interests while simultaneously addressing environmental concerns, including greenhouse gas emissions and water usage.

01 COAL, LIGNITE, AND PEAT↗

Dynamometer Testing of a NW2200 Drivetrain (CRADA Final Report)

Northern Power Systems specializes in direct drive wind turbine designs. CRADA CRD-10-394 involved testing the NW2200 wind turbine power train. Power train testing is important because it allows validation of the generator design and some control algorithms prior to installation on a tower, where this data would be more difficult and time consuming to collect. In an effort to keep the commercialproduct schedule on time, Northern Power requested testing support from the National Renewable Energy Laboratory for this testing. The test program was performed using NREL's 2.5 MW dynamometer test bed at the National Wind Technology Center near Boulder, CO.

17 WIND ENERGY↗

A proposed national wind power R and D program

An offshore wind power system is described that consists of wind driven electrical dc generators mounted on floating towers in offshore waters. The output from the generators supplies underwater electrolyzer stations in which water is converted into hydrogen and oxygen. The hydrogen is piped to shore for conversion to electricity in fuel cell stations. It is estimated that this system can produce 159 x 10 to the ninth power kilowatt-hours per year. It is concluded that solar energy - and that includes wind energy - is the only way out of the US energy dilemma in the not too distant future.

Heronemus, W.↗

Gradient-Based Optimization of Wind Farms with Different Turbine Heights: Preprint

Turbine wakes reduce power production in a wind farm. Current wind farms are generally built with turbines that are all the same height, but if wind farms included turbines with different tower heights, the cost of energy (COE) may be reduced. We used gradient-based optimization to demonstrate a method to optimize wind farms with varied hub heights. Our study includes a modified version of the FLORIS wake model that accommodates three-dimensional wakes integrated with a tower structural model. Our purpose was to design a process to minimize the COE of a wind farm through layout optimization and varying turbine hub heights. Results indicate that when a farm is optimized for layout and height with two separate height groups, COE can be lowered by as much as 5%-9%, compared to a similar layout and height optimization where all the towers are the same. The COE has the best improvement in farms with high turbine density and a low wind shear exponent.

17 WIND ENERGY↗

Miniature Arcs for Synthesis of Carbon Nanotubes in Microgravity

Although many methods are available for producing single-walled carbon nanotubes (SWNTs), the conventional carbon arc process remains the most popular due to its simplicity and large production rate. In the carbon arc, SWNTs are catalytically synthesized by rapidly evaporating a graphite anode impregnated with NiN metal catalyst from which the nanotubes grow in an inert atmosphere. However, high temperatures inside the carbon arc generate strong buoyancy driven convection, and it is hypothesized that the non-uniform environment created by this flow has a large effect on the growth and morphology of the SWNTs. To study the effect of buoyancy on the arc process, a miniature carbon arc apparatus was developed to synthesize SWNTs in a microgravity environment substantially free from these strong convective flows. The reactor was operated for either 2.2 or 5 seconds during free-fall in the drop towers at the NASA Glenn Research Center. Two apparatus designs differing mainly in their production rate and power capacity were investigated. The first consisted of a miniaturized carbon arc employing a 1 mm diameter graphite anode and powered by a 0.54 F capacitor bank charged to 65 V. The second, larger apparatus employed a 4 mm diameter anode and was powered by a portable battery pack capable of providing in excess of 300 amps at 30 volts to the arc for the duration of a 5 second drop. Initial results indicated that transient heating is a very large effect in the short-duration drop tower carbon arcs, and thermal equilibrium of the arc plasma, buffer gas, and apparatus was not attained during the short microgravity periods. In addition, removal of the buoyant convection by the microgravity now allowed clear observation of large jets of evaporated carbon vapor streaming from the anode and mixing with the inert buffer gas. The initial mixing of these jets with the cold buffer gas combined with the thermal transient made it difficult to establish a uniform high temperature environment around the arc in the 2.1 to 5 second microgravity time interval, and even with a very high-powered arc, the arc region was cooler than in continuously operated arcs. Despite these difficulties, the miniature arc produced SWNTs in microgravity. However, given the large thermal transient to overcome, no dramatic difference in sample yield or composition was noted between normal gravity and q2-,andL%econd long microgravity runs.

Alford, J. M.↗

Chapter 2: Global Value Chain and Manufacturing Analysis on Geothermal Power Plant Turbines

The global geothermal power market has shown significant growth since the last decade and is expected to reach a total installed capacity of 18.4 gigawatts electric (GWe) by the end of 2021 (GEA, 2016). The global geothermal power plant turbine market is dominated by a small number of manufacturers. Between 2005 and 2015, 82% of the geothermal steam turbines were manufactured in Japan, and 74% of the geothermal binary cycle turboexpanders were manufactured in Israel. During this period, the United States played an important role in the global trade flow of fully assembled turbine units and turbine parts, with a high volume of imports and exports. Another significant growth area was in Italian turbine/turboexpander manufacturers, who have increased their market share in the last couple of years. One other important change in the manufacturing market was in Turkey, where the bonus on feed-in-tariff (FIT) for domestic hardware components boosted the national manufacturing sector between 2010 and 2020. When planning geothermal power projects, developers customize their power plant size to fit the available geothermal resource capacity. The turbine is designed and sized to optimize the efficiency and utilization of resource and revenue production. The rest of the power plant components such as heat exchangers (HX), water-cooled cooling towers (WCCT), or air-cooled condensers (ACC) are then chosen to complement the turbine size and design. These one-off manufacturing custom design turbines have relatively higher manufacturing set-up costs, longer lead times, and higher capital costs than the standard design turbines manufactured in larger volumes. However, turbines produced in standard increments and in larger manufacturing volumes could result in lower costs per turbine, but potentially lower efficiency. Based on pipeline projects and resource assessments, there is significant potential value in creating standard turbine sizes that could offer an economic advantage, as is done for modular microturbines.

40 EE - Geothermal Technologies Office (EE-4G)↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY↗

University of Miami Coupled Model (UMCM) for Hurricanes Ike and Sandy

The University of Miami Coupled Model (UMCM) is a coupled model that integrates atmospheric, wave, and ocean components to produce wind, wave, and current data. Atmospheric data is produced using the [Weather Research and Forecasting model](https://www.mmm.ucar.edu/weather-research-and-forecasting-model) (WRF), Wave data is produced using the [University of Miami Wave Model](https://umwm.org/) (UMWM), While ocean current data is produced using the [HYbrid Coordinate Ocean Model](https://www.hycom.org/) (HYCOM). The time resolution for each model run is as follows: Hurricane Ike -> 1 sample/hour from 9/8/2008 12:00:00 UTC to 9/12/2008 6:00:00 UTC -> 1 sample/10 minutes from 9/12/2008 6:00:00 UTC to 9/13/2008 9:00:00 UTC Hurricane Sandy -> 1 sample/10 minutes from 10/28/2012 00:10:00 UTC to 10/31/2012 00:00:00 UTC

Array↗