Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Paradoxes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Comparison of Transesophageal and Transthoracic Contrast Echocardiography for Detection of a Patent Foramen Ovale

Presence of a patent foramen ovale may indicate paradoxic embolism in patients with otherwise unexplained embolic disease. Transthoracic contrast echocardiography has been used as a simple technique for detecting patent foramen ovale. However, particularly in patients with poor transthoracic image quality, presence of a patent foramen ovale might be missed. Transesophageal contrast echocardiography provides superior visualization of the atrial septum and therefore is believed to improve diagnostic accuracy. The present study investigates the influence of image quality on the detection of a patent foramen ovale by both transthoracic and transesophageal contrast echocardiography.

Siostrzonek, Peter↗

Transesophageal Echocardiography and Contrast-TCD in the Detection of a Patent Foramen Ovale: Experience with 111 Patients

Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.

Klotzsch, Christof↗

Polarization from Scattering in X-Ray Binaries

A paradox of X-ray binaries is that their strong X-ray flux ionizes much nearby low density gas, making it difficult to observe. Polarization can reveal gas which is fully ionized and can provide new insight into X-ray binary environments. In this talk I will present models for the scattering and polarization in X-ray binaries, adopting gas parameters which are chosen according to current ideas about these systems. These include stellar winds from a massive companion, X-ray induced disk winds, and the photospheres of a disk or binary companion.

Kallman, T.↗

Thermal Insulation Strips Conserve Energy

Launching the space shuttle involves an interesting paradox: While the temperatures inside the shuttle s main engines climb higher than 6,000 F hot enough to boil iron for fuel, the engines use liquid hydrogen, the second coldest liquid on Earth after liquid helium. Maintained below 20 K (-423 F), the liquid hydrogen is contained in the shuttle s rust-colored external tank. The external tank also contains liquid oxygen (kept below a somewhat less chilly 90 K or -297 F) that combines with the hydrogen to create an explosive mixture that along with the shuttle s two, powdered aluminum-fueled solid rocket boosters allows the shuttle to escape Earth s gravity. The cryogenic temperatures of the main engines liquid fuel can cause ice, frost, or liquefied air to build up on the external tank and other parts of the numerous launch fueling systems, posing a possible debris risk when the ice breaks off during launch and causing difficulties in the transfer and control of these cryogenic liquid propellants. Keeping the fuel at the necessary ultra-cold temperatures while minimizing ice buildup and other safety hazards, as well as reducing the operational maintenance costs, has required NASA to explore innovative ways for providing superior thermal insulation systems. To address the challenge, the Agency turned to an insulating technology so effective that, even though it is mostly air, a thin sheet can prevent a blowtorch from igniting a match. Aerogels were invented in 1931 and demonstrate properties that make them the most extraordinary insulating materials known; a 1-inch-thick piece of aerogel provides the same insulation as layering 15 panes of glass with air pockets in between. Derived from silica, aluminum oxide, or carbon gels using a supercritical drying process - resulting in a composition of almost 99-percent air - aerogels are the world s lightest solid (among 15 other titles they hold in the Guinness World Records), can float indefinitely on water if treated to be hydrophobic, and can withstand extremely hot temperatures (from 1,100 F to 3,000 F depending on the type of aerogel) down to cryogenic levels, making this "frozen smoke" ideal for use in space. Because of its low weight and ability to withstand temperature extremes, an aerogel was even used as the space-based catcher s mitt to trap comet particles and space dust for NASA s Stardust mission, launched in 1999. All of this remarkable technology s characteristics were ideal for NASA s purposes except one: The aerogels were extremely brittle. Through a long-term partnership between Kennedy Space Center and Aspen Aerogels Inc., of Northborough, Massachusetts, researchers developed a flexible, durable form of aerogel that NASA has since used as cryogenic insulation for space shuttle launch systems. Through Aspen Aerogels, the technology has made oil pipeline insulation, extreme weather clothing, and infrared shielding for combat helicopters.

Source record↗

Process Upsets Involving Trace Contaminant Control Systems

Paradoxically, trace contaminant control systems that suffer unexpected upsets and malfunctions can release hazardous gaseous contaminants into a spacecraft cabin atmosphere causing potentially serious toxicological problems. Trace contaminant control systems designed for spaceflight typically employ a combination of adsorption beds and catalytic oxidation reactors to remove organic and inorganic trace contaminants from the cabin atmosphere. Interestingly, the same design features and attributes which make these systems so effective for purifying a spacecraft's atmosphere can also make them susceptible to system upsets. Cabin conditions can be contributing causes of phenomena such as adsorbent "rollover" and catalyst poisoning can alter a systems performance and in some in stances release contamination into the cabin. Evidence of these phenomena has been observed both in flight and during ground-based tests. The following discussion describes specific instances of system upsets found in trace contaminant control systems, groups these specific upsets into general hazard classifications, and recommends ways to minimize these hazards.

Graf, John C.↗

Human Cardiovascular Adaptation to Weightlessness

Entering weightlessness (0 G) induces immediately a shift of blood and fluid from the lower to the upper parts of the body inducing expansion of the cardiac chambers (Bungo et al. 1986; Charles & Lathers 1991; Videbaek & Norsk 1997). For many years the effects of sudden 0 G on central venous pressure (CVP) was discussed, and it puzzled researchers that CVP compared to the 1-G supine position decreased during the initial hours of spaceflight, when at the same time left atrial diameter increased (Buckey et al. 1996). By measuring esophageal pressure as an estimate of inter-pleural pressure, it was later shown that this pressure decreases more than CVP does during 0 G induced by parabolic flights (Videbaek & Norsk 1997). Thus, transmural CVP is increased, which distends the cardiac chambers. This unique lung-heart interaction whereby 1) inter-pleural pressure decreases and 2) central blood volume is expanded is unique for 0 G. Because transmural CVP is increased, stroke volume increases according to the law of Frank-Starling leading to an increase in cardiac output, which is maintained increased during months of 0 G in space to levels of some 25% above that of the 1-G seated position (Norsk unpublished). Simultaneously, sympathetic nervous activity is at the level of the upright 1-G posture, which is difficult to explain based on the high stroke volume and decreased blood pressure and systemic vascular resistance. This paradox should be explored and the mechanisms revealed, because it might have implications for estimating the cardiovascular risk of travelling in space.

Norsk, Peter↗

Solar Drivers of 11-yr and Long-Term Cosmic Ray Modulation

In the current paradigm for the modulation of galactic cosmic rays (GCRs), diffusion is taken to be the dominant process during solar maxima while drift dominates at minima. Observations during the recent solar minimum challenge the pre-eminence of drift: at such times. In 2009, the approx.2 GV GCR intensity measured by the Newark neutron monitor increased by approx.5% relative to its maximum value two cycles earlier even though the average tilt angle in 2009 was slightly larger than that in 1986 (approx.20deg vs. approx.14deg), while solar wind B was significantly lower (approx.3.9 nT vs. approx.5.4 nT). A decomposition of the solar wind into high-speed streams, slow solar wind, and coronal mass ejections (CMEs; including postshock flows) reveals that the Sun transmits its message of changing magnetic field (diffusion coefficient) to the heliosphere primarily through CMEs at solar maximum and high-speed streams at solar minimum. Long-term reconstructions of solar wind B are in general agreement for the approx. 1900-present interval and can be used to reliably estimate GCR intensity over this period. For earlier epochs, however, a recent Be-10-based reconstruction covering the past approx. 10(exp 4) years shows nine abrupt and relatively short-lived drops of B to < or approx.= 0 nT, with the first of these corresponding to the Sporer minimum. Such dips are at variance with the recent suggestion that B has a minimum or floor value of approx.2.8 nT. A floor in solar wind B implies a ceiling in the GCR intensity (a permanent modulation of the local interstellar spectrum) at a given energy/rigidity. The 30-40% increase in the intensity of 2.5 GV electrons observed by Ulysses during the recent solar minimum raises an interesting paradox that will need to be resolved.

Cliver, E. W.↗

Coherent Multidecadal Atmospheric and Oceanic Variability in the North Atlantic: Blocking Corresponds with Warm Subpolar Ocean

Winters with frequent atmospheric blocking, in a band of latitudes from Greenland to Western Europe, are found to persist over several decades and correspond to a warm North Atlantic Ocean. This is evident in atmospheric reanalysis data, both modern and for the full 20th century. Blocking is approximately in phase with Atlantic multidecadal ocean variability (AMV). Wintertime atmospheric blocking involves a highly distorted jetstream, isolating large regions of air from the westerly circulation. It influences the ocean through windstress-curl and associated air/sea heat flux. While blocking is a relatively high-frequency phenomenon, it is strongly modulated over decadal timescales. The blocked regime (weaker ocean gyres, weaker air-sea heat flux, paradoxically increased transport of warm subtropical waters poleward) contributes to the warm phase of AMV. Atmospheric blocking better describes the early 20thC warming and 1996-2010 warm period than does the NAO index. It has roots in the hemispheric circulation and jet stream dynamics. Subpolar Atlantic variability covaries with distant AMOC fields: both these connections may express the global influence of the subpolar North Atlantic ocean on the global climate system.

Hakkinen, Sirpa M.↗

The Ancient Martian Climate System

Today Mars is a cold, dry, desert planet. The atmosphere is thin and liquid water is not stable. But there is evidence that very early in its history it was warmer and wetter. Since Mariner 9 first detected fluvial features on its ancient terrains researchers have been trying to understand what climatic conditions could have permitted liquid water to flow on the surface. Though the evidence is compelling, the problem is not yet solved. The main issue is coping with the faint young sun. During the period when warmer conditions prevailed 3.5-3.8 Gy the sun's luminosity was approximately 25% less than it is today. How can we explain the presence of liquid water on the surface of Mars under such conditions? A similar problem exists for Earth, which would have frozen over under a faint sun even though the evidence suggests otherwise. Attempts to solve the "Faint Young Sun Paradox" rely on greenhouse warming from an atmosphere with a different mass and composition than we see today. This is true for both Mars and Earth. However, it is not a straightforward solution. Any greenhouse theory must (a) produce the warming and rainfall needed, (b) have a plausible source for the gases required, (c) be sustainable, and (d) explain how the atmosphere evolved to its present state. These are challenging requirements and judging from the literature they have yet to be met. In this talk I will review the large and growing body of work on the early Mars climate system. I will take a holistic approach that involves many disciplines since our goal is to present an integrated view that touches on each of the requirements listed in the preceding paragraph. I will begin with the observational evidence, which comes from the geology, mineralogy, and isotopic data. Each of the data sets presents a consistent picture of a warmer and wetter past with a thicker atmosphere. How much warmer and wetter and how much thicker is a matter of debate, but conditions then were certainly different than what they are today. I will then discuss the origin and evolution of the early atmosphere from accretion and core formation to the end of the late heavy bombardment, including estimates of the volatile inventory, outgassing history, and potential escape mechanisms. This sets the stage for a comprehensive look at the climate system of early Mars and the attempts to solve the faint young sun problem. I will review the basic physics involved and then step through the different ideas highlighting their strengths and weaknesses. I will then conclude with a summary and a discussion of potentially promising avenues of future research

Mars↗

Formation and Preservation of the Depleted and Enriched Shergottite Isotopic Reservoirs in a Convecting Martian Mantle

There is compelling isotopic and crater density evidence for geologically recent volcanism on Mars, in the last 100-200 million years and possibly in the last 50 million years. This volcanism is due to adiabatic decompression melting and thus requires some type of present-day convective upwelling in the martian mantle. On the other hand, martian meteorites preserve evidence for at least 3 distinct radiogenic isotopic reservoirs. Anomalies in short-lived isotopic systems (Sm-146, Nd-142, Hf-182, W-182) require that these reservoirs must have developed in the first 50 to 100 million years of Solar System history. The long-term preservation of chemically distinct reservoirs has sometimes been interpreted as evidence for the absence of mantle convection and convective mixing on Mars for most of martian history, a conclusion which is at odds with the evidence for young volcanism. This apparent paradox can be resolved by recognizing that a variety of processes, including both inefficient mantle mixing and geographic separation of isotopic reservoirs, may preserve isotopic heterogeneity on Mars in an actively convecting mantle. Here, we focus on the formation and preservation of the depleted and enriched isotopic and trace element reservoirs in the shergottites. In particular, we explore the possible roles of processes such as chemical diffusion and metasomatism in dikes and magma chambers for creating the isotopically enriched shergottites. We also consider processes that may preserve the enriched reservoir against convective mixing for most of martian history.

Kiefer, Walter S.↗

Fifty Years of Boundary-Layer Theory and Experiment

The year 1954 marked the 50th anniversary of the Prandtl boundary-layer theory from which we may date the beginning of man's understanding of the dynamics of real fluids. A backward look at this aspect of the history of the last 50 years may be instructive. This paper (1) attempts to compress the events of those 50 years into a few thousand words, to tell in this brief space the interesting story of the development of a new concept, its slow acceptance and growth, its spread from group to group within its country of origin, and its diffusion to other countries of the world. The original brief paper of Prandtl (2) was presented at the Third International Mathematical Congress at Heidelberg in 1904 and published in the following year. It was an attempt to explain the d'Alembert paradox, namely, that the neglect of the small friction of air in the theory resulted in the prediction of zero resistance to motion. Prandtl set himself the task of computing the motion of a fluid of small friction, so small that its effect could be neglected everywhere except where large velocity differences were present or a cumulative effect of friction occurred This led to the concept of boundary layer, or transition layer, near the wall of a body immersed in a fluid stream in which the velocity rises from zero to the free-stream value. It is interesting that Prandtl used the term Grenzsehicht (boundary layer) only once and the term Ubergangsschicht (transition layer) seven times in the brief article. Later writers also used Reibungsschicht (friction layer), but most writers today use Grenzschicht (boundary layer).

Dryden, Hugh L.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment /Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, D.↗

Bone Turnover Does Not Reflect Skeletal Aging in Older Hispanic Men with Type 2 Diabetes

The paradox of fragility fracture in the presence of non-osteoporotic bone mineral density in older patients with type 2 diabetes mellitus (DM2) makes it difficult to clinically predict fracture in this vulnerable group. Serum osteocalcin (OC), a marker of bone turnover, increases with normal skeletal aging indicating risk of fracture. However, OC has been reported to be lower in patients with DM2. An inverse association between higher glycated hemoglobin levels (HbA1c) and lower serum OC in older DM2 patients triggered discussions encouraging further investigation. A key question to be answered is whether changes in glucose metabolism is responsible for bone metabolic changes, ultimately leading to increased risk of fragility fractures in DM2 patients. While these studies were conducted among Caucasian and Asian populations, this has not been studied in Hispanic populations who suffer from a higher prevalence of DM2. The Cameron County Hispanic Cohort (CCHC) in Texas is a homogeneous Hispanic cohort known to have high prevalence of DM2 (30%). Our preliminary data from this cohort reported OC levels lower than the suggested threshold for fragility fracture in post-menopausal women. We further investigated whether bone turnover in older CCHC adults with DM2 show a normal pattern of skeletal aging. Samples and data were obtained from a nested cohort of 68 (21 men and 47 women) Hispanic older adults (≥50 years) who had a diagnosis of DM2. Given high prevalence of uncontrolled DM2 in this cohort, we divided population into two groups: i) poor DM2 control with HbA1c level ≥8 (48% men and 38% women) and ii) good DM2 control with HbA1c level <8). A crosssectional analysis documented associations between serum OC and age adjusted HbA1c levels. There was no direct association between age and OC concentrations in our study. Higher HbA1c was associated with lower serum OC in men (odds ratio -6.5, 95% confidence interval -12.7 to - 0.3, p < 0.04). No significant associations were identified in women. Bone turnover in older Hispanic men with DM2 in our study does not reflect normal pattern of skeletal aging. It is unclear why similar results were not identified in women. We will continue to follow this cohort to investigate longitudinal trend of changes of bone turnover and its relationship with HbA1c in both men and women of this cohort.

Rianon, N.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, Douglas↗

A Possible Explanation for the Z-R Parameter Inconsistency when Comparing Stratiform and Convective Rainfall

The well-known Z-R power law Z A R(sup b) uses two parameters, A and b, in order to relate rainfall rate R to measured weather radar reflectivity Z. A common method used by researchers is to compute Z and R from disdrometer data and then extract the A-b parameter pair from a log-linear line fit to a scatter plot of Z-R pairs. Even though it may seem far more truthful to extract the parameter pair from a fit of radar Z(sub R) versus gauge rainfall rate R(sub G), the extreme difference in spatial and temporal sampling volumes between radar and rain gauge creates a slew of problems that can generally only be solved by using rain gauge arrays and long sampling averages. Disdrometer derived A-b parameters are easily obtained and can provide information for the study of stratiform versus convective rainfall. However, an inconsistency appears when comparing averaged A-b pairs from various researchers. Values of b range from 1.26 to 1.51 for both stratiform and convective events. Paradoxically the values of A fall into three groups: 150 to 200 for convective; 200 to 400 for stratiform; and 400 to 500 again for convective. This apparent inconsistency can be explained by computing the A-b pair using the gamma DSD coupled with a modified drop terminal velocity model, v(D) alpha D(sup beta) - w, where w is a somewhat artificial constant vertical velocity of the air above the disdrometer. This model predicts three regions of A, corresponding to w less than 0, w = 0, and w greater than 0, which approximately matches observed data.

gamma DSD↗

Reconstruction of Cysteine Biosynthesis Using Engineered Cysteine-Free and Methionine-Free Enzymes

Ten of the proteinogenic amino acids can be generated abiotically while the remaining thirteen require biology for their synthesis. Paradoxically, the biosynthesis pathways observed in nature require enzymes that are made with the amino acids they produce. For example, Escherichia coli produces cysteine from serine via two enzymes that contain cysteine. Here, we substituted alternate amino acids for cysteine and also methionine, which is biosynthesized from cysteine, in serine acetyl transferase (CysE) and O-acetylserine sulfhydrylase (CysM). CysE function was rescued by cysteine-and-methionine-free enzymes and CysM function was rescued by cysteine-free enzymes. Structural modeling suggests that methionine stabilizes CysM and is present in the active site of CysM. Cysteine is not conserved among CysE and CysM protein orthologs, suggesting that cysteine is not functionally important for its own synthesis. Engineering biosynthetic enzymes that lack the amino acids being synthesized provides insights into the evolution of amino acid biosynthesis and pathways for bioengineering.

proteinogenic amino acids↗

Fe(II) Oxidation and Sources of Acidity on Mars

There is an apparent paradox be-tween the evidence that aqueous environments on Mars were predominantly acidic, and the fact that Mars is predominantly a basaltic (and olivine-rich) planet. The problem being that basalt and olivine will act to neutralize acidic solutions they come into contact with, and that there is a lot more basaltic crust on Mars than water or acid. This is especially true if there is an appreciable amount of water available to bring the acid in contact with the basaltic crust. Several hypotheses for ancient mar-tian environments call on long lived groundwater and aqueous systems.

Niles, P. B.↗

Interstellar and Solar Nebula Materials in Cometary Dust

Laboratory studies of cometary dust collected in the stratosphere and returned from comet 81P/Wild 2 by the Stardust spacecraft have revealed ancient interstellar grains and molecular cloud organic matter that record a range of astrophysical processes and the first steps of planetary formation. Presolar materials are rarer meteorites owing to high temperature processing in the solar nebula and hydrothermal alteration on their asteroidal parent bodies. The greater preservation of presolar materials in comets is attributed to their low accretion temperatures and limited planetary processing. Yet, comets also contain a large complement of high temperature materials from the inner Solar System. Owing to the limited and biased sampling of comets to date, the proportions of interstellar and Solar System materials within them remains highly uncertain. Interstellar materials are identified by coordinated isotopic, mineralogical, and chemical measurements at the scale of individual grains. Chondritic porous interplanetary dust particles (CP IDPs) that likely derive from comets are made up of 0.1 - 10 micron-sized silicates, Fe-Ni-sulfides, oxides, and other phases bound by organic material. As much as 1% of the silicates are interstellar grains that have exotic isotopic compositions imparted by nucleosynthetic processes in their parent stars. Crystalline silicates in CP IDPs dominantly have normal isotopic compositions and probably formed in the Solar System. 81P samples include isotopically normal refractory minerals that resemble Ca-Al rich inclusions and chondrules common in meteorites. The origins of sub-micron amorphous silicates in IDPs are not certain, but at least a few % of them are interstellar grains. The remainder have isotopic compositions consistent with Solar System origins and elemental compositions that are inconsistent with interstellar grain properties, thus favoring formation in the solar nebula [4]. The organic component in comets and primitive meteorites has large enrichments in D/H and N-15/N-14 relative to terrestrial materials. These isotopic signatures are probably due to low temperature chemical processes in cold molecular clouds or the outermost reaches of the protoplanetary disk. The greatest isotopic anomalies are found in sub-micron organic nanoglobules that show chemical signatures of interstellar chemistry. The observation that cometary dust is mostly composed of isotopically normal minerals within isotopically anomalous organic matter is difficult to reconcile with the formation models of each component. The mineral component likely formed in high temperature processes in the inner Solar System, while the organic fraction shows isotopic and chemical signatures of formation near 10 K. Studying more primitive remnants of the Solar System starting materials would help in resolving this paradox. Comets formed across a vast expanse of the outer disk under differing thermal and collisional regimes, and some are likely to be better preserved than others. Finding truly pristine aggregates of presolar materials may require return of a pristine sample of comet nucleus material.

Messenger, Scott↗