Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Balloon-borne ultraviolet stellar spectrometer: Acquisition, tracking and command systems

The NASA Balloon-borne Ultraviolet Stellar Spectrometer (BUSS) which is carried to an altitude of 40 km by a 15 million cubic foot balloon for night-time observations of ultraviolet stellar spectra is discussed. The BUSS optical system, comprising an 0.40 m aperture Cassegrain telescope and an Ebert-Fastie spectrometer, points at various selected stars and focuses a portion of their spectra on the photocathode of an image dissector tube. The spectral region between 2,775 Angstroms and 2,825 Angstroms is sampled by the detector at 0.25 Angstroms increments using photon counting techniques. The pointing system for the payload uses a pair of orthogonal magnetometers which sense the earth's magnetic field for an aximuth reference, and a platform potentiometer for an elevation reference. This pointing system places the target star within the 3x1 degree field of view of an outer optical star tracker. The outer star tracker is then used to point the entire instrument to within one arc minute of the target star.

Gibson, W. C.↗

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.↗

Optimum testing of multiple hypotheses in quantum detection theory

The problem of specifying the optimum quantum detector in multiple hypotheses testing is considered for application to optical communications. The quantum digital detection problem is formulated as a linear programming problem on an infinite-dimensional space. A necessary and sufficient condition is derived by the application of a general duality theorem specifying the optimum detector in terms of a set of linear operator equations and inequalities. Existence of the optimum quantum detector is also established. The optimality of commuting detection operators is discussed in some examples. The structure and performance of the optimal receiver are derived for the quantum detection of narrow-band coherent orthogonal and simplex signals. It is shown that modal photon counting is asymptotically optimum in the limit of a large signaling alphabet and that the capacity goes to infinity in the absence of a bandwidth limitation.

Yuen, H. P.↗

A flash photolysis-resonance fluorescence study of the formation of O/1D/ in the photolysis of water and the reaction of O/1D/ with H2, Ar, and He

The technique employed in the study utilizes the vacuum ultraviolet flash photolysis of H2O combined with time resolved, simultaneous detection of H and O via resonance fluorescence at 121.6 and 130.2 nm respectively. The measurements were made by means of photon counting and multichannel scaling. The sensitivity of the system for H and O is discussed. Experiments are reported in which signals due to H and O were accumulated from the flash photolysis of a mixture of 0.1 torr H2O and 100 torr Ar. Attention is given to the relative importance of two primary processes in the photolysis of water.

Stief, L. J.↗

Infrared upconversion as a means of seeing in the dark

A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.

Gurski, T. R.↗

A precision star tracker utilizing advanced techniques and materials

An image dissector star tracker has been developed which operates in the photon counting mode making it possible to utilize all digital electronics. A unique pulse processing circuit allows bright stars to be tracked as well as dim stars. Thermal mechanical stability has been greatly enhanced by fabricating a housing with graphite/epoxy composite material with a linear coefficient of thermal expansion near zero. Test results indicate the +10 Mv stars can be acquired and tracked, while position variation with star intensity is less than 2 arc seconds from 2.5 Mv to +10 Mv. The noise equivalent angle for a +8 Mv star is 3 arc seconds. Polynominal correction for remaining cross-coupling and nonlinearity reduced error over total 1 x 1 deg field to 1.5 arc seconds.

Gates, R. F.↗

Development, applications, and future of infrared upconversion

Infrared upconversion is a technique that converts linearly polarized infrared photons to photons of higher frequency. The technique can be applied advantageously to the detection of IR radiation because the upconverted signal can be detected by photon-counting devices available for the visible spectral region. In addition, unlike presently available IR detectors, an upconversion device can provide sensitivity to IR radiation without the need for cryogenic cooling. Infrared upconversion was first demonstrated in 1961. By 1974, approximately 100% quantum conversion efficiency and a bandwidth of 1.81 microns had been attained. Photometric detection of IR radiation from various astronomical objects had also been demonstrated. Research is presently under way on the application of upconversion to astronomical spectroscopy and to imaging. The major drawback to the upconversion technique is the sheer bulk of the apparatus involved. It is anticipated that this problem can be overcome by applying the developing technology of integrated optics.

Gurski, T. R.↗

Intensified charge coupled devices for ultra low light level imaging

Development of a sensor incorporating a CCD and photocathode for operation in the electron bombarded mode in both a magnetic and an electrostatic focussed, gated configuration is described. Initial format size is 100 x 160 pixels with eventual growth to 400 x 400 pixels. The sensor is part of a digital camera system which includes the low level video conditioning electronics, a camera controller, a high speed buffer memory, and digital recording and display electronics. The memory uses CMOS/SOS and has a capacity of 1.6 Mbits with operating rates of 48 Mbits/sec. Individual frames are co-added to provide wide dynamic range and photometric precision better than 1%. A 4-bit video quantization is used to increase the photon counting detection rate before coincidence losses become serious.

Sobieski, S.↗

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.↗

Spectrophotometry of the transient X-ray source A0620-00

Optical observations of the transient X-ray source A0620-00 over the wavelength range from about 3200 to 6600 A are analyzed which were made with the 5-m Hale telescope using a multichannel spectrometer, a digital spectrograph with a cooled integrating SIT vidicon, and an image photon-counting system attached to the camera of the coude spectrograph. Infrared observations at 1.65, 2.2, and 3.5 microns are also examined. Individual spectral lines of special interest are discussed, the E(B-V) color excess is estimated to be about 0.40, and a distance of 1200 pc is adopted. Analysis of the continuous spectrum yields several simple binary models. A specific model is proposed in which one of the continuum sources is an optically thick object characterized by a model atmosphere at a temperature of 25,000 to 30,000 K and the second source is either a cool black body at 4000 K or a partially optically thick source of bound-free plus free-free radiation from a hydrogen gas with an electron temperature of at least 100,000 K. Some possible parameters of these sources and of the accretion disk are considered.

Oke, J. B.↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

Quantitative remote measurements of pollutants from stationary sources using Raman lidar

The several advantages of Raman lidar for remote measurements of stationary source emissions were quantitatively evaluated using a calibration tank at a distance of 300 m at night. Measurements of approximately 10 to the 3rd ppm SO2 with a 12% accuracy were demonstrated in an observation time of 15 min using a 1.5-J ruby laser at 30 pulses/min, 6-m range resolution, interference filters, photon counting detection, and a 20-cm receiver. Measurement accuracy was checked by measuring known concentrations of SO2 in the tank, by tuning the interference filters through the SO2 Raman line, and by varying the CO2 concentration to very high levels during the SO2 measurements. Evaluation of the seriousness of induced fluorescence from plume aerosols failed due to the inability to simulate the plume aerosols.

Poultney, S. K.↗

Flux measurements of CA II H and K emission

A four-channel photon-counting spectrophotometer (designated HKP-2) is described which is designed for measuring stellar chromospheric calcium emission. The HKP-2 is calibrated, and its performance and accuracy evaluated, by observing 63 of Wilson's (1968) program stars on the same nights with both the HKP-2 and a coude scanner designated HKP-1. The results of the observations are discussed in terms of the calibration of mean H-K flux indices, variations in individual stellar fluxes, the flux ratio for H and K, and the instrument color index. It is shown that the HKP-2 provides satisfactory performance in the measurement of stellar chromospheric emission in a manner closely analogous to the method of Wilson and that a single observation yields a color index as well as flux indices for H and K that can be calibrated and transferred unambiguously to Wilson's system of measurement.

Vaughan, A. H.↗

Charge coupled devices

The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

Walker, J. W.↗

Multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are described.

Timothy, J. G.↗

A progress report on multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are briefly described.

Timothy, J. G.↗

Parameter estimation in astronomy through application of the likelihood ratio

Many problems in the experimental estimation of parameters for models can be solved through use of the likelihood ratio test. Applications of the likelihood ratio, with particular attention to photon counting experiments, are discussed. The procedures presented solve a greater range of problems than those currently in use, yet are no more difficult to apply. The procedures are proved analytically, and examples from current problems in astronomy are discussed.

Cash, W.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗