Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗

Artificial Replication of Field Soiling Losses on PV Modules

In this paper, we experimentally demonstrate an improved replication of field soiling losses using an indoor artificial soiling chamber and tests on anti-soiling coated PV modules and coupons. The primary focus is to use site-specific soil collected from module surface and replicate the natural soiling processes including dust concentration in the air, slow and gradual dust accumulation and sedimentation on the module surface during the dominant soiling season of the site of interest. The experiments were conducted on two sample sets having different anti-soiling properties. The first set contains commercial modules with two different surface properties retrieved after three years of exposure from a single PV plant in a mid-Atlantic location; the other set contain glass coupons with three different coating materials that were installed and exposed over 4 months, at Lemoore, California. Major field-representative factors considered here for the close replication in the chamber include: the use of dust collected from modules surfaces at the outdoor sites to give the same dust chemistry; dust particle size distribution and concentration; the charge size of dust (< 0.15 g per injection); field humidity, and module temperature. The effectiveness of antisoiling coatings (or surface properties) for both sample sets were ranked in the artificial testing and were found to be closely matching with the field rank orders of the respective sites and sample sets. This paper provides the rank ordering results to objectively demonstrate the replication of field soiling losses in the artificial soiling chamber.

artificial soiling↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

bifacialVF - Bifacial PV View Factor model 2022 [SWR 17-58]

bifacialvf is a self-contained view factor (or configuration factor) model which replicates a 5-row PV system of infinite extent perpendicular to the module rows. Single-axis tracking is supported, and hourly output files based on TMY inputs are saved. Spatial nonuniformity is reported, with multiple rear-facing irradiances collected on the back of each module row. Bilinear interpolation code add-on to bifacialvf (description below) to pre-generate IV arrays and bifacial coefficients, and to examine the energy production with back side irradiance mismatch for either a portrait or landscape module. Included are IV curves and bifacial info for a Yingli (standard) module. Based on the publication: "A Practical Irradiance Model for Bifacial PV Modules" B. Marion, S. MacAlpine, C. Deline, A. Asgharzadeh, F. Toor, D. Riley, J. Stein, C. Hansen 2017 IEEE Photovoltaic Specialists Conference, Washington DC, 2017 URL: https://www.nrel.gov/docs/fy17osti/67847.pdf

Deline, Chris↗

Solution for Predictive Physical Modeling in CdTe and Other Thin-Film PV Technologies

The main goal of this work was to eliminate the ambiguity between the observed performance changes under stress and their physical root cause by enabling a depth of modeling that takes account of diffusion and drift at the atomistic level coupled to the electronic subsystem responsible for a PV device’s function. Development of advanced physical models describing capture/emission/ recombination phenomena relevant to multivalent dopants, amphoteric centers, and donor-acceptor pairs was also accomplished. These models, incorporating grain bulk, grain boundaries, and hetero-interface properties, were implemented in a self-contained simulation tool that drastically reduces interpretation ambiguity and, for the first time, allows for predictive design of thin-film PV devices.

14 SOLAR ENERGY↗

Benchmarking Utility-Scale PV Operational Expenses and Project Lifetimes: Results from a Survey of U.S. Solar Industry Professionals

This paper draws on a survey of solar industry professionals and other sources to clarify trends in the expected useful life and operational expenditure (OpEx) of utility-scale photovoltaic (PV) plants in the United States. Solar project developers, sponsors, long-term owners, and consultants have increased project-life assumptions over time, from an average of ~21.5 years in 2007 to ~32.5 years in 2019. Current assumptions range from 25 years to more than 35 years depending on the organization; 17 out of 19 organizations surveyed or reviewed use 30 years or more. Levelized, lifetime OpEx estimates have declined from an average of ~$\$$35/kW DC -yr for projects built in 2007 to an average of ~$\$$17/kW DC -yr in 2019. Across 13 sources, the range in average lifetime OpEx for projects built in 2019 is broad, from $\$$13 to $\$$25/kW DC -yr. Operations and maintenance (O&M) costs—one component of OpEx—have declined precipitously in recent years, to $\$$5-8/kW DC -yr in many cases. Property taxes and land lease costs are highly variable across sites, but on average are—together—of similar magnitude. Other OpEx line items include security, insurance, and asset management. Given 2007-2009 values for not only project life and OpEx but also other drivers of the levelized cost of energy (LCOE, excluding the investment tax credit), the LCOE for utility-scale PV projects built from 2007 through 2009 averaged $\$$305 /MWh. Using 2019 values for all parameters yields an average LCOE of $\$$51 /MWh. The decline in LCOE from $\$$305 /MWh to $\$$51 /MWh was predominantly caused by reductions in up-front expenditures (and, to a much lesser extent, by changes in capacity factors, financing costs, and tax rates), but 9% ($\$$22 /MWh) of the overall decline is due to improvements in project life and OpEx. Project life extensions and OpEx reductions have had similarly sized impacts on LCOE over this period, at $\$$11 /MWh each. Had project life and OpEx not improved over the last decade, LCOE in 2019 would have instead been $\$$73 /MWh—43% higher. Given the limited quantity and comparability of previously available data on these cost drivers, the data and trends presented here may inform assumptions used by electric system planners, modelers, and analysts. The results may also provide useful benchmarks to the solar industry, helping developers and assets owners compare their expectations for project life and OpEx with those of their peers.

14 SOLAR ENERGY↗

PV Performance Modeling and Stakeholder Engagement (Q3 FY2020 Project Report)

The objectives of this project are as follows: 1. Reduce uncertainty in PV performance models by developing and validating new and improved models and submodes. 2. Create and manage an open source repository of modeling functions and data. 3. Build and grow the PV Performance Modeling Collaborative; and, 4. Represent the US in the IEA PVPS Task 13 Working group.

14 SOLAR ENERGY↗

PV Performance Modeling and Stakeholder Engagement (Q1 FY2021 Project Report))

The objectives of this project are as follows: 1) Reduce uncertainty in PV performance models by developing and validating new and improved models and submodes. 2) Create and manage an open source repository of modeling functions and data. 3) Build and grow the PV Performance Modeling Collaborative 4) Represent the US in the IEA PVPS Task 13 Working group.

14 SOLAR ENERGY↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

Weather impacts on solar PV operations summary of the current body of knowledge and implications for further investigation

There is growing concern that severe weather events are negatively affecting solar photovoltaic (PV) systems and pose ongoing and unrecognized risks. Clearly research is needed to quantify and characterize the risks so that properly calibrated improvements can be implemented. To begin this process, this report is a collection of information of severe weather impacts on solar PV available today taken from research, insurance data, and field inspections. While it is not comprehensive enough to draw conclusions, this information provides a baseline for action and indicates an urgent need to investigate further.

14 SOLAR ENERGY↗

Ultra-Compact High Efficiency Multi-Level Gan-Based PV Inverter

This project developed the key technology for a scalable, high-density photovoltaic (PV) inverter, based on gallium-nitride (GaN) power semiconductors, and advanced digital control. Specifically, we explored the feasibility of a flying-capacitor multi-level inverter for 1.5 kV PV installations, through the development of hardware prototypes utilizing low-inductance commutation loop designs, robust digital control and signaling, and low-cost heatsink integration.

14 SOLAR ENERGY↗

Improving Common PV Module Temperature Models by Incorporating Radiative Losses to the Sky

PV module operating temperature is the second-most important factor influencing PV system yield–after irradiance–and a substantial contributor to uncertainty in energy system yield predictions. Models commonly used to predict operating temperature in system simulations are based on a simplified energy balance that lumps together different heat loss mechanisms–including radiation–and assumes an overall linear behavior. Radiative heat loss to the sky is usually substantial, but modeling it accurately requires additional information about down-welling long-wave radiation or sky temperature and increases the complexity of temperature model equations. In this work we show how radiative losses to the sky can be separated into two parts to improve the accuracy of modeling without additional complexity. We also predict and demonstrate the variation of these losses at different tilt angles and show that the effective view factor is reduced by the non- isotropic distribution of down-welling long-wave radiation. Finally, we demonstrate substantial reduction in bias (MBE) and scatter (RMSE) when the new radiative loss term is added to the Faiman model using one year of measurements at Sandia National Labs.

14 SOLAR ENERGY↗

Operation and Maintenance of PV Systems: Data Science, Analysis, and Standards

This effort improves the effectiveness and reduce uncertainty in O&M cost through four primary objectives/tasks: 1) institutionalize standards for reliability and availability reporting for large PV power plants; 2) bridge systemic O&M knowledge gaps around important topics affecting O&M; 3) characterize systemic failure modes and patterns and accelerate O&M experiential learning cycles using field data; and 4) establish a baseline understanding of UPVS O&M cost drivers. Key results of this effort include publication of IEC standards, published topical papers on O&M topics, training, and characterize field data for climate- and service-related patterns (additional details below). Integrating these results serves to reduce performance risk and facilitate improvement in the way solar projects are operated and maintained. Results are well received and two publications are among the most successful SETO publications at NREL ("Model of Operation and Maintenance Costs for Photovoltaic Systems with over 40,000 downloads and "Best Practices in Operation and Maintenance of PV Systems, 3rd Ed." with over 90,000 downloads).

14 SOLAR ENERGY↗

Task 12 PV Sustainability - Life Cycle Assessment of Crystalline Silicon Photovoltaic Module Delamination with Hot Knife Technology

The objective of this study is to complete a life cycle assessment (LCA) of a novel technology that separates the crystalline silicon (c-Si) photovoltaic (PV) module front glass from the backsheet using hot knife technology. This is known to be the most challenging step in module recycling, where the choice of delamination approach can determine the process selection for the next steps of the recycling process, the economic value of the recovered materials, and environmental performance. The life cycle inventory (LCI) reported here is based on primary data from the technology manufacturer. Different LCIs are established following the cut-off approach and the end-of-life (EOL) approach. The environmental impacts of the hot knife delamination process are analysed based on six indicators, and the main contributors to delamination efforts are identified. For the EOL approach, the potential environmental benefits from the recovered materials are compared to the environmental impacts caused by the delamination process. The functional unit of this analysis is the delamination of 1 kg of used framed c-Si PV modules at the place of installation.

14 SOLAR ENERGY↗

Library of Advanced Models of large-scale PV (LAMP) (Final Technical Report)

A suite of dynamic models of photovoltaic (PV) systems is developed in this project to accurately capture PV system dynamics during different contingencies. The following models are included: (i) quasi-dynamic, (ii) high-fidelity electromagnetic transient (EMT), (iii) advanced, and (iv) baseline. The models have the flexibility to consider different control functionalities at different controller levels. The study’s requirements determine the type of model needed. For example, high-fidelity EMT models are recommended for contingency studies. Advanced models are recommended for online or real-time implementations with resource constraints, whereas quasi-dynamic models are useful for studying the impact of weather variations.

14 SOLAR ENERGY↗

User Stories for PV Operations and Maintenance: Findings from the 2024 PVPMC Workshop

At the 2024 Photovoltaic (PV) Performance Modeling Workshop we collected user stories related to PV system monitoring, analytics, and operations and maintenance (O&M). In this context, user stories describe challenges with current practices and tools or imagining opportunities for improvements. From these user stories, we identified several near-term opportunities to improve photovoltaic system monitoring, analytics and O&M.

14 SOLAR ENERGY↗

PACT Perovskite PV Module Outdoor Test Protocol (Version 0.1)

The purpose of this protocol is to define procedures and practices to be used by the PACT center for field testing of metal halide perovskite (MHP) photovoltaic (PV) modules. The protocol defines the physical, electrical, and analytical configuration of the tests and applies equally to mounting systems at a fixed orientation or sun tracking systems. While standards exist for outdoor testing of conventional PV modules, these do not anticipate the unique electrical behavior of perovskite cells. Further, the existing standards are oriented toward mature, relatively stable products with lifetimes that can be measured on the scale of years to decades. The state of the art for MHP modules is still immature with considerable sample to sample variation among nominally identical modules. Version 0.0 of this protocol does not define a minimum test duration, although the intent is for modules to be fielded for periods ranging for weeks to months. This protocol draws from relevant parts of existing standards, and where necessary includes modifications specific to the behavior of perovskites.

14 SOLAR ENERGY↗

PACT Perovskite PV Module Outdoor Test Protocol (Version 0.2)

The purpose of this protocol is to define procedures and practices to be used by the PACT center for field testing of metal halide perovskite (MHP) photovoltaic (PV) modules. The protocol defines the physical, electrical, and analytical configuration of the tests and applies equally to mounting systems at a fixed orientation or sun tracking systems. While standards exist for outdoor testing of conventional PV modules, these do not anticipate the unique electrical behavior of perovskite cells. Further, the existing standards are oriented toward mature, relatively stable products with lifetimes that can be measured on the scale of years to decades. The state of the art for MHP modules is still immature with considerable sample to sample variation among nominally identical modules. Version 0.0 of this protocol does not define a minimum test duration, although the intent is for modules to be fielded for periods ranging for weeks to months. This protocol draws from relevant parts of existing standards, and where necessary includes modifications specific to the behavior of perovskites.

14 SOLAR ENERGY↗