An Experimental Study of Pressure Oscillation in a Capillary Pumped Loop with Multiple Evaporators and Condensers

The heat transport capability of a capillary pumped loop (CPL) is limited by the pressure drop that its evaporator wick can sustain. The pressure drop in a CPL is not constant even under seemingly steady operation, but rather exhibits an oscillatory behavior. A hydrodynamic theory based on a mass-spring-dashpot model was previously developed to predict the pressure oscillation in a CPL with a single evaporator and a single condenser. The theory states that the pressure oscillation is a function of physical dimensions of the CPL components and operating conditions. Experimental data agreed very well with theoretical predictions. The hydrodynamic stability theory has recently been extended to predict the pressure oscillations in CPLs with multiple evaporators and multiple condensers. Concurrently, an experimental study was conducted to verify the theory and to investigate the effects of various parameters on the pressure oscillation. Four evaporators with different wick properties were tested using a test loop containing two condenser plates. The test loop allowed the four evaporators to be tested in a single-pump, two-pump or four-pump configuration, and the two condenser plates to be plumbed either in parallel or in series. Test conditions included varying the power input, the reservoir set point temperature, the condenser sink temperature, and the flow resistance between the reservoir and the loop. Experimental results agreed well with theoretical predictions.

Ku, Jen-Tung↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulated Altitude Performance of Combustors for the 24C Turbojet Engine. III - Performance of Rectangular-Slot Baskets: Performance of Rectangular-Slot Baskets - 3

The performance of an annular combustion chamber from a 24C turbojet engine was investigated over a range of simulated altitudes from 20,000 to 55,000 feet and corrected engine rotor speeds from 6000 to 13,000 rpm at a simulated ram-pressure ratio of 1.04. The purpose of the investigation was to determine the effects on the altitude operational limits, combustor-outlet gas temperature distribution, combustion efficiencies, and combustor inlet-to-outlet total-pressure drops of two changes in the 24C-4B basket air-passage arrangements that were designed to improve combustor-outlet temperature distribution. These changes were: (a) replacement of the downstream secondary air holes with large rectangular slots further upstream (rectangular-slot basket), and (b) enlargement of anticoking holes in the rectangular-slot basket (modified rectangular-slot basket). The results indicate that improved outlet-gas temperature distribution of each succeeding combustor basket investigated was attained at a sacrifice in the altitude limit of operation. The altitude limits of operation of the combustor with the original basket ranged from 34,000 feet at a corrected engine speed of 6000 rpm to a maximum of 52,000 feet at 12 ' 500 rpm. The altitude limits of the rectangular-slot basket were about 2000 feet lower throughout the engine speed range than those of the original basket. The altitude limits of the combustor with the modified rectangular-slot basket were about equivalent to those of the other baskets in the corrected-engine-speed range from 12,000 to 12,500 rpm but were about 10,000 feet lower than those of the original basket in the corrected-engine-speed range from 6000 to 9000 rpm. For the same inlet-air conditions, the combustion efficiencies were highest for the original basket and progressively lower for each of the other two baskets. The combustor inlet-to-outlet pressure drops of all three combustor baskets at the same operating conditions were within +/- 10 percent of the pressure drop of the original basket.

Tischler, Adelbert O.↗

Hybrid Filter Membrane

Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of dust particles on the filter surface and to facilitate dust removal with pulse or back airflow.

Laicer, Castro↗

CFD Simulation of Helium Flow Loop Test Section

A helium flow loop is being assembled at Oak Ridge National Laboratory to analyze heat transfer enhancement for systems such as blanket and divertor components. To efficiently identify optimum geometries for heat transfer enhancement in these applications, simulation work is performed to optimize test section designs that are built and tested in the helium flow loop that operates at 4 MPa and a mass flow rate of 100 g/s. Different ribbed geometries that examine rib shape, rib height, rib orientation, rib spacing, and three dimensional orientation are modeled and simulated in STAR-CCM+ to compare their ability to remove heat and mitigate pressure drop. Following the simulations, models are selected and manufactured for the helium flow loop tests. Simulations initially focus on a hydrodynamic study to determine the appropriate mesh and physics models and then add a heat flux to analyze the heat transfer abilities of the models. The simulations are run in steady state and use a Reynolds-averaged Navier-Stokes k-ε turbulence model. The helium is modeled as an ideal gas. The simulation explores models of geometries that enhance the heat transfer and decrease pressure drop with an overall goal of increasing fluid collision with the wall. Enhanced geometries are simulated to select appropriate designs for manufacturing, and preliminary experimental results are used to validate the simulations. Furthermore, the factors that are being analyzed in the comparison between the experimental and the simulated results include matching thermocouple temperatures, pressure drop, roughness, and fluid velocity.

42 ENGINEERING↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Optimizing flow condensation models for next-generation refrigerants in axial micro-fin aluminum tubes

To support the transition to next-generation refrigerants, accurate modelling of heat transfer and pressure drop is essential for designing efficient heat exchangers. Current models, largely based on traditional refrigerants and unexpanded micro-fin tubes, may not reliably predict performance for new refrigerants and expanded micro-fin geometries. This study evaluates four condensation models using experimental data for six A2L refrigerants: R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E). For heat transfer models, the Han and Lee (2005) model initially yields the best accuracy (mean absolute Deviation, MAD = 22.1%). To further improve predictions, a correction factor reduces the Cavallini et al. (2009) model’s MAD from 68.2% to 15.4%, while optimization of the Kedzierski and Goncalves (1997) model achieves a MAD of 13.1%. For pressure drop, the Cavallini et al. (1997) model proves most accurate (MAD = 6.4%), with the simpler Haraguchi et al. (1993) model also effective (MAD = 9.4%). Keywords: Flow condensation models, heat transfer coefficient, frictional pressure drop, next-generation refrigerants, aluminum micro-fin tubes

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

Validation of CTF Droplet Entrainment and Annular/Mist Closure Models using Riso Steam/Water Experiments

This document summarizes the work to validate the droplet entrainment and de-entrainment models, as well as two-phase closure models in the CTF (Coolant Boiling in Rod Arrays - Two Fluids) code by comparison with experimental data obtained at Risoe National Laboratory. CTF is the modernized version of the subchannel code, COBRA-TF, being jointly developed by Oak Ridge National Laboratory and North Carolina State University for applications in the Consortium for Advanced Simulation of Light Water Reactors (CASL). The Risoe data included a series of more than 250 steam/water experiments that were performed in both tube and annulus geometries over a range of various pressures and outlet qualities. Experimental conditions were set so that the majority of cases was in the annular/mist flow regime. Measurements included liquid film flow rate, droplet flow rate, film thickness, and two-phase pressure drop. CTF was used to model 180 of the tubular geometry cases, matching experimental geometry, outlet pressure, and outlet flow quality to experimental values. CTF results were compared to the experimental data at the outlet of the test section in terms of vapor flow fractions, and entrained liquid flow fractions, and pressure drop per unit length.

42 ENGINEERING↗

Conceptual design of pressure relief systems for cryogenic application

The conceptual design of pressure relief systems is an important aspect in the early phase of any cryogenic system design, because a prudent and responsible evaluation of relief systems involves much more than just relief devices. The conceptual design consists of various steps: At first, hazard scenarios must be considered and the worst-case scenario identified. Next, a staged interaction against pressure increase is to be defined. This is followed by the selection of the general type of pressure relief device for each stage, such as safety valve and rupture disc, respectively. Then, a decision concerning their locations, their capacities and specific features must be taken. Furthermore, it is mandatory to consider the inlet pressure drop and the back pressure in the exhaust line for sizing the safety devices. And last but not least, economic and environmental considerations must be made in case of releasing the medium to the atmosphere. The development of the system's safety concept calls for a risk management strategy based on identification and analysis of hazards, and consequent risk mitigation using a system-based approach in compliance with the standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric performance of extruded axial grooved heat pipes from 100 to 300 K

Extensive performance data derived from tests with an aluminum axial grooved extruded heat pipe is presented for oxygen, methane, ethane, and ammonia as working fluids. The effects of operating temperature, fluid inventory, heat flux, and elevation on the transport capability and the evaporator and condenser film coefficients are measured and compared to theory. The data correlation indicates that, in addition to the viscous pressure drop of the fluid, a vapor induced liquid pressure drop must be taken into account at temperatures near or below the normal boiling point of the fluid. Methane, ethane, and ammonia are all suitable working fluids for this groove geometry; however, oxygen, because of its low static height, is at best marginal in the 100-120 K range.

Schlitt, K. R.↗

A 3-D CFD Analysis of the Space Shuttle RSRM With Propellant Fins @ 1 sec. Burn-Back

In this study 3-D Computational Fluid Dynamic (CFD) runs have been made for the Space Shuttle RSRM using 2 different grids and 4 different turbulent models, which were the Standard KE, the RNG KE, the Realizable KE, and the Reynolds stress model. The RSRM forward segment consists of 11 fins. By taking advantage of the forward fin symmetry only half of one fin along the axis had to be used in making the grid. This meant that the 3-D model consisted of a pie slice that encompassed 1/22nd of the motor circumference and went along the axis of the entire motor. The 3-D flow patterns in the forward fin region are of particular interest. Close inspection of these flow patterns indicate that 2 counter-rotating axial vortices emerge from each submerged solid propellant fin. Thus, the 3-D CFD analysis allows insight into complicated internal motor flow patterns that are not available from the simpler 2-D axi-symmetric studies. In addition, a comparison is made between the 3-D bore pressure drop and the 2-D axi-symmetric pressure drop.

Morstadt, Robert A.↗

Characterization of solids deposited on the modular caustic-side solvent extraction unit (MCU) coalescer media removed in October 2014

In February 2015, Savannah River National Laboratory (SRNL) received a Strip Effluent (SE) coalescer (FLT-304) from MCU. That coalescer was first installed at MCU in July 2014 and removed in October 2014. While processing approximately 31,400 gallons of strip solution, the pressure drop steadily increased from 1 psi to beyond the administrative limit of 20 psi. The physical and chemical analysis was conducted on this coalescer to determine the mechanism that led to the plugging of this coalescer. Characterization of this coalescer revealed the adsorption of organic containing amines as well as MCU modifier. The amines are probably from the decomposition of the suppressor (TiDG) as well as from bacteria. This adsorption may have changed the surface energetics (characteristics) of the coalescer fibers and therefore, their wetting behavior. A very small amount of inorganic solids were found to have deposited on this coalescer (possibly an artifact of cleaning the coalescer with Boric acid. However, we believe that inorganic precipitation, as has been seen in the past, did not play a role in the high pressure drop rise of this coalescer. With regards to the current practice of reducing the radioactive content of the SE coalescer, it is recommended that future SE coalescer should be flushed with 10 mM boric acid which is currently used at MCU. Plugging of the SE coalescer was most likely due to the formation and accumulation of a water-in-oil emulsion that reduced the overall porosity of the coalescer. There is also evidence that a bimodal oil particle distribution may have entered and deposited in the coalescer and caused the initial increase in pressure drop.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis, Verification, and Application of Equations and Procedures for Design of Exhaust-pipe Shrouds

Investigations were made to develop a simplified method for designing exhaust-pipe shrouds to provide desired or maximum cooling of exhaust installations. Analysis of heat exchange and pressure drop of an adequate exhaust-pipe shroud system requires equations for predicting design temperatures and pressure drop on cooling air side of system. Present experiments derive such equations for usual straight annular exhaust-pipe shroud systems for both parallel flow and counter flow. Equations and methods presented are believed to be applicable under certain conditions to the design of shrouds for tail pipes of jet engines.

HEAT EXCHANGERS, SHROUDED↗

Advanced sorbents for modular oxygen production for REMS gasifiers

Under a DOE funded effort, Thermosolv LLC has been developing a sorbent-based oxygen production technology for gasification and oxy-combustion applications. The sorbents utilize oxygen-storage properties of certain perovskites to (1) selectively adsorb oxygen at moderate temperature from compressed air and (2) release the adsorbed oxygen into a vacuum or a sweep gas such as CO2 and/or steam. Through cyclic operations of multiple sorbent beds such a process can be made continuous. Pressure drop across the sorbent bed and other similar design considerations dictate that the sorbent be in the form of a high surface-area-to-volume pellet and yet still possess sufficient crush strength and integrity. Process efficiency is determined by the sorption and desorption kinetics and sorbent capacity. Typical process involves cycle times in the order of 100 seconds, a time too short to fully utilize the full volume of the sorbent and the sorption capacity of the sorbent pellets. As a part of this project, Thermosolv LLC undertook the development of oxygen sorbents as a high-surface area supported sorbent on a light-weight inert support to (1) reduce the cost, (2) increase the productivity, and (3) reduce the overall weight of the reactor. Using a previously developed perovskite (LSCF 1991) with its well-characterized performance, composite sorbent pellets each consisting of an inert core coated by a thin layer of the functional perovskite material were produced. Several low-density, inexpensive inert solids supports in the 1/8”-1/4” size were selected to keep the pressure drop across the sorbent bed in the acceptable range. A number of commercial technologies including spray coating, dip coating, incipient impregnation of porous substrate followed by thermal annealing at various temperatures and duration were employed and tested to produce robust composite supported sorbent pellets. A sense of optimum coating thickness was developed by testing sorbent pellets of various increasing diameter pellets. LSCF-1991extrudates ranging in size from 1/32” to 3/16” were tested in a TGA and in a fixed-bed pressure swing test set-up for sorption/desorption cycles of interest. The data show that for the operational conditions of interest the coating thickness for a supported sorbent pellet needs to be approximately 1/32” (about 0.8 mm). Subsequent work thereby concentrated on developing composite pellets of various substrates, shapes and sizes with coating layer of about this size range. Candidate support materials were chosen based on cost, inertness, mechanical strength, thermal expansion and chemical stability with sorbent material, and in a size range to give an acceptable pressure drop in fixed-bad reactor configurations. Coating application methods used for application of the sorbent onto the support included precipitation, spray coating and dip coating from sorbent slurries and sol gels. For all coated supports where we could successfully apply a uniform coating of desired thickness with an acceptable handling performance in terms of exfoliation, TGA-based cyclic sorption/desorption testing was performed to determine cycling capacity of oxygen. Among nearly twenty different support materials tested, best adhesion performance was obtained from stainless saddle supports. In the bench-scale fixed-bad tests stainless steel saddle support composite pellets with a coating thickness in the 0.6 mm or so range, the composite sorbent pellet performance approached up to 95% of that of the 2 mm parent material pellets. In a parallel approach to reducing the cost of the sorbent, alternate sorbent formulations replacing/reducing the amount of cobalt in the LSCF family were also investigated. Successful formulations that could match the performance of LSCF 1991 were identified based on TGA cyclic tests as LSCF 1919 and LSF 1910. In the range of operational envelop of cycle times and other relevant process operating conditions, the reduced Co formulations showed comparable performance in the bench-scale fixed-bad cyclic operations. As a part of this project, we also attempted substitution of La and Sr with Ca and Ba, and Co with Mn, Ni and Cu with little success, but the overall project goal of reducing sorbent cost in terms of raw material and manufacturing expenses was successful.

01 COAL, LIGNITE, AND PEAT↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Validation of the Porous Medium Approximation for Hydrodynamics Analysis in Compact Heat Exchangers

Compact heat exchangers (HXs) have gained attention in recent years in various fields such as solar and nuclear power generation, oil and gas, and refrigeration due to their low cost, high power density, and robustness in high-pressure and/or high-temperature environments. However, the large difference between a compact HX's overall dimensions (~m) and the much smaller scale of its channels (~mm) makes it challenging to model the entire HX at once, due to computational limitations. In this work, we treat the channeled region of a compact HX as a porous medium (PM) to circumvent the need to model/mesh each individual channel. This allows us to simulate the entire HX, including both the header and channeled regions while maintaining the computational cost at a practical level. Although the porous medium approach has been used to model heat exchangers, its validity is still questionable because (1) the resistance coefficients are heavily data-based and thus difficult to be applied to new heat exchangers and (2) the validation has been focused on matching the overall pressure drop in the channel region, which does not address whether such model can predict detailed pressure and velocity field. For the first time, this work addresses under what circumstances and with what uncertainty does the PM approach work for hydrodynamics modeling in compact HXs. By answering these questions, we introduce the PM approach as a powerful tool for HX hydrodynamics modeling that can predict not only the overall pressure drop but also the detailed pressure and velocity distributions.